| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹31.7 L+₹1.6 L (5.23%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹33.2 L+₹3.1 L (10.2%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹33.8 L+₹3.7 L (12.3%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | L5₹34.5 L+₹4.4 L (14.5%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
19 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) KUNJALI
DR HOMI BHABHA ROAD, NAVY NAGAR, COLABA, MUMBAI - 400 005
8395 REPAIR REPLACEMENT OF HIGH BAY LIGHTS AND FLAME PROOF LIGHTS INCLUDING CONNECTED WORKS AS PER AMWP OF NAVAL DOCKYARD UNDER GE NW KUNJALI
2021_MES_453346_1
8395/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹99,000
Yes
30 Jul 2021
21 Jun 2021
21 Jul 2021
28 Jun 2021
19 Jul 2021
5 Jul 2021
21 Jun 2021 - 28 Jun 2021
60 days
Amount
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan / sockets/ power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces as directed.
M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 1.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete for One light/fan/bell point controlled by one 5A switch complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
One light point controlled by one 5A switch
One fan point controlled by one 5A switch
One Bell point controlled by one bell push
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L in repair in repair point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including MS surface conduit with accessories fixed on wall/ceiling/truss etc with metallic ISI marked terminal boxes surfacing on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth as earth dolly for( Make: schneider elect/legrand mosaic/anchor ave) complete for One light/fan/bell point controlled by one 5A switch complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
One light point controlled by one 5A switch
One fan point controlled by one 5A switch
One 5 pin 15A flush type switch socket point on independent board
M&L for point wiring (Work station for computer) complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etc fixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 4.0 sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete necessary electric connection for each workstation point comprising of 03 Nos 5A sockets with 1.5 sqmm and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/ Plaza
S & F in replacement of Bell push, 5/6 Amps, 240 volts SP complete all as directed.
S & F modular switch 1 way 6A,1 module all as specified and directed. Make: Anchor/Roma/Legrand.
S & F modular switch 1 way 16A,1 module all as specified and directed. Make: Anchor/Roma/Legrand
S & F modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed. Make: Anchor/Roma/Legrand
S & F modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed. Make: Anchor/Roma/Legrand
S&F for modular fan step regulator, 120W - 2 modular all as specified and directed. Make: Anchor/Roma plus/Legrand
S & F in replacement of bell, DINGDONG type, 6 Amps, 240 volts, SP complete all as directed.
S &F in repair flame proof rotary switch 16A with termination box LM6 single pole, 250V all as specified and directed. Make-Sudhir or equivalent in Crompton/Ajmera
S & F lamp holder PVC/polycarbonate insulated body type complete all as directed. Make : C&S cat No ACBHA006/Anchor/Roma
S & F in repirs LED light fitting 20W, 230 V, 4 feet surface monted, indoor decorative aluminium extruded T- 5 LED batten, integrated type etc., complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round block-02 Nos including connecting up with twin core twisted flexible copper conductor cable with suitable size and all as directed. Make- C & S cat part No. LTTB4F20WLED/W (Nakshatra series) or equivalent cat part in Crompton/ Bajaj /Philips
S &F 150 Watt LED, Highbay/Mediumbay LED IP65, PDC aluminium housing with mounting bracket / eyebolt, SMD LED array with intetrated lens polycarbonate cover, IP66 Protection suitable for Street light fittingand general purpose lighting complete with all acessories and fixing arrangement al as specified and directed. Make- C & S CAT Part No.-LTEHB150WHPLED/LS/WOR (CORVUS-E SERIES) or equivalent cat part in Crompton/ Bajaj / Philips
S &F 200 Watt LED, Highbay/Mediumbay LED IP65, PDC aluminium housing with mounting bracket / eyebolt, SMD LED array with intetrated lens polycarbonate cover, IP66 Protection suitable for highbay fitting and general purpose lighting complete with all acessories and fixing arrangement al as specified and directed. Make- C & S CAT Part No.-LTEHB200WHPLED/LS/WOR (CORVUS-E SERIES) or equivalent cat part in Crompton/ Bajaj / Philips
S &F 200 Watt LED, PDC aluminium housing with sealed toughened glass cover, SMD LED with secondary lens, IP66 Protection, Flood light fitting , suitable for high mast application, highlighting architectural facade and general purpose lighting complete with all acessories and fixing arrangement al as specified and directed. Make- C & S CAT Part No.-LTEF200WHPLED (ORION-3.0 SERIES) or equivalent cat part in Crompton/ Bajaj / Philips
S &F 60 Watt LED, PDC aluminium housing with sealed toughened glass cover, SMD LED with secondary lens, IP66 Protection suitable for Street light fittingand general purpose lighting complete with all acessories and fixing arrangement all as specified and directed. Make- C & S CAT Part No.-LTESSI60WLED (INDUS-i SERIES) or equivalent cat part in Crompton/ Bajaj / Philips
S &F 90 Watt LED, PDC aluminium housing with sealed toughened glass cover, SMD LED with secondary lens, IP66 Protection suitable for Street light fittingand general purpose lighting complete with all acessories and fixing arrangement all as specified and directed. Make- C & S CAT Part No.-LTESSI90WLED (INDUS-i SERIES) or equivalent cat part in Crompton/ Bajaj / Philips
S &F 40 WATT LED industrial light fitting, IP65 protection, integrated LED Wellglass aesthetically designed & it comprises of Pressure Die Cast canopy, Driver housing and of heat resistant glass / opal PC / clear PC bowl to provide better lighting complete with all acessories and fixing arrangement all as specified and directed. Make- Crompton CAT PART No LWVLT-40-CDL (Glaze) or equivalent in Bajaj, wipro, Havell
S &F 18 WATT LED flame proof light fitting IP65 luminaire omplete with all acessories and fixing arrangement all as specified and directed. Make-Sudhir or equivalent in Crompton/Ajmera
S &F 2X20 WATT LEDflame proof light fitting IP65 luminaire omplete with all acessories and fixing arrangement all as specified and directed. Make-Crompton CAT PART No EXTN2LT8-16/20 or equivalent in Bajaj/ Ajmera / Sudhir
Supply and fixing in repair Ultra slim edge lit type recess mounting LED 2X2 Luminaire 36 watt and extruded aluminium housing with anti-glare diffuser provides high quality ecomonic energy saving lighting LED Luminaire suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make: Crompton cat No LCPL-36-CDL(2X2) / C&S cat No LTCRSLM36WATT 2X2 or equivalent Cat part in Bajaj / Philips
S&F in repair of Recessed full / Surface type LED 2X2 Luminaire 36 watt and CRCA powder coating housing with anti-glare diffuser, New deep back lit type surface mounting LED Luminaire provides high quality ecomonic energy saving lighting suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make: Crompton cat No LCTLSN-36-CDL(2X2) / C&S cat No LTCSP36WLED2X2 or equivalent Cat part in Surya / Philips
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 42 or equivalent Cat part in Siemens/C&S
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 41 or equivalent Cat part in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 40 or equivalent Cat part in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 4 way, 440 volts with 100A Copper Busbar rating 440 Amps, for each phase, 2 Neutral bar, 2 Earth bar, dust and vermin proof with provision for DPX³ 160 MCCB as incomer DP MCB/Isolator/RCCB/RCBO as sub incomers and SP MCB's as outgoing etc. complete all as directed. Make - Legrand cat No 5077 50 or equivalent in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 12 way, 440 volts with 100A Copper Busbar rating 440 Amps, for each phase, 2 Neutral bar, 2 Earth bar, dust and vermin proof with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB's as outgoing etc complete all as directed. Make - Legrand cat No 5077 53 or equivalent in Siemens/GE NOTE FOR ITEM No. 25 to 29 : MCB DBs shall be concealed in wall where ever posible including cost of removing old wooden box making good the surface to match with surrounding deemed to be included in quoted rates
S & F MCCB, 415 volts, four pole of cap 100 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4200 55 or equivalent in siemens/GE / C&S
S & F in replacement 20 Amps Single pole and neutral enclosure with a Two Pin and earth plug and socket complete with one single pole MCB and making connections complete all as directed. Make -Legrand Cat Part No. 5078 14 or equivalent in Siemens /GE/ C&S
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make: Legrand cat No 4085 87-95 or equivalent Cat part in Seimens/C&S.
S & F in replacement of MCB .5 to 4 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make: Legrand cat No 4085 80-85 or equivalent Cat part in Seimens/C&S.
S&F MCB SPN 40-63Amps, 10KA 'C' Curve 240V complete all as specified and directed. Make: Legrand cat No 4086 18-20 or equivalent Cat part in Seimens/C&S.
S & F MCCB, 415 volts, four pole of cap 160 Amps, 16/18 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4200 17 or equivalent in siemens/GE / C&S
S & F MCCB, 415 volts, 3 pole of cap 125 Amps, 16/18 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4200 06 or equivalent in siemens/GE / C&S
S & F MCCB, 415 volts, four pole of cap 200 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 4202 18 or equivalent in siemens/GE / C&S
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core laid in duct / along pole/wall tc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sq mm 4 core laid in duct / along pole/wall etc including making connection complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
M&L for sub-main wiring with 2 runs of 4.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade non metallic PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Gloster / Plaza
M&L for sub-main wiring with 2 runs of 6.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade non metallic PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Gloster / Plaza
M&L for sub-main wiring with 4 runs of 10.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade non metallic PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including 2 run of 6.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza
Supply of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron (average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied alongwith weatherproof chamber. Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
ASHOK ENTERPRISES
Shree Ayyappa Engineering
DHARMESH ENTERPRISES
ELECTRO ASSOCIATES
Rohit Enterprises
M/s S.D Construction Co
Genius Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .