Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹42.4 L+₹2.1 L (5.22%)Rejected-AOC | L2 | Rejected-AOC Bidder quoted L2 rates | |
| 3 | L3₹43.6 L+₹3.3 L (8.12%)Rejected-AOC | L3 | Rejected-AOC Bidder quoted L3 rates | |
| 4 | L4₹43.8 L+₹3.5 L (8.62%)Rejected-AOC | L4 | Rejected-AOC Bidder quoted L4 rates | |
| 5 | L5₹55.1 L+₹14.8 L (36.6%)Rejected-AOC | L5 | Rejected-AOC Bidder quoted L5 rates |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
10 Mar 2020, 6:00 pmClosed
GE SOUTH PUNE
No 1 General Bhagat Marg Pune 411040
8853 PROVN OF GUARD ROOM WITH ATTACH TOILETS AND BATHROOM AT MACHAN POST AND TRG SHED AT 4/5 GRFF AND SPL REPAIRS TO ROOF TREATMENT AT UNIT LOCATION AND CERTAIN REVENUE, MINOR WORKS IN MHCTC UNDER AGE BR I SOUTH PUNE
2020_MES_316639_2
8853 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
183 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹86,000
Yes
20 Mar 2020
24 Feb 2020
12 Mar 2020
24 Feb 2020
10 Mar 2020
26 Feb 2020
Amount
Surface excavation not exc 30 cm deep and averaging 15 cm and getting out hard dense soil complete all as specified and as directed.
Surface excavation not exc 30 cm deep and averaging 15 cm and getting out soft / loose soil complete all as specified and as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation in hard /dense soil complete all as specified and as directed.
M&L for PCC in foundation in 1:4:8 type D2 (40mm garded agg) in foundation filling and mass concrete complete all as specified and as directed.
M&L for Hard core of guage n.exc 63 mm ,deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surfaces with broken stone boulders complete all as specified and as directed.
M & L for Moorum / red bajari filling in floors or pavings laid in layers n.exc 15 cm thick spread leveled & rammed including watering complete all as specified and as directed.
M&L for pre-polished machine cut kota stone 18 to 20 mm thick as in skirting /dado, set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of kota stone slab, laid over and including 10 mm thick backing coat in cement mortar 1:4 all as specified and as directed.
M&L for PCC 1:3:6, type C2 75mm thick fair finished surfaces as in plinth protection/ foot path complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removal of excavated material not exc 50M and deposited where directed at a level n.exc 1.5 Mtr above from starting point complete all as specified and as directed.
M&L for RCC 1:1.5 : 3 type A1 ( 20mm graded aggregate ) in foundation and plinth beams complete all as specified and as directed.
M&L for RCC 1:1.5 : 3 type A1( 20mm graded aggregate ) in columns complete all as specified and as directed.
M&L for RCC 1:1.5 : 3 type A1( 20mm graded aggregate ) in beams complete all as specified and as directed.
M&L for RCC 1:1.5 : 3 type A1( 20mm graded aggregate ) in slabs complete all as specified and as directed.
M&L for RCC 1:1.5 : 3 type A1( 20mm graded aggregate ) in fin, facias,lintils etc complete all as specified and as directed.
M&L for form work to sides of foundation,footing & plinth beams fair finished surfaces complete all as specified and as directed.
M&L for form work to sides of columns fair finished surfaces complete all as specified and as directed.
M&L for form work to sides and soffits of beams fair finished surfaces complete all as specified and as directed.
M&L for form work to soffits of slab n.exc 200 mm thick fair finished surfaces complete all as specified and as directed.
M&L for form work to fins and facias fair finished surfaces complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over in reinforcement incl cutting bending and binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified and as directed.
S&F mild steel TMT bars 6 to 8 mm dia and over in reinforcement incl cutting bending and binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified and as directed.
All as per Sl Item No. 22.00 above but 5mm dia and over upto and incl 10mm dia in stirrups complete all as specified and as directed.
M&L for concrete bed to drain pipes incl forming cradles Cement concrete 1:3:6, type C2 using 40mm graded stone aggregate bore of pipe 200mm complete all as specified and as directed.
M&L for RCC pipes class NP-2 with socketed ends laid and jointed collars complete of 200 mm bore of pipe complete all as specified and as directed.
M&L for rendering 5mm thick cement plaster surfaces using CM (1:4) by using ready mix plaster etc including sagol finish complete all as specified and as directed. (Make : Godrej / Build well / Ascolite)
M&L for rendering 10mm thick cement plaster surfaces using CM (1:4) by using ready mix plaster etc including sagol finish complete all as specified and as directed. (Make : Godrej / Build well / Ascolite)
M&L for rendering 10mm thick cement plaster surfaces using CM (1:6) by using ready mix plaster etc including sagol finish complete all as specified and as directed. (Make : Godrej / Build well / Ascolite)
M&L for rendering 15mm thick cement plaster surfaces using CM (1:4) by using ready mix plaster etc including sagol finish complete all as specified and as directed. (Make : Godrej / Build well / Ascolite)
M&L for rendering 15mm thick cement plaster surfaces using CM (1:6) by using ready mix plaster etc including sagol finish using WPC compound complete all as specified and as directed. (Make : Godrej / Build well / Ascolite)
M&L for cement concrete type D2 1:4:8 (40mm graded agg) 100 mm thick in sub base floor complete all as specified and as directed.
M&L for cement concrete type B 0 1:2:4 using 12.5 mm graded aggregate, providing cement concrete in roof kerb or mud stops, rounded or chamfered on edges and in coping complete all as specified and as directed.
M&L for Non skid ceramic tiles flooring 7 to 8 mm thick area of each tile exceeding 0.06 sqm and not exc 0.11 sqm (300x300mm) with joint free tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick cement screed bed in CM 1:6 complete all as specified and as directed.
M&L for glazed ceramic tiles in vertical surface 300x200x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick cement screed plaster in CM 1:4 complete all as specified and as directed.
S&F in repair vitreous china wash hand basin, white, 550x 400mm flat back including providing CI brackets/steel fastners, PVC waste pipe 32mm dia, CP brass waste coupling 32mm dia etc all as specified and directed.
S&F concealed GI tubing tubes "medium grade" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc. of the following sizes :-
15 mm bore
20 mm bore
S & F PVC (SWR) pipes single socketed in any length 110 mm dia complete all as specified and as directed.
S & F PVC (SWR) pipes single socketed in any length 75mm dia complete all as specified and as directed.
S & F PVC (SWR) bend/L bow 110 mm dia complete all as specified and as directed.
S & F PVC (SWR) bend/L bow 75mm dia complete all as specified and as directed.
S & F PVC(SWR) branch piece double equal or unequal complete all as specified and as directed.
S&F PVC (SWR) vent cowl 75 mm dia complete all as specified and as directed.
S&F PVC (SWR) reducers 110 x75mm mm dia complete all as specified and as directed.
S&F PVC (SWR) gully trap 110mm/125mm with grating complete all as specified and as directed.
S&F Bib taps cast copper alloy with cruch or butterfly handle 15mm bore CP fancy type complete all as specified and as directed.
S&F pillar taps, fancy type, CP 15mm dia cast copper alloy with capstan heads, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe.
S&F stop valve/ stop cock cast copper alloy CP for 15mm bore fancy type complete all as specified and as directed.
All as per Sl. No. 47.00 above fixed for 20mm bore pipe complete all as specified and as directed.
S&F ball valve brass with polythelene float and fly nut fixed complete for 20 mm bore of pipe complete all as specified and as directed.
S&F towel rail 600mm long PTMT fixed with brass screws complete all as specified and as directed.
S&F PVC connection 15 mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F vitreous china, squatting pan, 'Orissa' pattern, size 580 x 440mm white, with integral foot rest, including concrete bedding and PVC flushing cistern 10 Ltr capacity including all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed.
S&F PVC (SWR) floor trap, dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F PTMT waste coupling 32 mm dia complete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm prelaminated colour PVC sheet, reinforced with MS square tube, all as mentioned in Item No. 8095 of SSR Part-II complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made cut of M.S tubes for top & bottom rails; M.S frame shall be covered with heat moulded plain colour PVC ‘C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelaminated PVC sheet 5mm thick for top rail, lock rail and bottom rail and stile and rails having one side feathered edge, on other side 10mm 90° bent edge, panelling to be fitted in MS frame welded/sealed to the stiles and rails and 15mm thick PVC sheet beading inside and decorative PVC beading of 10mm x 10mm all as specified and directed and as per product Drg given on Sl. Page No. 157 of SSR Part-II 2010 complete all as specified and as directed.
S & F pressed steel frames for doors with one or more rebates incl necessary hold fasts, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm filled with PCC 1:3:6 type C-0 complete all as specified and as directed.
S & F IInd class hard wood 35mm thick factory made, panelled shutter (two/three panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneer particle board with commercial veneering on both faces, size of the rail as per IS 1003 (Part-I) Kiln seasoned and chemically pressure treated complete all as specified and as directed.
S & F IInd class hard wood 35mm thick factory made, glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc. edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass,etc; The size of the rail and stile as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated.
S & F three track sliding window with two or more shutter with 4 mm thick plaint / tinted glass, one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing, handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge:- (a) Bottom frame rail 20619, (b) Top frame & vertical 20681, (c) Handle (Side) 20606, (d) Shutter inter lock 20724 , (d) Shutter top & bottom 20844
S & F in repairs ventilators/louvers using 5mm thick plain/frosted glass and following aluminium powder, coated section conforming to catalouge of 'JINDAL ' or of equivalent make and rubber beading etc all as directed : - (a) SP 20048 , (b) Glazing clips 19352
S & F 4 mm thick frosted glass and glazing with oil putty in square n exc 0.5 Sqm in each pane to steel windows including glazing pins etc. complete all as specified and directed by the Engineer-in-Charge.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18 mm & fixed with stainless steel wire staples all as specified.
M&L for mild steel electroplated butt hinges 100mm medium weight complete all as specified and as directed.
S&F mild steel electroplated sliding bolt 250 long fixed with bolts & nuts complete all as specified and as directed.
S&F mild steel tower bolts 150mm long complete all as specified and as directed.
S&F mild steel powder coated handles 150mm complete all as specified and as directed.
S&F preparation of steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer incl preparation of surface complete all as specified and as directed.
M&L for preparation of wall/ ceiling surfaces and applying two coats of dry distemper over a coat of chalk white primer incl preparation of surface complete all as specified and as directed.
M & L for preparation new plastered surfaces of walls and applying two coats of weatherproof exterior emulsion complete all as specified and as directed.
M&L for preparation of wood surfaces and applying 2 coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
S&F three layer rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) of capacity 500 Ltrs hoisted and fixed in position all as specified in SSR Part-I,including 20mm dia float ball valve high pressure of PTMT complete set etc. complete all as specified and as directed.
M&L for 25mm thick modified screed layer on treated surface of cement mortar 1:4 using necessary plasticizers. This screed should be finally treated with polymer modified white cement slurry complete all as specified and as directed. (Note :- Necessary plasticizers is to be measured and paid separetly and used as per manufacutrers insturctions.)
M&L for PCC 1:2:4 type B1 using 20mm graded aggreagate as in hardstanding/approaches of 75mm thick complete all as specified and as directed.
S&F aluminium powder coated fancy type brackets complete all as specified and as directed.
S&F aluminium powder coated fancy type curtain rod 20mm bore all as specified & directed by Engr-in-Charge.
S & F Machine cut cuddappa stone slab one side polished 20 to 25mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 20mm screed bed in cement mortar (1:6) complete all as specified and as directed.
M & L for precast factory made manhole cover of medium duty, area of each cover n.exc. 0.75 sqm, 100 mm thick with SFRC concreting including groove and hook arrangement for lifting and placing in position and set CM 1:4 and sides covered by MS sheet with necessary collars all as specified and directed.
M&L for PCC 1:2:4 type B-1, (using 20mm graded stone aggregate)as in surface channels and drains incl all moulds and forms all as spd and directed.
Extra for forming fair finished drain or channel inner girth n.exc 30 CM in cement, concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, for 200 mm bore size of pipe complete all as specified and as directed.
Excavation of post hole each not exc 0.5 Cum & getting out in hard/dense soil incl returning , filling and removal excated material exceeding 50 mtrs and n.exc 250 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed by Engr-in-charge.
M&L for PCC 1:2:4 type B-2 (using 40mm graded stone aggreagate) as in foundations fillings and mass concrete complete all as specified and as directed.
S&F MS structural steel like channel, angle, steel square tubes confirming to IS Fe-410 W fixed independently without connecting plates etc. complete all as specified and as directed.
M&L for MS structural steel work confirming to Fe-410-W (Gde E-250) as in main and cross beam, hip and jack rafters; purlins & simiar works etc all as specified and directed.
S&F MS structural steel as in trusses and like including butt welding etc special shaped washer etc. complete all as specified and as diected.
S&F pre-painted galvalume aluminium zinc coated 150 gms GI based corrugated steel sheet 0.50 mm thick fixed in any position where directed of any colour having tensile strength of 550 Mpa, high gloss, as in roof covering / cladding to wall, fixed with self tapping screw with one corrugated side lap, bent to shape complete all as specified and as directed. (Note : Unit rate is deemped to be inclusive of dismantling and refixing of earthing strip in roof/wall)
M&L for precast cement concrete interlocking paver blocks, coloured, glossy finish with any shape and size conforming to IS-15658-2006, 60mm thick, M-35 grade, laid over & including 75mm thick stone dust/grit all as specified and as directed.
M&L for PCC 1:2:4 type B-1, (using 20mm graded stone aggregate), 100mm thick, laid in alternate bays including finishing the surfaces even and smooth using extra cement complete all as specified and as directed.
M&L for 400x400x5.5 to 6mm thick, coloured, glazed ceramic tiles as in skirting/Dado, laid and jointed in neat cement slurry and pointed in coloured cement to match complete over and including 10mm thick backing coat in CM 1:4 including triangular filleting on top in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for 400 x 400 x 8 mm thick, joint free, non skid ceramic coloured tiles, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20mm thick screed bed in CM 1:6 complete all as directed by Engr-in-Charge.
M&L for hand cut kota stone slab flooring 19 to 20mm thick over cement screed base laid and jointed with grey cement slury mixed with pigment to match the shade of the slab including rubbing and polishing complete, including 20mm thick screed bed in CM 1:6 complete all as specified & directed.
M & L for Water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and incl taking down old water proofing treatment incl screed bed and foreign material as directed by Engineer-in-Charge including taking down old waterproofing treatement. (a) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified (c) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 Kg/Sqm with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge
Taking up or down carefully steel tubing and connections including cleaning for refixing or removal to store of size :-
15mm bore
20mm bore
25mm bore
Refixing old steel tubing (concealed) and connections in new or old postion (wall/floor/ceilings etc) of following size :-
15mm bore
20mm bore
25mm bore
S&F GI tubing 25mm bore tube "medium grade" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc (concealed type) complete all as specified and as directed.
Cutting chases, pinning in making good to facing where required and pointing in CM 1:4 for consealed water tubing etc complete all as specified and as directed.
Demolition of PCC coping, benching at the junction of roof and gable wall complete all as specified and as directed.
M&L for providing PCC (1:2:4) type B0 (using 12.5mm graded stone agg) as in roof kerbs and mud stope rounded or chamfered on edges and laid as base of water tank, roof slab and any other locations with water profing compound complete all as specified & directed.
Taking down cement plaster on brick/ block walling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Supply only intergral water profing compound
M&L for new palstered surface of wall and applying two coats of oil bound distember over a coat of primer including applying 3mm thick wall care putty all as spd and directed.
Preparation of new plastered surfaces and applying two coats of cement base paint complete all as specified and as directed.
Disconnecting existing tanks exc 250 ltr and n exc 500 ltrs setting aside (or lowering if required) for repairs , cleanign and hoisting if required reconnecting and re-fixing in position (Cleanig repairing etc measured separately) complete all as specified and directed by Engr in charge.
All as per item No. 104.00 above but capacity exceeding 500 ltrs and not exceeding 1000 ltrs complete all as specified and as directed.
All as per item No. 104.00 above but capacity exceeding 1000 ltrs and not exceeding 2000 ltrs complete all as specified and as directed.
Dismantling water tanks of capacity not exc. 250 Ltrs and not exc. 500 ltrs removing to stores complete all as specified and as directed.
All as per item No. 107.00 above but capacity exceeding 500 ltrs and not exceeding 1000 ltrs complete all as specified and as directed.
All as per item 107.00 above but capacity exceeding 1000 ltrs and not exceeding 2000 ltrs complete all as specified and as directed.
S&F rotational three layer moulded polythylene water storage tanks of (cylindrical vertical with colsed top) hoisted and fixed in postion all as spd and directed of 500 ltrs capacity incl 15 mm dia brass float incl tank nipple complete set of ISI marked complete all as specified and as directed.
S&F three layer rotational moulded polythylene water storage tanks (cylindrical vertical with colsed top) hoisted and fixed in postion all as spd and directed of 1000 ltrs capacity.incl 20 mm dia brass float incl tank nipple complete set of ISI marked complete all as specified and as directed.
S&F three layer rotational moulded polythylene water storage tanks (cylindrical vertical with colsed top) hoisted and fixed in postion all as spd and directed of 2000 ltrs capacityincl 25 mm dia brass float incl tank nipple complete set of ISI marked complete all as specified and as directed.
Preparation of old decorated surfaces of walls, soffits/ facia of chajja/ roof slab etc and applying two coat of cement base paint white or tinted all as directed. (Make : Asian paint/Nerolac/Berger)
M&L for preparation of old decorative surfaces and providing two coat of weather proof exterior emulsion paint on walls complete all as specified and directed. (Make : Asian paint/Nerolac/Berger)
M&L Providing Cement Concrete, Type B-O, 1:2:4 (12.50 mm graded stone aggregate) 50 mm thick as in roof padding and the concrete surfaces is to be finished even and smooth without using extra cement complete all as specified and as directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed by Engr-in-Charge.
M&L plain cement concrete 1: 3 :6, type C-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and as directed.
M & L for 25 mm thick PCC (1:2:4) type Bo(12.5mm graded stone aggregate) as in leveling course of floor tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L for MS structural steel work, framed as in trusses, purlins, rafter, post etc. conforming to grade E-250 (Fe-410W, quality A) including shaped washers including necessary cutting required length, notching drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plat, gusset plate and also erecting in true position complete as directed.
M&L preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete as specified and directed.
S&F collasible steel gate, top hung, consisiting of channel pickets, pioted flat bars, top and bottom runners brass handles etc, as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises as directed.
M&L for coloured ceramic tiles 7 to 8 mm thick 600 x 600mm size of approved colour, set, jointed in cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 20 mm thick screed bed in CM 1:6 etc complete as in flooring all as specified and directed.
M&L for glazed coloured digital printed ceramic tiles of size 300mm x 450mm x 7mm thick in vertical surfaces etc set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles including 10mm thick backing coat in CM (1:4) and filleting at top etc complete all as specified and as directed.
M&L for 12mm thick rendering on pcc/concrete block wall surfaces in CM 1:6 finished with sagol finish to plastered surface etc. complete all as specified and as directed.
M&L for providing and fixing CP toilet fitting in repairs as specified and as directed by the Engr -in-Charge for the following:-.
Bib Cock CAT No. CON- 037KN
Soap dish CAT No. ACN-1131 N
Towel ring square CAT No. ACN 1121 N
Coat hook CAT No. ACN 1191 N
Single Towel rail 600mm long CAT No. ACN 1111 NM
Angular stop cock conforming to CAT No. 053 KN of "Jaquar" or of equivalent make specified here-in-after.
CP 15mm bore concealed stop cock regular body conforming to CAT No. CON-083KN of "Jaquar" or of Equivalent make specified here in after
M&L for gun metal globe valve with iron wheel fixed for 20mm bore pipe complete all as specified and as directed.
M&L for ball valve brass with polythelene float and fly nut fixed complete for 20 mm bore of pipe complete all as specified and as directed.
S&F oval shaped coloured vitreous china WHB of overall 600mm size including 32mm CP waste coupling, PVC waste pipe etc complete including Pillar cock long neck with aerator CAT No CON -021KN (Make - Jaquar or of equivalent make specified here in after) directed by Engr-in-Charge.
S & F in repairs, vitreous china wash down water closet pan (pedestal pattern), white, 'P' or 'S' type, inc. 10 litres, PVC flushing cistern, L L, white, with inlet,ball valve, float & brackets, inc. flush pipe, PVC tube 32mm dia. & inc. plastic water closet seat, black, closed pattern with flat bottem, & cover & M S CP or aluminium hinging device complete all as specified and as directed.
M&L for PVC floor trap 100mm including jointing with CM 1:4 complete all as specified and as directed.
M&L for Grating doom 100mm dia PTMT complete all as specified and as directed.
M&L for preparation of wall/ ceiling surfaces and applying two coats of oil bound distemper over a coat of alkali resistance primer incl preparation of surface complete all as specified and as directed.
M&L for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top )hoisted and fixed in position with all fittings and fixture all as specified in SSR Part 1 capacity 1000 litres incl PTMT float valve with PVC ball 20mm bore of pipe complete all as specified and as directed.
S & F fixed glass ventilators using 5mm thick plain glass and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc all as directed :- (a) SP 20048 (b) Glazing clips 19352
S & F GI tubing and connections medium grade of following size complete fixed to walls :-
15mm bore
20 mm bore
M&L for Granite slab, 18 to 20 mm thick of approved colour, laying in design pattern using approved colour granite slab strips all as directed by Engr-in-Charge, laid bedded & jointed in neat cement slurry and pointed in white/coloured cement to match the shade of slab, laid over and including 20 mm thick, screed bed in CM 1:6 including rubbing and polishing complete as in floors complete all as specified and as directed.
M&L for Gypsum ceiling board for ceiling prepainted, perforated finish, 600 x 600 x 9 to 9.5mm thick in size, of approved brand/make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle. hung from ceiling using 2 mm thick G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans/light at as specified and directed.
S&F Vitreous China urinals, half stall type, white Complete all as specified and directed by Engr-in-Charge.
M & L for wiring complete with 1.5 sqmm single core FRLS grade PVC insulated unsheathed,1100V grade IS-694 marked, with multistranded copper concuctors and earth continutiy wire with 1.5Sqmm cable (including connecting ot earth dolly) laid/fixed in conceal conduit on walls/ceiling and also including sunk typed pressed steel terminal box and 3mm thick plastic laminated sheet top covers for one light/fans/exhaust fan point controled by one number one way 5A switch complete all as specified and as specified
All as per Sl Item No. 140.00 above but 5 Amps Socket Outlet point controlled by one switch on independent board complete all as specified and as directed.
All as per Sl Item No. 140.00 above but 5 Amps Socket Outlet point controlled by one switch on same board complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable with tripple layers protection drawn through in and including ISI marked heavy duty PVC concealed conduit including all accessories etc, with mild steel sunken boxes with earth dolly duly covered laminated bakelite sheet of min thickness of 3mm suitable for suitable for switches / sockets etc. including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete including cutting and chasing in the wall for box complete all as specified and directed. (Note : Cutting / chasing in the wall included in the quoted rates)
S&F switch flush type 5 Amp 240 Volts single one way (ISI marked) complete all as specified and as directed.
S&F socket outlet, 5 amps, 5 pin 230 volts, flush type complete all as specified and as directed.
S&F switch socket outlet combination multipurpose 2 in 1, 5/15 amps, 230 volts flush type complete all as specified and as directed.
S&F switch piano flush type, 15 amps, 230 volts, single pole one way complete all as specified and as directed.
S&F ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed.
Supply and fix LED integrated battenT-5 Nakshatra series tube light fitting pre-wired with high efficacy electronic driver,glare free smooth light distribution including LED tube 1x18/20W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable conforming to Cat No.LTTB4F20WLED/W of C&S or equivalent model of Bajaj / Philips complete all as specified and as specified
S&F lamp holder (angle / bracket) insulated body with base plate completed all as directed by Engr-in-charge. (Make - Anchor,Phillips or equivalent complete all as specified and as directed.)
Supply and fixing Ceiling fan 230 volts 1200 mm sweep BEE 5 star rated with all accessories MS Clamp, Down rod, electronic step type fan regulator complete all as specified and as directed. [Make - Havells / Orient / Usha]
M&L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
M&L for ventilating Exhaust fan 300mm sweep,230 volts metal frame with blades and louvres fixing on wall complete with nut bolts incl duct for exhaust complete all as specified and as specified (Make : Bajaj / Havells / Crompton)
Supply fix MCB DB of sheet metal enclosure double door SPN 4 way with 200 Amps rated bus bar 230 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as specified
Supply MCBs, SP 6 to 32 Amps, 10 KA , IS/IEC 60898-12002 marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as specified (Make:- Legrand/Havells/ Schnider)
Supply MCBs, SPN 40 to 63 Amps, 10 KA , IS/IEC 60898-12002 marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as specified. (Make:- Legrand/Havells/ Schnider)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and as specified
Excavating in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter depth and getting out in soft/loose soil complete all as specified and as directed
M&L for laying of Reinforced concrete pipes, class NP-2 with one collar per length of pipe of dia 150mm, full round and before laying excavated area shall be levelling complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all specified and as directed.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and as directed.
M&L for galvanised tubing 20 mm med grade with all fittings laid in trenches all as directed by engineer in charge.
Cutting existing steel tubing for alterations or additions 40 or 50 mm all as directed by engineer in charge.
M&L for Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector 40/50 mm bore of pipe complete all as specified and as directed.
M&L for gun metal globe or gate valve with iron wheel head,screwed both ends for iron pipe suitable for20mm bore GI tubing complete all as specified and as directed.
S&F integral LED security light Draco 30W comprising of epoxy powder coated aluminium housing,enclosed with cover in frame suitable for 50/40 mm GI pipe complete with accessories confirming to Cat Part No LTESS30WLED of C&S or of equivalent in wipro/Phillips all as specified and directed.
M/S Sandeep Enterprises
Aishwarya Constructions
RAJKUMAR KISHANCHAND JASWANI
S G Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .