| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹44.2 L+₹4.3 L (10.7%)Rejected-Finance N S T COLONY CIRCULAR ROAD HOUSE NO 04 DMC DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹45.3 L+₹5.4 L (13.5%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹48.3 L+₹8.3 L (20.8%)Rejected-Finance HOUSE NO 59 THILIXU VILLAGE BLOCK V PS POST DIMAPUR NAGALAND 797 112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹48.3 L+₹8.3 L (20.8%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
21 Nov 2020, 6:00 pmClosed
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
SPECIAL REPAIR TO RETAINING WALL IN FRONT OF BLDG NO T-13 AND T-17 IN 3 CORPS CAMP, SPECIAL REPAIR TO BLDG NO T-86 (STORE HOUSE) IN 3 CORPS OMC, SPECIAL REPAIR TO BLDG NO T-39 OF 50 COY ASC (SUP) AND CERTAIN REVENUE AND MINOR WORKS AT RMS
2020_MES_393772_1
8340/E8
Open Tender
Civil Works
Item Rate
180 days
Rangapahar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
GE 868 EWS
₹84,000
Yes
27 Sept 2022
9 Nov 2020
23 Nov 2020
9 Nov 2020
21 Nov 2020
16 Nov 2020
9 Nov 2020 - 10 Nov 2020
Amount
Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L PCC 1:4:8 type D-2 s(using 40mm grade stone aggregate as in foundation etc and mass concrete.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) 100mm thick as Sub Base under floor
M&L cement concrete type C2 1:3:6 (40 mm graded agg) as in surface channels and drains
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl firms moulds
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto
M & L for 75 mm thick PCC 1:3:6 type C2 , using 40 mm graded agg in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed
M & L for PCC 1:3:6 type C-2, 75 mm thick (using 40 mm graded stone aggregate) as in flooring complete all as specified and as directed.
M & L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation complete all as specified and directed.
M&L for mirror polished machine cut kota stone slab flooring 20-25 mm thick over bed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed
M&L for providing Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in wall and set and jointed in neat cement slurry and pointed with grey cement to match the stone over and including 10 mm thick rendering in CM 1:4 for laying in vertical surfaces complete all as specified and directed.
Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excl ashalar facing
Brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6.
Material and labour for brick work in cement mortar 1:4 with sub class `B' bricks straight or curved on plan exceeding 6m mean radius as in pillars complete all as specified.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M & L rendering 15 mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement.
M & L rendering 15mm thick in cement mortar 1:4 (in two layers first layer of 10 mm th and second layer 5 mm thick including water proofing compound) on other than fair faces of brick or concrete work even and smooth without using extra cement. (Note : WPC shall be measured and paid separately)
M & L 12mm thick rendering on fair faces of brick wk or concrete surface in CM 1:3 with using water proofing compound 2% by wrought all as specified (WPC paid separately).
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces.
M&L for rendering 15mm thick in CM 1:4 other than fair faces of brick work or concrete surfaces finished even and fair without using extra cement.
Demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing complete all as specified and directed.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in lime mortar (one side only measured in cases where both sides are plastered)
M&L GI wire netting 0.71 mm dia and 12 mm mesh lathing into reed in walls incl all laps cutting and waste complete all as specified and directed.
M&L 15 mm thick plastering in CM 1:4 on one side of lathing in two separate layers even and smooth without using extra cement incl WPC (WPC shall be measured and paid separately) complete all as specified and directed.
M&L 12 mm thick plastering in CM 1:6 the other side of lathing finished even and smooth without using extra cement complete all as specified and directed.
Integral water proofing compound complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of White wash on walls all as specified & directed by Engineer-in-Charge
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls all as specified & directed by Engineer-in-Charge
Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings.
S & F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Dismantling framed trusses of span not exc 10m
Dismantling timber scantlings unframed work 40 sqcm and over in section in any position complete all as specified and directed.
S/F 2nd class hard wood scantling as in purlins rafters ,& framed work etc clean sawn complete all as specified and directed.
All as per item No. 35 above but except timber complete all as specified and directed.
M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rail and fastenings and heavy brackets framing ( Beam, tee,angle channel or flat sections) incl distance piecea, cleats etc conforming to Fe 410-W (Gde-E 250) quality A.
Material and labour preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specifed and directed.
Taking down chowkhat or frames exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutter from the frame) complete all as specifed and directed.
M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints complete all as specified and directed.
M&L for 35 mm thick 2nd class hardwood plain framed panelled shutter (any number of panels) with panels of timber flat on both sides or of veneered particle board medium density , wood particle board with commercial face veneers , supplied and fitted to chowkats complete all as specified and directed.
M/L 30mm thick 2nd class hard wood Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. divided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size
M&L butt hinges medium grade cold rolled mild steel and fixed size of hinges 50 mm long size
S/F Aluminium anodised barrel tower bolt of extruded section and fixed 200 mm long
S&F Aluminium handle cast type anodised 150 mm long
S/F Aluminium alloy anodised sliding door bolt with hasp and staple (bolt type fixing clips of sheet cast or extruxded section(300 mm long)
S/F mild steel barrel tower bolt stove enamelled black eith bright and fixed to shutters 100mm long.
M & L sheet glass ordinary quality 3mm thick and glazing with oil putty in squares n.exc. 0.5 sqm each pane complete all as specified and directed.
M&L butt hinges, medium weight 75 mm long size
S/F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long
S&F 150mm long aluminum hook and eye, complete all as specifed and directed.
S&F 100mm size aluminium handles,cast type,anodised all as directed complete all as specified and directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. -
M&L for brocken stone or boulders hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surfaces all as specified and directed.
M&L for 25mm thick cement concrete type B-0 (1:2:4) (using 12.5 mm graded stone aggregate ) as in flooring finished even and smooth using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured tiles of size 300x200mmx7 mm thick, on verticals surfaces, set and jointed in neat cement slurry and pointed in coloured.
M&L for screed bed 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished rough to receive tiles wall finishes.
M&L for PCC 1:2:4 type B- 1, (20mm graded aggregate) 40 mm thick as in floor finished
M & L for 40 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) in floors and finishing concrete surfaces even and smooth without using extra cement all as specified and directed.
Dismantling wall and ceiling board fibre, insulation etc or insulation boards any thickness including cover fillets all as specified.
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic to be fixed aluminium grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mm duly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified.
S&F for Joist, channel, angle,post or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe-290 (Gde E165)
Taking down shutters of any description exceeding 1.0 Sqm but not exceeding 2.0 sqm each complete
Taking down cement plaster on walls built in cement mortar etc including racking out joints, hacking for key, scrubbing down with water etc.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
M&L second class hard wood small fittings such as brackets of any type, shaped door and window stopers and the like, including all necessary labours , articles no exceeding 200 cu.cm each.
Supply and fixing wire cloth 0.56mm nominal dia of wire and avg width of aperture 1.18mm complete all as specified and directed.
S&F Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete
S&F for mild steel conforming to Fe 410-0 or Fe 310-0 in bands, straps, supports or stays for rain water, including bolts, if required, hook and pintle hinges; hand made sliding bolts; clamps; hold fasts; hooks for hanging fans and similar small articles.
M&L for preparing surfaces of small articles such as holdfast etc. of steel or iron, new or old, area not exceeding 0.1 Sqm each and treating with tar or coal tar black paint.
M&L for preparation of new plastered surfaces of walls and applying two coat of oil bound distemper over a coat of primer all as specified.
M&L for preparation of old surfaces of steel and iron work of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint in any tint complete all as specified & directed.
M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint in any tint all as specified and directed
Complete removal of existing treatment of walls and preparation of old surfaces of wall including scrapping down, smoke soot, efflorescent salts trading oil and greasy spots etcapplying two coats of cement base paint over a coat of chalk whitening/primer complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil
Excavating over areas, n exc 1.5 m deep, exceeding 10sq.m on plan and getting out soft/loose soil
M & L for walling of random rubble, uncoursed well bounded bedded and solidly hearted, built in CM (1:6) including provision of weep holes complete all as specified and directed.
All as per ser No 81 here-in-before but except stones
M & L for PCC (1:3:6) type C-2 using 20mm stone graded aggregate as bond stone including necessary form work complete all as specified.
M & L for PCC (1:3:6) type C-2 using 20mm graded aggregate as in coping including necessary form work all as specified and directed
M&L cement concrete 1:2:4, Nominal Mix type B1(20mm graded stone aggregate) as in coping, kerb etc including necessary form work complete all as specified.
M&L for raised pointing to random or polygonal rubble uncoursed or brought up to course in CM (1:4) complete all as specified and directed.
S&F for 110 mm dia PVC (SWR) pipe single socketed in any length with rubber joints laid in trenches/floor/weep holes and similar work all as specified.
S&F for 160mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed as vent pipes.
S&F of 75dia PVC (SWR) Vent cowl
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25cm in soft/loose soil complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in soils
Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface in soft/ loose soil.
M & L for RCC 1:2: 4 , type B-1 (using 20 mm graded stone aggregate) Nominal mix as in Slabs supported on walls, bearms and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
TMT bars 10 mm dia and over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to Fe-410 Gde E-250 complete all as specified and directed..
M&L reinforcement TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, bent to shape required including cranking required and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips quality confirming to Fe-410 Gde E-250 complete all as specified and directed.
M & L Formwork to soffits of suspended slabs, such as roof slabs, floor slabs, landings and similar work; not exc 200 mm thick (horizontal or sloping)
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and RCC/PCC band in wall etc.
Material and labour Reinforced cement concrete (Nominal Mix) in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes, septic tanks, soakage wells etc. complete all as specified & as directed by Engineer-in-charge. Note: - Reinforcement shall be measured and paid for separately.
Excavating in Trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation etc or for shafts,wells, cesspits, manholes etc not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L providing precast cement concrete louvers and jalies, 30mm thick (measured solid), type B-0 (12.5mm graded stone agg) including moulding but excluding frame and set in CM (1:4) complete
Precast RCC (1:2:4) type B-1 in drain slab cover etc including necessary form work complete set in cement mortar 1:6 complete.
M & L Reinforced cement concrete (Nominal mix) Type B1 1:2:4 usinng 20mm graded stone agg as in Foundaticns, including rafts, foot- ings, foundation beams, plinth beams; bases for columns, etc basement slabs,underreamed piles.
M & L Reinforced cement concrete (Nominal mix) Type B1 1:2:4 usinng 20mm graded stone agg as in columns, piers, pillars, struts, etc
M&L reinforced concrete pipes, class NP 2 ,300 mm dia laid and jointed complete with collars complete all as specified and directed.
M&L for Concrete bed to 300 mm drain pipes including packing under,and completely surrounding pipes with cocrete after they are laid and tested
M & L for bib cock CP with wall flange, fancy type 15 mm dia bore.
S&F 15mm bore GI water tubing medium grade laid in floors or fixed in wall including GI fittings.
S&F 20 mm bore GI water tubing medium grade laid in floors or fixed in wall including GI fittings.
M&L for PCC 1:3:6 type C-2(40mm grade stone aggregate)as in bed to 160mm dia PVC drain pipes including packing under and haunching against the sides of pipes after they are laid and tested.
Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching and forming branch channel, half round or 3/4 section in cement concrete1:2:4 type B1 smooth finished and reforming benching as required, internal dia of pipe150mm.
M&L for preparation of new wood surfaces of any description and and treated with tar or coal tar black paint and sanding newly tarred surfaces with clean sharp sand.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/buzzer, bell push, lamp holders, regulators, sockets, light fittingsetc. removing materials from site and making good to the disturbed surfaces of walls, ceiling floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed.
Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connecting to earth dolly, including PVC rectangular box for mounting switches/sockets/regulators etc. with 3mm thick plastic laminated sheet cover of suitable size as required at site and 50 mm deep complete all as specified and as directed. Make:Richa/finolex/Havells/RR Kabel. Make of caping/casing & PVC boxes: Prestoplast/finolex/Supreme/Richa.
One light controlled by one, one way switch.
One 3 pin socket outlet 5 Amp on the same board with other switches
One 3 pin socket outlet 5 Amps on the Independent board.
All as per item No.113 here-in-before but with 2.5 Sqmm for 3 pin 15 Amps switch socket point on independent board along with one run of 2.5 Sqmm copper conductor green in colour as earth continuity conductor connected to earth dolly complete all as specified and as directed.
M&L for Switch Piano, flush type single pole, one way 5 Amps complete all as specified and directed. Make:- Anchor/Plaza/SSK/Hager
M&L for Socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed. Make:- Anchor/Plaza/SSK/Hager
M&L for Switch Socket combination 2 in 1, 3 pin 5A/16A, 5 in 1 flush complete all as specified and directed. Make:- Anchor/Plaza/SSK/Hager
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed.Make:- Anchor/Plaza/SSK/Hager
M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and as directed. Make : Havells Cat No LHFYBYPNIA1W022 Regal (batten) & LHDLEFXD5LR020(LED Tube) or equivalent in Bajaj/Philips
M&L for Lamp holder , PVC/ Polycarbonate type with PVC round/square block incl 9 watt LED lamp suitable for lamp holder fittings. Make :- Plaza/SSK/Hager Make of Lamp :- Havells/Bajaj/Philips
M&L for LED 1x20W building Security light fitting, drawn through including GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holes as required and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and directed. Make:-Havells Cat Pt No LHETBXU7PA6S020 or equivalent in Bajaj/Philips
S&F for ceiling mounted LED light fitting 42 Watt environmental friendly , new generation aestheticaly designed ultra modern recess mounting limonior with high brightness SMD LEDs as light sourse with all accessories pre-wired connecting up with new flexible copper cable of size 0.75 sqmm 3 core complete all as specified and directed. Make : Havells Ordering Code No PLUTONEO2X2PLR 42WLED 857S or equivalent in philips/Bajaj
S&F for exhaust fan AC single phase 230v 230mm sweep 1350 RPM double ball bearing with louvers metal body 03 Nos blades Insulation Class A including capacitor to ensure power factor more than 0.9 complete all as specified and directed by Engineer -in-Charge. Make : Havells
S&F Isolator DP 32 Amps rating 240 volts grade "C" curve conforming to IS and/or as approved by GE including taking down the old one complete all as specified and directed. Make Legrand/Schneider/L&T
M&L for MCB Distribution board double door type SPN 4 way, sheet steel, powder coated, with 200 Amps rated bus bar 415 V neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make:- Legrand/Schneider/L&T
M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder coated, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make:- Legrand Cat No 607711 or equivalent in ABB/Siemens
M&L for MCB SPN, 40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down complete all as specified and as directed. Make: Legrand Cat No 408636 or equivalent in ABB/Siemens.
M&L for MCB SP, 5 to 32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed. Make:- Legrand Cat No 408587-95 or equivalent in ABB/Siemens
Taking down LT UG cable/service connection of any size and M&L for laying of LT UG cable , XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm,2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. Make: Havells/Polycab/Phinolex/Richa
M&L for fine river washed sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
Supply and laying tubes light grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 40mm dia bore including taking out unsv GI tubing complete all as specified and as directed. Make: Jindal/Prakash surya/TATA
House service bracket (hook typecomplete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos 900 bends. M.S.hook and stay or guy complete.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm suspension wire one twine core cable flat or circular stranded conductor of size 16 sqmm.
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. (i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 with 10mm thick CI cover plate hinged to angle iron frame of suitable size, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type.
SHRI VIKASHE ZHIMOMI
Kalim sons
Shri Atoshe Tuccu
MS SADHNA RAHUL
SHRI MADAN SINGH
M/S RAHUL TRADING CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .