Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | L1 | Accepted-AOC Being first lowest | |
| 2 | L2₹14.3 L+₹12,690 (0.89%)Rejected-Finance | L2 | Rejected-Finance Other Than First lowest | |
| 3 | L3₹14.4 L+₹24,986 (1.76%)Rejected-Finance | L3 | Rejected-Finance Other Than First lowest | |
| 4 | L4₹16.1 L+₹1.9 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Other Than First lowest | |
| 5 | L5₹18.3 L+₹4.1 L (29.2%)Rejected-Finance | L5 | Rejected-Finance Other Than First lowest |
| Sl No | Description | Qty | Unit | M/S JALANDRA CONSTRUCTIONS L5 | LAKSHMI ASSOCIATES L3 | M/S Anil Enterprises L4 | M/S TRADE LINKERS L2 | M/S Sheeba Enterprises L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminum /copper point wiring, casing capping /PVC concealed conduit for (light, fan, socket, bell or power etc) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed. | 627 | Per Point | 10 ₹6,270 Lowest | 21 ₹13,167 | 18 ₹11,286 | 30 ₹18,810 | 10 ₹6,270 Lowest |
| 2.00 | Taking down light fittings of any type any make any capacity complete all as specified and directed. | 50 | Each | 10 ₹500 Lowest | 30 ₹1,500 | 50 ₹2,500 | 50 ₹2,500 | 10 ₹500 Lowest |
| 3.00 | M&L for modular point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable, single core, 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn through and including concealed rigid non metallic PVC conduit medium grade of size not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor including cutting chases in walls for conduits and sunken boxes etc incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one light/fan/exhaust fan point controlled by one, one way switch 6 Amp and making good the disturbed portion as per existing complete all as specified and directed. | 97 | Per Point | 850 ₹82,450 | 551 ₹53,447 | 550 ₹53,350 | 450 ₹43,650 Lowest | 850 ₹82,450 |
| 4.00 | ,---ditto--- all as per item No. 3 above but for one 3 pin 5 Amp socket outlet controlled by one switch on indepdendent board complete all as specified and directed. | 70 | Per Point | 600 ₹42,000 | 551 ₹38,570 | 600 ₹42,000 | 480 ₹33,600 Lowest | 700 ₹49,000 |
| 5.00 | ,---ditto--- all as per item No. 3 above but for one 3 pin 5 Amp socket outlet controlled by one switch on same board with other switches complete all as specified and directed. | 60 | Per Point | 600 ₹36,000 | 300 ₹18,000 | 100 ₹6,000 | 150 ₹9,000 | 50 ₹3,000 Lowest |
| 6.00 | ,---ditto--- all as per item No. 3 above but for one light point controlled by two, two way switch complete all as specified and directed. | 40 | Per Point | 600 ₹24,000 | 606 ₹24,240 | 650 ₹26,000 | 500 ₹20,000 Lowest | 750 ₹30,000 |
| 7.00 | ,---ditto--- all as per item No. 3 above but for one bell point controlled by one bell push complete all as specified and directed. | 20 | Per Point | 600 ₹12,000 | 660 ₹13,200 | 650 ₹13,000 | 465 ₹9,300 Lowest | 700 ₹14,000 |
| 8.00 | M&L for modular point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable, single core, 4 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn through and including concealed rigid non metallic PVC conduit medium grade of size not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor including cutting chases in walls for conduits and sunken boxes etc incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one socket outlet 16 Amps on independent board and making good the disturbed portion as per existing complete all as specified and directed. | 50 | Per Point | 820 ₹41,000 | 850 ₹42,500 | 900 ₹45,000 | 800 ₹40,000 Lowest | 900 ₹45,000 |
| 9.00 | M&L for point wiring with 1100 volts grade PVC insulatd FRLSH multistranded copper conductor cable, single core, 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn through and including PVC casing-capping (double lock pattern) not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm thick covered with and including 3mm thick phenolic laminated/hylem white sheet cover fixed on wall / other surface with brass screws for mounting switches, sockets, fan regulators etc one light/fan/exhaust fan point controlled by one, one way switch 6 Amp and making good the disturbed portion as per existing complete all as specified and directed. | 70 | Per Point | 700 ₹49,000 | 515 ₹36,050 | 450 ₹31,500 Lowest | 450 ₹31,500 Lowest | 500 ₹35,000 |
| 10.00 | ,---ditto--- all as per item No. 9 above but for one 3 pin 5 Amp socket outlet controlled by one switch on same board with other switches omplete all as specified and directed. | 70 | Per Point | 600 ₹42,000 | 300 ₹21,000 | 100 ₹7,000 | 100 ₹7,000 | 50 ₹3,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
22 Apr 2026, 6:00 pmClosed
GE Jaipur
GE Jaipur
REPAIR / MAINT INTERNAL ELECTRIFICATION WORK IN MH AREA UNDER AGE E/M OF GE JAIPUR
2026_MES_758886_1
GE/J- /2025-26
Open Tender
Civil Works
Item Rate
270 days
GE Jaipur
As per Tender Documents
5 documents required · 5 mandatory
₹500
GE Jaipur
₹40,000
Yes
11 Jun 2026
1 Apr 2026
24 Apr 2026
1 Apr 2026
22 Apr 2026
16 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Taking down carefully aluminum /copper point wiring, casing capping /PVC concealed conduit for (light, fan, socket, bell or power etc) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed. | - | Per Point | - | - |
| - | Taking down light fittings of any type any make any capacity complete all as specified and directed. | - | Each | - | - |
| - | M&L for modular point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable, single core, 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn through and including concealed rigid non metallic PVC conduit medium grade of size not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor including cutting chases in walls for conduits and sunken boxes etc incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one light/fan/exhaust fan point controlled by one, one way switch 6 Amp and making good the disturbed portion as per existing complete all as specified and directed. | - | Per Point | - | - |
| - | ,---ditto--- all as per item No. 3 above but for one 3 pin 5 Amp socket outlet controlled by one switch on indepdendent board complete all as specified and directed. | - | Per Point | - | - |
| - | ,---ditto--- all as per item No. 3 above but for one 3 pin 5 Amp socket outlet controlled by one switch on same board with other switches complete all as specified and directed. | - | Per Point | - | - |
| - | ,---ditto--- all as per item No. 3 above but for one light point controlled by two, two way switch complete all as specified and directed. | - | Per Point | - | - |
| - | ,---ditto--- all as per item No. 3 above but for one bell point controlled by one bell push complete all as specified and directed. | - | Per Point | - | - |
| - | M&L for modular point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable, single core, 4 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn through and including concealed rigid non metallic PVC conduit medium grade of size not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor including cutting chases in walls for conduits and sunken boxes etc incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one socket outlet 16 Amps on independent board and making good the disturbed portion as per existing complete all as specified and directed. | - | Per Point | - | - |
| - | M&L for point wiring with 1100 volts grade PVC insulatd FRLSH multistranded copper conductor cable, single core, 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn through and including PVC casing-capping (double lock pattern) not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm thick covered with and including 3mm thick phenolic laminated/hylem white sheet cover fixed on wall / other surface with brass screws for mounting switches, sockets, fan regulators etc one light/fan/exhaust fan point controlled by one, one way switch 6 Amp and making good the disturbed portion as per existing complete all as specified and directed. | - | Per Point | - | - |
| - | ,---ditto--- all as per item No. 9 above but for one 3 pin 5 Amp socket outlet controlled by one switch on same board with other switches omplete all as specified and directed. | - | Per Point | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_850024.xls
BOQ • 0.48 MB
Tender.pdf
Tender Documents • 1.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .