| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹18.3 L+₹1.9 L (11.7%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹18.4 L+₹2.0 L (12.0%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹19.4 L+₹3.0 L (18.5%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹19.6 L+₹3.2 L (19.7%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
16 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JAMMU
GE AF JAMMU
CA NO GE/AFJ-51/20-21 OUTSORCING OF SERVICES FOR MANNING OPERATION AND MAINTENANCE OF EM INSTALLATION AND EXTERNAL ELECTRIC SUPPLY AT AF STN KALUCHAK UNDER GE AF JAMMU
2021_MES_422975_1
CA NO GE/AFJ-51/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KALUCHAK AND JAMMU
AS PER POLICY VOGUE AND AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹48,000
Yes
7 Apr 2021
17 Feb 2021
18 Mar 2021
17 Feb 2021
16 Mar 2021
2 Mar 2021
60 days
Amount
Outsourcing of services for Manning & operation of Electric Supply and water supply Installation (Main Power House, pump house) including operation and maintenence, attending and rectifying breakdown complaint of HT 11 KV and LT 440/220 volts overhead lines/underground cabels, GODs, Switchgears, Panels,Transformers, Voltage Stabilizers, DG Sets and Misc electric supply equipments and alongwith daily routine maintenance and operation of two nos centrifugal water pump set, one chlorinator with booster pump, pipe lines, valves etc. Installation will be run in 2 shifts per day installed in power house and Pump house at Air force Station Kaluchak daily in three shifts including sundays and holidays with 01 (One) Electrician Highly Skilled and One Electrician (Mate) (semi-skilled) all as specified and as directed by Engineer-in-charge. Detail of qualification of tradesman are as under:-
(i) Electrician (Govt approved ITI qualified having minimum two year experience in power distribution and transimission system) / seven year experience in power distribution and transimission system / Govt retired trades man in required trade - 01 No/shift (ii) Helper (Semi skilled) to assist electrician (deployed only under item No 1.00 here-in-before) as per requirement - 01 No/shift (rate of Helper is included in over all rates quoted by the tenderer under item No 1.00 here-in-before) Notes 1:- The personnel employed by the Contractor must have Aadhar number and bank account. The department will install Bio-metric attendance systems at the Air force station Gate to record the attendance of the personnel. Note 2:- (a) Any parts/material required to be replaced or for servicing of DG set etc. during the complaint will be measured and paid for separately under respective item(s). (b) Any minor parts like nuts, bolts, washer, grease etc sundry items like cotton waste to up keep maintenance for by the firm with out any extra cost to the department.
(c) It is an express condition of the contract that payment of wages to tradesmen/workers employed on the subject work shall be made through bank account of individuals only. The contractor shall distribute the payment in first week of every month and will confirm to Engineer-in-Charge by submitting the copy of bank transaction document from bank. The wages paid to the tradesmen/workers shall not be less than minimum wages/fair wages as notified time to time by Govt of India. (d) Contractor shall be carrying out daily /weekly /monthly maintenance check as prescribed makers manual for smooth running of DG Sets. and maintening proper documents all as specified and directed by Engineer-in-Charge. (e) Fuel for running of DG set will be supplied and filled by the department. (f) Log sheet /plant running record book for maintaining records in format as directed by Engineer-in-Charge and supplied by the firm and cost there of shall be deem to be included in the unit rate.
(g) Diesel engine driven Gen Set shall be handed over in operating state on the commencement date through a suitable inventory to be signed by the contractor and the Engineer-in-Charge and returned back to the department in the same state. (h) Contractor shall be provided neccessary protective clothing, hand deisel Pump Set and tools etc,rate shall be deemed to be included in the above quated rates. (j) Contractor will strictly followed the labour act rules (k) Any damage to the department assets handed over for operation due to negligence of firm shall be made food by the firm without any extra cost to the department. (l) The contractor shall engage the requisite manpower in the manner so as to give adequate rest to the working personnel already deployed. (m) Operator Dress and Saftey devices are to be provided by the contractor and strictly will be used by the opertor on duty. No extra payment will be made to the contractor for the same.
M & L for Servicing of DG sets of capacity 75 kVA to 200 kVA including carrying out maintenance and check alongwith following repairs :- (i) Drain out the lubricating oil from sump and refilling after proper cleaning. (ii)Replace Engine Oil filter cartridge with New one. (iii)Replace fuel filter cartridge with New one. (iv)Check tightness of all nuts and bolts. (v) Check adjustment of V belt for driving engine water pump and alternator. (v) Cleaning of fuel tank as required (vi) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engineer-in-Charge. (vii)Testing of DG set after servicing as per Engineer-in-Charge. (viii) Cleaning of air cleaner filter and renew after period two hundred hrs run of DG Set or as recommended by Engineer-in-Charge and contractor shall be responsible to carry out the maint/servecing where require time to time and for which no extra payment shall be permitted. (ix) Any parts required to be replaced during servicing of engine shall be measured and paid for separately.
Note:-(i) Any minor parts such as screws, washers , split pin , circlip, cotton waste, etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted. (ii)The Job shall be carried out after two hundred hrs run of DG Set or as recommended by Engineer-in-Charge and contractor shall be responsible to carry out the maint/servecing where require time to time and for which no extra payment shall be permitted. (iii) Any parts required to be replaced during servicing of engine shall be measured and paid for separately.
Supply Only the following parts suitable for 75 kVA to 200 KVA DG sets: -
Oil filter Cartridge Make: Kirloskar/Greaves/ Cummins/Ruston/Micco/Fleet Guard
Fuel filter Cartridge pre and fine both as required. Kirloskar/Greaves/Cummins/Ruston/Micco/Fleet Guard
Air cleaner filter Cartridge, Make: Kirloskar/Greaves/ Cummins/Ruston/Micco/Fleet Guard
Radiator hose pipe, Make: Kirloskar/ Greaves/ Cummins/ Ruston
Fan belt complete for DG set. Make- Kirloskar/ Greaves/Cummins/Ruston/Fenner
Turbo oil pipe, Make: Kirloskar/ Greaves/Cummins/ Ruston
Fuel pipe heavy duty, Make: Kirloskar/Greaves/ Cummins/ Ruston
Battery terminal of brass heavy duty type as per existing sample
Solenoid Switch, Make: Kirloskar/ Greaves/TVS Lucas
Oil drain pipe heavy duty, Make: Kirloskar/ Greaves/Cummins/ Ruston
Water pump assy, Make: Kirloskar/ Greaves/Cummins/ Ruston
Self startor assy 12 Volt, Make: Kirloskar/Greaves/TVS Lucas/Autolek
Self startor assy 24 volts, Make: Kirloskar/Greaves/TVS Lucas/Autolek
Copper battery lead 3 mtr long 16mm dia multi stranded, Make: Kirloskar/ Greaves/Cummins/ Ruston
DG set rubber coupling for 75/200 KVA, Make: Kirloskar/Greaves/ Cummins/Dunlop
Supply only distilled water, Make: As per the recommendation of Exide/Kochar/Amron
Supply only Coolant Make- Castrol or As per the recommendation of Kirloskar/Greaves/Cummins
Supply only Turbo lubricant oil 15W-40 Make: Castrol or as per the recommendation of Kirloskar/Greaves/ Cummins
Repair/servicing Self startor 12 volts incl replacement of wornout part such as carbon brush, bentex pinion, bushes, carbon brush holder, solinoid and refixng complete set to work of 75 KVA DG sets
Repairng of battery terminals complete including opening connection ,transportation and re-fixing the in orginal position .
Supply and fixing in repairs lead acid battery 12 Volts, 150 Ah Make-Exide/ Amaron/Tata in approved make all as directed by Engineer-in-Charge
M& L for removing bore well column pipes upto 100mm dia with submersible flat cable of any type and dismantling and taking up/down SUBMERSIBLE PUMP & Motor ASSEMBLY of capacity 12.5 Hp, shifting to workshop and removing unserviceable spares, replacing with new spares such impeller, bushes distance bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back and testing for proper function including necessary machining works as required , bringing back and reinstalling into the bore well all as specified and as directed.
M&L for disconnecting and removing the PUMP SET from its foundations/ base frame located at different locations, by disconnecting suction, delivery pipes, pump couplers and electrical connections, taking it to workshop for repair, Dismantling and opening up of PUMP assembly complete, removing worn out Gland, bush, shafts, pump Housing, bearing, Gland Packing, Pin locking set, nuts and bolts, washers etc., and replacing with new parts of same make/model/type including necessary machining works as required, assembling, Balancing and refixing the pump back to its postion after getting repair and making all connections, carry out alignment, and testing for satisfactory function all as specified and as directed for centrifugal pump set of capacity 7.5Hp
Material and Labour for disconnecting and removing the MOTOR of any make/model / type, from pump sets and foundations/ base frame located at different pump houses, by disconnecting electrical connections and pump couplers, taking it to workshop for repair, dismantling stator and rotor assembly, removing burnt out winding wires complete, rewinding the stator with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding, drying up by heating , assembling back the stator and rotor including replacement of nuts, bolts, studs, Gasket, packing, locking pin, terminal blocks, and terminal bolts and nuts and misc accessories & hardware required for making motor functional, both end bearings (labour only) with same size/make complete for 3Ph, 415V, 7.5Hp motors all as specified and as directed. Note: 1. Bearing shall be measured and paid saperately.
Supply only antifriction heavy duty ball bearings suitable for 7.5Hp pump/Motor
S & F in replacement Single Phase preventor relay SPPR type Sz5 (6 Wire), 415V, cat No. CS94824DOOO Make : L&T or equivalent in Seimens/Havells
Taking down old u/s push button and S & F Illuminated Push Button Projecting Head complete all as specified and directed in RED/GREEN in color, 240V AC, Cat No EG03PDL, Make: L&T/HPL with taking down old u/s push button of any type
Taking down old u/s phase indication lamp and S & F LED Indication lamp for LT Panel board RED/YELLO/BLUE, Surface Mounted Device LED technology Low Power consumption < 0.6W Low Voltage Glow Protection (LVGP) Cat No: SIL 240A-240V AC Make: L&T or HPL/Havells
Supply, laying, connecting and testing Submersible flat cable 3 core 10 Sqmm PVC insulated and PVC sheatehed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
Supply and fix cam operated rotary switches 32A with 90⁰ ON-OFF operation and complete rotation of type . Cat No.61197 of Make: L&T or equivalent of Simens/Standard
M&L for Painting of pump sets & motor assembly of capacity 5Hp to 15Hp located at various installations comprising electric Motor , pump , base frame, suction and delivery pipe lines inside & outside of pump house, valves any type and size up to 100 mm dia withTwo coat of synthetic enamel paint of approved colour including scrubbing / cleaning all metalic surfaces before painting and writing SM/MES No. etc, all as specified and as directed.
M & L for Painting with two coat of synthetic enamel paint for pipes any description, n. exc 60 cm girth including holder bats, distance pieces, etc. (length measured over bends, branches etc.)
M & L for dewatering and cleaning the RCC Underground/semi under ground sump at AF Station Kaluchak by cleaning the complete inner surfces by rubbing / scrapping by wire brush to remove the sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the out side of the tank with synthetic enamel paint with letter size 20 cm high in white colour , over a black background of size 100x60 cm all as specified and directed of capacity up to 30,000 GLN capacity
M & L for carry out water quality anyalysis for bacterial, chemical and biological analysis including for collection of water samples from the pump house or from location as specified by Engineer In Charge and testing from govt approved testing laboratory, submitting of reprort for minimum following parameters (a) Turbudity (NTU) (b) pH (c) Total Hardness as CsCO2 (mg/l) (d) Sulphate as SO2 (mg/l) (e) Iron as Fe (mg/l) (f) Magnesium as Mg (mg/l) (g) E-Coli or thermotolerant coliform bacteria (h) Remarks of Govt water testing lab Note: Recovery will be carried out at twice the quoted rate if water testing not carried out as specified.
Excavation in trenches in exc 1.5 m width and n. exc 1.5 m depth and getting out inHard/Dense soil for laying of water pipe line etc. complete all as specified and as directed
Returning, filling in (Soils) including spreading levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Removing excavated material (soil) n. exc 50 metre and depositing where directed at a level n. exc 1.5 metre above the starting point complete all as specified and as directed by Engr-in- charge
Supply and laying in trenches Galvanised steel (Gl) tubing 'Medium grade' with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) with cutting, screwing, making forged bends on piping as required. insertion of Connectors where required or directed. including cutting through walls, floors, etc. and their making good all as specified and as directed for including taking down old u/s pipe for following size of pipes : (Note : Earthwork shall be measured and paid saperately under relavent Item)
15mm bore dia
20mm bore dia
25mm bore dia
40mm bore dia
50mm bore dia
80mm bore dia
Supply and install CI foot valve of size 80mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
Taking down carefully unsv copper/aluminium point wiring light/fan/socket or power complete and including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) and removing material from site
Material and labour for point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated unsheathed cable with proper colour coding drawn in existing conduit and FRLS PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 cm deep & 2.8 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following.
(a) One light /fan/ call bell point controlled by one switch
(b) One 3/5 pin socket outlet 5 amp controlled by one 5 amp switch on the independent board
(c) One 3/5 pin socket outlet 5 Amps on same board controlled by one 5 amp switch
NOTE for Item 28:- Cutting chases in wall for removing old conduit shall be approved & have to shown to the Engr-in-Charge by the contractor before laying new conduit and wiring. 2. Wiring shall be done by contractor with colour coding. 3. Earth wire shall be in green colour. 4. wiring shall be carried out under repair work against the complaints received from the users and no bulk site will be issued to the contractor.
All as per item No 28.00 here-in-before but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board for 15A socket point.
Supply and fixing PVC concealed conduit not less than 20mm dia will all accessories complete all as specified and as direced by Engineeer-in-Charge NOTE: Cutting chases in wall for removing old conduit shall be approved & have to shown to the Engr-in-Charge by the contractor before laying new conduit and wiring.
M & L LED slim ceiling light fitting with extruded aliminium housing and milky diffuser 36 W 2'x2' slim panel, 610x610 mm recess/surface/ suspended mounting and testing complete including dismantling and taking down old fitting of any type all as specified and as directed by Engr-in-charge Cat part No- LTCRSLM36WATT2X2 of C&S/Havells/Crompton
Supply only the following items to be fixed against ser item No. 1.00 here in before:- Note: Rate for taking down old unserviceable material and fixing of new items shall be deemed to be included under item No 1.00 here-in-before.
Switch piano flush type single pole one way 5 Amps complete
Bell push piano flush button single pole one way 5 Amps complete
Ding-dong type electric belll AC 230 Volts single pole complete of make Anchor/Philips
Switch, socket combination outlet multipurpose, 2 in 1, 3 pin, 5 Amp flush type complete
Switch socket combination multipurpose 3 pin 5 Amp and 15 Amps, flush type complete
Socket outlet multipurpose 2 in 1, 3 pin, 5 Amp flush type complete
Socket outlet multipurpose 2 in 1, 3 pin, 5 pin and 15 Amps, flush type complete
Stepped type electronic fan regulator flush type
Ceiling roses 3 phase /PVC/ Polycarbonate isolated body
Indoor decoraticve LED Battens -T8 tube light fitting 20 W,4 fit long white with PVC extruded batten complete in all respect incliding 20 W retrofit tube and taking out old complete all as specified and directed by Engineer-in-Charge. Make: Cat part No- LTDCO1220E LED/WD of C&S or equal approved in Philips/Bajaj/ Havells/Crompton
DB SPN 8 Way 240 volts double door with 200 amps rated bus bar. rated bus bar, SPN, Make: Cat part No 507611 of Legrand (DX³) or equal approved in Siemens (8GB32)/Schneider (Acti 9)
Supply and fix Cable 1100 volts grade heavy duty 10 sq mm flat/round twin core cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed taking out old for service connection complete all as specified and directed by the Engineer-in-charge.
Supply and fix, taking down old MCB TPN 415 Volts, C curve, 40 to 63 Amps, 10 kA, Make: Cat part No 408700 to 408702 of Legrand (DX³) or equal approved in Siemens (Betagard-5SL4)/Schneider (Acti 9)
Supply and fix, taking down old MCB SPN 240 Volts, C curve, 32 to 63 Amps, 10 kA, Make: Cat part No 408636 to 408639 of Legrand (DX³) or equal approved in Siemens (Betagard-5SL4)/Schneider (Acti 9)
Supply and fix, taking down old MCB SP, C curve, 6 ot 32 Amps, 240 Volts, 10 kA, Make: Cat part No 408587 to 408595 of Legrand (DX³) or equal approved in Siemens (Betagard-5SL4)/Schneider (Acti 9)
ISI mark aluminium thimbles suitable for under ground LT cables of sizes 16 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same.
ISI mark aluminium thimbles suitable for under ground LT cables of sizes 25 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same.
ISI mark aluminium thimbles suitable for under ground LT cables of sizes 185 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same.
Supply only Tinned copper fuse wire rating 20 Amp as per sample approved by Engr-in-charge.
Cable jointing kit for 11 KV (Earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 sqmm to 95 sq mm complete all as spd and directed. Make - Denson/ M-Seal
Supply and fixing expulsion fuse single pole up to 25 Amp, 11000 Volts grade complete all as specified and as directed. Make - Jaipuria/Rashtria/L&T
Supply and fix, taking down old Indus series Powder coated pressure die cast aliminium compact high power LED street light fittings with heat resistant toughned glass with lens having 45 Watt with lens complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make: Cat part No- LTESS 18x2.5 HP LED/LS of C&S or equal approved in Philips /Bajaj/ Havells Note: Name of contractor and CA number shall be provided on Street light fitting duly printed on Aluminium sheet
Supply and fix, taking down old Indus series Powder coated pressure die cast aliminium compact high power LED street light fittings with heat resistant toughned glass with lens having 30 Watt with lens complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make: Cat part No- LTESS 12x2.5 HP LED/LS of C&S or equal approved in Philips /Bajaj/Havells Note: Name of contractor and CA number shall be provided on Street light fitting duly printed on Aluminium sheet
Supply and fix, taking down old High power LED flood lights fittings with pressure die cast aluinuim housing complete with all accessoies IP 65,120 watt , complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make: Cat part No- LTEFI120WHPLED of C&S or equal approved in Philips /Bajaj/ Havells
Supply and fix, taking down old ISI mark MCCB 4 pole, 415 volts, thermal release range 100 amps having breaking capacity of 36 kA complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make - Cat part No 420095 of Legrand (DPX³) or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and fix, taking down old ISI mark MCCB 4 pole, 415 volts, thermal release range 200 amps having breaking capacity of 36 kA complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make -Cat part No 420248 of Legrand (DPX³) or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and fix, taking down old ISI mark MCCB 4 pole, 415 volts, thermal release range 250 amps having breaking capacity of 50 kA complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make -Cat part No 420279 of Legrand (DPX³) or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and fix, taking down old UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make- Gloster/polycab/Havells
Supply and fix, taking down old UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 2 core complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make- Gloster/polycab/Havells
Material and labour for maint/repair of existing feeder piller Box/LT Panel, bus bar, hinge, handle, locking arrangment, foundation, thimble, loose connection including welding to door ,legs,back door etc,complete all as specified and directed by Engineer-in-Charge
Material and labour for repair to existing LED street light 30/ 45 watt of any make including replacement of driver, LED strips and other allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge
Repair/maintenacne of lifts including carrying out periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/ maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen
button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for illuminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light and minor repair of cabin fan , ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting of Gear motor, all MS channels and Control panels using spray gun complete, dewatering of lift wells in case of any emergency arise all as directed by Engineer-in-Charge. for the 8Passanger Lift operating for G+4 floors at SRE Bldg 23Wing AF Jammu
Note :- (a) The above service shall be made on monthly basis and as and when any breakdown arise (b) The Contractor shall be porvide authorised service personnel of Johnson company as and when required in case of any emergency occured at any time included odd hrs/sunday/Holiday and cost to this effect shall be deemed to included in quoted rates. (e) The Contractor shall visit the site before quoting the tender.
Supply only the following item of lift for making the lift serviceable completely to the entire satisfaction of the Engineer-in-Charge (Note: The fixing of these items including taking out unserviceable items shall be measured under ser item No 45.00 here-in-before): -
Door beading (as per sample)
Car push button(ISI Marked) (as per sample),
Car light fittings (as per sample), Make: Havells/Bajaj/C&S
Buzzer (as per sample)
Alram Device (as per sample)
Back up batteries 12V 18 AH complete and suitable for lift, Make:Amron/Exide
Cutting wild grasses,bushes,creepers,unwanted vegetations, etc. from surrounding power house/pump house/transfarmer/poles/stays including cleaning cripper climbed on poles as and when directed and removing the spoil and deposit where directed (size of cutting 90x90 cm around pole/stay) entire satisfaction of Engnr-in-Charge complete all as specified and directed .
Material and labour for carrying out annual maintenance of UV based water purifier make Livpure/ Aquafit by replacement of pre filter candle sleek and carbon block twice in a year and servicing twice after regular intervals, including the replacement of circuit board and any other part as required at site to make the Livpure/ Aquafit functional throughout the year.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
M/S MANJIT SINGH AND SONS
Harsh Electricals
asian traders
VIDHATA ELECTRICALS
bamral builder
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .