Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 CrAdmitted-Finance OLD HASIMARA DISTT JALPAIGURI WEST BENGAL PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | ₹6.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.6 Cr+₹10.6 L (1.64%)Admitted-Finance PO HASIMARA NEW MARKET DISTT ALIPURDUAR STATE WEST BENGAL PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹6.6 Cr+₹10.6 L (1.64%) | L2 | Admitted-Finance |
| 3 | L3₹7.0 Cr+₹49.2 L (7.58%)Admitted-Finance SITANI BUILDING DINBAZAR JALPAIGURI 735101 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735101 | ₹7.0 Cr+₹49.2 L (7.58%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DEEP NIRMAN L1 | M/S Sohanlal Agarwala L2 | M.P. SITANI AND SONS L3 |
|---|---|---|---|---|---|---|
| 1.00SCHEDULE 'A' PART-I (BUILDING WORKS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only. | ||||||
| 1.01 | Construction of FSP I / FSP II including compacted earth alround with RCC retaining wall, Toe wall etc, complete, all as specified and as shown on drawings. | 2 | Each Block | - | - | - |
| 1.02 | Construction of shed for DG Set including ramp, complete, all as specified and as shown on drawings. | 1 | Each | - | - | - |
| 2.00 | SCHEDULE 'A' PART- II
(SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | - | - | - |
| 3.00 | SCHEDULE 'A' PART- III
(INTERNAL ELECTRIFICATION)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | - | - | - |
| 4.00 | SCHEDULE 'A' PART-IV
(PCC ROAD )
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | - | - | - |
| 5.00 | SCHEDULE 'A' PART- V
(AREA DRAINAGE )
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | - | - | - |
| 6.00 | SCHEDULE 'A' PART- VI
(EXTERNAL ELECTRIFICATION)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | - | - | - |
| 7.00 | SCHEDULE 'A' PART-VII
(AIR CONDITIONING)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | - | - | - |
| 8.00 | SCHEDULE "A" PART-VIII
(LIGHTENING PROTECTION)
Details of prepriced Schedule is given in tender documents | 1 | Lump sum | - | - | - |
Tender Value
₹5.2 Cr
EMD Value
₹5.8 L
Closing Date
7 Mar 2020, 6:00 pmClosed
CE AF SHILLONG ZONE
HQ CHIEF ENGINEER (AF), SHILLONG ZONE, MILITARY ENGINEER SERVICES, ELEPHANT FALLS CAMP, PO NONGLYER, SHILLONG 793009
PROVISION OF FORWARD SUPPLY POINT (FSP) UNDER GE(AF) HASIMARA
2019_MES_307981_1
88402/HAS/E8
Open Tender
Civil Works
Lump-sum
365 days
HASIMARA
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE AF Hasimara
₹5.8 L
Yes
17 Mar 2020
20 Dec 2019
13 Mar 2020
20 Dec 2019
7 Mar 2020
10 Feb 2020
20 Dec 2019 - 28 Dec 2019
Amount
SCHEDULE 'A' PART-I (BUILDING WORKS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
Construction of FSP I / FSP II including compacted earth alround with RCC retaining wall, Toe wall etc, complete, all as specified and as shown on drawings.
Construction of shed for DG Set including ramp, complete, all as specified and as shown on drawings.
SCHEDULE 'A' PART- II (SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART-IV (PCC ROAD ) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- V (AREA DRAINAGE ) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VI (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART-VII (AIR CONDITIONING) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-VIII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART -IX (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES.
INTERNAL ELECTRIFICATION S & F for 1 x 70 W LED street light fitting new generation energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having toP opening seperate driver compartment with iP66 protection and impact resistance of iK07 with 10KV Built-in sPd. including LED lamp, input voltage range 220- 240 V, including neccesary electric connection with suitable size copper cable from junction box to light fitting with and including 50mm dia GI pipe light grade bracket of 1.5 m long including GI clamp of 40 x 5 mm, nut, bolt& washers with two coats of synthetic enamel paint over a coat of red oxide primer, complete, all as specified and directed. Make: Havells Cat No. LHETBXU7OA7B070 or equivalent approved make as per list of make
S & F for 1 x 80 W LED energy saving, environment friendly & robust Highbay/mediumbay led IP65 luminaire with high efficacy, including LED lamp, input voltage range 220- 240 V, including neccesary electric connection with suitable size copper cable from junction box to light fitting, complete, all as specified and directed. Make: Havells Cat No. LHELAQU7IG6W080 or equivalent approved make as per list of make
S & F for MCB SP 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs, complete, all as specified and directed.
S & F for MCB SPN 40 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs, complete, all as specified and directed.
S & F for MCB TPN 63 Amps (C-Curve), breaking capacity 10 KA, 415 volts with cable connection and copper lugs, complete, all as specified and directed.
S & F for MCCB 63 Amps, adjustable thermal and adjustable magnetic setting rapturing capacity 10 KA, FP, 415 Volt including all necessary incoming and outgoing electric connections, complete, all as specified and directed.
S & F for sub main wiring with 2 runs of single core 6 Sqmm (Nominal area) PVC insulated unsheathed multi-stranded copper conductor cable LT 1100 Volts grade (FR-LSH), drawn through in and including concealed PVC rigid conduit (medium grade) pipe of required size with accessories including earth continuity conductor using PVC insulated unsheathed copper conductor cable with one run of single core 6 Sqmm (Nominal area) (FR-LSH) connected to common earth dolly for controlling of hanger lights complete all as specified and as directed. Notes: 1) 3 runs of 6 sqmm and one run of concealed PVC (medium grade) conduit pipe with accessories shall be measured as one run length. 2) Cutting chases, making good disturbed surface shall be included in quoted lump sum of schedule 'A' Part-I and nothing extra shall be paid on this account.
M & L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised earth wire of size 4 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing complete all as specified and as directed.
S & F of factory made sheet enclosure double door designed vertical TPN DB 4 way recessaed/flush in wall complete with copper bus bar, neutral link, din rail suitable for mounting MCCB as incomer and MCB SP/SPN/TP as out going, complete, all as specified and directed.
PCC ROAD M & L for forming Dummy joints 100 mm to 133 mm deep x 5 mm wide, using diamond cutter with initial saw cut with 3 mm blade soon after concrete sets, widening the first saw cut to 8 mm wide and 22 mm deep from top, filled with expended polyethelene foam (Armour board, applying bond breaker tape on top of Armour board for complete width of joint) priming top 8 mm with approved primer, applying masking tape on edges of joint to prevent accidental spillage of sealant and sealed with polyurethane based sealant 13mm depth above back up rod (Complying with latest IRC-57-2006 with 10 year warranty) to closed cell, medium density, cross linked polyethylene back up rod of 10 mm dia, for complete width of joint and removing the masking tape after filling of sealant as per the directions of the manufacturer complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, installation, commissioning and testing of Silent diesel engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS: 10002, ISO - 3046, BS - 5514, DIN - 6271 of capacity 62.5 KVA, 4 Stroke, designed to run continuously at 1500 RPM complete with the following accessories:- (A) Diesel Engine:- (i) Radiator cooling (ii) Radiator fan with guard (iii) Fly wheel with starter ring (iv) Dry type air cleaner (v) Vacuum indicator (vi) Mechenical governor (vii) Exhaust silencer (viii) Fuel filter (ix) Inline fuel pump (x) Water pump (xi) Lub oil filter (xii)12 V DC electric start system complete with starter, battery charging alternator (xiii) Engine control panel consisting of starting key switch, lub oil pressure gauge, ammeter safety shut down system for low lube oil pressure and coolant temperature engine maintenance manual with spare parts list. (xiv) Exhaust pipe / stack upto 6m from top of shed with insulation structural steel required for supporting exhaust pipe / stack, fixed supports, sliding supports etc. (xv) First fill of lube oil and coolant. (xvi) Residential silencer with cladding & supports
ITEM No. 9.11 (Contd...\) (E) Accessories: (i) Base frame of sturdy design - 01 No (ii) Fuel tank rectangle shape capacity suitable for running 12 hrs on full load. (iii) Battery 12 V not less than 100 AH maintenance free with leads & connecting accessoies - 01 No. (F) Spare parts & tools: (i) Rotary pump diseal with 3 mt hose - 01 set (ii) Box spanner set complete with all sizes (iii) Oil filter set - 02 Nos (iv) Air filter complete with element - 02 Nos (v) Fuel filter set - 02 Nos (vi) AVR - 01 No (vii) Insulated rubber matt of size 900mm x 1500 mm x 2 mm thick confirming to IS 16652-2006 - 02 Nos (viii) Jerrican MS sheet of required capacity - 02 Nos Note : (i) PCC foundation of adequate/required size extending 500mm all round more than size of DG set, as per manufacturer design. (ii) DG set shall be tested as type test routine as per IS in presence of GE/his rep. (iii) Contractor shall submit QAP ( quality assurance programme ) after the 15 days from placement of order for DG set testing to factory. DG set shall be dispatch after inspection clearance by inspecting officer. (iv) The contractor shall get approval of GE for the make of DG set they plan to procure (v) Prior manufacturing the general arrangement drawing design details of the DG set and AMF panel shall be got approved by GE
S & F for MCCB 100 Amps, adjustable thermal and adjustable magnetic setting rapturing capacity 16 KA, FP, 415 Volt including suitable sheet metal enclosure supported on 4 legs duly grouted in PCC and all necessary incoming and outgoing electric connections, complete, all as specified and as directed.
S & F for MCB SPN 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs, complete, all as specified and directed.
AIR CONDITIONING S & F for voltage stabilizer automatic operation, single phase, naturally air cooled, copper wound, digital display, indoor type with digital voltmeter and designed for input variation between 160 Volt to 260 Volt with and output voltage stabilzed at 230V + 8% of capacity 5 KVA with time delay relay, under /over voltage relay and overload relay complete all as specified and as directed. MAKE: Microtek/V-Guard/LG
LIGHTENING PROTECTION Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 mm x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed.
M/S Sohanlal Agarwala
M.P. SITANI AND SONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .