Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹40.4 L+₹3.2 L (8.47%)Rejected-Finance | L2 | Rejected-Finance Higher | |
| 3 | L3₹42.2 L+₹5.0 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Higher |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
31 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
CERTAIN SANCTIONED WORK UNDER AGE B/R II AND AGE E/M UNDER GE NAMS
2020_MES_383309_1
GE NAMS - 64 / 20 - 21
Open Tender
Civil Works
Item Rate
180 days
NAMS CANTT
CLASS D
CATEGORY a i, b i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹90,000
Yes
6 Dec 2020
5 Oct 2020
2 Nov 2020
5 Oct 2020
31 Oct 2020
19 Oct 2020
60 days
Amount
Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/ Loose soil complete all as specified and directed.
Excavating in trenches n. exc 1.5m wide and n exc 1.5m in depth for foundation etc and getting out in soft / hard soil complete all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm complete all as specified and directed.
Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed.
Excavation in post holes (or similar holes) each n. exc. 0.5 cum getting out returning filling in and ramming earth or broken rubble around earth in layer not exceeding 25 cm watering and removing surplus soil to a distance n.exc. 50 m and making good surface in soft /loose soil complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240,nut and bolt complete all as specified and directed
S & F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws with bent to a curve (of any radius as per required) complete all as specified
Supply and fixing pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, in ridges, hips, vally gutter, drip complete all as specified and directed by Engineer-in-charge.
M&L preparation of newly plastered surfaces and applying two coats of Cement base paint of shade as approve over a coat of cement primer on wall.
M&L for brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete incl demolition of brickwork /stone built in cement mortar etc all as specified and directed.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) complete all as specified and directed.
M&L PCC 1:2:4 type B1 (using 20 mm graded stonr aggregete)as in coping,benching foundation filling etc complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 (using 40mm agg.) in plinth protection, path and paving incl demolition and rubbish off the primises all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40 mm agg. ) in sub base of flooring including demolition complete all as specified and directed.
M&L for machine cut precast conctere interlocking power block ISI mark any shape and size of 60 mm thickness M-35 grade including 25mm thick sand cushioning complete all as specified and directed.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings all as specified and directed by Engineer-in-charge.
M&L 25mm thick Cement concrete type B-1, 1:2:4 (12.5mm graded aggregate) including prepration of old surface, scraping, washing, boorming, chipping etc complete all as specified and direct by Engineer-in -charge.
M & L for applying two coat of undiluted thick coat of acrlic reinforcement liquid applied elastorneric water proofing membrane with UV resistance properties and solar refective properties over one coat of primer (Gap between each coat will be 6 hrs. manufacturer certificate is mandatory) complete all as specified and directed by Engineer -in-charge.
M&L for brick work with locally available sub class ‘B’, old size, best quality bricks, in 1/2 brick thick honey comb walling built in cement mortar ( 1:6) including Demolation complete all as specified and directed..
M & L for PCC 1:2:4 Type B-2 (using 20mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as Specified and directed .
S&F for rotational moulded polythene 1000 litres water storage tanks cylindrical vertical with closed top hoisted and fixed in position inclusive 20 mm dia float valve with aluminium fitting. All as specified and directed including old disconnecting and taking down complete all as specified and directed.
S&F for 15 mm bor GI tube medium grade freed to wall or under floor incl taking up or down old tube complete including cutting closes and make good in CM 1:3 complete all as specified and directed.
S& F in repair 20 mm bore G.I tubing in new or old location (wall/Roof) with all fittings incl taking up or down old tube complete all as specified and directed.
S&F 160mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 160mm dia PVC(SWR) bends/shoes complete all as specified and directed.
S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors incl taking down old pipe complete all as specifed and dirtected.
S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm bore screwed down high pressure with crutch or butter fly handle complete all as specified and directed.
S&F 100 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste complete all as specified and directed.
S&F 100 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste complete all as specified and directed.
S&F 100 mm dia CI branch piece single branch of any radius with ovel access door and jointed with neat cement paste complete all as specified and directed.
S&F CI/Soil waste pipe 75mm dia sand cast iron any length with or without ears with cement joint fixed ontrunches / wall complete all as specified and directed.
S&F CI bends75mm dia (any radius) dimenishing pieces of tapers large bore measures fited with oval access door complete all as specified and directed.
M & L for repair to RCC Chajjas, roof projection edges ,hanging part of chajjas, edges of chajjas, RCC papafeets, under the roof / floor slabs with PCC 1:2:4 (using 12.5mm crushed graded agg) incl neccasary form work, MS chicken wire mesh for bounding the concrete on ground required and plaster work in CM 1:3 & periodical services to match with the existing surfaces at any height of buildings etc completed all as specified and directed by Engr-in-Charge.
M&L for preparation of new and previously un-treated steel and iron surfaces of any description, not otherwise described exc 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified
M&L for broken bricks hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed.
Supply and fixing ceiling fan 1200mm sweep copper winding with electronic regulator, Low power consumption, high speed Aluminium body with blade, double ball bearing of BEE star rated Including acessories connector, canopy, Hanging Rod and clamps, including electric connection with pvc flexible twin core copper wire from ceiling rose to ceiling fan complete all as specified and directed.
M&L for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FR unsheathed and multi stranded copper conductor cable in and including new PVC Concealed conduit not less than 20mm dia 1.5mm thick for one fan point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick Hylem sheet top cover, sheet screws and 1.6mm thick GI sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed for the following :- Note : The cost of sunken boxes and bakellite sheet is included in the quoted rate)
Supply and Fixing switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed
Supply and fixing ceiling rose 65X50 mm two to three terminals complete all as specified.
Santokh Singh and Associates
Jaspal Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .