Superintending Engineer
ELECTRICITY URBAN DISTRIBUTION CIRCLE, BUNGLOW NO.-9, OLD POWER HOUSE COLONY, RAILWAY STATION ROAD, GORAKHPUR
WORK OF REGULARISATION OF BANS-BALLI AND SHIFTING OF HT OVERHEAD LINES AT DIFFERENT PLACES IN URBAN AREA OF GORAKHPUR DISTRICT
2020_PVVNV_513162_2
36/EUDC(G)/2020-21
Open Tender
Electrical Works
Lump-sum
90 days
URBAN AREA OF GORAKHPUR DISTRICT
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Superintending Engineer, EUDC, Gorakhpur
₹5.8 L
5 Nov 2020
24 Sept 2020
13 Oct 2020
24 Sept 2020
12 Oct 2020
24 Sept 2020
Amount
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
ST Pole 11 Mtr. Long
ST Pole 9 Mtr. Long
PCC Pole 8.5 Mtr.
ACSR Dog Conductor
ACSR Weasel Conductor
Earthing Complete
Stay complete with 5 Kg. wire
11/0.4 KV 250 KVA Transformer
11/0.4 KV 100 KVA Transformer
LT Cable 1X240 Sq.mm.
LT Cable 1X120 Sq.mm.
11 KV Pin Insulator with fitting
11 KV Disc Insulator with fitting
11 KV Sub station base Angle
11 KV Dropper Angle
11 KV Top Channel
11 KV V Type X arm
Supply of following material/fitting of HT/LT Line complete in all respect as per site requirement-
11 KV ABC (3X120+100) Sq.mm. Cable
LT ABC (3X50+1X35+1X16) Sq.mm. Cable
Cable Jointing Kit for 11 KV ABC (3X120+100) Sq.mm. Cable
Distribution Box with Clamp (Distribution box shall be made from 20 SWG CRCA sheet by Deep Drown method with powder coating & size of box shall be 225 mm X 285 mm X 120 mm (Roof of the box shall be tapered on both sides to drain the rain water)
Distribution Box with Clamp (Distribution box shall be made from 20 SWG CRCA sheet by Deep Drown method with powder coating & size of box shall be 418 mm X 300mm X 120 mm (Roof of the box shall be tapered on both sides to drain the rain water)
Galvanised angle with clamp used for fixing 11 KV ABC (3X120+100) Sq.mm. Cable
Insulated Dead end/Anchor clamp for 11 KV ABC (3X120+100) Sq.mm. Cable
Suspension, clamp with I hook (Insulated) for 11 KV ABC (3X120+100) Sq.mm. Cable
Insulated Dead end, clamp with I hook for LT ABC (3X50+1X35+1X16) Sq.mm. Cable
Suspension, clamp with I hook (Insulated) for LT ABC (3X50+1X35+1X16) Sq.mm. Cable
LT insulated Piercing connector
XLPE 1X35 Sq.mm. Al. cable for energizing D.B.
LT Clamps For PCC/STP Pole
LT Shackle Insulator
Holding Clamps
F-Bracket
Aluminium Lugs
Copper Z Clamps
Nut & Bolts off size
Top Channel 125X65mm, 500 mm with clamps
The excavation of foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of Pole with fixing of necessary clamps & accessories as per required. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). In case of ST Pole making Plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
PCC pole 8.5 meter long
STP pole 11 meter long
STP pole 9 meter long
Laying, stringing, sagging, binding and jumpering of conductor for LT/11 KV/33KV Line with fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size as per required.
ACSR Dog Conductor
ACSR Weasel Conductor
Laying, stringing, sagging, binding and jumpering of ABC (3X120+100) Sq.mm. Cable of 11 KV Line with fixing of accesiories such as Insulated Dead end/Anchor clamp, Suspension clamp with I hook(Insulated), Top Channel, Disc insulator with fitting
Laying, stringing, sagging, binding and jumpering of ABC (3X50+1X35+1X16) Sq.mm. Cable of LT Line with fixing of Distribution Box with Clamp, Insulated Dead end clamp with I hook, Suspension clamp with I hook(Insulated), LT insulated Piercing connector, XLPE 1X35 Sq.mm. Al. cable for enerzing DB, XLPE 1X16 Sq.mm.
Errection of Cable Jointing Kit FOR 11 KV ABC (3X120+100) Sq.mm. Cable
Painting of ST Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Earthing of Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Disconnection and Re-connection of consumer cable of complete LT Line (Single/Three Phase)
Construction of T/F plinth of size 1.8x1.8x1.2 mtr with the help of first class brick & 9" masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely and plastering outer surface as per RESPO norms. Top of the plinth covered with 4" RCC Slab of ratio 1:1.5:3 (Cement, sand & concrete) grouting with 2 Nos. ISMC size 125X65X6 MM (confirming to IS 808:1989) of 1800 mm long for resting. All required materials will be provided by the contractor.
Grill fencing of 11/0.4 KV S/S shall be made of rectangular of size & height approx 3 meter as per site requirement with fabrication 50X50X5 mm angle the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of grill, having a gate on road side must have provision of locking arrangement. The work is including painting of fencing as per norms. Work will be done as per RESPO specification.
Fabrication, errection, commissioning & Testing of T/F on Double Pole/Plinth with all accessories including make its LT and HT connection.
Chemical earthing of Transformer (Body+Neutral) as per IS Code 3043 - 1987 specification
Videography & GPS survey of Site before starting of work
Videography of site after completion of work
Dismantling of following Line materials and safe loading, unloading and carraige of dismantled material from work site to departmental store (As per site requirement)
STP pole 11/9 meter long
ACSR Dog Conductor
JRA POWERGEN LLP
A K Engineers
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .