| Sl No | Description | Qty | Unit | V NANDAKUMAR L2 | S ARUMUGAM L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. | 174 | M3 | 286 ₹49,764 Lowest | 286 ₹49,764 Lowest |
| 2.00 | Supplying and filling in foundation, basement, etc with filling Crushed Stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 51 | M3 | 2,072 ₹1,05,672 Lowest | 2,072 ₹1,05,672 Lowest |
| 3.00 | Supplying and filling in foundation, basement, etc with crushed stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 17 | M3 | 500 ₹8,500 Lowest | 500 ₹8,500 Lowest |
| 4.00 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification | 82 | M3 | 131 ₹10,742 Lowest | 131 ₹10,742 Lowest |
| 5.00 | Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification | 17 | M3 | 6,076 ₹1,03,292 Lowest | 6,076 ₹1,03,292 Lowest |
| 6.00 | Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by Manual means | 17 | M3 | 6,076 ₹1,03,292 Lowest | 6,076 ₹1,03,292 Lowest |
| 7.00 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). | 83 | M2 | 780 ₹64,740 Lowest | 780 ₹64,740 Lowest |
| 8.00 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). | 274 | M2 | 1,012 ₹2,77,288 Lowest | 1,012 ₹2,77,288 Lowest |
| 9.00 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c, etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). | 154 | M2 | 2,011 ₹3,09,694 Lowest | 2,011 ₹3,09,694 Lowest |
| 10.00 | Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). | 198 | M2 | 594 ₹1,17,612 Lowest | 594 ₹1,17,612 Lowest |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
19 Aug 2025, 3:00 pmClosed
The Superintending Engineer, PWD.,
O/o. The Superintending Engineer, PWD., Buildings (C and M) Circle-1, Chepauk, Chennai-5
Construction of 3 class room building in Govt. Higher Secondary School at New Alamathi (Model School) in Thiruvallur District
2025_PWD_589389_1
PWD/BCMC1/26-4/2025-26
Open Tender
Civil Works
Lump-sum
120 days
Alamathi
Refer Tender Condition
7 documents required · 7 mandatory
₹0
₹46,000
17 Dec 2025
14 Aug 2025
19 Aug 2025
14 Aug 2025
19 Aug 2025
14 Aug 2025
Amount
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with filling Crushed Stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with crushed stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by Manual means
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c, etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/mᶾ and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
In foundation and basement
In Ground floor
In First Floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)-
Foundation and Basement
Ground Floor
First Floor
Brick work in following Cement Mortar 1:5 using best quality Fly ash bricks of size 230 x110 x 70mm for foundation and basement including curing, etc., complete complying with standard specification.
In Cement Mortar 1:5 (one cement and six sand) Foundation & Basement
Brick work in following Cement Mortar 1:6 using best quality Fly ash bricks of size 230 x110 x 70mm for foundation and basement including curing, etc., complete complying with standard specification.
In Cement Mortar 1:6 (one cement and six sand) for Super Structure in GF
In Cement Mortar 1:6 (one cement and six sand) for Super Structure in FF
Brick partition walls of 7 cm thick using best quality fly ash bricks of size 230x110x70mm in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
In Ground Floor
In First Floor
Plastering with Combination mortar 1:1:6, 20mm thick in all floors etc., complete complying with standard specification and as directed by the departmental officers.
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Using Fine polished Kota Stone Slab above 600 x 600 of 18 / 20mm size
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed. 40mm thick
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
110 mm dia (In building with ground floor only)
Plastering with Cement Mortar 1:5 (One Cement and five Sand) 12mm thick including finsihing, curing, etc., complete in all floors complying with standard specification and as directed.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Supplying and applying of Two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the departmental officers. (The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet) cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete).
Supply and installation of B3 Polyvision Green Ceramics Steel Chalk Writing Board made by AALIANCE N.V.EUROPE, Belgium. On steel core the long lasting porcelian is fused at temperatures upto 8000 C. With this process a scratch and stain resistant surface is created and becomes smooth and crashing free of "Ghost Lines" Virtually maintenance free, this Chalk board never acquires "Chalking in" and total cleaning is accomplished with clear water the writing surface will not crack peel even when solvents are used to remove crayon, paint or other foreign substances. Highly versatile, the entire writing area can become a display board with the help of magnetic buttons. Under ordinary circumstances writing surface will not break like glass boards, so durability can be assured. The boards are made of 0.40mm ceramic on steel writing surface 9mm MDF 0.0mm, GI sheet. The above three materials sandwich with rubber based adhesive and it is framed with heavy anodized aluminium section and chromium plated in corners.
Fabrication, supplying and fixing of Steel door made out of 40 x 40 x 6mm M.S angle section for outer frame and shutter made out of 35 x 35 x 5mm M.S angle section with necessary stiffner 32 x 6 mm flats not exceeding at 30cm intervals and necessary cross diagonal M.S flat of size 32 x 6mm. A tie bar of 32 x 6mm M.S flat is used in bottom of frame in order to avoid twisting of door frame. The shutter frame shall be fully covered by 18 gauge C.R.CA sheet and provided. A tiebar isprovided at the bottom of the outer frame toprrevent twisting of frame during transportationand fixing. All members should be given one costof materials labour charges and all incidentialcharges and fixing charges.
Single Leaf
Double leaves
Manufacturing, Supplying and fixing in position of Steel Windows with the following specifications. Outer frames of Windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 kg / m and mullion 'J' Section (F4B) of size 46 x 25 x 3mm at 2.28 kg/m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419 kg / m as specified in IS 7452 / 1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18 x 5mm MS Flat at 0.70 kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly. 2 Numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18 x 5mm MS Flats are revetted to the shutters at an appropriate height in Window.
Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the Window handle. Each Window shutter having an adjustabloe stay made out of 18 x 5mm at 0.70 kg/m MS Flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the Window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the Window by using MS Flat of 18 x 5mm at 0.70 kg/m welded to the shutter at two place equivalent from each other from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the Window at an equal interval not exceeding 100mm edge to edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS 7452 / 1990. The cost includes cost of all materials, labour charges and other incidental charges, etc., complete.
Three leaves
Manufacturing,supplying and fixing mild steel emergency door of size 1.20mx2.10m made out of MS angle of size [email protected] kg/m for outer frame and MS angle of size [email protected] kg/m for shutter frame to be provided for a height of 0.80 m from bottom. The bottom portion of 0.80x1.20m is to be provided with two openable shutters using 18 gauge CR sheets of best quality. These shutter panels should be stiffenend using MS flats of 18X5mm diagonally. One aldrop is provided at the centre. Each Window shutter having an adjustabloe stay made out of 18 x 5mm at 0.70 kg/m MS Flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the Window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the Window by using MS Flat of 18 x 5mm at 0.70 kg/m welded to the shutter at two place equivalent from each other from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the Window at an equal interval not exceeding 100mm edge to edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officersThe rate including cost of materials, labour, transportation to the site etc., complete and as directed by the Deptl. officers.
Manufacturing, supplying and fixing in positon of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed
Roofing with best quality prelaminated galvanised iron powder coated sheet of 0.47m thick of approved colour design and quality including cost of self tapping screws between washer and cutting the sheet to required slop if found necessary during execution of work have charges for machine etc.,complete.As per approved rate.
Supplying and fixing 50mm dia GI pipe of approved quality and brand including labour charges for fixing etc. complete.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed.
Supplying and painting the walls with two coats of Interior emulsion paint (Including wall putty) as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications
Supplying and painting the walls with two coats of Exterior emulsion paint as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification.
V NANDAKUMAR (BID ID -1432885)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_704933.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .