Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance OFFICE NO 206 D WING EXTENSION RAIKER CHEMBER DEONAR VILLAGE ROAD GOVANDI EAST MUMBAI 88 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹1.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹10.2 L (7.87%)Admitted-Finance 101 B WING KANARA BUSINESS CENTRE LAXMI NAGAR GHATKOPAR E MUMBAI 400075 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | ₹1.4 Cr+₹10.2 L (7.87%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | INTERACTIVE INFO-COM (I) PVT LTD L2 | Arathi Electricals L1 |
|---|---|---|---|---|---|
| 1.00SITC of CAT -6 Cables as per TSS-1 | |||||
| 1.10 | Supply, installation, testing and commissioning of UTP CAT-6 LSZH cable as per TSS-1.1 | 38,000 | M | 35 ₹13,30,000 Lowest | 44 ₹16,72,000 |
| 1.20 | Supply, installation, testing and commissioning of armoured UTP CAT-6 LSZH cable as per TSS-1.2 | 5,000 | M | 95 ₹4,75,000 Lowest | 170 ₹8,50,000 |
| 2.00SITC of 3 No.s RJ 45 I/O port Information outlet with cover plate as per TSS 2 | |||||
| 2.10 | Supply, installation, testing and commissioning of 3 Nos. of RJ-45 information outlet in a suitable metallic boxes & face plate as per TSS-2.1 | 900 | Nos | 1,155 ₹10,39,500 | 500 ₹4,50,000 Lowest |
| 2.20 | Supply, installation, testing and commissioning of 3 Nos. of RJ-45 information outlet with frame and face plate suitable for installation in DLP trunking as per TSS-2.2 | 200 | Nos | 1,155 ₹2,31,000 | 600 ₹1,20,000 Lowest |
| 3.00Supply & installation of following size of PVC casing-capping as per TSS-3 | |||||
| 3.10 | 25 X16 mm size as per TSS-3.1 | 600 | M | 95 ₹57,000 | 35 ₹21,000 Lowest |
| 3.20 | 38 X 25 mm size as per TSS-3.2 | 2,000 | M | 125 ₹2,50,000 | 50 ₹1,00,000 Lowest |
| 4.00Straight joint of following cables along with supply and installation of respective jointing kits as per TSS-4 | |||||
Tender Value
₹1.4 Cr
EMD Value
₹3.2 L
Closing Date
30 May 2025, 6:00 pmClosed
CE and Head, CSS
1201, M1 Block, PG Hostel, Anushaktinagar
Augmentation and Maintenance of Telecom, LAN and Optical fiber cable network across various buildings inside BARC Trombay, Trombay Hill, BARC facilities at Anushaktinagar and EBC, Kharghar.
2025_BARC_859088_1
BARC/CSS/ET/6/2025-2026
Open Tender
Electrical Works
Item Rate
730 days
BARC Trombay, Anushaktinagar, Kharghar
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3.2 L
PG Hostel, Anushaktinagar
20 Jun 2025
20 May 2025
2 Jun 2025
20 May 2025
30 May 2025
20 May 2025
20 May 2025 - 27 May 2025
27 May 2025
Amount
SITC of CAT -6 Cables as per TSS-1
Supply, installation, testing and commissioning of UTP CAT-6 LSZH cable as per TSS-1.1
Supply, installation, testing and commissioning of armoured UTP CAT-6 LSZH cable as per TSS-1.2
SITC of 3 No.s RJ 45 I/O port Information outlet with cover plate as per TSS 2
Supply, installation, testing and commissioning of 3 Nos. of RJ-45 information outlet in a suitable metallic boxes & face plate as per TSS-2.1
Supply, installation, testing and commissioning of 3 Nos. of RJ-45 information outlet with frame and face plate suitable for installation in DLP trunking as per TSS-2.2
Supply & installation of following size of PVC casing-capping as per TSS-3
25 X16 mm size as per TSS-3.1
38 X 25 mm size as per TSS-3.2
Straight joint of following cables along with supply and installation of respective jointing kits as per TSS-4
200 Pairs PIJF Telephone cable Jointing as per TSS-4.1
100 Pairs PIJF Telephone cable Jointing as per TSS-4.2
50 Pairs PIJF Telephone cable Jointing as per TSS-4.3
48 Core OFC cable jointing as per TSS-4.4
24 Core OFC cable jointing as per TSS-4.5
Supply, installation, testing and Commissioning of following size UTP CAT-6 patch cords os per TSS No.5
3 feet or 1 M CAT-6 patch cords
7 feet or 2 M CAT-6 patch cords
10 feet or 3 M CAT-6 patch cords
Supply, Installation, Testing and Commissioming of Telephone and Optical Fiber cables as detailed below on Wall/Beam/Ceiling/False ceiling as per TSS-6
100 Pairs PIJF armoured telephone cable as per TSS-6.1
50 Pairs PIJF armoured telephone cable as per TSS-6.2
48 Core single mode Optical Fiber cable as per TSS-6.3
Supply, Installation, Testing and Commissioning of following cables through existing HDPE/RCC/GI Ducts laid underground as per TSS-7
100 Pairs PIJF armoured telephone cable as per TSS-7.1
50 Pairs PIJF armoured telephone cable as per TSS-7.2
Laying 48 core Optical fiber cables underground through HDPE Pipes as per TSS-7.3
Excavation of cable trench for laying of cables as per TSS-8
Soft soil
Murrum
Hard Rock / Road cutting / PCC cutting
Plain Cement Concrete (PCC) including supply and installation of 1:2:4 PCC concrete as per TSS - 9
End termination of following telephone and Optical Fiber cables including supply and installation of suitable end termination kit as per TSS-10
100 Pairs PIJF armoured telephone cable as per TSS-10.1
50 Pairs PIJF armoured telephone cable as per TSS-10.2
20 Pairs PIJF armoured telephone cable as per TSS-10.3
24 Core Single Mode OFC cable as per TSS-10.4
48 Core Single Mode OFC cable as per TSS-10.5
Supply installation ,testing & commissioning of LIU of the following sizes as per TSS 11
Supply, installation, testing and Commissioning of fully loaded 24 ports rack mount LIU including LC couplers (SMF) and pigtails etc. as per TSS No. 11.1
Supply, installation, testing and Commissioning of 48 ports rack mount LIU including LC couplers (SMF) and pigtails etc. as per TSS No. 11.2
Supply, Installation, Testing and Commisioning of 100 pair Telephone Feeder Pillar as per clause no.12 of Technical specifications
Supply, Installation, Testing and Commisioning of following powder coated telephone termination box as per clause no.13 of technical specification.
200 Pairs as per clause no.13.1 of TSS
100 Pairs as per clause no.13.2 of TSS
50 Pairs as per clause no.13.2 of TSS
Supply and Installation of DLP trunking of following sizes as per TSS-14
80 x 50 mm DLP as per TSS-14.1
150 x 80 mm DLP as per TSS-14.2
Supply, Installation, Testing and Commisioning of KRONE-LSA Connector modules as per TSS-15
KRONE-LSA 10 pair Modules as per TSS-15.1
KRONE-LSA 50 pair (10x5)Modules including SS base plate suitable for 19" Rack mounting as per TSS-15.2
Preventive and breakdown maintenance, attending complaints, Cleaning of MDF/FP/TTBs and monitoring of Telephone and Optical Fiber Passive system as per TSS- 16.
Supply and installation of HDPE Pipe of following size as per TSS No. 17
Supply and installation of 63 mm dia HDPE Pipe
Supply and installation of 50 mm dia HDPE Pipe
Testing of LAN cabling network with network analyser similar to Fluke Microscanner. This item include supply of 1 No. new Network Analyser and 4 Nos. of Crimping tool for termination and handing of the Analyser and all crimping tools to the department after completion of all testing and termination work as per TSS no. 18.
Supply, installation, testing and commissioning of rack mountable type 32 port Voice (phone) over optical fiber multiplexer and de-multiplexer units upto the range of 20 kM as per TSS No. 19
Supply, installation. testing ond Commissioning of fully loaded1 U size front openable rack mounted Patch/jack panel of the following sizes as per TSS 20
Supply, installation. testing ond Commissioning of fully loaded 24 port 1 U size front openable rack mounted Patch/jack panel along with 24 Nos. of RJ -45 jack as per TSS no. 20. 1
Supply, installation. testing ond Commissioning of fully loaded 48 port 1 U size front openable rack mounted Patch/jack panel along with 48 Nos. of RJ -45 jack as per TSS no. 20. 1
Supply, installation. testing and Commissioning of 1 G, 26 port ( 24 copper + 2 Fiber) Layer-2 network switch as per TSS No. 21
Power cabling: Supply,installation, tetsing and commissioning of Power cable with 3 core 4 sq.mm XLPE copper cable along with termination at both ends asper TSS 22
Power cables to be laid underground
Power cables to be wall/beam/ceiling
Power point wiring along with Supply, installation, testing and commissioning of switch board as per TSS-23
Supply, installation, testing and commissioning of Single mode optical fiber Patch cords of 1 m length as per TSS 24
Supply, installation, testing and commissioning of following 19" network racks as per TSS-25
Supply, installation, testing and commissioning of 9 U wall mounted network rack as per TSS 25.1
Supply, installation, testing and commissioning of 12 U double section wall mounted network rack as per TSS 25.2
12 U Pole mounted Rack; Supply, installation, testing and commissioning of pole mounting RACK 12 U along with erection of pole as per TSS 25.3
Supply, installation, testing and commissioning 36 U network rack inclusing supply and installation of MS platform as per TSS 25.4
Supply, installation, testing and commissioning 42 U network rack inclusing supply and installation of MS platform as per TSS 25.5
Supply, fabrication and installation of M.S. item made out of different sizes of M. S. angles, flats, plates, channels as per TSS 26
Supply, fabrication and installation of M.S. box made out of 16 SWG CRCA Sheet as per TSS 27
Supply, Installation, Testing and commisioning of Pipe Earthing station as per TSS 28
Supply and installation of GI Flexible pipe Heavy gauge 40mm dia as per TSS 29
INTERACTIVE INFO-COM (I) PVT LTD (BID ID -3221980)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.23 MB
TenderDocument.pdf
Tender Documents • 1.91 MB
SchedulesAtoF.pdf
Tender Documents • 0.63 MB
BOQ_904867.xls
BOQ • 0.25 MB
TECHNICAL_BID_BARC_CSS_ET_6_2025_2026.xls
Tender Documents • 0.18 MB
TechnicalSpecifications.pdf
Additional Documents • 0.90 MB
ScheduleA.pdf
Tender Documents • 0.76 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .