Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹11.2 L+₹47,350 (4.41%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹12.2 L+₹1.5 L (13.9%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹12.2 L+₹1.5 L (14.1%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹12.3 L+₹1.6 L (14.5%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹33,400
Closing Date
14 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS AT VARIOUS OTM ACCN OF 35 INF BDE SIG COY 227 FD WKSP AND ORs MD ACCN AT YOGENDER VIHAR UNDER AGE E/M (SOUTH) OF GE (SOUTH) DELHI CANTT-10
2021_MES_431218_1
GE/DS-84/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹33,400
Yes
3 Jun 2021
17 Mar 2021
16 Apr 2021
17 Mar 2021
14 Apr 2021
31 Mar 2021
18 Mar 2021 - 29 Mar 2021
60 days
Amount
Attending complaints for checking the existing defective electrical items for continuous electric supply including carrying out minor repair(s) as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repair(s) such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/ internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-in-Charge. Note :- This item is applicable only where no store is required. (i) One electrician and One Helper shall be provided by the contractor for attending daily complaints on working days including holidays/sunday and shall report to MES complaint cell at 8:30 hrs. (ii) Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. (iii) The MES Department is not responsible for the payment of electrician, as all the items of CA are to be supply and fixed by the contractor. (iv) The Contractor will ensure that the team of electricians with necessory tools bag shall always remain present at complaint cell to attend the complaints. (v) A recovery of Rs 500/- per person shall be recovered from the contractor for non deploying of electrician and 300/- per person for helper on any working day. (vi) All the complaint slip,register & other connected document will be provided by the contractor without any extra cost. (vii) Proper record (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produce for verification at the time of payment of each RAR/Bill. (viii) Fixing of item No. 2 to 33 and 36 of BOQ are inclusive with quoted rate of this item.
Supply only in replacement of switch piano flush type 6 Amps SP one way Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of switch piano flush type 6 Amps SP 2-way Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement bell push, flush type 6 Amps Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of switch piano type 16 Amps SP one way Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of lamp holder bakelite insulated body with back plate suitable for batten fitting Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of ceiling rose surface Bakelite 65x25 mm two to three terminals Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of switch socket combination 2-in-1, 5/6 Amps flush type Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of switch socket combination 2-in-1 6 & 16 Amps flush type Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of plug top 15/16 Amps, Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of PVC casing caping of size 20 x 12mm of ISI Mark or as per manufacturer design with all accessories for surface wiring Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of bell Ding dong type 230 volts single phase Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz Complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No. LHKL01160099 of Havells or its equivlent as C&S /CG/Bajaj/Phillips.
Supply only LED Batten, T-5 fitting 20 watt LED, indoor decorative, engineering plastic batten with opal diffuser in replacement of old unsv existing 36 Watt tube light fitting, Complete all as specified and directed by Engineer-in-Charge. Make:- C&S/Havells/Halonix/Philips/CG
Supply only LED Batten, T-5 fitting 10 watt LED, indoor decorative, engineering plastic batten with opal diffuser in replacement of old unsv existing 36 Watt tube light fitting, Complete all as specified and directed by Engineer-in-Charge. Make:- C&S/Havells/Halonix/Philips/CG
Supply only Surface mounting round/square shaped LED downlighter with PDC aluminum housing 6 Watt LED lamp type in replacement of old unsv existing CFL fitting any type from ceiling of stairs/common areas, Complete all as specified and directed by Engineer-in-Charge. Make : Cat part No. LTCRSUR6HPLEDRND/W OF C&S or its equivalent in Bajaj/Philips/CG/Havells.
Supply only in replacement of old unserviceable wall light fixture any type with Wall mounting fitting City-4,Decorative wall light fixture made up of Polycarbonate, of B-22 base including 12 Watt LED Bulb of 6.5K Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of Recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas, and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire Complete all as specified and directed by Engineer-in-Charge.
Supply only LED Building security light fitting 45W on existing bracket in replacement of old unsv existing security light fitting any type Complete all as specified and directed by Engineer-in-Charge. Make:- Cat Part No LTESSI45WLED/LS of C&S or its equivalent as Havells/CG/Bajaj/Phillips).
Supply only in replacement of Circuler Hylam/PVC Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core Red/ Blue/ Yellow/ Black Colour for any type of wiring as per site requirement Complete all as specified and directed by Engineer-in-Charge. Make : Polycab/Havells/Finolex
Supply only in replacement of PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core Red/ Blue/ Yellow/ Black Colour for any type of wiring as per site requirement complete all as specified and directed by Engineer-in-Charge. Make : Polycab/Havells/Finolex
Supply only in replacement of PVC insulated FRLS 3 core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement Complete all as specified and directed by Engineer-in-Charge. Make : Polycab/Havells/Finolex
Supply only in replacement of clamp with rubber real for hanging ceiling fans of 1200/1400mm sweep as per sample Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of MCCB 3 pole, 415V, Adjustable type,125 Amps with breaking capacity 36KA Complete all as specified and directed by Engineer-in-Charge. (Make : Legrand/ABB/Crabtree).
Supply only in replacement of MCCB 3 pole 160 Amps 415 Volts with breaking capacity 36 KA, Complete all as specified and directed by Engineer-in-Charge. (Make : Legrand/ABB/Crabtree)
Supply only in replacement for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement for MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement for MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of MCB TPN 63 Amps 415 volts, C' Series 10 KA as per site requirement Complete all as specified and directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, with OBD/ Colour wash White wash as the existing finish Complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in and including concealed PVC conduit medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly Complete all as specified and directed by Engineer-in-charge. for following : Note:-(I) the rate is inclusive cutting /chasing and making good the disturbed surface with cm 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash (ii) In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbow/tee junctoin box etc .
One light / fan/bell point controlled by one way switch.
One 3 pin socket outlet 5/6 Amps on same board.
One socket outlet 5/6 Amps on independent board.
One power socket 15/16 Amp but with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
Supply only in replacement of MS fastner bolt 8mm dia and 100mm (Min.) long for fixing geyser/ Exhaust fan/Bldg security light etc with nut and washer Complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia Complete all as specified and directed by Engineer-in-Charge. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L for replacement of submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit Complete all as specified and directed by Engineer-in-Charge. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Earthing complete with galvanised earth plate electrode 60 cmx 60 cmx 6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5M below normal ground level connected to GI wire 4mm as earthing lead by means of nut,bolts and check nut and washer,GI light grade protection pipe 15 mm dia. upto 7.5 m,GI watering pipe 20 mm dia,RCC cover with funnel,excavation in any type of soil,PCC pit charcoal ,salt all as shown in electrical plate No 3 of SSR Part I, including earth test point up to pannel board, including testing on completion, complete all as specified and directed by Engr-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Chaudhary Constructions
verma enterprises
Balaji Constructions
Microsys Controls India
M/S Ashoka Engineers and contractors
M/S.M.S.Devi.Const.Co
M/s Prakash Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .