Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹40.1 L+₹3.6 L (9.93%)Rejected-Finance HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹45.0 L+₹8.5 L (23.3%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹99,320
Closing Date
19 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR/REPLACEMENT OF DUCTS WITH INSULATION AND SYSTEM EARTHINGS, MS AND GI WATER MAINS OF ASDC,TRC AND AMSS AC PLANTS AT SIGNAL ENCLAVE AND REPAIR/MAINTENANCE OF DESERT COOLERS AND COOLING APPLIANCES INSTALLED AT RRRC,RECORDS RRRC,202 BD COY,1 ETC.
2020_MES_393948_3
GE(U)/PM/D-72/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTT
MES contractor enlisted under class D category c(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹99,320
Yes
25 Jan 2021
1 Jan 2021
21 Jan 2021
1 Jan 2021
19 Jan 2021
7 Jan 2021
60 days
Amount
SECTION-I
Taking out old unserviceable MS pipes and Supplying & laying and mild steel (Heavy) 'C' class pipe of size 80 mm dia on exposed surface / duct including welding works, connections with existing chilled water line, chiller, pump, fabrication of bends, MS flange, tees, reducers, shoe, support (brick masonry block & wooden support for underground / MS angle- clamp & wooden support for exposed surface ) along with priming coat of steel primer as per standard specification. (Make : JINDAL/ TATA/ BST/ PRAKASH TUBES/ OSWAL) Note:- (i) The rates quoted by the contractor shall deemed to include the cost of MS fittings required during laying of MS Pipes. (ii) The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be heavy class of thickness min. 7mm as per IS: 3589
-ditto- all as per item No. 2 here-in-before but of size 100 mm dia
-ditto- all as per item No. 2 here in before but of size 125 mm M15
Taking out old unserviceable insulation of MS pipes, Supplying & fixing, insulation on existing MS 'C' class pipe on exposed surface / duct of size 80 mm, with 50 mm thick thermocole ( polystyrene) along with hessian cloth, wire mesh, bitumen, & cement - sand plaster, painting two or more coat to give even shade after applying one coat of ordinary paint etc complete as required.
-ditto- all as per item No. 5 here-in-before but of size 100 mm dia
-ditto- all as per item No. 5 here-in-before but of size 125 mm dia
S&F of Cooling Coil for AHU of 2x40 TR AC plant of ASDC at 1 AHQ Signal Enclave, with dimensions length 2210 mm, width 125mm, height 700mm and 04 row deep with 15 mm (1/2") dia copper tube, and copper header dia of 50mm (2") and 750mm (30") long - 02 Nos including taking down old unserviceable Cooling Coil complete all as specifed and directed.
S&F of Cooling Coil for AHU of 3x60 TR AC plant of AMSS at 1 AHQ Signal Enclave, with dimensions length 2241 mm, width 125mm, height 862mm and 04 row deep with 15 mm (1/2") dia copper tube, and copper header dia of 50mm (2") and 750mm (30") long - 02 Nos including taking down old unserviceable Cooling Coil complete all as specifed and directed. (Make: UNIVERSAL/CAIR/ ZECO)
S&F of Cooling Coil for AHU of 3x9 TR AC plant of ASDC at 1 AHQ Signal Enclave, with dimensions length 610 mm, width 125mm, height 500mm and 04 row deep with 15 mm (1/2") dia copper tube, and copper header dia of 50mm (2") and 750mm (30") long - 02 Nos including taking down old unserviceable Cooling Coil complete all as specifed and directed. (Make: UNIVERSAL/ CAIR/ ZECO)
Dismantling the existing water cooled condenser of capacity 60 TR of shell and tube type from it's pipe line and gas connection repairing the same by replacing the defective copper tubes of 19mm (3/4") and 2420 mm long by new pipes, cleaning the shell complete assembling the existing serviceable and new tubes, commissioning and testing upto 350 PSI pressure for satisfactory working complete all as specified and directed by Engineer-in-Charge. Note :- (i) Copper tubes of dia 19 mm and 2420mm long shall be measured and paid separately as 'Supply only' under relevent item. (ii) Taking down and fixing charge of copper tubes to be included in the quoted rate.
Supply only best quality copper tubes of thickness 1.26mm (18 SWG), 19mm dia and 2420mm long complete all as specified and directed. Note :- To be fixed under item No. 11.
Dismantling the existing old unserviceable exhaust fans of any size in AC plant installations, Supply, fixing and testing of new exhaust fans 450 mm sweep, 230 Volts AC, 50 HZ, 1440 RPM, including louvers and making all necessary arrangements like gouting of bolts on wall as per requirement, nuts, bolts and washes and FI legs and frame complete all as specified and directed by Engineer-in-Charge. (Make - Crompton Greaves/Khaitan/ Havells / Bajaj/ GEC/ Orient)
Taking out all electrical connections of old unserviceable squirrel cage motor of any capacity, S&F new squirrel cage induction motor of capacity 10 HP (7.5 KW), 3 phase, 440 + 10%, 50 Hz, 1440 RPM, IP-55, 4 Pole protected including necessary arrangements for mounting on existing angle iron frame, nuts, bolts and washers of suitable size, connecting with the existing compressor complete all as specified and directed by Engineer-in-Charge. (Make-ABB/Crompton/ Kirloskar/ KSB)
Supply and fixing in repairs Star Delta starters for motors upto 10 HP capacity with suitable rating relay, suitable for mounting on existing LT Panels of AC plants and connections with suitable size single core copper conductor wire complete all as specified and directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/Crompton.)
Dismantling the existing old unserviceable Monoblock Pump of any capacity and supply and fixing new monoblock pump set of 10 HP (7.5 KW) suction/delivery of size 100 mm x 100 mm CI casted, head 12.0 Mtrs, discharge, 32.00 LPS, Stainless steel impeller & pump shaft, mechanical seal, including 10 HP electric motor, copper wounded with 'F' class insulation & IP-55 protected, Cast Iron body, suitable for voltage range 300 to 440 Volts, ISI Marked, including making all electrical connections and testing for any leakage complete all as specified and directred by Engineer-in-Charge. (Make - Kirloskar pumps Model No. KDS 1030E or of equivalent in Crompton / KSB/ BEST & CROMPTON)
Taking out all electrical connections of the unserviceable cooling tower motor, dismantling the motor from the cooling towers of capacity 16 TR at HQ Delhi Area & 18 TR at 1 AHQ Signal Enclave AC Plant, S&F new cooling tower motor of capacity 1.00 HP, 3 phase, 50 Hz, suitable for Voltage operation range 360-440 Volts, AC, RPM-900 including aluminium fan hub assembly and fan blade. Complete all as specified and directed by Engineer-in-Charge. (Make-ABB/OSWAL/Crompton/ KSB/ KIRLOSKAR)
Supply and fixing in replacement DOL starters for motors upto 10 HP capacity with suitable rating relay, suitable for mounting on existing LT Panels of AC plants and connections with suitable size single core copper conductor wire complete all as specified and directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/Crompton.)
M & L for making high conductive ,corrosion resistant , maintenance free Chemical Earth pit for Servo Stablizers/Compressors made of brand 'Grip' or any other Equivalent brand having ISO 900111-2000 as approved by accepting officer comprising of chemical earth enhancing non ferrous compound containing no carbon or graphite filled in earth pit (Qty 50 Kg ) of bore hole of 200 to 250 mm and depth upto 3.3 mtr (approx) and comprising of "Fast earth electrode model F-84 MS (Double pipe technology based chemically pre- filled fully sealed earth electrode) or equivalent having ISO - 9001-2000 of size 88 mm outer dia and inner dia 48 mm and 3.00 mtr long made of high conductive Zinc coated Hot dip galvanized mild steel as per technically required to achieve resistance of 1-2 ohm along with heavy duty high density lockable plastic cover cum inspection chamber mounted on earthing electrode shall be fixed stainless steel fasteners including all other required accessories to complete the job of earth pit with earth termination to achieve rod resistance 1-2 ohms including taking down old unserviceable one comlete all as specified and as direced. (Make: POWERTRACK/ TIRUPATI/ ENOV/ CBO/ JMB/ JMV) Note :- (i) it is anexpress condition of the contract that all the earthing process should be done by the approved company applicators only. (ii) The approved firm shall isuue a certificate that all the earthing has been carried out by their applicator only and they stands gaurantee for the same for a period of 02 years from the date of physical completion of work.
Overhauling, testing and commisioning of open type reciproctaing compressor of capacity 60 TR Model No. 060665S. Make:Voltas. Overhauling includes disconnecting/dismantling suction and discharge valves, side covers other control accessories. Shifting the faulty compressor parts to the contractors workshop for certain required repairs. Refixing the same after repaired/Replaced parts in its original position under supervision of site-in-charge all as specified and directed by the Engineer-in-Charge. Note:- (i) Required Spare parts to be replaced during overhaluing shall be measured and paid seperatly as 'Supply only' under relevent items. (ii) Transportation charge & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
Supply only the follwing spare parts for the compressor of capacity 60 TR Model No. 060665S. Make:Voltas
Shaft seal assembly.
Liner.
Piston.
Main bush.
Gasket set for Voltas compressor Model No. 060665S.
Suction and discharge reed.
Piston ring set.
Piston pin with lock.
Half section bearings.
Brass bushes for connecting rods.
Oil strainer.
Oil pump for 60 TR Voltas compressor Model No. 060665S. Note for item No 21.01 to 21.12 :- (i) Materials of item Nos. 21.01 to 21.12 to be incorporated in item No 20 here-in-before. (ii) Make of item Nos. 21.01 to 21.12:- VOLTAS.
Overhauling, testing and commisioning of open type reciprocating compressor for model No. SMC 3-65 Make:Accel of capacity 9 TR. Overhauling includes disconnecting/dismantling suction and discharge valves, side covers other control accessories. Shifting the faulty compressor parts to the contractors workshop for certain required repairs. Refixing the repaired/Replaced parts in its original position under supervision of site-in-charge all as specified and directed by the Engineer-in-Charge. Note:- (i) Required Spare parts to be replaced during overhaluing shall be measured and paid seperatly as 'Supply only' under relevent items. (ii) Transportation charge & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
Supply only the follwing spare parts for the compressor model SMC-65 Make:Accel.
Shaft seal assembly.
Liner with suction valve.
Piston.
Main bush complete set of two.
Gasket set for SMC 3-65.
Discharge valve.
Suction and discharge reed.
Piston ring set.
Piston pin with lock.
CR Brass bushes.
Oil filter.
Suction strainer.
Oil pump for 8 TR compressor.
Rocker.
Rocker cup.
Spring holder.
Spring.
Cup washer.
Manual capacity regulator.
Magnetic plug assembly.
Half section bearing.
Connecting rod. Note for item No 23.01 to 23.22 :- (i) Materials of item Nos. 23.01 to 23.22 to be incorporated in item No 22 here-in-before. (ii) Make of item Nos. 23.01 to 23.22 :- ACCEL.
Disconnecting from mains/taking out existing unserviceable/defective motor of capacity 60 HP of any size, type, and make including disconnecting all electrical connections removing from foundation transporting to repair workshop disconnecting unserviceable burn out winding completely including insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, transporting back to site, re-installating, testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Disconnecting from mains/taking out existing unserviceable/defective motor of capacity 75 HP of any size, type, and make including disconnecting all electrical connections removing from foundation transporting to repair workshop disconnecting unserviceable burn out winding completely including insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, transporting back to site, re-installating, testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
M & L for Overhauling and repairing of any size refrigerant suction/ delivery liquid line valve including servicing of valve, replacement of packing material, sealing rings, Teflon washers and testing complete all as specified and as directed by Engineer-in-Charge.
Supply, testing and fixing in repairs of three pole power contactors of capacity MNX-18 including control wiring, thimbles, etc complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/ C & S.)
Supply, testing and fixing in repairs of three pole power contactors of capacity MNX-22 including control wiring, thimbles, etc complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/ C & S.)
Supply, testing and fixing in repairs of three pole power contactors of capacity MNX-25 including control wiring, thimbles, etc complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/ C & S.)
Supply, testing and fixing in repairs of three pole power contactors of capacity MNX-32 including control wiring, thimbles, etc complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/ C & S.)
Supply, testing and fixing in repairs of three pole power contactors of capacity MNX-40 including control wiring, thimbles, etc complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/ C & S.)
Supply, testing and fixing in repairs of three pole power contactors of capacity MNX-70 including control wiring, thimbles, etc complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/ C & S.)
Supply, testing and fixing in repairs of three pole power contactors of capacity ML-1.5 including control wiring, thimbles, etc complete all as specified and as directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/ C & S.)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, armoured, electric power cables (heavy duty) 1100 Volts grade with aluminium conductor of cross sectional area 35 Sqmm, 3 ½ core with galvanized steel strip or wire including taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. (Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.)
-ditto- all as per item No. 34 here-in-before but cross sectional area 70 Sqmm, 3 ½ core.
-ditto- all as per item No. 34 here-in-before but cross sectional area 95 Sqmm, 3 ½ core.
-ditto- all as per item No. 34 here-in-before but cross sectional area 120 Sqmm, 3 ½ core.
Supply and fixing in repairs cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of dia 65 mm complete all as specified and directed by the Engr-in-Charge. (Make :- ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
-ditto- all as per item No. 38 here-in-before but 80mm dia.
-ditto- all as per item No. 38 here-in-before but 100mm dia.
Supply and fixing in repairs Brass thermostatic expansion valve suitable for compressor of capacity 9 TR of make ACCEL Model 3-65 complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Brass thermostatic expansion valve suitable for compressor of capacity 40 TR of make Voltas, Model No. 05046 complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Brass thermostatic expansion valve suitable for compressor of capacity 60 TR of make Voltas Model No. 060665S complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs oil pump kit complete suitable for Voltas compressor, model No. 05046 of capacity 40 TR complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs oil pump kit complete suitable for Voltas compressor, model No. 060665S of capacity 60 TR complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs oil pump kit complete suitable for compressor model No. SMC 3-65 of capacity 9 TR of make ACCEL complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs 65mm dia cast iron non return valves of pressure class PN 16 including nuts, bolts, washers, gaskets, etc for Central type AC plants complete all as specifed and directed by Engineer-in-Charge. (Make :- ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO).
-ditto- all as per item No. 47 here-in-before but 80mm dia.
-ditto- all as per item No. 47 here-in-before but 100mm dia.
S&F in repairs Eliminator FRP for cooling towers. complete all as specifed and directed by Engineer-in-Charge
S&F in repairs PVC fills honey comb suitable for cooling towers complete all as specifed and directed by Engineer-in-Charge
Taking dwon serviceable motors for including all electrical connection and Dismantling the existing angle iron frame/stands of motors. Material & labour fabrication of new angle iron frame/stand of existing size and fixing of existing motors, including welding works, grouting legs with PCC 1:2:4 type B1(using 20mm graded stone aggregates) in the existing foundations, including foundation bolts, nuts and washers, re-mounting the motor on the new stand making all connections and testing for satisfactory working complete all as specified and directed by Engr-in-Charge.
Supply & fixing MCCB 4 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C&S)
Supply & fixing MCCB 3 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C&S)
Supply & fixing MCCB 4 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 4 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed by Engr-in-charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 200 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Supply & fixing MCCB 3 Pole of capacity 250 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ C & S.)
Demolition of cement concrete of any discription and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for Plain Cement concrete 1:2:4 type B1 (using 20mm graded stone aggregates) as in hardstanding, foundations, filling and mass concrete complete all as specified.
Supply and fixing in repairs gun metal gate valves with iron wheel head, screwed both ends for iron pipe, of size 40 mm bore complete all as specified and directed. (Make: KIRLOSKAR/ LEADER/ ZOLOTO/ AUDCO)
-ditto- all as per item No. 63 here-in-before but of size 50 mm bore
Supply and fixing in repairs V-belt of size B-76 complete all as specified and directed by Engr-in-Charge. Make - Feener or equivalent as approved by Accepting Officer.
Taking out the existing unserviceable PCB of the Central Type AC Plant of capacity 60 TR of make Voltas, transporting to authorised repair workshop carrying out the necessary repair and refixing the same in original position with the control panel of AC plant and testing for staisfactory working complete all as specified and directed by Engineer-in-Charge
Taking out the existing unserviceable PCB of the Central Type AC Plant of capacity 40 TR of make Bluestar transporting to authorised repair workshop carrying out the necessary repair and refixing the same in original postion with the control panel of AC plant and testing for staisfactory working complete all as specified and directed by Engineer-in-Charge.
Material & Labour for earthing with galvanised steel earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron wire 4mm as earth lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including taking down old unserviceable one complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead (GI strip) of size 25 x 4 mm fixed to plinth or buried in ground or drawn in GI pipe or any other situation as indicated for loop earthing etc including taking down old unserviceable one complete all as specified and directed.
Dismantling unserviceable ducting from walls, roofs, ceiling for repair /patch work /replacement complete all as specified and directed by Engr-in-charge.
Supply, assemble and errection of ducting, made up of GI Sheets of 1mm (20 guage) thickness as in Air Condition Ducting including fabrication for required size, patch work, fixing on walls, roofs or ceiling or in existing iron frame work including all accessories such as Corner, Cleat, Carriage bolt, Gasket, lap joint, welding, reverting and appropriate sealant on longitudinal joints etc. complete all as specified and as directed by Engr-in-charge. (Location:- HQ DGIS, CAMS IAHQ Singnal Enclave and HQ Delhi Area Signal Centre) (Make:- TATA/ JINDAL/ SAIL).
Material and Labour for 50mm thick fibre glass wool insulation in existing ducts of AC plants bonded with Aluminium foil, including wraping, pasting complete and cover the insulation one side with GI wire Mess netting after cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage including taking down old unserviceable glass wool insulation from existing duct complete all as directed by Engr-in-Charge. (Make:- Shri Fire Pack/ Impex Insulation/ Trans Insulation).
Material and Labour for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed by Engr-In-charge.
Dimolition of brick work set in cement mortor including all quoins, arches, pillars etc. complete all as specified and as directed.
M&L for brick work with will burnt bricks best quality locally available brick old size laid straight or curved on plan to any radius built in cement mortar 1:4, complete all as specified and directed
M&L for plastering 15mm thick on fair faces of brick work in cement mortar 1:4 and finishing the surface even & smooth (without using extra cement), complete all as specified and directed
Supply and topping up Refrigerant Gas R-22 complete all as specified & directed by Engr-in-Charge. (Make:- Mefron/ Floron/ Refron.)
Supply and topping up Compressor Oil N-68 complete all as specified & directed by Engr-in-Charge. (Make:- HPCL(Seetal)/ HP (Seetal)/ Servo.)
Taking out unserviceable defective finned strip heater and supply and fixing strip heater 3 KW suitable for AC plant including provision of nuts, bolts & washers etc all as specified and directed (Make:- DasPass or equivalent as approved by G.E.)
Taking out unserviceable defective finned strip heater and supply and fixing strip heater 2 KW suitable for AC plant including provision of nuts, bolts & washers etc all as specified and directed (Make:- DasPass or equivalent as approved by G.E.)
Supply and fixing Decorative ultra slim aluminium square profile LED lighting fitting 1 x 24W fixture with high lumen output, environmental friendly, easy to fit snap on adjustable installer compatible with energy saving tube lights including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- Havells Cat No. LHEXACP7IN1S024 or equivalent model or cat No of make in Philips/Crompton Greaves/ Bajaj)
Supply and fixing in repairs of MCB TP 415 volts 32 Amps, 10 kA, 'C' curve complete all as specified and directed by Engr-in-Charge. (Make : L&T/ SIEMENS/ LEGRAND/ ABB/ SCHNEIDER)
Supply and fixing in repairs of MCB TP 415 volts 40 Amps, 10 kA, 'C' curvecomplete all as specified and directed by Engr-in-Charge. (Make : L&T/ SIEMENS/ LEGRAND/ ABB/ SCHNEIDER)
Supply and fixing in repairs of MCB TP 415 volts 63 Amps, 10 kA, 'C' curvecomplete all as specified and directed by Engr-in-Charge. (Make : L&T/ SIEMENS/ LEGRAND/ ABB/ SCHNEIDER)
Supply & fixing in repairs integral LED street light fitting 45 watts comprising pressure die cast housing with powder coated aluminium housing working as a heat shrink and toughened glass suitable fixing with GI pipe bracket and pre-wired including necessary electric connection from ceiling rose to light fitting complete all as specified and directed by Engr-in-Charge. (Make:- Crompton Greaves Cat Part No. LSTS-45-CDL-1 equivalent model or cat No of make in Havells/Philips/ Bajaj.) (Note:- GI bracket along with clamp, nut & bolts shall be measured and paid seperately under relevent item.)
M&L for GI bracket 1.5m Long made out of GI pipe 'Light Grade" of 32m dia ( including bending of pipe fixing on pole with clamps of size 40 mm x 6mm of suitable length, nuts & bolts) for fixing of street leght fitting including taking down old unserviceable one complete all as specified & as directed ( make of pipe :- JINDAL PIPE/ TATA/ PRAKASH TUBES/ OSWAL)
Supply & fixing PVC insulated twin core copper conductor cable of size 2.5 sqmm for connection of street light fittings including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.)
Supply & fixing PVC insulated single core copper conductor cable of size 16 sqmm for connections in LT Panels including copper thimbles including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. (Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.)
Supply & fixing PVC insulated single core copper conductor cable of size 25 sqmm for connections in LT Panels including copper thimbles including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. (Make:- RR KABEL./ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS.)
Supply & fixing in repairs aluminium lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repairs aluminium lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repairs aluminium lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repairs aluminium lugs for cable of cross sectional area 35 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair switch disconnector fuse unit for Din type fuse FNX 200 TPN/FP complete all as specified and directed by Engr-in-Charge. (Make:-L&T Cat No. SK95816 or euivalent model/ cat No. of make Seimens/Legrand/ C&S/ABB).
Supply and fixing in repair of HRC fuse link, type HN, Cap 200 Amps complete all as specified and directed by Engr-in-Charge. (Make:-L&T Cat No. SK94232 or euivalent model/ cat No. of make Seimens/Legrand/ C&S/ABB).
SECTION-II
Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed.
Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. {Notes for item No. 97 & 98 :-(i) Two runs of cable with one runs earth wire and PVC casing caping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} (iv) (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries.) (v) (Make of PVC Casing caping:- FINOLEX / ANCHOR/ KALINGA/ SUPREME/ POLYCAB.)
Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge. Note :- (i). Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only'. (ii) Transportation charge if any & labour charges for taking down old spares and fixing of new spares shall deemed to be included in quoted rate.
Supply only over load protector relay suitable for 40/80 Ltrs capacity water coolers. (Make:- Renutrol/ Sri Ram/Microtech)
Supply only thermostat suitable for 40/80/120/150 Ltr capacity water coolers. (Make :- Indfos/ Renutrol).
Supply only condenser motor fan blade suitable for 40/80/120/150 Ltr capacity water coolers. (Make: Tipcon/ Usha/Epcos/Keltron)
Supply only PVC flexible drain Hose Pipe 40 mm. (Make:- Prayag/ Polytuff/Supreme/ Prince)
Supply only waste water tray PVC for 40/80, 60/120, 150/150 Ltr capacity water coolers. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make water cooler).
Supply only chromium plated push taps suitable for 40/80/120/150 Ltr capacity water coolers all as directed. (Make : Parryware/ Prayag/ Cera/ Essco.)
Supply only PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Ltr capacity water coolers including GI socket of same size all as directed. (Make:- Prayag/ Polytuff)
Supply only starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron)
Supply only running Capacitor 10 MFD. (Make :- Usha/Epcos/Keltron)
Supply only Starting relay suitable for 40/80, 60/120, 150/150 Ltr. (Make:- Renutrol/Sri Ram/ Microtech). Note for item No 100 to 109:- Materials of item No 100 to 109 to be incorporated in item No 99 here-in-before.
Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120, 150/150 Ltr and supply & fixing new fan motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make:- AUE/ Crompton Greaves / Cool Master)
-ditto- all as per item No.110 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs. (Make:- AUE/ Crompton Greaves / Cool Master)
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 40/80 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vacum the fully system and supply and charging of refrigerent gas R-22/134A and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG.)
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 60/120 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vacum the fully system and supply and charging of refrigerent gas R-22/134A and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG.)
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 150/150 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vacum the fully system and supply and charging of refrigerent gas R-22/134A and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG.)
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Ltrs complete all as specified & as directed. (Make:- Universal/ CAIR/ ZECO)
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water Coolers of capacity 40/80 Ltrs complete all as specified & as directed. (Make:- Universal/ CAIR/ ZECO)
Dismantling the evaporator/cooling coil of water cooler capacity 150/150, 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing the same complete all as specified & as directed by Engr-in-Charge.
Supplying and fixing in repairs of stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unions complete all as specified and as directed. (Make : Parryware/ Prayag/ Cera/ Essco.)
Taking down unserviceable PVC connection pipe and Supply & fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff)
Disconnecting from mains and taking down the unserviceable compressor unit of Refrigerator of approved make and type and providing New Compressor suitable for 165 to 210 ltr capacity alongwith test certificate from manufacturer including supply of the refrigerant gas R-22/ R-134A and filling and replacement of filter and put in working condition all as directed by Engineer-in-Charge. (Make :Tecumseh/LG/Emerson.) Note :- The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
Disconnecting from mains and taking down the unserviceable compressor unit of Refrigerator of any make and type and providing New Compressor suitable for 280 to 310 ltr capacity alongwith test certificate from manufacturer including supply of the refrigerant gas R-22/ R-134A and filling and replacement of filter and put in working condition all as directed by Engineer-in-Charge. (Make :Tecumseh/LG/Emerson.) Note :- The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
Disconnecting from mains and taking down for servicing of Refrigerator of Capacity 165/180/195/310 & 330 Ltrs including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the Refrigerator units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only following new spare parts of Refrigerator of capacity 165/180/195/310 & 330 Ltrs:-
Supply only capillary tube of existing size including necessary brazing suitable for 165/180/195/310 and 330 Ltrs capacity refrigerator complete all as specified and directed.
Supply only over load protector relay suitable for 165/180/195/310 and 330 Ltrs capacity refrigerator all as directed. (Make:- Renutrol/Sri Ram/Microtech)
Supply only thermostat suitable for 165/180/195/310 and 330 Ltrs capacity refrigerators all as directed. (Make :- Indfos/ Renutrol).
Supply only Freezer door with spring suitable for 165/180/195/310 and 330 Ltrs capacity. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Supply only vegetable basket with glass suitable for 165/180/195/310 and 330 Ltrs capacity refrigerators. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Water Cooler.)
Supply only PVC defrost tray suitable for 165/180/195/310 and 330 Ltrs capacity refrigerators. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Water Cooler.)
Supply only door gasket suitable for upto 250 Ltrs capacity refrigerators. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Water Cooler.)
Supply only door gasket suitable for more than 250 Ltrs and upto 330 Ltrs capacity refrigerators. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Water Cooler.) Note for Item No. 123.01 to 123.08:- Material of item No. 123.01 to 123.08 to be incorporated in item No. 122 here-in-before.
Disconnecting from mains and taking down for servicing of Deep freezer of Capacity upto 500 Ltrs including detecting the leakage of gas and refilling of refrigerant , cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the Deep Freezer units in satisfactory working condition will be measured & paid separately as 'Supply only' under relevant items and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only following new spare parts of Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
Starting relay 1/6 H.P. Open type with O.L.P. ( Make :- Renutrol/ Sri Ram/ Microtech).
Starting relay 1/8 H.P. open type with O.L.P. ( Make :- Renutrol/ Sri Ram/ Microtech).
Over load protector device for deep freezer upto 500 ltrs capacity. (Make: Sri Ram/ Renutrol/ Micro Tech.)
Running capacitor for deep freezer upto 500 ltrs capacity. (Make- USHA/EPCOS/KELTRON)
Thermostat switch for deep freezer upto 500 ltrs capacity.( Make :- Indfos/ Renutrol).
Starting capacitors for deep freezer upto 500 ltrs capacity. (Make:- Epcos/ Usha/ Keltron.)
Axial fan for deep freezer upto 500 ltrs capacity. Note for item No 125.01 to 125.07 :- Materials of item No 125.01 to 125.07 to be incorporated in item No 124 here-in-before.
Taking down defective compressor of deep freezer of capacity upto 300 Ltrs and any make and supplying and fixing new sealed unit compressor including brazing and with necessary nuts and bolts, copper filter, capillary and supply and charging of refrigerant gas Non CFC based or equivalent to Non CFC gas is required quantity and testing complete all as specified and directed by Engineer- in- Charge. (Make:- Emerson/ Tecumesh/ LG)
-ditto- all as per item No. 126 above but capacity above 300 Ltrs but upto 500 Ltrs deep freezer compressor. (Make:- Emerson/ Tecumesh/ LG)
Supply and fixing in repairs metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 40 Amps iincluding taking down old unserviceable metal clad socket complete all as specified and as directed. (Make : Schnieder/ Legrand/ ABB/ Seimens/L&T)
M&L for dismantling the existing window type air conditioner complete of capacity 1.5/2.0 TR, and re-fixing to any other locatin after servicing including cutting of window grills, covering the open space of old locatin and new place of fitting with 4mm thick plywood including two coats of synthetic enamel paints over a coat of pink primer complete all as specified and directed by Engineer-in-Charge. ( Make of ply:- Century/ Dura/ Greenply/ Kitply) (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
M&L for dismantling the existing Split type air conditioner complete including indoor and outdoor units of capacity 1.5/2.0 TR, and re-fixing to any other location after servicing including copper pipe with insulation upto 3 mtrs length & gas charging as per requirement and other fixing accessories complete all as specified and directed by Engineer-in-Charge.
S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white all as specified and directed by Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work as specified and re-fixing to existing place after repair work/overhauling complete all as specified and directed. Note :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P. (ii) Replacement of defective spares for making the Desert Cooler units in satisfactory working condition will be measured & paid separately as 'Supply only' under relevant items and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only wood wool pad (Set of three) approximate weight 800 - 900gms of size 24” sweep desert cooler complete all as specified and directed.
Supply only wood wool pad (Set of three) approximate weight 700 - 800gms and 20” sweep complete all as specified and directed. Note for item No 133 & 134:- Materials of item No 133 & 134 to be incorporated in item No 132 here-in-before.
Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make- Kirloskar/Bajaj/ Crompton Greaves/ KSS/ Khaitan.)
Supply and fixing in repairs of desert cooler kit fan motor copper wounded single speed having 1450 RPM, 90 watts with suitable for operation on 230 volts, 50Hz, AC supply including nuts, bolts, washers etc. of suitable size and all other fixing accessories complete all as specified & as directed. (Make:- Khaitan/ Crompton Greaves/ Usha.)
Supply and fixing in repairs of exhaust fan motor copper wounded having 1400 RPM, 150 watts with suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed. (Make:- Khaitan/ Crompton/ Cool master/ Havells/ Almonard.)
Supply and fixing in repairs of front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and as directed.
Supply & fixing in repairs of running capacitor of 4 MFD capacity complete all as specified and as directed. (Make- USHA/EPCOS/KELTRON)
Supply & fixing in repairs of running capacitor of 6 MFD capacity complete all as specified and as directed. (Make- USHA/EPCOS/KELTRON)
Supply & fixing in repairs of GI wire mesh (as per sample) for desert cooler pad (Set of Three) complete all as specified and as directed.
Supply & fixing in repairs of PVC pipe for connecting pump and water distributor of size 15 mm dia complete all as specified & as directed. (Make:- Prayag/ Supreme/ Prince).
Supply & fixing in repairs of PVC elbow for desert cooler of suitable size complete all as specified & as directed. (Make:- Prayag/ Polytuff).
Supply & fixing in repairs of PVC 4 Way distribution cross for desert cooler complete all as specified & as directed. (Make:- Prayag/ Polytuff).
Supply & fixing in repairs of flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed. (Make:- Polycab/ Kalinga Premium/Finolex/ RR Kabel/ Havells)
Supply & fixing in repairs of desert coolers fan blade of size '18 inch' sweep of aluminium body complete all as specified & as directed.
-ditto- all as per item No 146 here-in-before but '20 inch' sweep.
Supply and fixing in repairs of side panel of desert cooler of 20” (inch) sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply and fixing in repairs of switch piano flush type single pole one way 5Amp / 6 Amp 230 V for desert cooler all as directed (Make-Anchor/ Kinjal/ Havells).
Supply and fixing in repairs of 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells).
Supply and fixing in repairs of 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells).
Supply and fixing in repairs of cooler fan motor bracket sets made up as per existing including painting complete all as specified and directed.
Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height in stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Ajanta Associates
SNOWY ENGINEERING INC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .