Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC KASHYABPUR MAHISHREKHA P S ULUBERIA HOWRAH 711303 | HOWRAH | HOWRAH | WEST BENGAL | 711303 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.3 L+₹6,931.75 (0.38%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L2 | Rejected-Finance Rejected | |
| 3 | L3₹18.3 L+₹8,223.66 (0.45%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹20.9 L+₹2.6 L (14.2%)Rejected-Finance 86 PURUSOTTAM ROY STREET KOLKATA 700007 | KOLKATA | WEST BENGAL | 700007 | L4 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | WEST BENGAL ENGINEERING CO. L2 | DAS ENTERPRISE L3 | OM CORPORATION L4 | APEX ENGINEERING & PROJECT CO L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | INTAKE P/H
Operation and guarding of 12nos (8W+4S) L/L Submersible pumping machinery (River Bed) including others pumps, MCC panels individual motor control starter panels, 63KVA AVR electrical gadgets, All valves, etc and internal & external illumination complete with all other electrical accessories and ancilliaries by engaiging 3(three) nos operating personnel for round the clock supply of water as per direction of E.I.C(Including Bonus, EPF ESI) | 366 | Days | 1,758 ₹6,43,428 | 1,760 ₹6,44,160 | 1,503 ₹5,50,098 Lowest | 1,755 ₹6,42,330 |
| 2.00 | HIGH LIFT P/H
Operation, guarding of 3 Nos. (2W+1S) each of 45 KW Centrifugal pumping machinery (Booshting pump), 2nos- Dewatering pumps, H.T & L.T. PDB panel cum MCC panels (Clear water pump) individual Soft starter panels, electrical gadgets, actator operated butterfly valves, flow meters, level indicators etc an inside the booshting pumping station and internal and external illumination complete with all other electrical accessories and ancilliaries and Operation and guarding of 11/0.433. KV outdoor Sub-Station (200 KVA X 2nos ) including lighting transformer , Sub-Station equipment’s ,10 KVA D.G Set and other allied accessories including operation of HV Panel Boards, Control Panel Board, Capacitor Banks, 110 Volt DC trip circuit, battery charger etc. also operation of LV panel board for lighting arrangement by engaging 3(Three) nos operating personnel round the clock as per direction of E.I.C (Including Bonus, EPF ESI) | 366 | Days | 1,758 ₹6,43,428 | 1,760 ₹6,44,160 | 1,503 ₹5,50,098 Lowest | 1,755 ₹6,42,330 |
| 3.00 | Routine and periodical maintenance of Clear water pumps, motors, manual operated valves , tightening of nut bolt of sluice valve, air valve, dismantling joint ,replacement of gland packing for pumps and sluice valves with proper lubrication of motor bearings including replacements of indicating lamp with holder etc. Cleaning of Clear water Pump House, PDB room H.T & L.T Switch room, in regular manner by providing all necessary material viz. cotton duster, broom sticks, detergent soap, etc. as per direction of E.I.C. | 366 | Days | 70 ₹25,620 | 69 ₹25,254 | 470 ₹1,72,020 | 68 ₹24,888 Lowest |
| 4.00 | Supervision charges for electrical installation by licensed electrician having requisite parts as per IE rules, 1956 with latest amendments and overhead expenditures for the above period | 12 | month | 8,700 ₹1,04,400 | 8,770 ₹1,05,240 | 12,000 ₹1,44,000 | 8,678 ₹1,04,136 Lowest |
| 5.00 | Servicing, testing and calibration of different relays, breakers and cleaning of carbon shoots from bus bar, breaker, meter CT & PT chamber etc. for smooth operation of the 11/0.433. KV outdoor Sub-Station (200 KVA X 2nos ) Sub-Station and Pump meters etc by any testing Agency approved by WBSEDCL or Directorate of Electricity Board as per scope of work.
(Twice in a year)
N.B- All test report and calibration certificate are to be submitted | 2 | Item | 26,150 ₹52,300 | 25,720 ₹51,440 | 30,000 ₹60,000 | 25,500 ₹51,000 Lowest |
| 6.00 | Supply of HSD and lubricants at site including all carriage and storage for running (10 KVA) diesel engine as an when requred as per direction and as per log book | 180 | Hrs | 185 ₹33,300 | 183 ₹32,940 | 500 ₹90,000 | 181.71 ₹32,707.8 Lowest |
| 7.00 | Cleaning of Pump House, Substation , and its surroundings by engaging sweeper in regular manner by providing all necessary material viz. cotton duster, broom sticks, batteries, carbolic acid, detergent soap, gloves, apron including all tools tackles, etc. required as per direction of E.I.C. | 366 | Days | 98 ₹35,868 | 99 ₹36,234 | 501 ₹1,83,366 | 96 ₹35,136 Lowest |
| 112.00 | Add: 18% GST | 1 | Item | 2,76,901.92 ₹2,76,901.92 | 2,77,097.04 ₹2,77,097.04 | 3,14,924.76 ₹3,14,924.76 | 2,75,855 ₹2,75,855 Lowest |
| 113.00 | Add: 1% Cess | 1 | Item | 18,152.46 ₹18,152.46 | 18,165.25 ₹18,165.25 | 20,645.07 ₹20,645.07 | 18,083.83 ₹18,083.83 Lowest |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
19 Jan 2024, 6:00 pmClosed
Executive Engineer, BMD, PHE, Dte
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Operation, and Guarding of pumping machineries and Sub-Station equipments at intake and H/L pumping station under Dahala Sub Surface Water Based Piped Water Supply Scheme Block Ranibandh (BRGF Phase I) under Bankura Mechanical Division, PHED
2023_PHED_629675_5
WBPHED/EE/BMD/NIeT- 25 OF 2023-2024
Open Tender
MECHANICAL
Item Rate
366 days
Bankura
Please refer Tender documents.
6 documents required · 6 mandatory
₹45,000
Yes
5 Nov 2025
2 Jan 2024
22 Jan 2024
2 Jan 2024
19 Jan 2024
2 Jan 2024
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .