Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Accepted-AOC LOWEST ONE | |
| 2 | L2₹36.5 L+₹1.0 L (2.87%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L2 | Rejected-Finance Being not LOWEST | |
| 3 | L3₹36.9 L+₹1.4 L (4.04%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance Being not LOWEST | |
| 4 | L4₹37.2 L+₹1.7 L (4.86%)Rejected-Finance | L4 | Rejected-Finance Being not LOWEST | |
| 5 | L5₹38.5 L+₹3.0 L (8.39%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L5 | Rejected-Finance Being not LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
21 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY
PROVN OF CERTAIN SANCTIONED WORK UNDER THE AOR OF GE UTILITY ELECTRIC SUPPLY DELHI CANTT 10
2024_MES_638094_1
GE ELEC/D-75/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER NIT
7 documents required · 7 mandatory
₹500
GE UTILITY ELECTRIC SUPPLY
₹99,000
Yes
12 Mar 2024
29 Jan 2024
23 Feb 2024
29 Jan 2024
21 Feb 2024
14 Feb 2024
Amount
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out complete all as specified and directed by the Engg-in-Charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by the Engg-in-Charge.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified and directed by the Engg-in-Charge.
M&L for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc complete all as specified and directed by the Engg-in-Charge. Note : Measurement shall be taken after punning down.
M&L for boring of holes under road/pavement/hard standing including provision of HDPE pipe of 80/100mm dia suitable for 04 Kg/cm working pressure with wall thickness of pipe not less than 6.5 mm complete all as specified and directed by the Engg-in-Charge.
S&F cable end jointing kit for 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed by the Engg-in-Charge.
Supplying, laying, jointing testing and connecting of underground cables, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches, fixed to pole, or passing through pipe complete all as specified and directed by the Engg-in-Charge of following sizes:- Note :- Excavation, earth work , cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
630 Sqmm Single core
185 Sqmm 3.5 core
95 Sq mm 3.5 core.
120 qmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5 core
Taking out old LT 1.1 KV UG cable of size 50 sqmm 3.5 core at site from trench/pole complete all as specified and directed by Engr -in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron 25x4 mm GI strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed by the Engg-in-Charge. Note :- (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode.
M&L for Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron 32x6mm GI strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed by the Engg-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply, installing, testing and commissioning of outdoor type plinth mounted step down transformer, 11 KV/433 Volts. (at no load), Level -II, AC 3 phase 50 Hz, 500 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +5% to -10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. The transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS 1180 (Part-I) : 2014 and shall comprise of the following :- Including the cost of PCC foundation for placing of TRANSFORMER on plinth complete all as specified and as directed by the Engg-in-Charge.
(a) One cable box on HT side (primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out 3 core 120 Sq mm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (b) One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Airrelease valve plug and four nos plain solid cast steel detachable rollers. (f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 32 x 6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 60 KV dielectric strength at 2.5 mm air gap between testing electrodes (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) Unidirectional roller wheel. (n) Other accessories as per manufacturer design. (o) Oil temperature indicator, winding temperature indicator, marshling box single window, double flit buchhloz relay with alarm and trip contact. NOTE : Transformer shall be supplied inclusive of initial oil filling to appropriate level of insulation oil with desired dielectric strength. Cost of Provn of plinth for transformer as per OEM drawing shall be deemed to be included in the cost inserted by the bidders
Supply, installing, testing and commissioning of LT Panel outdoor type with stainless steel (SS 316) cubical enclosure compartmentalized, exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engr-in-charge suitable for SS 316 with Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz, IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley, Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) with the following specifications:- For IHQ CAMP MT (a) Incoming :- (i) ACB 440 Volts 3 phase 4 wire 50 Hz complete with adjestable load protection, no-volt release with microprocesser release EDO neccessory CTs, mertes and cable boxes of rating 630 Amps - 01 Nos 65 KA.. - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 1000 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set (b) Outgoing :-(i) MCCB 4 pole 415 V breaking cap 36 KA , current rating 400 Amps. - 01 Nos (ii) MCCB 4 pole 415 V breaking cap 36 KA , current rating 250 Amps. - 02 Nos (iii) MCCB 4 pole 415 V breaking cap 25KA , current rating 160 Amps. - 01 Nos (iv) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (vi) Indicating Lamps RYB, LED type- 01 set
Supply, installing, testing and commissioning of LT Panel outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). (a) Incoming :- (i) Incomer of the panel having MCCB 440 Volts 3 phase 4 wire 50 Hz complete with adjestable load protection, of rating 400 Amps 36KA - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, , Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 800Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set (b) Outgoing :-(i) MCCB 4 pole, 415 V breaking cap 36 KA, current rating 250 Amps. - 01Nos (ii) MCCB 4 pole, 415 V breaking cap 25 KA, current rating 200 Amps. - 02Nos iii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (v) Indicating Lamps R Y B, LED type - 01 set
M&L for danger notice board of 1.6 mm thick mild steel, vitreous enamelled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20 CM size complete all as specified and directed by the Engg-in-Charge.
Shifting of 160 KVA Transformer from HQ IHQ Camp two pole structure to Shankar Vihar substation by road using the hydra/crane support after removing HT/LT cable connections earth connectionsetc complete all as specified and directed by the Engg-in-Charge.
Removal of old deteriorated 11kv steel pole with all safety precautions by use of Hydra/Crane with rope, safety belts & safety helmets etc complete all as specified and directed by the Engg-in-Charge. (Location:- HQ IHQ CAMP) Note:-Cost of T&P including
Taking out old /unservicable GOD incl making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Taking out old chanel from 2 pole structure incl making good the disturbed surface complete all as specified and directed by Engr-in- Charge.
Taking out old ACSR conductor from 2 pole structure incl making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Supply and lay unreinforced precast concrete cable covers class LV type -1 flat , size 250 x 150 x 40 mm to cover the underground LT Cables compete all as specified and directed by the Engg-in-Charge.
Material & Labour for perimeter fencing of size ( LxWxH) 8m x 5m x 2m (as per site condition) having angle iron post 2 m height for parameter fencing of Transformer / Sub stn including provn of chain link fencing fixed to angle iron/pipe with 25x4 Flat iron incl nut & bolts or subitable clamping arrangement including excavation , earth work , brick work , surface excavation and PCC 1:2:4 type B-1 as in foundation for angle iron posts with Necessary steel gate of angle iron of size 75mm x 75mm x 5mm of size 01 x 2 m including locking arrengment having square bar of size 25mm x 25mm x 3mm including two coat of synthetic enamel paint over a coat of red oxide primer to all steel surfaces complete all as specified and directed by the Engg-in-Charge.
Supply and laying of common burnt bricks as mechanical protection of cables using old size sub class ‘B’ bricks laid dry flat over the cable complete all as specified and directed by the Engg-in-Charge.
M&L for provn of GI Tubes of bore dia 40 mm light grade, galvanised, with all fitting, laid in trenches for protection of cable under road /drain crossings complete all as specified and as directed by the Engg-in-Charge.
Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
Supply, installing, testing and commissioning of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet with 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 450mm x 450mm x 300mm with 4 Nos 250 Amps aluminium bus bar and with 125 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and provn of platform for the Bus bar chamber with PCC 1:4:8 type D-2 using 40 mm graded stone aggregate, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for Bus bar chamber complete all as specified and directed by the Engg-in-Charge. Note:- The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply, installing, testing and commissioning of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet with 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos, 500 Amps aluminium bus bar and with 160 Amp MCCB, 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 using 40 mm graded crushed stone 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 80 mm bore and making good both ends complete all as specified and directed by the Engg-in-Charge.
Supply and laying galvanised iron pipe 50 mm bore light grade fixed to poles with steel clamps or laid under road crossing fixed to wall etc complete all as specified and directed by the Engg-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
MV Engineers And Contractors
M P TYAGI ENGINEERS AND CONTRACTORS
Rajindera Enterprises
Commercial Traders
M/s JAIMAA ASSOCIATES
SB ENTERPRISES
Microsys Controls India
Ridhi engineers and builders
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .