Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.5 L+₹57,412.90 (1.92%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.4 L+₹1.5 L (4.90%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹33.4 L+₹3.5 L (11.7%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹34.1 L+₹4.1 L (13.8%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Feb 2022, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
REPAIR/REPLACEMENT TO LT OH LINE, UNDERGROUND CABLE, LT PANELS, STREET LIGHTS AND ALLIED WORKS AT OLD CANTT AND FORT CANTT UNDER GE (EAST) ALLAHABAD
2022_MES_500728_1
8533/E8
Open Tender
Civil Works
Item Rate
270 days
Allahabad
As PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹98,000
Yes
29 Apr 2022
10 Jan 2022
10 Feb 2022
10 Jan 2022
8 Feb 2022
25 Jan 2022
10 Jan 2022 - 17 Jan 2022
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft / loose soil including trimming of bottom surface trench to required level or slope for laying of cable etc., complete all as specified and directed.
Returning, filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft / loose soil, complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
Sand cushioning with dry local river sand for cable protecting under ground cable in trenches and consolidated, complete all as specified and directed. NOTE:- Punned thickness shall only be measured and paid.
Sub class ‘B’ common burnt clay bricks, old size, designated '75', laid dry, flat with width of trench equal to length of bricks, laid as protection over the cable, complete all as specified and directed.
Steel tubing, light grade, ISI marked, galvanised including short lengths, laid in trenches / fixed to walls and poles / ceilings or laid in floors or laid under road crossings as cable protection, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 40 mm bore of pipe, including taking down unserviceable pipe, complete all as specified and directed. NOTE:- Excavation and earthwork shall be measured and paid separately under respective items of this Schedule.
Steel tubing, light grade, ISI marked, galvanised including short lengths, laid in trenches / fixed to walls and poles / ceilings or laid in floors or laid under road crossings as cable protection, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 50 mm bore of pipe, including taking down unserviceable pipe, complete all as specified and directed. NOTE:- Excavation and earthwork shall be measured and paid separately under respective items of this Schedule.
Steel tubing, light grade, ISI marked, galvanised including short lengths, laid in trenches / fixed to walls and poles / ceilings or laid in floors or laid under road crossings as cable protection, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 80 mm bore of pipe, including taking down unserviceable pipe, complete all as specified and directed. NOTE:- Eexcavation and earthwork shall be measured and paid separately under respective items of this Schedule.
Supplying, laying, jointing, commissioning and testing of 16 sq.mm, 4 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 25 sq.mm, 4 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 35 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 50 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 70 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 95 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 120 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 150 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 185 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 240 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Earthing with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of 32mm x 6mm size by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:2:4) type B-1 earth chamber, 40mm thick precast RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor and protection pipe beyond 7.5metre shall be measured and paid under respective item of this Schedule.
Earthing with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to copper earth strip of 20mm x 3mm size by means of bolts, nuts, washers of galvanised iron or steel, copper earth strip shall be protected by 40mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:2:4) type B-1 earth chamber, 40mm thick precast RCC cover (1:2:4) type B1 mix with 6mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor and protection pipe beyond 7.5metre shall be measured and paid under respective item of this Schedule.
Air termination, single pointed aluminium rod 12mm dia and 300mm long, fixed in repair, complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw, complete all as specified and directed.
Copper strip of size 20mm x 3.15mm fixed on wall / trench with saddles screw from earth point (beyond 7.5metre to testing point), fixed in repair, complete all as specified and directed.
Aluminium strip of size 25mm x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground upto test point (on surrounding of air termination upto test point), fixed in repair, complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or uried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32mm x 6mm galvanised iron or steel strip, fixed in repair, complete all as specified and directed.
MCCB 4 pole, 400 Amp capacity, 36 kA breaking capacity in suitable sheet metal enclosure including connecting existing cable, fixed in repair, complete all as specified and directed. MAKE:- HAVELLS / INDO-ASIAN / L&T / LEGRAND / ABB
MCCB 4 pole, 250 Amp capacity, 36 kA breaking capacity in suitable sheet metal enclosure including connecting existing cable, fixed in repair, complete all as specified and directed. MAKE:- HAVELLS / INDO-ASIAN / L&T / LEGRAND / ABB
MCCB 4 pole, 160 Amp capacity, 25 kA breaking capacity in suitable sheet metal enclosure including connecting existing cable, fixed in repair, complete all as specified and directed. MAKE:- HAVELLS / INDO-ASIAN / L&T / LEGRAND / ABB
MCCB 4 pole, 100 Amp capacity, 25 kA breaking capacity in suitable sheet metal enclosure including connecting existing cable, fixed in repair, complete all as specified and directed. MAKE:- HAVELLS / INDO-ASIAN / L&T / LEGRAND / ABB
MCCB 4 pole, 63 Amp capacity, 25 kA breaking capacity in suitable sheet metal enclosure including connecting existing cable, fixed in repair, complete all as specified and directed. MAKE:- HAVELLS / INDO-ASIAN / L&T / LEGRAND / ABB
Drilling holes under the road with out damaging existing road / path for laying LT UG cable, complete all as specified and directed.
Painting of 9.00 metre steel pole with cross arms and clamp of any length and shape for overhead line / street light pole by taking necessary shut down with prior permission, and painting with one coat of aluminium paint including preparation of the existing surface including marking serial number of pole in a 15cm dia yellow circle and marking three black and two yellow bands of 10 cm heigh using fluorescent paint, from coping of pole to 1.5m height on pole including painting of coping with white wash with safety precautions and all disconnected electrical connections are re-connected and to restore the position as existing before taking shut down, complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking down of exsiting cross arms, complete all as specified and directed.
Dismantling / disconnecting existing unserviceable ACSR conductor on overhead lines on LT poles, of any size, complete all as specified and directed.
ACSR conductor including jointing with and including provision of aluminium binding wire 14 SWG and stretching, complete all as specified and directed. NOTE:- For payment purpose, weight of conductor shall only be considered. MAKE:- INDIAN ALUMINIUM CO. / BHARAT CONDUCTOR / ALUMINIUM IND
Labour only for reuse of old serviceable ACSR conductor including jointing with and including provision of aluminium binding wire 14 SWG and stretching, complete all as specified and directed. NOTE:- ACSR conductor retrieved from disamantling all as per Sl. No. 34.00 here-in-before shall be re-used in this item
Galvanized steel wire 4mm dia as continous earth wire for guarding and cradles including binding as required with and provision of binding wire of GI wire 14 SWG, complete all as specified and dirtected.
Stay assembly consisting of galvanised stay strand 7/2.24mm, stay bow of 14 mm dia, stay rod 16 mm dia 180 cm long with loop insulators, stay plate 230 mm x 230 mm x 6 mm with and including provision of plain cement concrete foundation 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate ) complete with provision of stay clamps, bolts and nuts, fixed in repair, complete all as specified and directe. NOTE:- The quoted rate shall deemed to be inclusive of the following provisions: (a) Excavation and earth work for stay foundation in soft / loose soil, RFR, disposal of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre from the starting point as directed. (b) PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in embedding blocks etc., all as specified.
Shackle type porcelain viterous white brown or green insulator of working pressure 1100 Volt and of size 100mm height and 115mm dia including provision of GI steel straps of section 38mm x 5mm size, 20mm dia bolt and nuts, washers, fixed in repairs, complete all as specified and directed
Disconnecting, taking out and relaying in trenches after rectification of the defect / fault or fixing in wall or poles, LT under ground cables of any description after testing continuity to complete satisfaction including provision of neccesary lugs ,glands, excavation and earthwork ,sand cushioning and cable protection like bricks, GI pipe etc., complete all as specified and directed.
Supply and drawing copper conductor cable 2.5 sq.mm two single core with 2.5 sq.mm earth wire for connection from junction box to street light fitting with and including provisin of 2 Nos hole in the existing steel tubular pole including taking down existing copper conductor of any size and any type, complete all as specified and directed. NOTE:- Two run of cable (one for phase and one for neutral) and one run for earth shall be measured as one unit length.
Painting of LT panel of any capacity and any size, on both internal and external sides of panel doors, pedestal, busbar chamber duly covering measuring instruments, indicators etc. with one coat of synthetic enamel paint after removing dust, dirt and including preparation of the surfaces for painting including welding of the broken parts of panel, hinges and including painting of sign, writing incommer and feeder details using fluorescent paint, complete all as specified and directed.
Disconnection all incoming and outgoing cables from LT panels and refreshing all connections by replacement of carbonised lugs including taking out sand from the trenches and refilling fresh sand for cushioning of the cables and reconnecting the cables to the busbars with new GI nut, bolts after wrapping the busbars with PVC tape as per standard colour code, complete all as specified and directed. NOTE:- Cost of lugs, glands, PVC tape and GI nut, bolts and sand cushioning (punned thickness of 180mm) shall deemed to be included in the quoted rate of this item.
Taking out old and unserviceable / rusted steel tubular pole and Provision of new Steel tubular pole, conforming to 411-SP 31 (9.0m long pole), complete with cast iron base plate, pole cap, mild steel bolt, nuts and screws, complete all as specified and directed. The quoted rate shall deemed to be inclusive of the following provisions :- (a) Excavation in trenches not exceeding 1.5 metre wide and 1.57 metre deep for pole foundation and getting out in soft / loose soil, returning filling in the excavated of soil after fixing the pole, in foundations and ramming earth around in layers not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 metre, complete all as specified and directed. (b) PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) in foundations, 900mm x 600mm cross section and planting depth 1.5 metre for concrete encasing the pole upto GL, complete all as specified and directed. (c) PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block / collar above GL 500mm high and 450mm dia, complete all as specified and directed. (d) Painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block / concrete collar with two coat of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5metre above plinth block. (e) Writing letters or figures (Block Roman, Italic or Indian) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole, complete all as specified and directed. NOTE :- Manufacture's test certificate of the pole shall be produced before execution work. MAKE:- National tubing Co., Kanpur / BCW Kanpur / M/s Sohan Lal & Sons / United Engineers, Kanpur.
Cutting, trimming and vending tree branches along over head lines (LT / HT) after arranging electrical shut down including taking all precautions while working on lines, with and including provision of suitable T&P by the contractor, complete all as specified and directed. NOTE:- After taking shut down to excute the work, minimum one skilled electrician and four mazdoor for 8 hrs per day shall be deployed on the work by the contractor. The quoted rate shall deemed to be inclusive of the above provisions and no extra what-so-ever shall be entertained at later stage.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 200mm x 150mm size, fixed in repairs, complete all as specified and directed.
Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, fixed in repair, complete all as specified and directed.
L.T. lightning arresters for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 Volt, fixed in repair, complete all as specified and directed.
MCCB 4 pole, 630 Amp capacity, 36 kA breaking capacity in suitable sheet metal enclosure including connecting existing cable, fixed in repair, complete all as specified and directed. MAKE:- HAVELLS / INDO-ASIAN / L&T / LEGRAND / ABB
Supply and laying or fixing or passing through pipe, 1100 Volt grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, 2-core 10 sq. mm nominal cross section in service connections, fixed in repair, complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 Volt grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, 2-core 16 sq. mm nominal cross section in service connections, fixed in repair, complete all as specified and directed.
Replacement of existing mild steel stand of battery bank system with suitable size of wooden stand made out of second class hard wood, including providing adequate support, including provision of painting of two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Power invertor suitable for output 600 Vh (Sine-wave), 230 Volt AC with all standard technical features including taking out unserviceable inverter of any type, complete all as specified and directed. MAKE:- MAHINDRA / LOGITECH / LUMINOUS
Inverter battery, tubular type, maintainance free, 12 Volt, 180Ah including taking down unserviceable battery of any type, complete all as specified and as directed. MAKE:- EXIDE / AMARON / LUMINOUS
Maintenance / servicing of solar water heater 100 / 200 litre per day capacity by cleaning pipes and tubes, checking of solar panels and SV unit ,checking of electrical backup system, control wiring, complete all as specified and directed.
Maintenance / servicing of earth pits at substation and of lightining protection by cleaning in and around the chamber, repair / replacement of MS chamber cover / PCC cover slabs, removing wild growth weeds from the area around earth chamber, provision of salt water in to earth pits, repair / replacement of funnel, checking of earth contiunity connection, checking and recording of earth resistance results and painting the results with date of testing etc., on the chamber, complete all as specified and directed.
Servicing / maintenance / repair of AMF panel by checking and replacing defective relays, timers, single phase preventer, panel control wiring with suitable size of fire retardant copper wire, power contactor etc., in AMF panel with new ones, complete all as specified and directed.
Taking down of unserviceable Automatic power factor correction panel of capacity 125 / 100 / 75 / 50 / 25 kVA from existing active circuit and inspection for defects and replacement of the defective / burnt out parts from APFC panel, complete servicing of Automatic power factor correction panel including connection and testing, complete all as speciifed and directed. NOTE:- The quoted rate shall deemed to be inclusive of charges of supervisor, electrician, helper and testing for functionality of all parameters of APFC panel complete.
Relay NAACX-3P-125APFC, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
Relay NAACX-3P-100APFC, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
Relay NAACX-3P-75APFC, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
Relay NAACX-3P-50APFC, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
Relay NAACX-3P-25APFC, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
CTs for sensing 220 / 5 class-I, 15VA including taking out unserviceable one, complete all as specified and directed.
Copper wire 2.5 sq.mm for sensing CTs, complete all as specified and directed.
Heavy duty contactor, including taking out unserviceable one, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
MCB TP, 63 Amps, 10kA breaking capacity, 'C' curve, including taking out unserviceable one, complete all as specified and directed. MAKE:- HAVELLS / L&T / ABB / INDO-ASIAN
Heavy duty Power - 9 capacitors, 25 kVAR, including taking out unserviceable one, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
Heavy duty Power - 9 capacitors, 20 kVAR, including taking out unserviceable one, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
Heavy duty Power - 9 capacitors, 15 kVAR, including taking out unserviceable one, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
Heavy duty Power - 9 capacitors, 10 kVAR, including taking out unserviceable one, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
Heavy duty Power - 9 capacitors, 5 kVAR, including taking out unserviceable one, complete all as specified and directed. MAKE:- NEPTUNE or techno-commercially equivalent make as mentioned in list of manufacturers here-in-before.
MCB, TP, 6 Amp for relay including taking out unserviceable one, complete all as specified and directed. MAKE:- HAVELLS / L&T / ABB / INDO-ASIAN
Taking down unserviceable servo voltage stabilizer of capacity 100 kVA, inspection for defects and transporting to workshop for repair, complete all as specified and directed. NOTE:- The quoted rate shall deemed to include for cost of labour element ie., for electrician, helper for loading and unloading of stabilizer, to-and-fro cost of vehicle for transportation.
Automatic control power card of IC control based, complete all as specified and directed.
Driver Transformer of 240V 50Hz, A.C / 24V D.C of one Amp with continuous supply, heavy duty, copper conductor super-enemalled winding, suitable to match the control card, complete all as specified and directed.
Potential meter 10W, 5kilo ohms, complete all as specified and directed.
Synthetic line separators of LT OH lines with nuts, bolts and washers, straight type, horizontal configuration fixed at a point as directed and suitable for three phase 5 wire LT lines, complete all as specified and directed.
Servicing of LT ACB unit by disconnecting, opening up the switch, cleaning thoroughly all the inner parts, lubricating the moving parts, replacing unserviceable spares as required for smooth operation of switch gear, including testing, complete all as specified and directed. NOTE:- (i) Spare parts of existing make shall be measured separately as 'Supply only' under respective items of this Schedule. (ii) Quoted rate shall deemed to be inclusive of cleaning material and lubricants, as required.
Supply only Closing and opening release for Air Circuit Breakers, complete all as specified and directed.
Supply only Under voltage release for Air Circuit Breakers, complete all as specified and directed.
Supply only Micro switch for S / C trip indication release for Air Circuit Breakers, complete all as specified and directed.
Supply only Special sliding contact for electrical position indication release for Air Circuit Brakers, complete all as specified and directed.
Supply only Earth fault relay 3 phase 3 wire release for Air Circuit Breakers, complete all as specified and directed.
Supply only Escutcheon cover for Air Circuit Breakers, complete all as specified and directed.
Supply only Aux contact block 4 NO + 4 NC for Air Circuit Breakers, complete all as specified and directed.
Supply only Fixed + moving sliding contact - 2 Nos for Air Circuit Breakers, complete all as specified and directed.
Supply only Shutter assembly - 3 pole for Air Circuit Breakers, complete all as specified and directed.
Supply only Arc chute - set of three for Air Circuit Breakers, complete all as specified and directed.
Supply only Fixed arcing contacts - 3 phase for Air Circuit Breakers, complete all as specified and directed.
Supply only Moving arcing contacts - 3 phase for Air Circuit Breakers, complete all as specified and directed.
Supply only Floating isolating contacts - set of 3 for Air Circuit Breakers, complete all as specified and directed.
Supply only CTs for thermal over load relay - 3 Nos, 630 A for Air Circuit Breakers, complete all as specified and directed.
Supply only CTs for STU release - 3 Nos, 630 A for Air Circuit Breakers, complete all as specified and directed.
Supply only Instantaneous U/V release for Air Circuit Breakers, complete all as specified and directed.
Supply only Time delay unit for U/V release for Air Circuit Breakers, complete all as specified and directed.
Supply only Shunt trip coil for Air Circuit Breakers, complete all as specified and directed.
Supply only Additional shunt trip coil for Air Circuit Breakers, complete all as specified and directed.
Supply only Closing coil for Air Circuit Breakers, complete all as specified and directed.
Laying Only Sub class ‘B’ common burnt clay bricks, old size, designated '75', laid dry, flat with width of trench equal to length of bricks as protection over the cable, complete all as specified and directed.
Cutting of existing cement concrete flooring and fixing of GI pipe in trenches for passing of cable and making good the disturbed surface to match with the existing, complete all as specified and directed. NOTE:- GI pipe shall be measured and paid under respective item of this Schedule.
Supplying, laying, jointing, commissioning and testing of 25 sq.mm, 3.5 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Supplying, laying, jointing, commissioning and testing of 10 sq.mm, 2 core XLPE cable insulated and screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable, complete all as specified and directed. NOTE:- Excavation and earth work, sand cushioning and brick protection shall be measured and paid separately under respective items of BoQ. MAKE:- FINOLEX / PLAZA / HAVELLS / KALINGA PREMIUM
Dismantling insulators any type, any size, complete all as specified and directed.
Dismantling stay assembly, complete all as specified and directed. NOTE:- Excavation and earthwork for taking out the embedded portion of stay assembly shall be measured and paid separately under respective items of this Schedule.
Disc type insulator, porcelain, vitreous, white, brown or green,145 mm high and 255mm dia ball and socket type single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade, complete all as specified and directed. MAKE:- Southern insulator / Reychem / Birla 3M / Jaipuria
Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100 mm height and 65 mm dia suitable for working pressure 1100 volts grade, complete all as specified and directed. MAKE:- Southern insulator / Reychem / Birla 3M / Jaipuria
GI bracket for street light fittings fabricated with GI tubing 40 mm dia 'medium grade' 1.5 metre long and bending to angle as required and of 1200mm length, with and including provision of mild steel clamp fabricated with mild steel flat iron 50mm x 6 mm with nut, bolts and washers suitable for fixing of GI bracket on PCC / steel poles fixed in repair, complete all as specified and directed.
Painting of 11.00 metre steel pole with cross arms and clamp of any length and shape for overhead line / street light pole by taking necessary shut down with prior permission, and painting with one coat of aluminium paint including preparation of the existing surface including marking serial number of pole in a 15cm dia yellow circle and marking three black and two yellow bands of 10 cm heigh using fluorescent paint, from coping of pole to 1.5m height on pole including painting of coping with white wash with safety precautions and all disconnected electrical connections are re-connected and to restore the position as existing before taking shut down, complete all as specified and directed.
Three pole power contactor, ML-3 type, range of AC-1 rating 45 Amp , AC-3 rating 40 Amp, Aux.Contacts (2NO + 2NC), 110V, 220V, 240V and 415V , 50Hz, fixed in repair, complete all as specified and directed. MAKE:- L&T Cat Part No. SS90721 / Legrand Cat No- 416134
Three pole power contactor, ML-4 type, range of AC-1 rating 100 Amp , AC-3 rating 70 Amp, Aux.Contacts (2NO + 2NC), 110V, 220V, 240V and 415V , 50Hz, fixed in repair, complete all as specified and directed. MAKE:- L&T Cat Part No. SS90910 / Legrand Cat No- 416184
Aluminium thimbles, cables lugs for cables of size 50 sq.mm including necessary crimping with crimping tool, fixed in repair, complete all as specified and directed.
Aluminium thimbles, cables lugs for cables of size 70 sq.mm including necessary crimping with crimping tool, fixed in repair, complete all as specified and directed.
Aluminium thimbles, cables lugs for cables of size 95 sq.mm to 120 sq.mm including necessary crimping with crimping tool, fixed in repair, complete all as specified and directed.
Cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material, heat shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm, Indoor / Outdoor type, complete all as specified and directed.
Cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material, heat shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 150 sqmm, Indoor / Outdoor type, complete all as specified and directed.
Taking down existing unserviceable security lights / LED street light / flood light / HPSV fittings, any type and refixing after repairs, complete all as specified and directed.
LED Driver for 72 / 75 Watts perimeter LED Security light fittings, fixed in replacement, complete all as specified and directed. MAKE:- Crompton 'driver' Cat Part No.X075C070V107FNY1B0 or techno- commercially equivalent in Bajaj / Havells
LED Driver for 90 Watts perimeter LED Security light fittings, fixed in replacement, complete all as specified and directed. MAKE:- Bajaj 'driver' Cat Part No. BGD 36 240 5Y or techno- commercially equivalent in Havells / Crompton
LED Driver for 120 Watts perimeter LED Security light fittings, fixed in replacement, complete all as specified and directed. MAKE:- Bajaj 'driver' Cat Part No. BGD 40 295 5Y or techno- commercially equivalent in Havells / Crompton
Energy efficient LED flood light fittings 120 watts presure diecast aluminium housing and IP 66, fixed in repair, complete all as specified and directed. MAKE:- Crompton Cat Part No: LSTN-120-CDL-A / Cat Part No- LFLN-120-CDL60 of Philips or techno- commercially equivalent model in Bajaj
New generation energy saving and environmental friendly long life versatile pressure die-cast aluminium IP 66 LED street light fitting 90 watts on existing street light pole, fixed in repair, complete all as specified & directed. MAKE:- Crompton Greaves Cat Part No- LSTP-90-CDL-A / Bajaj Cat Part No: BRTFG 90W LED or techno- commercially equivalent model in Philips.
Ring made from 50mm dia mild steel pipe with supports of 0.80 metre dia including cap suitable for fixing on the existing pole with locking arrangement with and including provision of painting two coats with synthetic enamel paint over a coat of red-oxide primer and fixing the flood lights, complete all as specified and directed.
OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps, complete all as specified and directed.
OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps, complete all as specified and directed.
SHIVALIK ENGINEERING WORKS
Raj and satish enterprises
M/S SS Tarders
Mangalam Trades
M S G R ENTERPRISES
M/S UJJAWAL ENTERPRISES
M/s RAM LAKHAN GUPTA
R K GUPTA AND SONS
PITAMBARI TRADERS
MTR GROUP & COMPANY
Titco Electricals
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .