| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | ₹8.5 L | L1 | Accepted-Finance 1st Lowest |
| 2 | L2₹8.5 LRejected-Finance A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | ₹8.5 L | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹8.7 LRejected-Finance | ₹8.7 L | L3 | Rejected-Finance 3rd Lowest |
| Sl No | Description | Qty | Unit | SKY DECORATIONS PRIVATE LIMITED L1 | MAXCOOL REFRIGERATION CO. L2 | JASODA REFRIGERATOR SERVICING CENTRE L3 |
|---|---|---|---|---|---|---|
| 1.00 | 7/8" (22.2 mm.) dia (Hard drawn) Cu. Pipes (As per standard BS 864 or ANSIB 16.22) mm incl. 9mm thick insulation. (Cu. Pipe Make- Nippon/Uniflow/Venam)Insulation Make- Suprime/A-Flex) | 15 | Rmt | 1,130 ₹16,950 | 1,135 ₹17,025 | 1,120 ₹16,800 Lowest |
| 2.00 | 1/2" (12.7 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS 864 or ANSIB 16.22).(Cu. Pipe Make- Nippon/Uniflow/Venam) | 15 | Rmt | 411 ₹6,165 Lowest | 413 ₹6,195 | 425 ₹6,375 |
| 3.00 | Dismentling & Cleaning of Existing Duct | 530 | Sq. Mtr | 142 ₹75,260 Lowest | 145 ₹76,850 | 150 ₹79,500 |
| 4.00 | Duct tharmal insulation by supplying and fixing of following thick-ness dully laminated aluminium foil of mat finish closed cell XLPE rubber (Class 'O' ) (Make- A-Flex/Suprime)insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as specification and as reqired. 9 mm | 530 | Sq. Mtr | 526 ₹2,78,780 Lowest | 530 ₹2,80,900 | 535 ₹2,83,550 |
| 5.00 | Duct acoustic insulation by supplying and fixing of following thick-ness finish Open cell Nitrile rubber (Class 'O' )(Make- A Flex/ Suprime) insulation on existing duct after applying suitable adhe-sive for Nitrile rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as specification and as reqired. 10mm | 89 | Sq. Mtr | 862 ₹76,718 | 865 ₹76,985 | 860 ₹76,540 Lowest |
| 6.00 | Dismentling & Cleaning of Defuser | 15 | Sq. Mtr | 1,371 ₹20,565 | 1,372 ₹20,580 | 1,370 ₹20,550 Lowest |
| 7.00 | Supply & Fixing of Powder Coated extruded aluminium Supply Air Defuser with aluminium volume controll dampers complete as per specification. | 2 | Sq. Mtr | 9,832 ₹19,664 Lowest | 9,835 ₹19,670 | 10,200 ₹20,400 |
| 8.00 | Supply & Fixing of Powder Coated extruded aluminium Return Air Defuser with louvers but without volume controll dampers complete as per specification. | 2 | Sq. Mtr | 7,449 ₹14,898 Lowest | 7,450 ₹14,900 | 7,450 ₹14,900 |
| 9.00 | Dismentling & Resupporting of Supply & Return Duct | 1 | Lot | 29,795 ₹29,795 Lowest | 29,795 ₹29,795 Lowest | 32,500 ₹32,500 |
| 10.00 | Supply & Fixing of 5.5 Tr Scroll Compressor consist of 66000 BTU/Hr. Cooling Capacity,R410A Refrigerant(Make- Copland/Tecomsh/Emerson) | 3 | Nos | 82,175 ₹2,46,525 Lowest | 82,200 ₹2,46,600 | 82,450 ₹2,47,350 |
Tender Value
Refer Docs
EMD Value
₹11,530
Closing Date
6 Mar 2026, 12:30 pmClosed
Executive Engineer, PWDte
Bankura
Repair and Renovation of damaged false ceiling with HVAC ducting along with whole electrical installation work including DG Set and Compound light at Rabindra Bhawan, Bankura.-------Repairing and Servicing of HVAC System.
2026_WBPWD_1016410_1
WBPWDTE/EE/BED/NIQ_84/Q of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Wise
45 days
Rabindra Bhawan, Bankura
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,530
25 Mar 2026
27 Feb 2026
9 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
7/8" (22.2 mm.) dia (Hard drawn) Cu. Pipes (As per standard BS 864 or ANSIB 16.22) mm incl. 9mm thick insulation. (Cu. Pipe Make- Nippon/Uniflow/Venam)Insulation Make- Suprime/A-Flex)
1/2" (12.7 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS 864 or ANSIB 16.22).(Cu. Pipe Make- Nippon/Uniflow/Venam)
Dismentling & Cleaning of Existing Duct
Duct tharmal insulation by supplying and fixing of following thick-ness dully laminated aluminium foil of mat finish closed cell XLPE rubber (Class 'O' ) (Make- A-Flex/Suprime)insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as specification and as reqired. 9 mm
Duct acoustic insulation by supplying and fixing of following thick-ness finish Open cell Nitrile rubber (Class 'O' )(Make- A Flex/ Suprime) insulation on existing duct after applying suitable adhe-sive for Nitrile rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as specification and as reqired. 10mm
Dismentling & Cleaning of Defuser
Supply & Fixing of Powder Coated extruded aluminium Supply Air Defuser with aluminium volume controll dampers complete as per specification.
Supply & Fixing of Powder Coated extruded aluminium Return Air Defuser with louvers but without volume controll dampers complete as per specification.
Dismentling & Resupporting of Supply & Return Duct
Supply & Fixing of 5.5 Tr Scroll Compressor consist of 66000 BTU/Hr. Cooling Capacity,R410A Refrigerant(Make- Copland/Tecomsh/Emerson)
Nitrogen Flashing, Leak testing & Vecumising of existing AC Machine
Charging R410A Refrigerant
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
BOQ_2496867.xls
BOQ • 0.35 MB
OID_documents.pdf
Tender Documents • 0.38 MB
2911.pdf
Additional Documents • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].