Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAccepted-AOC | ₹4.9 Cr | L1 | Accepted-AOC Being lowest and reasonable. |
| 2 | L2₹5.2 Cr+₹34.3 L (7.01%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹5.2 Cr+₹34.3 L (7.01%) | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹5.4 Cr+₹49.2 L (10.0%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹5.4 Cr+₹49.2 L (10.0%) | L3 | Rejected-Finance Other than lowest. |
| 4 | L4₹5.5 Cr+₹57.8 L (11.8%)Rejected-Finance 583 URBAN ESTATE II HISAR 125005 | HISAR | HISAR | HARYANA | 125005 | ₹5.5 Cr+₹57.8 L (11.8%) | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹5.5 Cr+₹64.9 L (13.2%)Rejected-Finance | ₹5.5 Cr+₹64.9 L (13.2%) | L5 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹5.1 L
Closing Date
11 Feb 2023, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer Delhi Zone, Delhi Cantt-10
PROVN OF INTEGRATED DATA RECEPTION AND CONTROL STATION AT DIPAC UNDER GE (P) EAST DELHI CANTT-10 PROVN OF INTEGRATED DATA RECEPTION AND CONTROL STATION AT DIPAC UNDER GE (P) EAST DELHI CANTT-10
2022_MES_570494_1
CA No CEDZ/TOKEN-56 of 2022
Open Tender
Civil Works
Lump-sum
450 days
Delhi Cantt
MES contractor enlisted in MES under class A cat a i having deposited Standing Security of Rs 700000.00 with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹3,000
GE (P) East Delhi Cantt
₹5.1 L
Yes
25 Mar 2023
21 Dec 2022
13 Feb 2023
21 Dec 2022
11 Feb 2023
28 Jan 2023
21 Dec 2022 - 16 Jan 2023
Amount
FIRE ALARM SYSTEM Supply installation, Testing and Commissioning of networkable 2 Loop Micro processor based fire alarm panel, 2 wire fault tolerant loop shall have the capability of connecting 126 device. The fire alarm control panel shall have built in degrade mode function. The panel should have inbuilt TCP/IP communication. The panel shall be able to give location of all fire and more Fire / fault and Isolation conditions of addressable units via the address codes. The panel shall have the capacity of storing upto 2000 events. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel should have protection category of IP30. Also the panel should have the option to operate in manned and unmanned mode. The Panel should have the option of 24/48/96 Zones with individual LED indicators or with in the Loop mimic driver for 96 LED indicators. The panel shall have built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volts SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required and as per specifications and duly Approved by EN54/LPCB/VDS/FM. Make - Siemens/Tyco/Notifier.
Supply installing Testing & commissioning of analogue addressable multi sensor detector with the hard addressing feature with standard base and junction box wherever required Detector shall be with visible bi-color LED for 360 viewing . Complete as required as per technical specification and directed
Supply installation testing & commissioning of Dual action Addressable manual pullsatation with addresseable switch to program the modules which monitors and reports contact status complete as required as per technical specification .
Supply installation testing & commissioning of Addressable control module shall be with the facilty of hard addressing capable of providing DPDT contact rated at 24 v DC, 2A complete as required as per technical specfication
Supply installation testing & commissioning of Addressable monitor module shall be with the facilty of hard addressing capable of providing DPDT- contact rated at 24 v DC, 2A complete as required as per technical specfication
S&FFire Alarm sounders / Sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 500 meter range complete all as specified and directed
S&FShort circuit isolators complete all as specified and directed
S&FRemote response indicators complete all as specified and directed
S&F 2Core, 1.5 sq. mm. FRLS Copper Armoured cable complete as required
UPS WITH PDU Supply, installation, testing and commissioning 60 KVA (3P in 3 Ph out) online UPS with PDU, BCB inbuilt isolation Transformer with Backup Time 30 Min, Online UPS 60 kVA in parallel (3in – 3out) with parallel (optional) provision, Upto 6 units in parallel, SNMP Card – 01 Nos, Battery link & Accessories & Battery rack -01 Nos, Battery link & Accessories & Battery rack -01 Nos, 1 Set of 34 x 12 V/ 150 AH Batteries - 34 Nos make- Exide, Battery Rack -01.
Input Input voltage range - 290 to 498Vac Nominal input frequency - 50 Hz Input frequency range - 45-55Hz/55-65Hz Input current distortion with linear load - 0.05 Power factor - 0.9
Output Nominal output voltage - 400V+ 10% AC - 3 Phase with Neutral
Frequency Voltage stability - ±1% (Steady state); ±5% (Transient state) Transient recovery time - 20 milliseconds + 1% Frequency stability - ±0.1% (Synchronized with internal clock); ±6% (max)(Synchronized with bypass) Overload capability - 101-110%, 60minutes; 111-125%, 10minutes; 126-150%, 1 minute; Voltage distortion with linear load - <1% Voltage distortion with 100% Non- linear load - <5% Permissible load unbalance - 1 Non linear load capability - 1 Load handing capability without kVA derating - 0.5 lagging to 0.9 leading K Rated Isolation Transformer - Inbuilt Maintenance Bypass/Static Bypass - Inbuilt
General General and safety requirements for UPS - EC 62040-1-1 EMC requirements for UPS - IEC 62040-2 Design & Test Methods (1999) - IEC 62040-3 Battery Type - Sealed Maintenance Free(SMF) -Type DC Bus - 408VDC Backup Time - 61200VAH for 30min backup time Efficiency at 100% load - 91.90% Warranty - 12 month on UPS & 24months on battery
EXTERNAL ELECTRIFICATION Supply. installing, testing and commissioning outdoor type step down transformer, 11 KV/433 volts (at no load) AC 3 Phase 50 Hz 315 KVA capacity, core copper wound, oil immersed, naturally cooled, ONAN with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV side) and having tapping at +5% to -10% in Step of 2.5% on HV site to be changed by means of hand operated off load tap changer gear.The transformer shall be confirming to IS-1180, BEE star rating not less than 4, Percentage of impedance 4.5% and chain link fencing with standard fittings and shall comprise etc. complete all as specified and directed of the following :-
(a) One cable box for HT connection, three Nos procelain bushing suitable 11 KV on HV side, complete with copper rods, nuts and washers
(b) One cable box on LT side (secondary side) consisting of connection through Bus Bar Trunking/cable termination
(c.) Oil conservatror with filter type drain valve and oil level guage
(d) De-hydrating breather with first fill of dehydrating agent (SfIlica gel)
(e) Explosive vent, Thermometer pocket on tank cover oil level gauge, oil drain drgs forfilter valve, lifting lugs, oil filling hole with cap/plug with connection plate complete, all Air release valve plug and four nos plain soild cast steel detachable rollers.
(f) Oil temparature meter and winding ternparature meter having range 0-120 degree celsius with maximum size indicator.
(g) Two earthing terminals on tank cover to facilitate fixing for earth stirp earthing of body.
(h) Rating plate and terminal marking plate.
(J) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
(K) First filling of new and unused transformer oil, filtered and tested upto 60 KV dielectric strength at 2.5 mrn air gap between testing electrodes.
(I) Lifting lugs
(M) Pressure release valve.
Supply, installing, testing and commissioning of Lt Automatic power factor panel 100 KVAR, outdoor type, 10 Steps of 10 KVAR each having switching sequence 1:1:2:2:2:2, Shall be dust and vermin proof, protection class (IP-65) and made of 3.0 mm thick CRCA Sheet & suitable frame work/ support made out of 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multi stranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade The scope of work also comprising of the following: -
(a) Microprocessor based MCCB, 3 Phase of required rating, MD-XL capacity capacitor 440V rating, heavy duty capacitor switching contactor; Microprocessor based intelligent power factor corrector relays. The APFC panel shall have following safety features over voltage/ under voltage protection, short circuit protection, No volt release feature to immediately disconnect all capacitors in the event of power failure & automatic resetting after restoration of electric supply.
Note: The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specifically excluded. The equipment shall conform in all respects to high standards of engineering design and workmanship and shall be capable of performing in continuous operation.
Supply, installation, testing and commissioning of factory made powder coated compartmentalized cubicle type LT Panel outdoor type of appropriate size and fabricated from 3 mm thick CRCA sheet steel with necessary MS angle iron frame work(50X50X6mm), weather proof, vermin proof, suitable rating copper bus bar chamber for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing terminals, labeling , cable alley suitable for termination of cables including supply and fixing of following switchgear and accessories in the panel complete as required size conforming specification as per IS 5039. The panel should be CPRI approved and having IP 54 ingress protection including necessary foundation for mounting all as specified and directed by Enginer in charge. (Main LT panel outdoor)
Incoming
ON LOAD change over switch 415V,4 pole of capacity 630 Amps -01 Nos
Outgoing :-
(i) MCCB 4 pole, 250 Amps,50Hz,415 Volts, 50 KA ( for VRF Panel) -01 Nos
(ii) MCCB 4 pole 400 Amp 50 KA 415V ( for APFC ) -01 Nos
(iii) MCCB 4 pole 250 Amp 35 KA 415V ( Bulding VTPN for light/fan/5 & 15 Amp Point) -01
(iv) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets
(v) CopperBusbar: 1200 Amps, System Voltage: 415V, 50 Hz, 4W +E
(vi) ON — Space for MCCB
Supply, installation, testing and commissioning of factory made powder coated compartmentalized cubicle type LT Panel outdoor type of appropriate size and fabricated from 3 mm thick CRCA sheet steel with necessary MS angle iron frame work(50X50X6mm), weather proof, vermin proof, suitable rating copper bus bar chamber for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing terminals, labeling , cable alley suitable for termination of cables including supply and fixing of following switchgear and accessories in the panel complete as required size conforming specification as per IS 5039. The panel should be CPRI approved and having IP 54 ingress protection including necessary foundation for mounting all as specified and directed . (VRF LT panel outdoor)
Incoming
Outgoing :-
(i) MCCB 4 pole 63 Amp 16 KA 415V (For VRF outdoor 28 HP) -03 Nos
(ii) MCCB 4 pole 40 Amp 16 KA 415V(For VRF outdoor 12 HP) -02 Nos
(iii) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets
(iv) Copper Busbar: 600 Amps, System Voltage: 415V, 50 Hz, 4W +E
(v) ON — Space for MCCB
LIGHTENING PROTECTION M&L for Earthing complete with copper earth plate electrode 600x600x3.15mm thick burried directly in ground (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to copper strip 32x6 mm as earth lead by means of bolts nut check nuts and washers of galvanised iron or steel necessary earth work, drilling hole, RCC cover with handle, GI tubing medium grade 50 mm dia for watering, funnel with wire mess GI bolts with washer of suitable size all as shown in electrical plate No 3 connected to earth test point all as specified or indicated incl. testing on completeion.(Note: Fresh soil will be used for filling the dug as required to achieve the desired resistance from out side, copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item copper strip beyond 7.5 RM will be measured and paid separately).
AIR CONDITIONING & VRF SYSTEM (VRF UNIT BMS compatible ) Supply, installation, testing and commissioning of 100% Inverter VRF units complete with Inverter Scroll compressor fitted with Conentrated winding, air cooled condenser with low noise fan having interconnected control wiring and refrigerant piping housed in compact housing duly powder coated, Conformal Coating on PCB, Hydrophilic Blue Fins, Accumulator & Two Compressors in each Outdoor Unit from & Above 14HP Capacity of following capacities. ( Cooling & Heating ) - Eco Friendly Refrigerant (R-410a) (a) 100% Capacity Delivered without deration upto 43°C Ambient Temperature (b) No unloading of compressors upto 48°C (c) Operating Outdoor Ambient Temperature Range= Cooling 10°C to 56°C & Heating -10°C to 24°C (d) IPLV more than 6.7 (e)Two Compressor in each Outdoor Unit from & Above 14HP (f) All above Detail to be submitted by OEM Only on there letter Head with Authorisation Letter from OEM (g)All VRF Installation work to be execute by OEM or OEM Authorized Vendor Only & the equipment shall have 2 year warranty as well as 3 year AMC. (a) Capacity :- 28HP
(b) Capacity :- 12HP
(INDOOR UNIT) Supply Installation Tesing & Commissioning of units with evaporator coil,fan and Fan motor . The units shall be of following capacities : Cassette Units with Decorative Panels & Inbuilt Drain Pump (a) Capacity :-3.2TR
(b) Capacity :-4.0TR
Hiwall Units (a) Capacity :-2.0TR
(b) Capacity :-2.5TR
(c) Capacity :-2.8TR
Supply of Cordless Remote Control
Supply, installation, testing and commissioning of Y Joints with different size as per final approved drawing which will be submitted by OEM only complete all as specified and directed
Supply of Split Ac units complete with High energy Efficient Rotary compressor fitted with Conentrated winding, 100% copper, air cooled Anti Corrosive condenser, Blue Fins,with Anti Rust Coating on Outdoor Unit, with low noise fan having interconnected control wiring and refrigerant piping housed in compact housing duly powder coated,1 phase Power Supply of following capacities. (Cooling Only ) - Eco Friendly Refrigerant - Capacity 2Tr complete all as specified and directed
Supply, installation, testing and commissioning high pressure interconnecting refrigerant pipe of following sizes including civil work like wall opening for copper and drain pipe for VRF system with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications. All Piping intall on cable trays with cover for outdoor locations as per OEM recommendations and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while making brazing joints complete all as specified and directed: - (a) 9.5 mm with 13 mm thick insulation
(b) 12.7 mm with 13 mm thick insulation
(c) 15.9 mm with 13 mm thick insulation
(d) 19.1 mm with 13 mm thick insulation
(e) 22.2 mm with 19 mm thick insulation
(f) 28.6 mm with 19mm thick insulation
(g) 34.9 mm with 19 mm thick insulation
(h) 41.3 mm with 19 mm thick insulation
Supply, fixing, testing and commissioning of the control wiring ( Sheilded Wire) from outdoor to indoor units with all necessary accessories to make it functional as per OEM Recommendation complete all as specified and directed (a) 2 Core x 0.75mm²
S&F Rigid PVC piping complete with fittings, supports and duly covered with 9 mm thick closed cell nitril rubber insulation complete all as specified and directed. Note : Providing and fixing in position the following size of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary "U" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category. (a) 32mm dia pipe (NB)
S&F MS Outdoor Stand as per OEM Recommendation complete all as specified and directed
Supply, Charging of Refrigerant Gas R410a as per OEM Recommendation complete all as specified and directed
Supply, Laying, jointing and testing of FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 40mm dia as per IS 694 with Cable Tray complete all as specified and directed (a) 3Core x 1.5mm² for Indoor Unit (Copper)
(b) 4Core x 10mm² for Outdoor Unit (Copper)
(c) 4Core x 16mm² for Outdoor Unit (Copper)
S & F MCB TPN 20 to 63 Amp complete all as specified and directed.
S & F MCB SP 2A to 40A complete all as specified and directed.
M&L for Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strip complete all as specified and directed
2 Run of 8SWG GI Earth wire for Each Outdoor Units complete all as specified and directed
AIR CURTAIN Supply, install, commissioning and testing of commercial air curtain unit for prevention of dust and conditioned air losses, Air curtain (Velocity 16-18 m/s) 2100 mm x 208 mm x 230 mm, 20 G, MS Powder coated body fitted with 1/5 hp / single phase three motors & five 125 x 125 mm ABS 920 Blowers complete all as specified and directed
Supply, install, commissioning and testing of commercial air curtain unit for prevention of dust and conditioned air losses, Air curtain (Velocity 16-18 m/s) 1200 mm x 208 mm x 230 mm, 20 G, MS Powder coated body fitted with 1/5 hp / single phase two motors & four 125 x 125 mm ABS 920 Blowers complete all as specified and directed
Supply, install, commissioning and testing of commercial air curtain unit for prevention of dust and conditioned air losses, Air curtain (Velocity 16-18 m/s) 1500 mm x 208 mm x 230 mm, 20 G, MS Powder coated body fitted with 1/5 hp / single phase three motors & five 125 x 125 mm ABS 920 Blowers complete all as specified and directed
RODENT REPELLANT SYSTEM Controller for Rodent Repellent System for Datacentre & PAC Room UL/CE approved, Power consumption:15W approx complete all as specified and directed
S&F Transducers/satellite units - Power output:800mW,Voume:3 cubic inches complete as required complete all as specified and directed
S&F MS bracket to house the controller complete as required
S&F Wire for connection between controller and transducer complete as required
S&F 25mm dia FRLS PVC conduit complete as required
GAS SUPPRESION SYSTEM -SITC of Sinorix 1232 System UL Listed Novec 1230 - Novec (kg); Manufactured by 3M, USA with 20 years free replacement Blue Sky warranty, if government bans due to ODP, GWP. Novec 1230 shall meet the NFPA 2001 latest standards. CONTRACTOR TO FURNISH GAS ORIGIN & INGENUINETY CERTIFICATE FROM THE OEM (COUNTRY OF ORIGIN SHOULD NOT BE CHINA
946 Litre capacity bulk storage tank Assembly. Novec 1230 clean agent fire suppression liquid, as per NFPA 2001 shall be stored at Atmospheric Pressure. The tank shall be Fabricated to ASME Boiler and pressure vessel code Section VIII. Operating pressure of tanks shall be from 25 bar to 34.5 Bar. Tanks shall be fitted with Level Indicator. Systems shall be IoT(Internet of Things) enabled for continuous level/pressure monitoring (Optional). The Zero pressure Novec 1230 storage tanks shall be refillable at site using diaphragm fill pumps from OEM supplied Novec 1230 drums. Provision for connecting Nitrogen Pilot Cylinders to the tank shall be available. System shall be UL Listed.
180/360 Deg Nozzle 1/2", UL Listed with orifice plate to suit the design flow as per NFPA 2001. Material Aluminium/brass complete as required
180/360 Deg Nozzle 1.5", UL Listed with orifice plate to suit the design flow as per NFPA 2001. Material Aluminium/brass complete as required
Pilot Hose Adapter for connecting to Pneumatic/manual release.Material: Brass. Complete as required
Nitrogen Pilot seamless 80 L Cylinder/Valve Assembly. Operating pressure of 200/300 Bar. CrMo Steel construction. UL Listed, PESO,Govt of India approved.
High Pressure Electrical Actuator, 24 VDC, UL Listed complete all as specified and directed
Monitor for Electrical Actuator complete all as specified and directed
High Pressure Mechanical Actuator, UL Listed complete all as specified and directed
Fitting for 1/4" Hose to Master Pneumatic Actuation complete all as specified and directed
High Pressure Pneumatic Actuator, Brass, UL Listed complete all as specified and directed
Pilot Hose 700mm for N2 Pilot cylinder complete all as specified and directed
Pilot Hose Union complete all as specified and directed
Pilot Hose Bleed Valve complete all as specified and directed
Check Valve Ø3" Groove - Groove, UL Listed complete all as specified and directed
Reset Tool, Material: Brass, for Elec-mag Actuator complete all as specified and directed
1" Manifold Relief w/Rupture Disc complete all as specified and directed
Caution Label "When Alarm Sounds" complete all as specified and directed
Caution Label "Keep Door Closed" complete all as specified and directed
Caution Label "Operation of Manual Pull…" complete all as specified and directed
Pressure and/or level monitoring of Novec 1230 system shall be by using Internet of Things (IoT) Ultra Gateway with Wi-Fi / GPRS communication. Gateway shall be complete with Power supply, battery and in built charger. The pressure/level switch shall be wired to IoT Gateway and Gateway shall communicate with Cloud using Wi-Fi/GPRS. The IoT system shall be with App capability for notification of alarm/trouble by "email" and "smartphone-sounder" on designated client's Mobile phone/Tab etc. The Dashboard shall have a feature wherein an Escalation Contact can be provided ( in case within 1 minute the Alarm is Not acknowledged this contact will be notified by email). Reports shall be accessible by the client on a Dash Board. The Gateway shall be with unique ID, password and configurable with minimum of two security access levels. The IoT Gateway shall be with minimum of 4 Signal inputs like pressure, level, temperature etc. from Potential free contacts. The IoT System supplied shall be with minimum 3 years subscription and technical support.
4 zone UL Listed Gas Release panel for Novec 1230 system with minimum of 2 detection Zones for cross Zoning and One Agent release Zone. The panel display shall be LCD 2 X 16 Matrix type. 220 VAC main power supply with 24 VDC battery and charger shall be provided. 3 X 24 VDC Monitored outputs shall be inbuilt for fire, cross zone, Gas release sounder. Programmable delay timer, power to the solenoid actuator, zone enable/disable switch, maintenance isolation switch shall be inbuilt. Programmable Main and Reserve change over switch shall be inbuilt. RS 485 and MODBUS Connectivity shall be available on the release panel. 1 Manual Release station, 1 Manual Abort station, and 2 Horn/strobes shall be part of Panel kit.UL Listed
Conventional type hooter cum strobe complete as required
Conventional type photoelectric smoke detectors complete as required
Response indicator complete as required
Manual call point complete as required
Manual release switch complete as required
Abort switch complete as required
2core,1.5 sq. mm FRLS Copper armoured cable complete as required
ASTM A53, Sch 40 Grade B, Pipes and fittings for the Project. Complete with all the supports and special items if any required. Complete as required
Installation testing and commissioning charges
WATER LEAK DETECTION SYSTEM Supply, Installation, Testing and Commissioning 4 zone water leak detection system control panel, with battery as required complete all as specified & directed
Supply, Installation, Testing and CommissioningWater Leak Sensor/Detection Cable - PVC twisted pair with Stainless 316 elements, 3.5mm dia, country of origin: UK complete as required complete all as specified & directed
Supply, Installation, Testing and CommissioningHooter for water leak detection system complete all as specified & directed
S&F 2 Core, 1.5 sq. mm FRLS armoured copper cable complete as required
9) Operable with 230V AC supply (100V-305V AC range) and 24V DC (optional). Operating temperature must be rated at: -20 to +70°C10) Capable of capturing data from building assets such as VRF, fire alarm system, UPS, various analog/ digital sensors, multi-function meters and relay status data along with Run Hours as well as other fields from any compatible building/ substation/ metering equipment 13) CERTIFICATION: DDC controller conforming to the following IEC certifications from an NABL approved laboratory.- Conducted and Radiated Emission Test as per CISPR 22:2018- Electrostatic discharge Test as per IEC 61000-4-2:2008- Radiated Test as per IEC 61000-4-3-2010- Immunity to fast Transients Test as per IEC 61000-4-42012- RF field induced conducted disturbance Test as per IEC 61000-4-6:2013- Power frequency IEC 61000-4-8- Dry heat IEC 60068-2-30 (per cycle) and Damp Heat IEC 60068-2-30 (Per cycle)- Dielectric strength cl.6.8 of IEC 61010-1- Impulse cl.10.5.3. of IEC 60255-27 up to 8KVThe controller platform shall have standard BMS application programs that are modifiable to support both the traditional and specialized "sequence of operations". The BMS system shall be able to interface, control, monitor, automate the following equipments (a) 4 Nos. UPS of 30KVA - Control and Monitor
(b) 4 Nos. of Gas Based Supression System Panels - Monitor status and major parameters
(c) S&F Fire Alarm System with approx. 120 multisensor type detectors - Monitor only the fire alarm status
S&F BMS server station having computer processor 2.6Ghz along with the enclosure. The processor must be Processor- 7th gen intel Core TM i5 processor (2.6GHz) and 16GB DDR4 RAM 2400MHz or higher with two hard drives - Solid State Drive 512GB + 2TB Hard Drive. Along with Graphic Card- NVDIA G Force 920 MX with 2 TB GDDR5 graphics memory and screen monitor of 27 inches for the SCADA work station system. complete all as specified and directed. Must be accompanied by all peripherals such as mouse, keyboard, firewall, etc. with dedicated UPS supply having 30 minutes of backup
Supplying, drawing and commissioning of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. Including conduit and all accessories to mount/ fix the cable.complete all as specified and directed
Arboriculture Preparing compost pits of size 0.60x0.60x0.60 by excavation in ordinary soil carrying out antitermite treatment, planting trees & refilling of the pit with compost (manure, sand & sweet earth mixed in ratio (1:1:4) breaking moulds, ramming and flooding with water filling with more compost if necessary and fine dressing including removal of rubbish unserviceable materials & surplus soil to a distance n.exc 100 m. ATT shall be in form of 200 gms neem cake mixed with every cum of compost followed by Dursban or equivalent applied at 2 ml per litre in the first watering of 20 litres per pit, complete all as specified. Note :- (i) The rate for excavation and getting out of soil shall be deemed to be included in the unit rate of this item. (ii) The rate for mixing only earth, manure and sand is deemed to be included in the unit rate of this item supply of sweet earth, manure and sand shall be paid under respective item of this schedule.
Supply and planting following trees/Shrubs/palm in location where shown on drawing and described in schedule 'A' and specifications/directed by Engr-in-Charge, girth 80mm to 100mm minimum (measured at 150mm top of roots) and complete provided necessary pots whereas required as per plants and height as shown under. (a) Bottle palm `4' height
(b) Cycus palm 4' height
(c) Kochnar 4' height
(d) Champa 4' height
(e) Jacarnda mimo safelia 4' height
(f) Deloniox Regia (Gulmohar) 4' height
(g) Cassia fistala (Amaltas) 4' height
(h) Chinese Palm 4' height
(j) Ficus Panda
(k) Galphimia Glauca
(l) Plumbego
(m) Ficus Rajnold
(n) Bauhinia Alba
(o) Bougenvillia varigelta 4' height
CHEMICAL EARTHING M&L earthing pit with copper earth plat of size 3ft X 2ft X 5mm thick buried directly in gournd vertically to a depth not less than 4M below normal ground level , connected to & including 50 X 5 mm copper strip by means of nuts, boltsm check nuts and washers made of copper and connected to test point including brazing and excvation and earth work in any type of soil , charcoal 250 KG , Crystal salt 200 KG, magnesium sulphate of 100 KG and vegetable soil all around the plate 35 CM depth bottom to top of the plate full width of pin including PCC 1:3:6 type C1 in chamber of internal size 300 X 300 X 300 mm with wall thick ness of 120mm and 700 X 700 X 150mm bed concrete , precast PCC salb 50mm thick in cement concrete ( 1:2:4) type B1, reinforced with welded steel wire fabric or XPM Jali( weight not less than 4.00 Kg/sqm) with cast iron frame, funnel, with wire mesh, 25mm bore medium grade GI waterin pipe, lugs, 80mm bore medium grade GI protection pipe , test point etc complete all as specified and directed.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 50x6 mm Copper Strip complete all as specified & directed
M&L for 150mm (internal dia) dwcpe (double wall carrugated pipes) as per IS 16098 (Part-2): 2013 laid in trenches, jointed and tested complete all as specified.
M&L Antistatic false flooring (raised access floor) system (as specified in PS clause No 12.19.1 to 12.19.4 on Srl Page No 200R) complete all as specified.
M&L fully glazed main entrance door with 12mm thick toughened glass , double leaf and fixed glazing in rest opening area at entrance , with motion sensor system incl necessary stain less steel fittings. door lock etc complete all specified and directed.
M &L Fire Rated Fixed Partition glazing 120 minutes firee rated tested ,Integrity and radiation control (EW 120)- fully glazed non load bearing fixed partition system known as SGG Firesafe 120. The glass 8mm thick toughened should be contraflam Door lite IGU 120 min fire rated and partially insulated (EW 120). Non wired touhened interlayered glass complaint to class 2 (B) 2 category of impacty resistance as per EN 12600. The glass should be manufatured in UL & TUV audited facility and including UL-EU certification. The glass is tested as per En 1364-1 in efectis, Netherland or any other international reputed laboratory as approved by GE. The maximum glazing size shall not be more than 1000mm x 2000 mm (w x h) or 2 Sqms in total area or can very as per the testing certification. The test report will be considered valid only if it contains the stamp and signature of the authorized signatory from the manufacturer.
S&F hollow metal fire door as per IS 3614 PART-I & PART-II for stability and integrity pressed galvanised steel conforming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI/IFTS/VFRC for maximum of 2 hrs rating tested. Individual test certificate also be available for glass used as vision panel of size 724 x 958 of SGGC contraflame door lite 11mm clear 120min fire rated and partially insulated (EW-120). Non wired toughened glass of size 724 x 958 mm having a sound reduction of >37DB, LT of 86% and complaint to class 2B2 category of impact resistance as per En-12600. The glass should be manyfactured in UL &TUV audited facility and including UL-EU certification conforming the required fire rating/panel being a part of the fire door assembly doors should be finished in thermosetting powder coating desalted RAL sheds. Manufacturer test certificate shall cover door both single & double leaf doors and hardware’s. Door frame shall be double rebate profile of minimum size 154 x 77mm made out of 1.6mm (16 Gauge) minimum thick galvanised steel sheet NDRF 154 x 77mm frame shall be but jointed and field assembled with self bolted. The frames should be finished with thermosetting powder coating in desired RAL shade. ALl provision be mortised. Drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Each door shall be provided with followings:- (i) SS ball bearing hinges of size 100 x 75 x 3mm with SS Screwes (04 Nos per panel) (ii) Mortise dead lock. (01 Nos per panel) (iii) SSD type pull handle of size 300mm.(02 Nos per panel) (iv) Door closer.(01 Nos per panel) (v) Stainless steel concealed flush bolt 600mm(01 Nos per panel) (vi) SS flush pull handle.(01 Nos per panel) (vii) Shuft lock with allen key.(01 Nos per panel)
M&L for two coat fire retardent paint FR-880 and Make VIPER FRS-881of non combustible surface so as to achieve class-1 surface spread of flame as per IS:12777 and BS: 476 part 6 & 7. The surface is primed with two base coat of Fireguard Primer FR-880 and finished with Fire Retardant paint fire shield FRS-881 in desired shade @ 3.5 Sqm/litre as per the direction of Engineer-in-Charge. End-to-end coating of the FR paint shall be done. Complete all as specified and directed.
Description of Work / Item(s)
Amount
Total amount of Revised Sch 'A' Section I (Building work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of REVISED Sch 'A' Section II (Internal Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of REVISED Sch 'A' Section III (Internal Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Total amount of Sch 'A' Section IV (Area Drainage) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IV)
Total amount of REVISED Sch 'A' Section V (Sewage Disposal) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section V)
Total amount of Sch 'A' Section VI (Road Work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VI)
Total amount of Sch 'A' Section VII (Lightening Protection) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VII)
Total amount of Sch 'A' Section VIII (External Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VIII)
Total amount of Sch 'A' Section IX (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IX)
Total amount of Sch 'A' Section X (Excavation, Earth work & Site Clearance) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section X)
M/s Arihant Builders
Siya constructions
AMIT ASSOCIATES
M/S ANIL KUMAR
GRID ENGINEERS
Global Enterprises
M/s Arihant Builders
Siya constructions
AMIT ASSOCIATES
GRID ENGINEERS
Bidder Name
AMIT ASSOCIATES
M/S ANIL KUMAR
Global Enterprises
Siya constructions
M/s Arihant Builders
GRID ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .