Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
16 Sept 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PR & CC
This tender is floated for supply, installation and commissioning of Electric Vehicle Charging System at
22000390-HD-10157
22000390-HD-10157
Open Tender
Two Bid
Unknown (Unspecified Location)
₹0
₹10 L
16 Sept 2022
26 Aug 2022
16 Sept 2022
16 Sept 2022
27 Aug 2022 - 6 Sept 2022
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | VEHICLE CHARGER | VEHICLE CHARGER — PART NAME:ELECTRICAL VEHICLE CHARGER; PART RATING:MINIMUM 3 KW; ADDITIONAL INFORMATION:NUMBER OF PHASE:1; AC INPUT:VOLTAGE RATING:1-PHASE, 200~240VAC (±15%), MAXIMUM INPUT CURRENT:16A, INPUT FREQUENCY:50 HZ ± 1.5HZ, USER AUTHENTICATION:RFID , QR-CODE SCAN, OCPP BASED MOBILE APP INTERFACE. BACKUP POWER:INPUT SUPPLY FAILURE BACKUP:BATTERY BACKUP FOR MINIMUM 1 HOUR FOR THE CONTROL SYSTEM AND BILLING UNIT. AC OUTPUT:NUMBER OF OUTPUT PORTS:1 NUMBER, OUTPUT CONNECTOR: IEC 60309, OUTPUT CURRENT:15 AMP, OUTPUT POWER:230VAC, 50 HZ, 3.3 KW. AC INPUT PROTECTION:AC VOLTAGE PROTECTION:AC OVER-VOLTAGE, AC UNDER-VOLTAGE, AC CURRENT PROTECTION:AC OVER CURRENT/SHORT CIRCUIT, AC SAFETY PROTECTIONS:RESIDUAL CURRENT/GROUND FAULT, EARTH PRESENCE/CONNECTION MONITORING, POLARITY REVERSE PROTECTION, SURGE PROTECTION 4 KV DM, OVER TEMPERATURE. ENERGY METERING:INDEPENDANT AC ENERGY METER FOR EACH OUTPUT:CLASS 1.0 ENERGY METER FOR EACH OUTPUT, OPERATING TEMPERATURE:-30 TO 55 DEG C. HUMIDITY:ENCLOSURE PROTECTION: <95% RELATIVE HUMIDITY, NON-CONDENSING, ENCLOSURE PROTECTION:IP55 OR BETTER, COOLING METHOD:NATURAL/FORCED:NATURAL/FAN COOLING, APPLICATION:TO CHARGE:E-AUTO, E-RIKSHAW, E-SCOOTERS, HAVING 1 OUTPUT | - | Each |
| 2 | INSTLN & COMMNG OF EV | INSTLN & COMMNG OF EV — INSTALLATION AND COMMISSIONING 3 KW EV CHARGER: INSTALLATION AND COMMISSIONING 1 PHASE MINIMUM 3 KW ELECTRIC VEHICLE CHARGER HAVING 1 OUTPUT. INSTALLATION AND COMMISSIONING 3 KW EV CHARGER: INSTALLATION AND COMMISSIONING 1PHASE MINIMUM 3 KW ELECTRIC VEHICLE CHARGER HAVING 1 OUTPUT. THE SCOPE OF INSTALLATION AND COMMISSIONING INCLUDES INTEGRATION WITH THE HPCL SOFTWARE AND PROVIDING 4G SIM FOR CONNECTIVITY, DEMONSTRATION AND TRAINING TO DEALER MEN/HPCL OFFICERS. | - | Each |
| 3 | VEHICLE CHARGER | VEHICLE CHARGER — PART NAME:ELECTRICAL VEHICLE CHARGER; PART RATING:MINIMUM 7 KW; ADDITIONAL INFORMATION:NUMBER OF PHASE:1; AC INPUT:VOLTAGE RATING:1-PHASE, 200~240VAC (±15%), MAXIMUM INPUT CURRENT:32 A, INPUT FREQUENCY:50 HZ ± 1.5HZ, USER AUTHENTICATION:RFID, QR-CODE SCAN, OCPP BASED MOBILE APP INTERFACE. BACKUP POWER:INPUT SUPPLY FAILURE BACKUP:BATTERY BACKUP FOR MINIMUM 1 HOUR FOR THE CONTROL SYSTEM AND BILLING UNIT. AC OUTPUT:NUMBER OF OUTPUT PORTS:1 NUMBER, OUTPUT CONNECTOR:IEC 62196 TYPE-2 PLUG CABLE LENGTH-5 M MIN, OUTPUT CURRENT:32 AMP, OUTPUT POWER:230 VAC, 50 HZ, 7.2 KW. AC INPUT PROTECTION:AC VOLTAGE PROTECTION:AC OVER- VOLTAGE, AC UNDER-VOLTAGE, AC CURRENT PROTECTION:AC OVER CURRENT/SHORT CIRCUIT, AC SAFETY PROTECTIONS:RESIDUAL CURRENT/GROUND FAULT, EARTH PRESENCE/CONNECTION MONITORING, POLARITY REVERSE PROTECTION, SURGE PROTECTION 4 KV DM, OVER TEMPERATURE. ENERGY METERING:INDEPENDENT AC ENERGY METER FOR EACH OUTPUT:CLASS 1.0 ENERGY METER FOR EACH OUTPUT, OPERATING TEMPERATURE:-30 TO 55 DEG C. HUMIDITY:ENCLOSURE PROTECTION: <95% RELATIVE HUMIDITY, NON-CONDENSING, ENCLOSURE PROTECTION:IP55 OR BETTER, COOLING METHOD:NATURAL/FORCED:NATURAL/FAN COOLING, APPLICATION:TO CHARGE:LIGHT MOTOR VEHICLES, HAVING 1 OUTPUT | - | Each |
| 4 | INSTLN & COMMNG OF EV | INSTLN & COMMNG OF EV — INSTALLATION AND COMMISSIONING 7 KW EV CHARGER: INSTALLATION AND COMMISSIONING 1 PHASE MINIMUM 7 KW ELECTRIC VEHICLE CHARGER HAVING 1 OUTPUT. INSTALLATION AND COMMISSIONING 7 KW EV CHARGER: INSTALLATION AND COMMISSIONING 1PHASE MINIMUM 7 KW ELECTRIC VEHICLE CHARGER HAVING 1 OUTPUT. THE SCOPE OF INSTALLATION AND COMMISSIONING INCLUDES INTEGRATION WITH THE HPCL SOFTWARE AND PROVIDING 4G SIM FOR CONNECTIVITY, DEMONSTRATION AND TRAINING TO DEALER MEN/HPCL OFFICERS. | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
22000390-HD-10157.pdf
TENDER_DOCUMENT • 16.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .