Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical All PQR Condition not Qualified |
| 5 | Rejected-Technical 108 BADA CHAKA NAINI ALLAHABAD | ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | Rejected-Technical All PQR Condition not Qualified |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
7 Feb 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Superintending Engineer, E.U.C.C (XI), LESA Tr
The Superintending Engineer, E.U.C.C (XI), LESA Transgomti Lucknow
Construction of Proposed 33/11 KV Substation Chinhat (Shivpuri) new 2x5 MVA Lucknow, under jurisdiction of EE, EUCD-I, LESA, Trans Gomti, Luknow
2023_MVVNL_769013_1
14/EUCC-XI/LESA(T.G.)/2022-23
Open Tender
Electrical Works
Fixed-rate
30 days
EE, EUCD-I, LESA, Trans Gomti, Luknow
As Per Tender Document
2 documents required · 2 mandatory
₹3,540
A/c. No. 00500200001389, IFSC CODE No. BARB0HAZARA
₹40,000
15 Feb 2023
24 Jan 2023
8 Feb 2023
24 Jan 2023
7 Feb 2023
24 Jan 2023
Amount
Carriage of all the concerning material from store center to JE's dump store& from dump store to the site work including loading,unloading and proper stacking at the site etc.
5 MVA T/F
33 KV 3x300 sq mm XLPE Cable
33 KV 3x300 sq mm XLPE O/D J/Kit
11 KV 3x300 sq mm XLPE Cable
11 KV 3x300 sq.mm Cable Jointing Kit I/D
11 KV 3x300 sq.mm Cable Jointing Kit O/D
11 KV 3x185 sq mm XLPE Cable
11 KV 3x185 sq mm XLPE O/D J/Kit
11 KV 3x185 sq mm XLPE I/D J/Kit
Single core cable 1x630 sq mm
LT PVC Cable 3.5x70 sq mm
Panther Conductor
33 KV VCB 800 Amp 750 MVA
Double T/F Control Panel
Double Feeder Control Panel
11 KV VCB I/C CTR 600/300/5 amp, 350 MVA
11 KV VCB O/G CTR 200/100/5 amp, 350 MVA
Bus Coupler 350 MVA
33 KV LINE ISOLATOR 400/800 A
33 KV Lightening Arrestor
33 KV BUS ISOLATOR 400/800 A
33 KV Pin Insulator
33 KV CT 200/100/1 amp
33 KV CT 400/200/1 amp
33 KV Pin with nut
ST Pole 11 Mtr Long
ST Pole 9 Mtr Long
11 KV Disc Insulator B&S Type 70 KN
Disc Fittings Dog/Racoon 70 KN B&S
11 KV Pin Insulator
11 KV Pin with Nut
MS earthing rod
Steel Materials
LT PVC Cable 1x240 sq mm
Rail 105 Lbs 9 Mtr Long
MS Round of 32 mm dia
Battery Charger 24 Volt
Battery Set 24 Volt
Fabrication of switchyard fencing with wire mesh 10SWG(37mmx50mm) along with Fabrication of one number gate made of MS Angle, MS Channel, MS Flat together with locking arrangement, its Installation including the cost of civil material, angle 50x50x5mm. (All materials provided by contractor)
Earth Laying of earth mat in the switchyard by laying of M.S. Round of 32 mm dia in 500 mm deep trenches with M.S. Round 32mm dia,3 Mtr. Long earth electrodes as per drawing. The work includes welding of the M.S. Round ,connecting all steel structures in the switchyard with the earth mat by means of G.I. strips of size 50x6mm as per item below.( M.S. Round bar 32mm provided by Department )
Excavation of earth for laying mat
Driving of earth electrode.
Laying of earthmat (M.S.) Bar including cutting, shaping and binding etc)
Preparation of joints, proper making and welding; of main earthmat bar joints and applying bitumen, bitumen impregnated on joints i.e. End Joints. Cross Joints, Lap Joints.
Welding of riser strip with earthmat and structure body.
Construction of plinth of size 3x4 Mtr. for Power T/F having 0.4 Mtr. above ground level and 0.9 mtr below ground level . The work including excavation of foundation base concreting in CC 1:6:12 ratio (cement ,fine sand & brick ballast)first class brick work in cement morter of ratio 1:4 foundation CC in 1:4:8 ratio (cement ,fine sand & brick blast) and RCC working ratio 1:2:4 (cement ,coarse sand and stone grit of 20mm gauge using MS Bars of 10mm dia( tor ) in reinforcement including its cutting ,bending &binding in required shape .The work also includes laying of 2 No. 4 Mts. long each rail pieces complete with cutting & proper fitting etc. The plinth will be plastered/ finished on top and sides of the plinth .
Fabrication & erection of Isolator stucture as per RESSPO Norms. (steel material provided by deptt.)
Fabrication & erection of L.A. & C.T. stucture as per RESSPO Norms. (steel material provided by deptt.)
Construction of plinth of size 2.0 mtr x 1.5 mtr x 0.9 mtr suitable for erection of upper structure for 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:6:12(cement, fine sand & brick ballast ),1st class brick work in cement mortor of ratio 1:4 CC in ratio 1:4:8 and RCC work in ratio 1:2:4 (cement coarse sand and stone grit of 20mm gauge )as per RESSPO norms.
Erection and installation of 33/11kV, 5MVA transformer in a levelled position on the plinth. The work includes shifting of transformer to the site of installation within the substation premises, assembling fixing and fitting of all accessories and filling of transformer oil to the desired level and ensuring that there is no leakage. Providing & fixing Copper.L-piece 07 no.for transformer. All the jumpering & connection are included in the scope of work.
Earthing by way of boring and lowering of "B" class GI pipe 50mm dia from ground upto the water level (minimum 30 meter deep) as per standard practice
Fabrication and grouting of M.S Angle 75x75x6 or 65x65x6mm in L shape & in proper size and alignment to provide support for the separate earthing strips for power transformer neutral including supply and fixing of flexible copper bonds for neutral earthing. (Steel provided by diptt.)
Fabrication & eretion of Cable stand as per RESSPO Norms. (steel material provided by deptt.)
Assembling and installation of line /bus isolator on the isolator structure, In case of line isolator proper operation of earth links shall also be insured. The work includes fabrication for proper flexing if required.
Assembling and installation/ Mounting of lightning arrestors on the L.A.Structure as per Resspo norms.
Installation of CTs on the CT structure, along with C.T. Junction box .(Junction box to provided by controclor).
Installation of 33KV VCB- complete work including commissioning.
Jumpering with ACSR panther coductor of all equipments in swicth yard with P.G. clamps & proper size aluminium lugs.
Providing & fixing of connector & L pieces for CT,isolator & T/F which will be required etc.
Shifting carefully & safely 11KV B/C , I/C & O/G switchgear from outside of the switchgear room in proper position and alignment and checking-complete work with Mounting of P.T on incoming Switch gear.
Fixing and making bus bar connections in between all switchgears after cleaning and taping with H.T. Tape, empire tape and PVC tape properly. Providing and fixing of 6 mm thick Bakelite separators and plugging of all opening & holes with plastic compound-complete work including cost of all material (except copper Bus Bars)strictly to the satisfaction of site in- charge.
Fixing and connecting of all outgoing/incoming 11 kv cables with all switchgears and taping with H.T. Tape, empire tape and PVC tape properly(strictly to the satisfaction of site in- charge).
Shifting carefully & installation of 33KV single/double circuit/Feeder control panel in control room including its grouting.
Earthing of indoor equipments by means of M.S strip 50x6mm & connecting to Pipe boaring type earthing as per RESSPO norms. Joints will be welded with high quality arc welding.
Cable laying D/C in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. (All the material required for laying will be supplied by the contractor except XLPE cable). Spare cable shall be left and burried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making rings and sealing both ends of the cable.
Laying of XLPE Cable Single circuit in normal soil by digging of trench 1050 mm deep, 500mm wide including supply of required material, 1st class bricks, stone pad & fine sand and back filling of digged trench and proper leveling after laying of cable. (All the material required for laying will be supplied by the contractor & 33 KV XLPE cable will be supplied by the department)
Cable laying in existing trench S/C all size cable.
Hoisting of 11 KV cable on 11 switchgear & Cable Stand.
Hoisting of 11 KV cable on D/P with MS Pipe 4" dia including jumpering and clamping.
High Pressure testing of XLPE cable. Testing equipment will be arranged by the contractor.
Provided and Fixing of LED flood lamp complete fittings, (standard quality ISI mark with water tight fittings, elbow etc.)on above suppots.
Erection of 9 Mt. STP after excavation of earth in any type of soil and grouting of CC in ratio 1:4:8 (cement,coarse sand & brick ballast) With plinthing as per RESSPO Drg.
Providing and laying of 2 x 6 sq. mm. aluminum cable from S.G. room to street light supports after digging of trench, laying of cable,providing a brick on top of cable , refilling of trench, making connections at poles with street light fittings, complete in all respect. ( cable provided by the contractor as per site engg. instruction).
Construction of cable trench of size 300x300 mm with welded frame type control cable trench cover suitable for trench including cost of MS/Torr Bar.
Providing and Laying of following size copper, control cable through underground/cable trench/trenching SGR interlinking through proper connections to transformer control panel/protection board /Battery and Battery Charger/Relays 33/11 KV Transformer junction box/ 33KV VCB ,CTs etc as per site conditions.
Providing & installation of control cable tray.
Painting of all structures & equipments.
Brick on edge soling in switch yard complete works including material and labour ..
Carefully shifting of existing panels etc. (which will be required) for making space in the control room as per instruction of site engineer , due to installation of new panels including opening controll cable and after shifting reconnection properly with construction of base. (All materials provided by contractor which will be required as control cable etc. for shifting.)
Opening and shifting of 11 KV cable from the existing 11 KV O/G VCB panel to new installed 11 KV O/G VCB panel with hoisting and connecting. (All materials provided by contractor which will be required for shifting as Straight through and Indoor J/K.)
Levelling and cleaning of proposed switchyard including cutting of plants with its roots and dump misc. items as per instruction of site engineer .
Soil filling in the proposed switchyard. (40x40x.3) mtr qube.
Dismantaling of poles and other structure from the proposed new swithyard and carriage to store.
Installation of 24 Volt, 15 AH sine wave Battery and battery Charger Complete and including its commisioning. (Battry & battry charger provided by diptt.)
Fabrication & erection of 11 KV cable exposure type double pole with the provission of separate bus bar for each cable with fixing of necessary clamps and other acessories like danger board,number plate,barbed wire, 9 no. pin insulators with pins,2 no. channels 100x50 mm (1600mm each),1 no.MS channel 100x50mm(3200mm in length) and 2 no.MS angle 65x65x6 mm (each 3200mm in length ) for supporting the hoisting of cable & poles.Its jumpering by single core PVC aluminium cable with proper size of lug.(all material to be arranged by contractor except steel,pole,PVC aluminium cable,Pin & Pin insulator).as per RESPO norms. .
Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms.
Construction of pole plinth 300mm x 45mm above ground level in 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms.
Painting of ST pole with one coat of red oxide & two coats of best quality top 2 mtr PO Red paint and remaining Al. Paint ISI mark as per RESPO norms.
Fabrication, erection, & grouting of Bus bar gantry using rail pole and channel as per RESPO (All materials provided by contractor except steel ,rail pole )
Laying and spreading of 3.5 x 150/70/35 Sq.mm PVC LT cable from 63 KVA T/F to LT Distribution Board in switchgear room after digging the trench, laying cable and refilling of trench including connection at both ends after providing and crimpling of lugs of proper size,complete work.
Stringing of 33KV bus bar with ACSR Panther Conductor including fixing of Disc insulators, strings and tension fitting complete with sagging of bus bar etc. and making vertical/Horizontal jumper connections through PG Clamps and connecting all the equipments with each other through connecting clamps.Work includes all the jumpering from cable stand to bus bar and from bus bar to transformer as per RESPO (All materials provided by contractor except , disc insulator and disc fitting )
Providing & fixing auxiliary itemss like Table,chair,almirah & lighting board with swicth,socket,MCB & indicator(R,Y,B) etc. (All material shall be provided by the contractor except the supplied items) as per RESSPO Norms/Schedule No. 48.
Office table wooden
Office chair wooden
Bench wooden
Wall clock
Steel almirah
Notice borad
Max - min load record
Key board
Fire extinguisher
Fire bucket 6 no. with stand
LT Distribution Panel for S/S supply
Rubber matting sheet 8/10mm thick 2x1.5 mtr
M/S SMM INFRATECH PVT Ltd
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .