Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.1 Cr+₹3.7 L (3.60%)Rejected-Finance 1 3 183 40 46 PLOT NO 36 VAIKUNTHA SAI NAGAR NEW BAKARAM GANDHI NAGAR HYDERABAD TELANGANA 500080 | HYDERABAD | TELANGANA | 500080 | ₹1.1 Cr+₹3.7 L (3.60%) | L2 | Rejected-Finance reject |
| 3 | L3₹1.1 Cr+₹11.6 L (11.5%)Rejected-Finance | ₹1.1 Cr+₹11.6 L (11.5%) | L3 | Rejected-Finance reject |
| 4 | L4₹1.2 Cr+₹18.6 L (18.3%)Rejected-Finance | ₹1.2 Cr+₹18.6 L (18.3%) | L4 | Rejected-Finance Reject |
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
27 Mar 2023, 3:00 pmClosed
LT COL VIKAS BADHANI
PB NO 1569 AKBAR ROAD SECUNDERBAD 500003
OPERATION AND MAINTENANCE OF ENM INSTALLATIONS DG SETS, EOT CRANES AIR CONDITIONERS WATER SUPPLY WATER TRETMENT PLANTS SEWAGE TREATMENT PLANTS FIRE ALARM,FIRE FIGHTING SYSTEMS WATER COOLERS WITH WATER PURIFIERS AREA AND PERIMETER LIGHT
2023_DRDO_744082_1
83631/ONM/C DURGA/CON
Limited
Support/Maintenance Service
Item Rate
330 days
ATR CHITRADURGA
AS PER NIT
2 documents required · 2 mandatory
₹1,000
Yes
CCERNDSOUTH SECUNDERABAD
₹2.3 L
Yes
4 May 2023
6 Mar 2023
28 Mar 2023
6 Mar 2023
27 Mar 2023
17 Mar 2023
7 Mar 2023 - 16 Mar 2023
Amount
Operation and Maintenance of Internal & External electrification, DG sets, EOT Cranes, Air-Conditioners, water supply System, Fire Fighting, Fire Alarm, Water Treatment Plant, Sewage Treatment Plant Compressed air line and Area, Perimeter Lighting as per the tender conditions, scope of work and schedule of manpower on all days in a week.
Routine Maintenance & Over Time for Skilled personal .
Routine Maintenance & Over Time for un Skilled personal .
Carrying B-Check for following capacity Diesel Engines for Generators and Fire fighting Pumps by the OEM/Authorized Service agency periodically including all required spares/filters/engine oil etc. as per the instructions of Engineer-In-Charge
a) 750 KVA, 11 KV DG sets (Cummins Model: KTA-38-G10)
b) 200 KVA, 440V DG set (Cummins Model: QSB-67-G12)
c) 62.5 KVA, 415V DG set(Cummins Model: 4BTAA3.3-G11)
d) 30 KVA, 415V DG set(Cummins Model: X2.7TAA-G2)
e) 85 bhp Diesel Engine driven Fire Pump (Kirloskar 4R1040T)
Carrying out annual preventive maintenance like oil filteration, insulation check etc for following capacity transformers/AVR/ Regulator by OEM/authorised agency including cost of standard replaceables/ consumbles etc. but excluding topping up of transformer oil
a) 250 KVA tranformer(300 Ltr)
b) 250 KVA tranformer(340 Ltr)
c) AVR HT Unit(600 Ltr)
d) AVR Regulator Unit(300 Ltr)
e) 750 KVA Transformer(940 Ltr) including OLTC(210 litres)
f) 630 KVA Transformer(1050 Ltr) including OLTC( 210 litres)
g) 160 KVA Transformer(230 Ltr)
h) 100 KVA Transformer(275 Ltr)
i) 63 KVA Transformer(245 Ltr)
Servicing of 11KV SFU by authorized agency of OEM/agency having license issued by state/central electricity authorities etc.
Servicing of 11KV VCB alongwith Carrying out relay calibration by authorized agency of OEM/agency having license issued by state/central electricity authorities etc.
a) 800A VCBs (Siemens)
b) 800A VCBs (Crompton)
c) 440V ACBs (L&T)
Conducting Load Test by governement authorised agency for 5 Ton EOT Crane
Inspection by OEM for 1 Nos of 5 Ton capacity Crane which-includes two visits (i.e once in 5 months) one Engineer & one techinican duly carring over inspection of both the cranes i.e all electrical & mechanical items, running the crane and testing the components, preparation of inspection reports and recommendation of necessary spares/repair works. The cost should include all expenses including travelling, local conveyance, lodging and boarding charges.
Inspection by OEM as and when required during the brake down of 1 No 5 Ton capacity Crane which-includes one Engineer duly carring over inspection of the crane i.e all electrical & mechanical items, running the crane and testing the components, preparation of inspection report. The cost should include all expenses including travelling, local conveyance, lodging and boarding charges.
a) Supply of gear oil for 5T cap crane
b) Supply of brake oil for 5T cap crane
c) Supply of grease
Annual Maintenace Contract for
Fire Alaram System
Periodical Servicing by OEM of Fire Alarm System once in 3 (three) months by Engineer and technician for all the Buildings as per invaentory. The cost should include all expenses including travelling, local conveyance, lodging and boarding charges of technicians
Emergency visit by Engineer with technician for attending emergency failure. The cost should include all expenses including travelling, local conveyance, lodging and boarding charges of technicians. Cost for additional days would be needed for completing the work is extra as belows
Additional days on emergency visit
Identification of FO cable inclduing hiring of machinery for cable fault locator, JCP for earth removal and replacement
Identification of fault in HT/LT Cable of various sizes by hiring machinery for Cable Fault (Each Fault)
Supply of concentrated Sodium Hypochlorite liquid (as per Indian Standards) for treatment of drinking water including transportation and unloading at pump houses as and when required.
Supply of Transformer oil (mineral) as and when required as per the instruction of Engineer-in-charge
Supply and filling of Refrigerant gas of for all types of air-conditionerrs as per requirement and instructions of Engineer-in-charge
Air- conditioners Spare Parts:
AC Swing Blade Motor, Blue Star (Model: CNHW18CAFI/Model: CNHW24CAFI)
AC Swing Blade Motor, Voltas(Model: 183VEY/Model: 243VEY)
AC Swing Blade Motor, Blue Star (Model: SE365GI)
AC Indoor Blower Fan Motor, Blue Star(Model: CNHW18CAFI/Model: CNHW24CAFI)
AC Indoor Blower Fan Motor, Voltas(Model: 183VEY/Model: 243VEY)
AC Indoor Blower Fan Motor, Blue Star (Model: SE365GI)
AC Indoor Blower Fan Motor, Blue Star(Model: DSA661R1)
AC Indoor Blower Fan Motor, Blue Star(Model: DSA1021R1)
AC Indoor Blower Fan Motor, Blue Star(Model: DSA1321R1)
Indoor AC PCB Board, Blue Star(Model: CNHW18CAFI/Model: CNHW24CAFI)
Indoor AC PCB Board, Voltas(Model: 183VEY/Model: 243VEY)
Indoor AC PCB Board, Blue Star(Model: SE365GI)
Indoor Ductable AC PCB Board, Blue Star(Model: DSA661R1)
Indoor Ductable AC PCB Board, Blue Star(Model: DSA1021R1)
Indoor Ductable AC PCB Board, Blue Star(Model: DSA1321R1)
AC Remote(Model: 183VEY/Model: 243VEY)
AC Outdoor Fan Motor, Blue Star (Model: CNHW18CAFI/Model: CNHW24CAFI)
AC Outdoor Fan Motor, Voltas(Model: 183VEY/Model: 243VEY)
AC Outdoor Fan Motor, Blue Star (Model: SE365GI)
AC Outdoor Fan Motor, Blue Star (Model: DSA661R1)
AC Outdoor Fan Motor, Blue Star(Model: DSA1021R1)
AC Outdoor Fan Motor, Blue Star (Model: DSA1321R1)
AC Outdoor Fan Blades, Blue Star(Model: CNHW18CAFI/Model: CNHW24CAFI)
AC Outdoor Fan Blades, Voltas(Model: 183VEY/Model: 243VEY)
AC Outdoor Fan Blades, Blue Star(Model: SE365GI)
AC Outdoor Fan Blades, Blue Star (Model: DSA661R1)
AC Outdoor Fan Blades, Blue Star(Model: DSA1021R1)
AC Outdoor Fan Blades, Blue Star (Model: DSA1321R1)
Outdoor AC PCB Board, Blue Star(Model: CNHW18CAFI/Model: CNHW24CAFI)
Outdoor AC PCB Board, Voltas(Model: 183VEY/Model: 243VEY)
AC Coil sensor, Blue Star (Model: CNHW18CAFI/Model: CNHW24CAFI)
AC Coil sensor, Voltas(Model: 183VEY/Model: 243VEY)
AC Room Temerature sensor, Blue Star (Model: CNHW18CAFI/Model: CNHW24CAFI)
AC Room Temerature sensor, Voltas(Model: 183VEY/Model: 243VEY)
AC Room Temerature sensor, Blue Star(Model: DSA661R1/DSA1021R1/DSA1321R1)
Wired Remote, Blue Star(Model: DSA661R1/DSA1021R1/DSA1321R1)
Contactor 3P, AC-3, 18A
Contactor 3P, AC-3, 32A
Repairing of PCB for 1.5 TR Indoor Unit of Inverter AC(Blue Star Model: CNHW18CAFI)/Voltas Model: 183VEY/ Hitachi Model: RSN317HCEA
Repairing of PCB for 1.5 TR Outdoor Unit of Inverter AC(Blue Star Model: CNHW18CAFI)/Voltas Model: 183VEY/ Hitachi Model: RSN317HCEA
Repairing of PCB for 2 TR Indoor Unit of Inverter AC (Blue Star Model: CNHW24CAFI/Voltas Model: 243VEY/Voltas Model : EU243V SZS/ Hitachi Model: RMOS424HCEA
Repairing of PCB for 2 TR Outdoor Unit of Inverter AC (Blue Star Model: CNHW24CAFI/Voltas Model: 243VEY/Voltas Model : EU243V SZS/ Hitachi Model: RMOS424HCEA
Repairing of PCB for 3TR Indoor Unit of Blue Star AC(Model: SE365GI)
Repairing of PCB for 5.5 TR Indoor Unit of Blue Star Ductable AC(Model: DSA661R1)
Repairing of PCB for 8.5 TR Indoor Unit of Blue Star Ductable AC(Model: DSA121R1)
Repairing of PCB for 11 TR Indoor Unit of Blue Star Ductable AC(Model: DSA1321R1)
Rewinding of following capacity and type of motor
3-Ph, 415V, 1.5 HP monobloc pump set
3-Ph, 415V, 3.0 HP monobloc pump set
3-Ph, 415V, 5.0 HP monobloc pump set
1-Ph, 230V, 0.5 HP Openwell submersible water pump set
1-Ph, 230V, 0.5 HP submersible sludge pump set
1-Ph, 230V, 1.0 HP submersible sludge pump set
3-ph, 415V, 5.0 HP Submersible Borewell pump set
3-Ph, 415V, 7.5 HP Submersible Borewell pump set
Supply of e-cell electrode made up of Aluminum alloys of size 400mmx400mmx5mm thick x 10 Nos. plates for Electrolysis tank(e-cell) of Sewage Treatment Plant of capacity 30 KLD as required.
Supply of sand filter media of various different sizes
Supply of Activated carbon 450IV media
Supply of Activated carbon 900IV media
Supply of Resin, IEIL Na220
Supply of Distilled Water
Supply of rotameter(1000-10000LPH)
Supply of hand held type Digital PH meter(0-14PH)
Supply of hand held type TDS meter(0-9990PPM)
Supply of following mentioned spare as per the terms & conditions and specifications mentioned in the enquiry. All items shall be as per Indian Standard codes and Specifications followed for Electrical Systems.
Consumables
9/11W CFL 2 Pin
9/11W CFL Electronic Ballast 2 Pin
18W CFL 4 Pin
18W CFL Electronic Ballast 4 Pin
36W CFL 4 Pin
70W SV Lamp
150W SON-T SV Lamp Tubular
400W SON-T SV Lamp Elliptical
40W Halogen lamp for QWZ807(Philips)
40W Halogen lamp for QWZ812(Philips)
0.5W B-22 Night Light Bulb (White Colour)
150W Metal Halide lamp for SWF231 1XMHNTD-150W(Philips)
70W Metal Halide lamp for MPF92 1XMHNTD70W(Philips)
20 W LED Tube light fitting
18W, 4pin Holder
28W Fluoroscent T5 Tube lights
Electronic Ballast EBP 221/228 TL5
Electronic Ballast EBT 228 TL5
Electronic Ballast EBT 128 TL5
Electronic ballast EBT 236 TLD
Electronic ballast EBE 236 TLD
70W Copper Wound Ballast
150W Copper Wound Ballst Open Construction
Ignitor for SV lamp 70W/150W/250W/400W
LED Driver for Street Light Fixture(Philips) (Uin:240V, Pin:82W max, Iin:0.36A max, Vout:60-74V DC, Iout:950mA)
LED Driver for RC 380B LED-30-6500PSEODWH)
LED Driver for 40W Cromton Street Light Fixture(Model No:40-CDL-M)
2.25uF Capacitor for Fan
63A, 4P, C Curve MCB
Testing charges of drinking water
Testing charges of sewage water
Supply of Industrial salt
Supply of Alum
Rewinding of 60W ceiling fan
Rewinding of 60W Exhaust fan
Rewinding of 90W Exhaust fan
Supply of Silca Gel
150mm Dial Winding Temperature Indicator
150mm Dial Oil Temperature Indicator
Supply of Following RO Water Filters Spares:
Sediment filter (Kent: Spare part code:20011)
Sediment filter (Kent: Spare part code:20013)
Activated carbon filter(Kent: Spare part code:20012)
Activated carbon filter(Kent: Spare part code:20014)
RO Membrane(Kent: Spare part code:20531)
RO Membrane(Kent: Spare part code:20002)
FRT(Kent: Spare part code:20018)
Solenoid Valve(Kent: Spare part code:20028)
Booster Pump with pump Head (Kent: Spare part code:20006 & 20059)
SMPS(Kent: Spare part code:20016)
UF Memberane (Kent: Spare part code:20004)
Carbon Block Filter(Kent: Spare part code:20673)
Post Carbon Filter (Kent: Spare part code:20015)
Auto Flash PCB (Kent: Spare part code:20023)
TDS Control valve(Kent: Spare part code:20034)
UV lamp(Kent: Spare part code:20540)
UF Filter(Kent: Spare part code:20003)
Ballast(Choke)(Kent: Spare part code:20021)
Aquaguard RO Kit
Supply of following Electrical Items:
1/2 Module Front white plate with frame
3 Module Front white plate with frame
4 Module Front white plate with frame
Supply of Central Processing Unit for NFS2-640 Notifier Addressable Fire Alarm Panel with Integral Power supply card including CHS2-M2 Chassis (Model No. CPU2-640E)
Supply of Analogue addressable type multi sensor (smoke/Heat) photo electric detectors
Supply of Response indicators
Supply of Analogue addressable Control Module
Arrangement of 4 Wheel Drive Multi Utility with Maintenance Ladder along with Driver having nexperience/License in Hill Driving on Hours Basis per Maintenance of Street Light at Perimeter Road all along the compund wall.
Supply of 12V, 7AH Maintenance free battery with old battery replacement
Supply of 12V,150AH Lead Acid Battery with old battery replacement
Supply of following items:
36±5%uf, 440V Capacitor
25±5%, 440V Capacitor
16±5%uf, 440V Capacitor
10±5%uf, 440V Capacitor
8±5% uf, 440V Capacitor
3.5±5% uf, 440V Capacitor
43±5% uf, 250V Capacitor
2 KW, Geyser Element
Thermostat for 2 KW Geyser
32mm dia 10Kg/sq cm CPVC Pipe
32mm dia CPVC 90 ̊bends
32mm dia T bend CPVC
32 mm PVC Foot Valve
25 mm PVC Foot Valve
L&T MNX-12/MO12, 3P Contactor, AC-3, 12A
L&T MNX-18/MO18, 3P Contactor, AC-3, 18A
L&T MK1, 3P Contactor, 15A
3P, MPCB- 2.5-4A
3P, MPCB- 4-6.3A
1-Phase Transformer 220V/30V, 2.4KVA
Overcurrent Monitoring relay (Minilec OCS D1)
Single Phase Preventer, 415V, Minilec VSP3
Single Phase Preventer, 415V, GIC SM 301
MCX43,400A, 4P Contactor
250A, 4P, 36 KA, MCCB
125A, 3P, 36 KA, MCCB
160A, 3P, 36KA, MCCB
63A, 3P, 18KA, MCCB
LED Indication Lamps 22.5mm Hole Dia(Red/Green)
LED Indication Lamps 22.5mm Hole Dia(Blue)
240V AC daily Timer Switch
Star Delta electronic Timer relay- series Micon 225(Make: GIC)
40A, 2 Pole, AC-3 Contactor
16A, 12KV HRC Fuse
40A, 12KV HRC Fuse
63A, 12KV HRC Fuse
15W,6.6A/6.6A Isolating Transformer
100W,6.6A/6.6A Isolating Transformer
150W,6.6A/6.6A Isolating Transformer
200W,6.6A/6.6A Isolating Transformer
200W Bi Pin 6.6A Pre Focused halogen Lamp
150W Bi Pin 6.6A Pre Focused halogen Lamp
100W Bi Pin 6.6A Pre Focused halogen Lamp
Prefocused LED module with 1 W blue LED
Prefocused LED module with 1 W red LED
10-15W, 6.6A Blue Omni directional Inset Taxiway Edge light
240V, 6A day/night automatic sensor light control Switch
Supply of 12 feet Nylon Wind socks for Wind Direction Indicator
Supply of 330Wp Solar Panel of size 990mmX1960mm with Open circuit Voltage of 45.79, Voltage at maximum power 38.89V etc complete
AMC of NASU make following CCRs i/c reparing of defective CCRs by indentifying the fault, reparing of defective PCBs and other compennets and sevice the same , i/e calbration of CCRs and complete checking servicing on quarterly bais & submititng the reports etc, as required
HYDRO PNEUMATIC ENGINEERS HYD PVT LTD
Shri Sai Enterprises
Metro Electric Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .