Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹23.2 L+₹2.3 L (11.3%)Rejected-AOC 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹23.9 L+₹3.0 L (14.4%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹25.3 L+₹4.4 L (21.1%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical NO REMARKS IN WLR QE DEC 2019 OF HQ CEWC |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
24 Jul 2020, 6:00 pmClosed
CWE(AF) Chandigarh
HQ CWE(AF) Chandigarh Pin - 160003
SPECIAL REPAIR TO UG BUILDING AT MPR AT AIR FORCE STATION AMRITSAR
2020_MES_354718_1
CWE/AF CHD/ASR-51/2019-2020
Open Tender
Civil Works
Item Rate
180 days
Amritsar
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I) AF Amritsar
₹49,000
Yes
6 Aug 2020
22 Jun 2020
28 Jul 2020
22 Jun 2020
24 Jul 2020
10 Jul 2020
Amount
Dismantling of brick tiles, or terracing tiles single layer, in roofs pointed in Cement Mortar, stacking serviceable brick tiles, brick bats, for re-use or credit and removal of rubbish outside MoD land, complete all as specified and directed.
Demolition of mud on roofs, any thickness, including plaster and leeping plaster and bottom layer of polythene film if any, including removal of retrieved material outside defence land, complete all as specified directed.
Roughening surface of old concrete floor by picking and sweeping, cleaning and washihg down with water to remove all loose dirt/ dust etc and disposal of rubbish outside MoD Land, complete all as specified and directed.
Material and labour for cleanig the new or old concrete surface and applying water proofing treatment to RCC roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30litre/Sqm including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60Kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps (100mm side lap and 150 mm end lap ) & joints with flame (by torch flame application) all as per manufacturer’s instructions, complete all as specified and directed.
Material and labour, plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in padding on roof, of required thickness to maintain desired slope, finished even and fair to receive tiles/ APP membrane, complete all as specified and directed.
Material and labour, cement concrete tiles, size 25cmx25cmx22mm, set jointed and pointed in neat cement slurry @ 3Kg/Sqm, in roof over and including 15mm thick screed bed, in CM (1:6) and pointed with grey cement and no pigment to match the shade of tiles, complete all as specified and directed.
Material and labour, Cutting groove in brick wall, 75mm wide and 65mm deep, for inserting APP polymer membrane and shaping horizontal face of groove with cement mortar 1:3, including removal of rubbish outside MoD land, complete all as specified and directed.
Material and labour, cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, as in roof kerb including use and waste necessary form work, complete all as specified and directed.
Demolition of cement concrete (unreinforced), of any description & in any position (below or above ground level), not exceeding 15cm thickness, including removal of rubbish outside MoD land, complete all as specified and directed.
Material and labour, 100mm thick plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in sub base, finished the surface even & fair, complete all as specified and directed.
Material and labour, 25mm thick Plain cement concrete (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate, as in floors, complete all as specified and directed.
Material and labour, Vitrified Ceramic light coloured tiles 10 mm thick (square/ rectangular) polished, area of each tile exceeding 0.36 sqm but n.exc. 0.42 Sqm, laid in floors etc with and including 15mm thick screed bed/bedding layer in CM (1:4). set and jointed in neat cement slurry @ 3Kg/Sqm, and pointed in coloured cement or white cement mixed with pigment to match the tiles, complete all as specified and directed.
Material and Labour, machine cut Kota stone slab 20-25 mm thick, as in floors, treads of steps, laid over and including screed bed/bedding layer 20mm thick in CM (1:4), set in neat cement slurry @ 3kg/sqm, and pointed with grey cement slurry mixed with pigment to match the shade of the slab, including curing, rubbing and polishing, complete all as specified and directed.
Material and Labour, machine cut Kota stone slab 20-25 mm thick, as in skirting, risers to steps and similar vertical surfaces, laid on and including backing coat 10mm thick in CM (1:4), set in neat cement slurry @ 3kg/sqm, and pointed with grey cement slurry mixed with pigment to match the shade of the slab, including curing, rubbing and polishing, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/backing and removing rubbish off the premises of MoD land, including preparation of dismantled surface area to receive backing coat/bedding layer for tiles, complete all as specified and directed.
Material and labour, first quality Non Skid ceramic coloured tiles 7 to 8mm thick, (squares/rectangular), area of each tile exceeding 0.06Sqm but not exceeding 0.11qm, in floors etc, set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white cement mixed with pigment or coloured cement to match the shade of tiles, over and including 15mm thick screed bed/bedding layer in CM (1:4), complete all as specified and directed.
Material and labour, First quality, glazed ceramic coloured tiles, 7mm thick, of size 350mm x 250mm, as in skirting, dados, risers to steps, etc., set and jointed in neat cement slurry @ 3Kg/Sqm, over and including 10mm thick rendering of cement mortar (1:4), including pointing in white cement mixed with pigment or coloured cement to match the shade of tiles, complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and removal from site, complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position and removal from site, complete all as specified and directed.
Dismantling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section and removal from site, complete all as specified and directed
Supply and Fixing, 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing in SSR Part-II, complete all as specified and directed.
Supply and Fixing, Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing in SSR Part-II, complete all as specified and directed.
Supply and Fixing, anodized aluminium snap grid frame work (Grid Section bevelled tegular XL 15mm silhouette) for false ceiling, size of grid 605mm x 605mm, including 6mm dia GI hanger and adjusting level, fixed to slab by means of ceiling cleats made out of GI flat 40 x 3 mm and fixing in position 600mm x 600mm x 9mm size, dune finished bevelled tegular gypsum board H365B, complete all as specified and directed. Makes of Materials:- (i) Aluminum Section : VALCO, HINDALCO, JINDAL (II) Gypsum Board :- GYPSUM INDIA LTD / LA GYP ECO BOARD
Taking down cement plaster on brick or stone walls or concrete surfaces, etc, any description including raking out joints, hacking for key, scrubbing down with water, etc and removal of rubbish outside MoD land, complete all as specified and directed.
Material and labour, rendering 10 mm thick on ceiling, chajja and the like in CM (1:3), finished even and smooth without using extra cement, complete all as specified and directed.
Material and labour, preparing new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
Dismantling of brick masonry work built in cement mortar including all quoins, arches, pillars, staging etc. including segregating and stacking serviceable bricks & brick bats and removal of rubbish outside defence land, complete all as specified and directed.
Material and labour, brick work with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6), complete all as specified and directed.
Material and labour, brick work with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius, as in half brick thick walls, built in CM (1:4), complete all as specified and directed.
Material and labour, rendering 15mm thick plaster on fair faces of brick walls or concrete surfaces in CM (1:6), in two layers i.e. 10mm in CM (1:6) and 5mm in CM 1:6) mixed with approved WPC @3% by weight of cement in 5mm layer only and finished fair & even without using extra cement, complete all as specified and directed. Note: WPC shall be measured and paid separately.
Material and labour, rendering 15mm thick plaster on fair faces of brick walls or concrete surfaces in CM (1:4), in two layers i.e. 10mm in CM (1:4) and 5mm in CM 1:4) mixed with approved WPC @3% by weight of cement in 5mm layer only and finished fair & even without using extra cement, complete all as specified and directed. Note: WPC shall be measured and paid separately.
Supply only intergral water proofing compound, ISI Marked, of specified make, for mixing in cement under respective items where specified, complete all as specified and directed.
Material & labour, preparation of new (plastered) surfaces of walls including brooming down, and steel wire brushing/scrapping down where required; to remove efflorescent salts spots etc.; washing, rubbing down using sand paper and applying two coats of exterior acrylic emulsion (1st quality paint), in disruptive pattern camouflage using percentage of colours as 70% dark green and 30% sand stone or number of colours as approved, over and including a coat of primer, complete all as specified and directed. Note: Pattern of camouflage shall be as approved by GE.
Material and labour, preparation of newly plastered surfaces of walls and applying two coats of 1st quality oil bound distemper (oil emulsion) , complete all as specified and directed.
Material & labour, complete removal of existing / old decoration i.e paint from unplastered/ plastered surfaces of walls using steel wire brushes, scraping down to remove efflorescent salts, grease spots, moulds, moss, etc., including brooming down, washing, rubbing down using sand paper, including stopping of distrubed surfaces, planes/edges with white cement putty & rubbing with sand paper to obtain regular and smooth surfaces, and applying one coat of exterior acrylic emulsion anti weather & anti algae paint (1st quality paint), complete all as specified and directed.
Material and labour, preparation of old plastered surfaces of walls and applying two coats of 1st quality oil bound distemper (oil emulsion) , complete all as specified and directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frame), of any description, not exc 1.5Sqm each, and removal to store for reuse or credit, complete all as specified and directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frame), of any description, exceeding 1.50Sqm but not exc 4.0Sqm each, and removal to store for reuse or credit, complete all as specified and directed.
Supply and Fixing, Anodised aluminium frame for doors, windows, ventilators with one or more rebates, powder coated any colour (minimum thickness of powder coating 50 micron) including joining cleat for fixing etc, complete all as specified and directed.
Supply and Fixing, Anodised aluminium door shutters, aluminium section weighing 0.55kg/m, powder coated any colour (minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc., complete all as specified and directed.
Supply and fixing, pressed steel frames for doors with one or more rebate, size of frame 105mm x 60mm, made out of 1.25mm thick MS Sheet including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed.
Supply and fixing, 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, chemically treated against termite infestation, complete all as specified and directed
Supply and fix, butt hinges, 100mm long, medium weight, cold rolled mild steel, bright finished, complete all as specified and directed.
Supply and fixing, Aluminium anodized handle 150mm long, extruded, fabricated type, powder coated, complete all as specified and directed.
Supply and Fixing, Aluminium anodised, barrel tower bolts 150mm long, powder coated, of extruded section and fixed, complete all as specified and directed.
Supply and Fixing, Aluminium alloy anodised sliding door bolts 250mm long, with hasp & staple and fixing clips, of sheet cast or fabricated section and plate type, bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all specified and directed.
Supply and Fixing, Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 140mm, complete with vulcanised rubber piece including making sinking in floor, fixed in floor , complete all as specified and directed.
Supply and fix, factory made steel window box type, primer coated, comprising ERW Hollow 'P' Section of size 60mmx25mm of 1.25mm wall thickness frame, single rebated, glazed and skeleton shutter made of ERW section 50mmx20mm of 1mm wall thickness, and operated leaf side top hung, divided in three panels with two Nos. sash bars of 'T' section 20mmx3mm welded to frame of shutter and openable shutter prepared to recieve sheet glass, including provision of flat iron rivetted bolt to secure wire mesh, cutting holes 04Nos. for each window for hold fasts, 150x230x75mm, PCC 1:2:4 type B-1 using 20mm graded stone aggregate as for hold fasts including necessary form work, complete including following fittings welded to frame/ shutter:- (a) Hold fast 150mm long out of 25x6mm flat iron made to shape- 04 Nos. each window (02Nos. on each side). (b) Handle of 'Z' section 20mmx25mm, 100mm long- 01No. each leaf. (c) MS tower bolt 150mm long- 02 Nos. each leaf. (d) 'Z' section 20mmx25mm, 100mm long stopper 01 No. each leaf. (e) Cleat 55mm long of hollow square section 15mmx15mm of 24 guage wall thickness, welded to hinge of 55mm size 01 No. per leaf. (f) MS box type hinges of 75 mm size- 03Nos. per leaf. (g) Fabrication & fixing complete. Note(s): (i) Glass panes & painting shall be measured & paid separately under respective items. (ii) Design shall be approved from GE as per Drawing No. CEAF/STD-170/07 sheet 1/4 to 4/4 before fabrication and placing bulk order to the manufacturer.
Supply and fix, factory made steel window box type, primer coated, comprising ERW Hollow 'P' Section of size 60mmx25mm of 1.25mm wall thickness frame, single rebated, glazed and skeleton shutter made of ERW section 50mmx20mm of 1mm wall thickness, and operated leaf side top hung, divided in three panels with two Nos. sash bars of 'T' section 20mmx3mm welded to frame of shutter and openable shutter prepared to recieve wire gauge, including provision of flat iron rivetted bolt to secure wire mesh, cutting holes 04Nos. for each window for hold fasts, 150x230x75mm, PCC 1:2:4 type B-1 using 20mm graded stone aggregate as for hold fasts including necessary form work, complete including following fittings welded to frame/ shutter:- (a) Hold fast 150mm long out of 25x6mm flat iron made to shape- 04 Nos. each window (02Nos. on each side). (b) Handle of 'Z' section 20mmx25mm, 100mm long- 01No. each leaf. (c) MS tower bolt 150mm long- 02 Nos. each leaf. (d) 'Z' section 20mmx25mm, 100mm long stopper 01 No. each leaf. (e) Cleat 55mm long of hollow square section 15mmx15mm of 24 guage wall thickness, welded to hinge of 55mm size 01 No. per leaf. (f) MS box type hinges of 75 mm size- 03Nos. per leaf. (g) Fabrication & fixing complete. Note(s): (i) wire gauge/mesh & painting shall be measured & paid separately under respective items. (ii) Design shall be approved from GE as per Drawing No. CEAF/STD-170/07 sheet 1/4 to 4/4 before fabrication and placing bulk order to the manufacturer.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Material and labour, Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.
Supply and Fixing, Rolled mild steel Fe 410-W (Gde-E-250) quality-B, as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated or required), complete all as specified and directed.
Supply and Fixing, Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, Semi corrugated, etc.) sheets in roof coverings, and removal from site to store for reuse or credit, complete all as specified and directed.
Supply and fixing, pre-painted galvalume aluminium zinc coating mild steel corrugated sheets 0.50mm thick , having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws, complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floor), beams, staircase, landing, chajjas, shelves and similar suspended work, including cutting of reinforcement to facilitate demolition and removal of debris outside MoD land, complete all as specified and directed.
Material and labour, Reinforced Cement Concrete (1:2:4) type B-1, using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed. Note : Steel reinforcement bars and use and waste form work shall be measured and paid separately.
Material and labour, Reinforced Cement Concrete (1:2:4) type B-1, using 20mm graded crushed stone aggregate as in slab supported walls, beams and columns in floor, roofs, landings, balconies etc, complete all as specified and directed. Note : Steel reinforcement bars and use and waste form work shall be measured and paid separately.
Use and waste, formwork to sides and soffits of beams, cantilevers, bressummers etc, flat, fair finished surfaces, complete all as specified and directed.
Use and waste, formwork to slab supported walls, beams and columns in floor, roofs, landings, balconies etc, complete all as specified and directed.
Supply and fix in position, mild steel bars TMT, 10mm dia and over, cut to length, bent to shape required, including cranking, bending for hooping of columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, as in reinforcement, complete all as specified and directed.
Supply and fix in position, mild steel TMT bars 6mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Supply and fixing, Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
Supply and Fixing, galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm, fixed with screws or beading in steel / wooden door/ window, as in repairs, complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete/metal frames or brick surrounds, glazed with putty or fixed with beads, and removal outside MoD land, complete all as specified and directed.
Supply and fix, plain sheet glass 3mm thick, ordinary quality, not exceeding 0.50Sqm in each pane, and glazing with oil putty and securing pins, spring clips etc, complete all as specified and directed.
Material and labour, applying two coats of synthetic enamel paint over and including a coat of red oxide primer, on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed.
Material and labour for preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Material and labour, 75mm thick plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in sub base, finished the surface even & fair, complete all as specified and directed.
Material and Labour, Precast Chequered cement concrete tiles 30 cm x 30 cm x 22 to 25 mm thick, with grey cement and pigment (coloured), epoxy coated, set using neat cement slurry @ 3kg/sqm and jointed in neat cement slurry, and pointed in coloured cement or white cement mixed with pigment to match the surface, laid over and including 15mm thick screed bed or bedding layer in CM (1:4), complete all as specified and directed.
Material and Labour, 25mm thick Sand filling under floors including watering and consolidation, complete all specified and directed.
Material and Labour, Machine pressed precast concrete interlocking paver block of 60mm thickness, M-35 Grade, with grey cement and pigment, any shape and size, confirming to IS 15658-2006, complete all specified and directed.
Material and labour, plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection, 75mm thick, (laid to slope of 1:20) finished even and smooth without using extra cement, with 10mm wide joints to full depth @ 3m c/c and at corners, filled with mastic mortar, complete all as specified and directed.
Material and Labour for PCC (1:2:4) type B-1, using 20mm graded crushed stone aggregates, as in surface channel and drains, including necessary form work, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth (of cement concrete), using extra cement @ 3Kg/sqm, including forms, moulds, mitred / stopper ends etc., complete all as specified and directed.
Material and Labour, Cement concrete (1:4:8) type D-2, using 40mm graded broken stone aggregate as in foundations filling and mass concrete, complete all as specified and directed.
Taking down existing copper/aluminium conductor point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, bell/buzzers, regulators, sockets etc, and removing materials to store for keeping in safe custody or for taking credit (credit for above items shall be made as per condition of items separately), and making good disturbed surface of walls, ceiling, etc, complete all as specified and directed.
Material and labour, point wiring with single core multi stranded copper conductor 1.5Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100volts grade drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including M.S. sunken boxes of suitable size made of 1.6mm thick sheet duly painted with anticorrosive paint, for housing switches, fan regulators etc, PVC cover sheet 3mm thick (Make : Hylam, Plaza, Havells, Kalinga) including 1.5Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100volts grade for earth continuity, as for one light/fan/bell point (through regulator), controlled by one switch, complete all as specified and directed. Note : 1. Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. 2. Switches and fan regulator shall be measured and paid separately.
All as per Serial Item No. 79.00 here-in-before but for one socket outlet 3pin, 6Amp, on the same board.
All as per Serial Item No. 79.00 here-in-before but for one socket outlet 3pin, 6Amp, on independent board.
Material and labour, point wiring complete with single core multi stranded Copper conductor of size 2.5Sqmm (nominal area) FRLS PVC insulated unsheathed 1100 volt grade colour code cable, drawn in and including non metalic rigid PVC conduit medium grade of suitable size including standard fittings such as Tee junction, bends etc, conduit concealed in wall & fixed on ceiling including M.S. sunken boxes of suitable size made out of 1.6 mm thick sheet duly painted with anticorrosive paint for housing switches, sockets etc, PVC cover sheet 3mm thick including one 1.5Sqmm size (nominal area) multi stranded copper conductor FRLS PVC insulated unsheathed colour code cable for earth continuity, for one multi purpose socket outlet 6 pin, 15Amps & 5Amps on independent board, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii) Switches etc. shall be measured and paid separately. Circuit wiring from distribution board to switch board shall be deemed included in the quoted rate of point wiring.
Supply and fix, switch piano, flush type, single pole, one way, 5Amps, 230volts, complete all as specified and directed.
Supply and fix, switch piano, flush type, single pole, one way, 15Amp, 230volts, complete all as specified and directed.
Supply and fix, socket outlet, flush type, 2 in 1, multi purpose 6 pin, 5Amps, 230 volts, complete all as specified and directed.
Supply and fix, socket outlet, flush type, 2 in 1, multi purpose 6 pin, 5Amps & 15Amps, 230 volts, complete all as specified and directed.
Supply and fix, ceiling rose, surface bakelite, polycarbonate / PVC isolated body, 65mmx50mm, two to three terminals, (ISI marked), complete all as specified and directed.
Supply and fix, Lamp Holder, insulated body, bakelite/ PVC/Polycarbonate type, with back plate suitable for batten fittings/ conduit (as required), complete all as specified and directed.
Supply and fix in repair, LED tube light fitting, 1x20W with PVC insulated flexible copper conductor cable from ceiling rose to tube light fitting, complete all as specified and directed. Make :- Havells Cat Part No. LHEXBLP7PN1W020 or equivalent as per Appx 'B'.
Supply and fix in repair, SMD LED panel recess/surface suspended mounting 42W 2'x2' ceiling light with extruded aluminium housing and milky diffuser, complete all as specified and directed. Make :- Havells Cat Part No. PLUTONEO2X2PLR42WLED857S or equivalent as per Appx 'B'.
Supply and fix, electronic fan regulator, step type (4/5 step), for ceiling fans including necessary connections 240 Volt, 50Hz, 300 watt capacity, complete all as specified and directed.
Supply and fix in repair, Sheet Metal Enclosure Distribution Board (DB), company made, metallic double door, vertical, single pole and neutral, 8way, 240Volt with 200Amps rated insulated bus bar, IP-43, complete all as specified and directed.
Supply and fix in repair, MCB DP 40Amps, 240volts, 10KA,'B' curve/ series, complete all as specified and directed.
Supply and fix in repair, MCB SP 6-32Amps, 240volts, 10KA,'B' curve / series, complete all as specified and directed.
Supply and fix in repair, sheet metal enclosure distribution board (DB), vertical type, metalic double door, TPN, 12way, 415Volt, with 200Amps rated insulated bus bar, IP-43, with incoming MCCB 160Amps, 3Pole, 415Volt, 50Hz, AC, 25 KA (adjustable thermal and fixed magnetic release) - 01 No., neutral link, blanking plates etc., complete all as specified and directed.
Supply and fix in repair, sheet metal enclosure single pole and neutral with a two pin & earth plug and socket etc, powder coated, complete with one single pole MCB 20Amps, 'B' series, 240volts, 10 KA, complete all as specified and directed
Material and labour, sub main wiring with two single core, 1100 V grade, 6.0 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor FRLS, drawn in and including non metallic rigid PVC concealed conduit medium duty with all standard accessories including one run of continuous PVC insulated unsheathed stranded copper conductor FRLS cable 4.0 Sqmm (nominal area) as continuous earth conductor cable connected to earth dolly, complete all as specified and directed. Note(s) :- (i) 2 runs of 6.0 Sqmm main cable +1 run of 4.0 Sqmm for earth cable and conduit shall be measured as one unit/one Running Metre. (ii) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required
Material and labour, sub main wiring with two single core 4Sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cables drawn in and including non metallic PVC rigid conduit medium grade of suitable size with all standard fittings, concealed, including one run of continuous PVC insulated stranded copper conductor FRLS cable 2.5Sqmm (nominal area) for earth continuity, complete all as specified and directed. Note :- (i) Two runs of 4Sqmm main cable + one run of 2.5Sqmm for earth cable & conduit shall be measured as one unit/one Running Metre. (ii) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required
Material & labour, earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009) including taking down old, complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
Material and labour, earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 25mmx4mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI light grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including taking out the existing u/s earthing materials all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Material and labour for earthing complete Supply of advance JK CHEM RODE/LPI (AUSTRALIA)/Alltec chemical earthing system of Copper pipe Chemical rod of 3 mtrs long 50mm dia filled with highly conducting metallic compounds with the permanent sealing at both the ends. Top of the earth electrode is compressed to form an extended lead with 2 holes for connecting the strips/wire to the load. To ensure the moisture content and electrical conductivity LPI AUSTRALIA Compound LPI Reslow (Soil Resistance Improvement Material) Weight & Packaging-20 KG each bag with laminated woven poly bag of 420mm width x 695mm height Standard - Compliance with International standard IEC 62561 - Part-7, Tested - By Australian University and NATA Certified Lab, Electrical Resistivity - 0.15 ohm. , Chemical Composition - Carbon bases resistance lowering capacity, each earthing 02 bags of 20 kgs Reslow. An arrangement for connection of copper strip (25x3mm) from location where earthing required to rod connected by means Given Terminal point with SS Nut, Bolts including necessary insulators, test link and brazing work if required for joint, provision of polymer chamber with cover, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil complete all as specified and as directed Make : JK CHEM RODE/LPI (AUSTRALIA) Compound/Alltec/Akalltech.
Notes:- (i) Polymer chamber with cover should be provided instead of earth pit cover. (ii) Rate shall included copper strip and GI protection as per site. (iii) Earth resistance should be less than 1.0 Ohm, in case the test result are not found below 1.0 Ohm, complete earthing will be redone without any extra cost to Govt. (iv) For effective visibility identification and traceability of earth pit with corresponding earth of equipment and building, markers in metal (mild steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of mild steel identification board shall be provided by Engineer-in-Charge. (v) The work is to be carried out in replacement of existing earthing. The quoted rate shall be deemed to included for taking out, dismantling and disposal of old earthing. (vi) All joints of strip are to be brazed on both sides (over lapping) except test point.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 70Sqmm 3.5 core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable under item No. 102 to 104 shall be measured and paid separately.
All as per Serial Item No. 102 here-in-before but 50Sqmm 3.5Core size
All as per Serial Item No. 102 here-in-before but 16Sqmm 2Core size
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material and labour, locally available, sub class `B’ bricks (old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 50mm bore for cable protection, laid in trenches or fixed to pole/wall or laid under floor/road/pavement including all fittings, complete all as specified and directed.
Supply and fix in replacement, LED street light 60W with pressure dia cast aluminium and heat resistance glass with high brightness LED's as light source, IP-66 protection, including driver and consisting of the following specification. System Lumens 6000, efficiency 100 Lumen/Watt, CRI>70, Power factor >.90 colour temp, 6500K, THD<10%. Driver must be constant current type and inbuilt surge protection. Make: Havells Cat No. ENDURAPEARLPLUSSL60WLED757SASYTOPC or equivalent in Appendix 'B'.
Supply and fixing, bracket 1.2m long made to shape (bend at 80/40cm) out of GI Pipe 40mm bore, medium grade, complete with two sets of fixing clamps made to shape out of MS flat 40mmx6mm of appropriate length, including MS bolts & nuts, washers etc, fixed to pole etc., complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of factory made tested (Including CPRI type tested certificate) LT panel board cubical outdoor type of size 0.75 x 0.75 x 0.40 mtrs, plate mounted suitable for, 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bar of rating 400 Amp installed on porcelain/SMC insulator. The panel shall be dust and vermin proof IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apron for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked, 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size etc all as directed with the following fitments :- (a) MCCB 4 pole 415 volts 250 amp rating braking capacity 36 KA incoming (Adjustable Overload 40-100%) -01 No (b) Bus bar : Providing suitable size of Bus bar of copper 400 amp rating with coloured heat shrinkable insulated sleeves 415 volts as per IS of suitable size mounted on DMC/epoxy insulator- 01 No.
Supply, installation, testing and commissioning in replacement of fire alarm system consisting of Photoelectric type Smoke detectors, hooter, manual call points and fire alarm panel with complete wiring in PVC conduit Pipe with twin core 1.5 Sqmm copper cable FRLS and complete accessories etc as required at site complete all as specified and directed. The system comprises with following :- (i) Photoelectric type Smoke Detector with base - 11 Nos. Make:- Apollo 65 Series/Lakshita/Qutak (ii) Manual Call Point-01 No. Make- Agni/Lakshita/Qutak. (iii) Electric Hooter - 01 No. Make- Agni/Lakshita/Qutak. (iv) FIRE Alarm Panel with 2 x 12 volt/7AH Battery of suitable capacity - 01 Nos, Make- Agni/Lakshita/Qutak.
Note: The Total amount shall subject to adjustment of credit of Rs. 49461.00 for old Materials as per Schedule of Credit
M/S MAHAJAN CONSTRUCTION CO
kapoor and co
MAAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .