| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹12.9 L+₹42,036.60 (3.37%)Rejected-AOC 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹13.7 L+₹1.2 L (9.63%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹14.4 L+₹1.9 L (15.6%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | Rejected-Technical | - | Rejected-Technical Invalid DD uploaded |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
9 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
CERTAIN REPAIRS TO MISC B/R INCLUDING PERIODICAL SERVICES AT INS TRATA (FSB ERANGAL) UNDER GE(NW) BHANDUP
2023_MES_631252_1
8312/B
Open Tender
Civil Works
Item Rate
270 days
Hamla
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹28,000
Yes
19 Mar 2024
5 Dec 2023
10 Jan 2024
5 Dec 2023
9 Jan 2024
26 Dec 2023
5 Dec 2023 - 15 Dec 2023
Amount
M&L for preparation of old decorated surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying one coat of white wash complete all as specified and directed.
M&L for preparation of old surfaces of walls including washing, rubbing down and stopping of distempered and painted surfaces of wall and applying one coat oil bound distemper with roller complete all as specified and directed.
M & L for complete removal of existing treatment by scrapping / washing down with water and applying two coats of oil bound distemper over a coat of primer, applying with roller complete all as specified and directed.
M & L white cement based Wall care putty not less than 1mm thick on wall/ceiling new or old surfaces of any description finished even and smooth complete all as specified and directed.
M&L for preparation of old decorated wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint. complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old/new surfaces of walls/slab projections by brooming down or steel wire brushing scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots including washing down,with water and applying one coat of 100% antifungal acrylic emulsion paint in approved shade etc all as per manufacturers instructions including necessary scaffoldings etc,complete all as specified and as directed.
M & L for cutting out cracks (not exc 5mm) to V-section in existing wall/chajjas and cleaning out and filling up with Dr fixit crack seal including necessary scaffoldings complete all as specified and as directed.
Taking down cement mortar or lime plaster of any description from stone or brick wall etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials out side MD and including necessary scaffoldings complete all as specified and directed
M & L for Rendering 15mm thick in (1:6) CM on fair faces of brick work or concrete surfaces of walls and finishing even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 as in ceiling finishing even and smooth (with out using extra cement) etc complete all as specified and directed.
M&L for Rendering 20mm thick in (1:4) cm (in two coats (15+5mm) with both coats mixed with liquid water proofing compound, surface finished even and fair without using extra cement complete all as specified and directed. ( Note : WPC will be measured separately).
M&L for preparation of new plastered surfaces and applying three coats of cement base paint on wall complete all as specified and directed
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling etc complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer using roller etc complete all as specified and directed.
M&L for Removal of plant growth by injection with chemical glyphospate solution ( 4 % conceneration ) @ 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm. The area shall then be sprayed with solution 25ml glyphosphate ( 4% concent) dulited with 1 ltr of water. All roots / plants shall be removed completely and making good the distrubed surface and painted with cement base or acrylic paint all as directed by EIC.
Supply only polymer based liquid water proofing compound complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutter from the frames) exceeding 1.5 sqm but n exc 4 sqm completed as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq. M each
Taking down shutter of any description exc 1.00 but n exc 2.00 sqm each complete all as specified and directed.
Resecuring or easing & adjusting without taking down door shutter of any description exc 1.00 but n exc 2.00 Sqm each complete all as specified and directed.
Taking down door shutter of any description exc 1.00 but n exc 2.00 sqm each and refixing in the same opening after easing, adjusting & renewal of unserviceable screws etc complete all as specified and directed.
Taking down door shutter of any description n exc 1.00 sqm each and refixing in the same opening after easing, adjusting & renewal of unserviceable screws as required etc complete all as specified and directed.
M&L for Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted & fixed in position in repairs all as specified of 1000 ltrs capacity complete all as specified and directed..
M&L in repairs Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete .25mm dia complete all as specified and directed.
M&L Nipple suitable for HDPE water tank (minimum weight 25mm - 65 gms) 20mm bore dia complete all as specified and directed
M&L for post construction anti- termite traetment along the external wall below concreate or masonary apron using chemical emulsion @2.25 liters per linear meter including drilling and plugging holes with cement morter 1:2 to match the existng floor etc complete all as specified and directed.
M&L for post construction anti- termite of soil / concreate under existing floor along the floor and wall junction using chemical emulsion @ 1 liters per hole 300 mm apart including drilling and plugging 12 mm dia holes with cement morter 1:2 to match the existing floor etc complete all as specified and directed.
M & L for post construction anti - termit treatment at points of contract of wood work using chemical emulision (in oil or kerosin based solution ) @ 0.5 liters per holy by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centre to centre and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
M&L, 18 to 20 mm thick M/C and M/C polished Kota stone slab in single piece in jambs and in double piece in cills on vertical surfaces and over 15mm thick cement mortar 1:3 backing coat jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing and necessary edge moulding before fixing of kota stone complete.
S&F extruded Powder coated aluminium section as in window, ventilation,door (powder coated 50 micron in blackcolour) with movable, openable or fixed type shutter or any pattern as directed, aluminumsection medium weight of series B or size as directed by the Engr in charge cut to size , jointed toghter including rubber beading and all necessary fitting complete all as specfied and directed. Note :- (i) Only aluminum sections measured and paid in this item. (ii) Rate quoted by the contractor shall deemed to be inclusive of all neecssary fittings and fixture such as roller,handle,locks etc (iii) Glass pane and XPM jali measured and paid under supply only rate.
S & F aluminium grill conforming to DG- 102 of Deco Grill or equivalent , (10mm X 5.2mm) thick of approved design or equivalent as approved by Accepting Officer and fixing with and including 'F/U' channel not less than 1.5mm thick and fixed in repairs complete all as specified and directed.
Supply only sheet glass 4.8 mm thick in glazing n exc 0.5 sqm each with rubber and aluminium beading/packing with rubber gasket complete as specified and directed.
Supply & Fixing in repairs sheet glass 4.8 mm thick in glazing n exc 0.5 sqm each with rubber and aluminium beading/packing with rubber gasket complete as specified and directed.
Supply only aluminium anodised XPM Jali, 24 gauge with 1.4mm average width of aperature complete all as specified and directed.
S&F II nd class Hard Wood plain, solid straight chawkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, completed as specified and directed.
S&F MS flot iron as in hold fast and similar work as specified Gde Fe 410-0 or Fe 310-0.
S&F 35mm thick IInd class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged) fixed to chowkats etc complete all as specified and directed.
S&F 35mm II nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred bends for securing glass etc. size of members of shutters as specified in SSR, Part I, section -8, clause 8.20(a) supplied and fixed to chowkhats.
M&L Flush shutters 30mm, solid core construction, with partical board core and ply wood face panels, commercial type on both sides complete all as specified and directed.
Supply & Fixing in repairs aluminium anodised XPM Jali, 24 gauge with 1.4mm average width of aperature complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed
S&F stainless steel butt hinges 100mm size complete all as specirfied and directed.
S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
S&F 150mm length extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 200mm length aluminium anodised barrel tower bolt of extruded section complete all as specirfied and directed.
S&F aluminium alloy, anodised, sliding door of length 300mm, with hasp and staple (bolt type) and fixing clip of sheets, cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium alloy and fixed. complete all as specirfied and directed.
M&L PCC Block for hold fast and similar work etc 1 : 2 : 4 type B-1(using 20mm graded stone aggregate) complete all as specified and directed.
M&L for preparing surfaces of wood or wood based materials, any description ends of posts, backs of chowkats, etc and treating with tar or coal tar black paint area tarred exc 0.1 sqm but n exc 0.5 sqm each complete all as specified and directed.
M&L for Preparing surfaces of small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats etc area n exsc 0.1 sqm each and treating with tar or coal tar black paint complete all as specified and directed.
M&L for preparation of new wood and wood based surfaes any description, not otherwise described oer 10cm width or girth one coat of pink primer and application of two coats of synthetic enamel paint on new wooden surfaces.
Demolition of brick work or stone / boulder masonry, built in cement or lime mortar including all quoints, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete
M&L Brick work with sub class 'B' old size bricks, built in CM 1 : 6, straight or curved on plan exc 6m mean radius on plan complete all as specified and directed.
M&L connector PVC 450mm long complete all as specified and directed.
Dismantling floor, hearth or wall tiling any description and thickness including cement mortar bedding (but not backing) and removing rubbish off the premises.
M&L PCC 20mm thick type B0, 1 : 2 : 4 (12.5mm graded aggregate) in sub flooring complete all as specified and directed..
M&L non-skid coloured joint free ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry over and including provision of bedding layer 15 mm thick in CM 1 : 4 complete all as specified and directed.
M&L for rendering 10mm thick cement plaster on other than fair faces of bk wall as a backing coat for wall tiles in CM 1:4 complete all as specified and directed.
M&L glazed ceramic jointless coloured tiles in vertical surface 300x200x7mm set and jointed in neat cement slurry over and including provision of bedding layer 10mm thick in CM 1 : 3 complete all as specified and directed.
M&L non-skid coloured joint free ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry over and including provision of bedding layer 15 mm thick in CM 1 : 4 complete all as specified and directed.
M&L for Machine cut Kot stone slab flooring 20-25mm thick over and including provision of screed bed 20mm thick in CM 1 : 6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & mirror polishing complete all as specified and directed.
S&F pvc cabinet mirror in repairs of size 600X450 mm complete all as specfied and directed.
M&L Glass Assembly sheet glass consisting of 5.5mm thick sheet glass 12cm wide with chromium plated bracked guard and railing 60cm long in repairs complete all as specified and directed.
M&L soap dish CP and fixed in repairs.complete all as specified and directed.
Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced complete all as specified .
M&L for cement concrete type C-2, 1:3:6 (40 mm graded aggregate) 75 mm thick as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L plain cement concrete type B2, 1 : 2 : 4, 100mm thick (using 40mm graded aggregate) finished even and fair without using extra cement complete all as specified and directed.
S&F in repairs Tubular towel rail / curtain rod 20mm dia Aluminium anodised & fixed in repairs complete all as specified and directed.
S&F in repairs Aluminium brackets for tubular towel rail 20mm dia complete all as specified and directed.
Taking up or down steel tubing 15mm bore of pipe and connections including cleaning for refixing etc as required complete all as specified and directed..
All as per item no.72 above but 20mm bore of pipe complete all as specified and directed.
M&L tubes medium grade galvanised, with all fittings and fixed complete to walls or ceiling or laid in floors 15mm bore dia.
All as per item no.74 above but 20mm bore dia complete all as specified and directed.
M&L for Wash basin, Vitreous China white (Flat back) 630 x 450mm including brackets,, pinning in ends of brackets or erecting stand including fixing of waste pipe and pillar type etc ( Suppy of pillar tap and waste pipe shall be measured separately) complete all as specified and directed.
Supply only pillar tap cast copper alloy chromium plated fancy type complete all as specified and directed. .
M&L for stop valves 15mm bore dia, cast copper alloy fancy type, chromium plated with long shank and cup concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions in repairs complete all as specified and directed.
All as per item No.78 above but angle cock Chromium plated 15mm bore dia complete all as specified and directed.
M&L bib tap brass 15mm bore dia chromium plated long shank fancy type with curtch or butterfly handle , screwed down, screwed for iron pipes complete in repairs complete all as specified and directed.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
M & L Low density polyethlene (LDPE) pipe of pressure rating 6 Kgf / Sqcm 32mm dia complete all as specified and directed.
M & L Low density polyethlene (LDPE) pipe of pressure rating 6 Kgf / Sqcm 40 mm dia complete all as specified and directed.
Carrying out maintenance of entire sewage system of Erangle (INS TRATA) area by cleaning of sewage line of dia. not exc. 150mm, 200mm and 300mm including blocked manholes by rodding from manholes and well flushing after cleaning and removal of blocked/decomposed sludge/dirt and other materials out side MD land in closed container including removing and re-fixing manhole covers without damaging, cleaning/removal of blockages in trap of kitchen, bath and WC, etc. complete as and when required basis, all as specified and as directed by Engineer-in-Charge. Note :- (a) Sludge/de-composed materials obtained from cleaning shall be removed outside MD land by mechnical sewage cleaning tankers. (b) Rate inclusive of clearing away all grass vegetation, saplings shurbs and trees not exceeding 30 cm girth upto 3 mtrs alround the septic tank and removing rubbish upto a distance of 50 mtrs outside the periphery of the area. (c) One safaiwala and one mazdoor shall be detailed daily for Erangle area for the purpose of rendering the entire sewage system functional through out the contract period. In case of failure compensation will be recovered as specified in respective PS Clause. (d) In case of blockage of sewage system the complaint shall be rectified within three hours from the time of intimation. (e) The rates quoted shall be deemed for attending day to day complaint basis and make functional the entire sewage system for the period of one month at Erangle area.
Cleaning of septic tank including filter bed by bailing out fluid, decomposed materials sludge etc. scraping and washing the wall with fresh water and disposal of decomposed materials, sludge etc. outside MD land for 100 users septic tank complete all as directed by Engineer-in-Charge for the following of septic tanks :- Note 1 - Sludge / de-composed materials obtained from cleaning shall be removed outside MD land by mechnical sewage cleaning tankers. Note 2 - Rate inclusive of clearing away all grass vetetation, saplings shurbs and trees not exceeding 30 cm girth upto 3 mtrs alround the septic tank and removing rubbish upto a distance of 50 mtrs outside the periphery of the area
All as per item No 85 above but for 50 users septic tank complete all as specified and directed.
Dewatering from septic tank by using mechanical pump set and discharging for disposal out side the MD land and spreading required bleaching powder over the area all as specified and directed
Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L RCC 1 : 2 : 4 type B-1 (using 20mm graded aggregate) for cover slab including necessary form work and set in cment mortar 1 : 4, complete all as specified and directed.
M&L form work to sides & soffit of roof beams / top beams rough finished surface of concrete complete all as specified.
Supply and fix TMT bar 10mm dia and over, cut to length, bent to shape required including cranking bending, spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed confirmed to Fe 410-0 complete all as specified and directed.
Supply and fix TMT bar 6 to 8mm dia, cut to length, bent to shape required including cranking bending, spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed confirmed to Fe 410-0 complete all as specified and directed.
Exavating in trenches in Hard / dense soil n. exe 1.5 m wide and n. exe 1.5 m in depth, for foundation etc or for shafts, wells, cess pits, man holes, pier holes etc n exe 10 sq m on plan n exe 1.5 m depth and getting out complete all as specified and directed.
S&F 150mm bore salt glazed stone ware drain pipes laid in trenches and jointed as specfied complete all as specfied and directed.
M&L for concrete in cement concrete 1:3:6 type C2 to bed drain pipes of 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specfied and directed.
Returning, filling in, including spreading, levelling, watering and well raming in layer not exe 25cm complete as specified and directed.
Removing exavated material ourside MD land exe 1.50km but n. exe 5km and depositing where directed complete as specified and directed.
Cutting into existing man holes for connecting new drains of 150mm dia pipe and making good two pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 and finished and reforming benching as required complete all as specified and directed.
M&L PCC (1:2:4) type B1 (20mm graded aggrgate) as in coping, lintel bands , hold fast, string courses, water troughs and the like etc.including weatheing, slightly rounded or chamfered angles, throating, necessary form work complete as specified and directed.
Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced complete all as specified .
M&L bitumastic filling the joint of 10mm wide and 100mm depth comprising of one part of heated bitumen blown grade (85/25) any penetration and 2 part of sand by weight all as specified and directed.
M & L for cement concrete 100mm thick type C1, 1 : 2 : 4 ( using 20mm graded stone aggregate) as in drain, floor etc and finishing even and smooth without using complete all as specified and directed.extra cement.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
Taking down carefully copper/alumunium Sub main wiring from the position and removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
Taking down main switches DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs etc all as specified and directed.
Supply and Fixing in Replcement Of BLDC 5 star Ceiling fan Remote censor Circuit with Suitable existing make only Complete all as specified and directed by the Engr-in-Charge.
Supply Only Of BLDC 5 star Ceiling fan Remote(Including 02 Batteries) with Suitable existing make only Complete all as specified and directed by the Engr-in-Charge.
M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn Completely in and including PVC casing caping fixed on the surfaces of Walls/RCC slab/ ceiling/columns/beams etc with all accessories, fittings, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan point controlled by one one way switch, complete all as specified and directed
All as per item No 108 above but for one 3 pin switch socket 5 Amp single pole one way on same board with other switches including continuous 1.5sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete all as specified and directed.
All as per item No 108 herein above but for one 3 pin switch socket 5 Amp independent complete all as specified and directed.
All as per item No 108 above but for 3 pin switch socket outlet 15 Amp independent with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
All as per item No 108 above but for 3 pin switch socket outlet 15 Amp independent with cable 4.0 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
Supply and fix in replacement of switch modular type 6 amp single pole one way 230 V all as specified and directed.
Supply and fix in replacement of switch modular type 16 amp single pole one way 230 V all as specified and directed.
Supply and fix in replacement of socket outlet multi purpose 5 pin 6 Amp modular type complete all as specified and directed.
Supply and fix in replacement of socket outlet multipurpose 3 pin 16 Amp and 3 pin 6 amp modular type 2 in 1 complete all as specified and directed.
Supply and fixing in replacement of ceiling fan regulator modular type 120 watts all as specified and directed.
Supply and fix in replacement of ceiling rose surface backelite three terminal complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 8/6 Module
Supply & fixing Modular white cover plate with frame 3/4 Module
Supply & fixing modular Plastic Surface PVC box 6/8 Module
Supply & fixing modular Plastic Surface PVC box 3/4 Module
M&L in repairs for Replacement of 3 core 2.5 sqmm PVC insulated electric power FRLS flexible cable (heavy duty) 1100 volts grade complete all as specified and directed.
M&L in repairs for sub main wiring two run of size 4 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 4.0 sqmm PVC insulated copper conductor earth wire in casing caping of suitable size (three run of 4 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed.
Supply and fixing in replacement of old u/s integrated sleek extruded LED Tube Light with acrylic cover 20 watt including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Supply and fixing in replacement of old u/s integrated sleek extruded LED Tube Light with acrylic cover 10 watt including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Supply and fixing in replacement of old u/s LED indoor wall Light with Transperent glass cover 10 watt including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Supply and fixing in replacement of old u/s LED indoor Mirror Light with Opac glass cover 6 watt including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Supply and fixing in replacement of old u/s LED indoor Hanging Light Fixture complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Supply and fixing in replacement of LED lamp with acrylic cover 14 watt Pin type complete all as specified and difected.
Supply and fix MCCB 63 Amps 3 Pole, with breaking capacity 16 KA along with spreader termnals replacement of old unservceable one complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 8 way double door vertical type with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 4 way double door vertical type with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed.
Supply and fix MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SPN 240 volts 40 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix in replacement of old u/s Instant electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 3 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
Supply and fixing in replacement of Exhaust fan Metal Lower(Flip cover Outside) Suitable for Exhaust fan 300 mm size and 450 mm size over the out side surface of Kitchen/Bathroom wall on building Complete all as specified and directed. Note : The rate quoted by the contractor shall arrange the ladder for fixing at any height of floor the building with necessary manpower
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 25 x 4 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 13,160.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
KRISHNA ENGINEERS
M/s Mukesh Engineers
SB CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .