Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹50.0 L TENDER CONDITIONS 3 OPENING OF PRICE BID DATED 31 08 2023 | ₹50.0 L |
Tender Value
₹50 L
EMD Value
₹50,000
Closing Date
14 Aug 2023, 11:00 amClosed
Setting up of Polymer Research Laboratory, Hindu College, University of Delhi
NBCC/SBGDelhi-I/NIT/HinduCollege/2023/70
NBCC/SBGDelhi-I/NIT/HinduCollege/2023/70
Open Tender-Domestic
Electronics Equipment
Patiala, Punjab
₹2,950
₹50,000
1 Aug 2026
5 Aug 2023
14 Aug 2023
14 Aug 2023
31 Aug 2023
Bill of Quantity - Re-tender for Setting up of Polymer Research Laboratory, Hindu College, University of Delhi
S.No. Item Description Unit Quantity DSR/NS Rate in Rs. Amount in Rs. Proposed Makes
Modulated Temperature · Principle of operation: Heat Flux
DSC · Working Temperature range : -85°C to atleast 450°C or better with intracooler & full
temperature range analysis must be in a single run
· DSC should produce raw data without any mathematical processing such as Deconvolution,
· Furance: Low mass Silver/Alumina Furnace for rapid heating/cooling and resistant to
· Temp. accuracy : ± 0.1°C/K or better (with Indium Reference material)
· Temp. precision : ± 0.03°C/K or better (with Indium Reference material)
· Heating and Cooloing Rate : 0.1 to 100°C/ min for entire temperature range or better
· Cooling time with Intracooler (100 to 0°C) : 5min or better
· Sensor : Thermocouple based, Chemical resistant, Corrosion resistant, Fixed/exchangeable
type sensor, heat flow measurement offering low signal time constant
· The Sensor should be an integral part of Furnace/ Replaceable. Furnace and Sensor should
have FIVE YEARS Warranty
· Resolution : 0.02µW or better
6 · Calorimetric Measurement range: ± 175 mW ( in complete temperature range -100ºC and Nos. 1 NS 500000 500000 Perkin/Mettler/TA
· Enthalpy Precision: 0.01 % or better
· Baseline curvature/Flatness: ±10 µw or better
(-50 °C to 350 °C at 5 K/min heating )
· Crucibles: 400nos. Aluminum (40 µl)
· Sealing press: One
· Should have Inbuilt Gas switching option with MFC and Software programmable
· Data acquisition/processing system : Windows based software should enable automatic /
manual on-line data acquisition and display of running measurements, Calibration. The multi-
tasking software should facilitate storage of both raw DSC data as well as deconvoluted data in
the form of standard DSC curves. The s/w should have the facility of choosing different baseline
e.g line, tangential, horizontal, spline, Integral tangential, polygon line etc for correct
evaluation/integration of peaks. Storage of results in tabular form (ASCII format) should be
Must include: Kinetics, Modulated & Cp software
DSC should have capability for Direct Cp measurement
Instrument should have capability to attach chiller/intracooler without changing instrument
· Application Support: Must have application Lab in India with qualified personnel to assist in
case of application related queries & factory trained engineer.
Warranty : ( 1 ) Instrument should have standard Warranty of One Year from date of
installation ( 2 ) Five Years Warranty on Furnace and Sensor.
Digitally signed by AVDHESH
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT .pdf
Tender Document
BOQ.pdf
Tender Document
GCC Contractor 2022 - PMC - Amendments upto 05.pdf
Tender Document
corrigendum-1879-Corrigendum 01.pdf
pdf • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .