GM CONTRACTS
CONTRACTS DEPT KIRANDUL
Miscellaneous Electrical Works Contract for CP DH-14, CP DH-11C CP DH-11B for two-Years
2026_NMDC_831146_1
KDL/CTRT/ Misc. Elec. Works/25-26/82
Open Tender
Electrical and Maintenance Works
730 days
NMDC KIRANDUL
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7,900
CONTRACTS DEPT KIRANDUL
3 Mar 2026
3 Mar 2026
30 Mar 2026
3 Mar 2026
30 Mar 2026
3 Mar 2026
13 Mar 2026
Laying,fixing/dressing of PVC/XLPE Insulated, PVC sheathed, Al/Cu Conductor,Ua/Ar Control Cable of 1.1 KV Grade of size not exceeding 3/4C,1.5/2.5 sqmm, in the cable trays/trench/on surface at conveyor gallaries,Motor houses,MCC rooms,cable reeling drums etc
Laying,fixing/dressing of PVC/XLPE Insulated,PVC sheathed, Al/Cu Conductor,Ar Power Cable of 1.1 KV Grade of size not exceeding 3/4C,16 to 50sqmm or 15/19/37C,1.5/2.5sqmm in the cable trays/trench/on surface at conveyor gallaries,Motor houses,MCC rooms, cable reeling drums etc
Laying,fixing/dressing of PVC/XLPE Insulated, PVC sheathed, Al/Cu Conductor,Ar HT(3.3 KV)/LT Power/ Control Cable size not exceeding 3/4C(70 to185 sqmm) in the cable trays/trench/onsurface at conveyor gallaries, Motor houses,MCC rooms,cable reeling drums etc,as required Upto 120 sqmm
Laying of one no.PVC insulated/XLPE HT/LT power cable direct in ground including excavation, sand cushioning, protective covering refilling the trench as required -above 185sqmm and up to 400sqmm.
Terminations of Power & Control cables from 1.5sqmm to 50sqmm in JB's, panel's etc,including ferruling,glanding etc
Terminations of LT/HTPower Cables of 3C/4C from 70sqmm to185sqmm in JB's, panel's etc,including glanding,dressing etc
Transporting of 4C*120 sqmm or higher size LT/HT cable from Stores to the work place in the OCSL plant and shifting the removed cable to the site stores
Earthing with copper earth plate 600x600x3 mm thick including accessories and providing masonary enclosure in cement mortor cover plate having locking arrangement on top and GI watering pipe 20mm dia, 2.7mtr, long so as to obtain proper earth resistance including digging of suitable pit and back filling by adding extra salt, charkol and sand in layers all along the electrode etc. as per in norms
Earthing class B, GI earth pipe 4.5mtr. Long 40mm dia having staggered holes of 10mm dia including accessories and providing masonary enclosure with cover and watering pipe with charcol & salt as per IS standards.
Supply & fixing/laying 25mm x 5mm GI earth strip on surface or recess for connections etc as required for earthing ,including soldering.
Supply and fixing/laying 50x5 sqmm GI earth strip on surface or recess for connections etc as required for earthing, including soldering
Point wiring for light/fan with continuity of circuit using suitable PVC channel case caping system in white colour (Modi/Prestoplast make)confirming to IS standards with inverted wood plugs at interval of 500mm using screws including finishing the damged portion with 1.5sqmm FRLS/PVC insulated,sheathed multistarnd copper of 650V grade with 5 Amps piano type S/P switch fixed on decolem sheet top on suitable wood board coated with two coats of sheelock on all sides leaving sufficient lenghth of loose wires inside the board and terminating the other end on suitable wood round block of 100mm size and ceiling rose. Rates are equal for short/medium/long points with 1.5sqmm PVC insulated copper (Multistrand)for earthing.
Point wiring for 5 pin,5amps multipurpose socket outlet Point with 1.5 sqmm copper multistrand conductor as required on same board along with 1.5sqmm cu wire for earthing,Make of the copper wires:Finolex
Point wiring for 5 pin,15amps multipurpose socket outlet Point with 1.5 sqmm copper multistrand conductor as required on same board along with 1.5sqmm cu wire for earthing,Make of the copper wires:Finolex
Erection & testing of approved make electric ceiling fan in position including fixing of regulator on switch board with required materials
Fixing & termination of new approved make out door 70W/150W/250W/400W wall mounted/street light type Metal Halide /HPSV fitting or as required,with installation supports
Supply,erection,testing and Commissioning of Distribution board with one no 3Phase,63Amps SFU main incoming and provision for 16 nos 20 amps outgoing Double pole MCB 10KA ,230 V (Make for SFU:L&T/Siemens/Havells/Schneider, MCB:Havells/MDS)
Supply, fixing of single pole ISI marked of accepted standard of MCB,6 Amps suitable to 240/220 V,50 HZ, ac supply,with enclousure,for power circuit
Loading/unloading/shifting of Electrical panel from CSD Kirandul/Bacheli to the site Preparation of suitable foundation depending on the site condition,erection of the panel with necessary arrangements,by necessary fabrication and erection of M.S.angular frame
Jointing of HT Cables at end with cable jointing kit Checking of wiring,tightening connections & Terminations of HT cables at both ends
Loading/unloading/shifting of HT Incomer(1+4)/MCC/LT MCC/RC panels from CSD Kirandul to the site; Preparation of suitable founadation depending on the site condition,erection of the panel with necessary arrangements,by necessary fabrication and erection of M.S.angular frame Jointing of HT Cables at end with cable jointing kit checking of wiring,tightening connections & terminations of HT cables at both ends
Dismantling & Shifting of 100 KVA /500KVA power/lighting transformer from control room to CWS, Bacheli/ CSD, Kirandul and shifting of the same to plant after repair and erecting the transformer with necessary foundation
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85mm dia 3 mm thick copper base plate including holes etc. complete as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Making indoor cable end termination with heat shrinkable jointing kit, complete with all accessories including lugs, other jointing material for HT cables. Make:Denson/Mseal/3M/Reychem
Loading/unloading/shifting of Battery set from CSD Kirandul to the site; Preparation of suitable structure depending on the site condition,erection of the battery stand with necessary arrangements by necessary fabrication and erection of M.S.angular frame, wiring, tightening connections & terminations of LT cables at both ends and battery stand including earthing.
Loading/unloading/shifting of Battery Charger panel from CSD Kirandul to the site; Preparation of suitable foundation depending on the site condition,erection of the panel with necessary arrangements, by necessary fabrication and erection of M.S.angular frame, wiring, tightening connections & terminations of LT cables at both ends and earthing.
Installation of 5 kVA to 10 kVA UPS with along with complete battery set including unloading, loading & transportation from CSD Kirandul to the site.
Complete installation of Metal Detector, including erection of control unit, with necessary fabrication
Complete installation/relocation of Weightometer, including erection of control unit, with necessary fabrication.
Erection of VVVF drive panel inclusive of preparation of foundation frame, grouting, etc
Complete installation/relocation of permanent hanging magnet, including fixing of hardware/ chains with necessary fabrication including Loading/unloading/shifting from CSD Kirandul to the site
Replacement of existing 500 KVAR capacitor at CP/DH 14 including unloading, loading & transportation from CSD Kirandul to the site