Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.4 L+₹4,400 (0.18%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹26.7 L+₹2.3 L (9.38%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹26.9 L+₹2.6 L (10.5%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹27.6 L+₹3.2 L (13.2%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Jun 2025, 6:00 pmClosed
GE NAMS
GE NAMS Amritsar
DAY TO DAY COMPLAINTS OF STREET LIGHTS, REPAIR/ REPLACEMENT LT STREET LIGHT PANEL, LT DISTRIBUTION CABLES FOR STREET/ SECURITY LIGHT WITH ALLIED WORKS IN OTM ACCN OF FLAMING ARROW BDE AT NAMS
2025_MES_707567_1
GE NAMS-23/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE NAMS
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹90,000
8 Jul 2025
9 May 2025
13 Jun 2025
9 May 2025
6 Jun 2025
23 May 2025
Amount
Attending of Day to day street security Light complaints pertaining to street/security lights recived through telephone or in person or online or detailment at MES Service center located at NAMS Area by locating and rectification of fault from and including junction box /light bracket in respect of electric connections including provisioning of small pieces of service wire of size 1.5 sqmm single core copper conductor and length not increasing 0.50 mtrs and carrying out repairs to the extent of tightening of loose connections,disconnection and dismantling of faulty wires,and removal of carbon deposition including providing necessary screws/nuts/bolts/nails for the rectification of defect and refixing of existing dismantled serviceable items complete all as specified and directed. Note: (i) if complaint warrants replacement of material as catered in BOQ here -in-after shall be paid under relevent item and no measurement shall be done under this item. Rate of attending complaint shall be considered to be quoted in the respective item.
(ii) Necessary tools for tradesman shall be provided by the contractor. (iii) Transportation for tradesman and normal stores required for complaints shall be arranged by the Contractor. (iv) Complaints of normal nature shall be attended and rectified within 8 Hrs of receipt of complaints of emergent nature i.e. no light, short circuit, earth fault etc shall be attended immediately on receipt of complaint round the clock. (v) Contractor or his rep. will report to AGE E/M complaint cell at 9 O' Clock daily for collecting of complaints. Complaint received will be done in the same day and after completion of complaint he will report to complaint cell to submit the complaint slip duly signed by the user. Done on Holidays /Sunday. (vi) For Non attending of complaint within above mentioned time a penalty of RS 100.00 /per day/per complaint will be leived on contractor. This penality shall also be applicable to all the items mentioned in BOQ here -in-after.
Supply & fixing LED street light 60 W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing. Powder coated pressure die cast aluminium housing , IP-65/66 protection, high power LED street light with the heat resistant thoughened glass lens and making electrical connections pvc insulated sheathed 3 core 1.5 sqmm copper conductor from street light to junction box complete all as specified and as directed. Notes:- Driver shall be potted antivibration type. LM-79 and LM-80 for 50000 burning hours. CRI(colour Rendring Index) of fixture shall be ≥ 70. CCT (colour correlated Temp) of fixture shall be 5700K±300K. System Lumen Efficiency shall be>100 Lm/W. 10 KV separate Surge protection shall be provided as a part of fitting. PCB used shall be MC PCB type. The fitting shall have arrangement so that maintenance required , if any can be carried out from Top cover.
Supply & fixing LED street light 70W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing. Powder coated pressure die cast aluminium housing , IP-65/66 protection, high power LED street light with the heat resistant thoughened glass lens and making electrical connections pvc insulated sheathed 3 core 1.5 sqmm copper conductor from street light to junction box complete all as specified and as directed. Notes:- Driver shall be potted antivibration type. LM-79 and LM-80 for 50000 burning hours. CRI(colour Rendring Index) of fixture shall be ≥ 70. CCT (colour correlated Temp) of fixture shall be 5700K±300K. System Lumen Efficiency shall be>100 Lm/W. 10 KV separate Surge protection shall be provided as a part of fitting. PCB used shall be MC PCB type. The fitting shall have arrangement so that maintenance required , if any can be carried out from Top cover.
Supply & fixing LED street light 90 W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing. Powder coated pressure die cast aluminium housing , IP-65/66 protection, high power LED street light with the heat resistant thoughened glass lens and making electrical connections pvc insulated sheathed 3 core 1.5 sqmm copper conductor from street light to junction box complete all as specified and as directed. Notes:- Driver shall be potted antivibration type. LM-79 and LM-80 for 50000 burning hours. CRI(colour Rendring Index) of fixture shall be ≥ 70. CCT (colour correlated Temp) of fixture shall be 5700K±300K. System Lumen Efficiency shall be>100 Lm/W. 10 KV separate Surge protection shall be provided as a part of fitting. PCB used shall be MC PCB type. The fitting shall have arrangement so that maintenance required , if any can be carried out from Top cover.
Supply and laying, in replacement, of LT underground cable XLPE insulated, inner PVC sheathed, galvanized steel strip armoured, PVC sheathed electric power cable with stranded compact aluminium conductor 1100 volts grade 25 Sq mm 4 core confirming to IS:7098 (Part-I) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc . Note : 1. The cost of Aluminium thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, DWC protection pipe will be measured and paid separately under respective items.
Ditto As per item no 5.00 but for 50 sqmm , 3.5 core complete all as specified and directed.
Ditto As per Item No 5.00 but 16 Sqmm, 4 core complete all as specified and directed.
Ditto As per Item No 5.00 but 10 Sqmm, 4 core complete all as specified and directed.
Excavation in trenches in any type of soil by not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth below ground level for foundation of poles/ stays/cable and getting out complete all as specified and directed.
Returning, filling in, any type of soil and spreading in layers not exceeding 25cm thick each layer including watering & well ramming complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed.
Labour for drilling hole under the road with the help of drilling machine without damaging the road horizontally for rod crossing including laying GI tubing of any size for cable protection complete all as sp an directed and directed.
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge.of size75 mm outer dia and 61 mm inner dia complete all as specified and directed.
Supply and fixing in replacement FR grade thermoplastic polyethylene outdoor cable junction box hinged/screwed door type of size 200x160x 98 mm for 3 Phase and Nutral incoming cable, 3 Phase and Neutral outgoing cable with terminals/connectors and single Phase & Neutral connection for light fitting, 4 pole, 415 volt and one MCB SP 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-66, weather proof, rust, dust and water proof internally embedded gasket with provision metric knockouts for cable entry through gland suitable for 16sq mm to 25sq mm cable as required at site complete all as specified & directed.
Material & labour for painting of steel / PCC poles with two coats of synthetic enamel paint in black and white strip 30 cm wide each up to 1.5 mtr height from coping over a coat of primer including numbering of poles complete all as specified and directed.
Supply and fixing micro prismatic reftective sheet, minimum 50 mm wide, with adhesive base for dirtectly fixing on HT/LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour complete all as specified and directed.
Supply and fixing in replacement 1100 volts grade heavy duty cabel PVC insulated aluminium conductor , served with inner sheating of PVC tape and overall PVC sheated in service connection suspendede twin core cable flat or circular size 4 Sqmm complete all as specified and directed.
Ditto As per S Item No 17.00 but 6 Sqmm, 2 core complete all as specified and directed.
Ditto As per S Item No 17.00 but 10 Sqmm, 2 core complete all as specified and directed.
Supply and fixing / laying in replacement galvanized iron pipe of 40 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed.
M&L fabricating and fixing in replacement of cross arms (any type) supports, brackting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil and connecting to earth up to 6 meter length complete all as shown in electrical plate no 3 of SSR PART 1 , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified & testing on completion.
Supply and fix in replacement Timelite distribution boards of Timelite 63 Amps 3 pole 230 Volt Digital time switch for out door use, weather and vermin proof duly painted with synthetic enamel paint made out of 3.15mm thick CRCA sheet with locking arrangement comprising of one number time switch 24 hours operation Accuracy: quartz time base +/- 1 S per day, Power contractor 63 Amp , MCCB 4 pole of suitable size,manual switch and indicator suitable for street light operation and duly fixed on pole with clamps / Grouting on ground complete all as specified and directed.
Supply and fix in replacement Timelite distribution boards of Timelite 40 Amps 3 pole 230 Volt Digital time switch for out door use, weather and vermin proof duly painted with synthetic enamel paint made out of 3.15mm thick CRCA sheet with locking arrangement comprising of one number time switch 24 hours operation Accuracy: quartz time base +/- 1 S per day, Power contractor 40 Amp , MCCB 4 pole of suitable size,manual switch and indicator suitable for street light operation and duly fixed on pole with clamps / Grouting on ground complete all as specified and directed.
Supply and fixing inreplacement street light mounting bracket made out of GI pipe 40 mm dia light Grade not less than with 1.5 (90cmx60cm) mtr long in any shape including clamps, nuts, bolts, washers etc and painting with aluminium paint, complete all as specified and direced
Supply and fix of MCB 40 Amps , 4 pole , 415 volts, 10 KA complete all as specified and directed.
Supply and fix of MCB 40 Amps single pole with neutral, AC 230 Volts complete all as specified and directed.
Supply & Fixing MCB single pole, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type complete all as specified and directed.
Supply and fix of MCBs single pole (SP) 16 to 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards complete all as specified and directed.
Supply and fix Power contractor 3 pole, 415 volts, 40 Amps , C1 Series of current rated 40 Amps complete all as specified and directed.
Supply and Fix Digital time switch programmable every 1 minutes with back up of 6 years, 28 memory locations , current capacity 16 A weekly program, with 1 changover (1 CO), total 28 programme suitable for existing new switches as specified and directed.
Supply and Fix in replacement of LED type street light Drivers suitable for 120 watt light of Operating Voltage 140-270 Volts, PF (0.95)LED driver current > 700 mA, suitable for existing size and make to functional the fitting LED complete all as specified and directed.
All as per ser item No 32.00 above but LED Street light driver suitable for 90 Watt light complete all as specified and directed.
All as per ser item No 32.00 above but LED Street light driver suitable for 60 Watt light complete all as specified and directed.
All as per ser item No 32.00 above but LED Street light driver suitable for 45 Watt light complete all as specified and directed.
All as per ser item No 32.00 above but LED Street light driver suitable for 25/35 Watt light complete all as specified and directed.
M & L in replacement of MCCB Capacity 100 Amp 25 KA 4 pole adjustable thermal megnate release type with preader and aluminium lugs complete all as specified and directed.
Supply & fixing in replacement shackle/Pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, including removal of existing insulators complete all as specified and directed.
Supply & Fix in replacement flood Light Luminaire 200 watt with .high power LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast polycarbonate,powder coated in IP 66 life of 50000 hrs.Incliding protection of O/C,S/C,O/V, over temperature and lightning protection inbuilt complete all as specified and directed .
Supply & Fix in replacement flood Light Luminaire 150 watt with .high power LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast polycarbonate,powder coated in IP 66 life of 50000 hrs.Incliding protection of O/C,S/C,O/V, over temperature and lightning protection inbuilt complete all as specified and directed.
Supply & Fix in replacement flood Light Luminaire 80 watt with .high power LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast polycarbonate,powder coated in IP 66 life of 50000 hrs.Incliding protection of O/C,S/C,O/V, over temperature and lightning protection inbuilt complete all as specified and directed.
Supply and fixing in replacement PVC insulated, PVC sheathed, multistranded copper conductor wire 1.5 Sqmm size, twin core complete all as specified and directed.
Supply and fix in replacement of MCB Isolator 32 amp- 63 Amp complete all as specified and directed.
Material & labour for painting to steel pole including mild steel supports, clamps etc fixed on LT Poles any height with providing two coats of aluminium pant over a coat one coat of red oxide primer in and including wriitng pole number with black paint complete all as specified and directed. Note:- Steel members fixed on single LT pole shall be considered as 'One Unit'.
Material and labour in replacement for ACSR conductor any size drawn stright horizontal on LT over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent LT poles and calculating weight of conductor of size lenght by adding 3% extra for sag, jointing , jumpers etc complete all as specified and directed.
Supply and fixing of straight through joint heat sinkable suitable for 10 sqmm to 50 sqmm LT 3.5 core 1100 volts XLPE complete all as specified and directed.
Taking out existing U/S faulty LT cable of any size, detecting the fault and relaying after repair complete all as specified and directed. Note : (i) The cost of Aluminium thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. (ii) Excavation, earth work, DWC protection pipe will be measured and paid separately under respective items.
Repair/maint of high mast pole,checking of control panel, motor stater, control wiring, gear box, switches for Up / down travel light frame,rope and gear box etc including oiling, greasing, welding of shaft etc complete if required complete all as specified and directed.
Supply and fix in replacement of steel wire rope 6 mm dia complete all as specified and directed.
Taking out electric motor 1.0 HP 3 Phase 415 V dismantling , taking out burnt winding wire and rewinding with new supper enameld copper wire baking, vernishing etc and reassembling testing complete all as specified and directed.
Supply and fix in replacement of bearing suitable for 1.0 HP 3 Phase 415 V motor complete all as specified and directed.
Supply and fix in replacement of irreversible DOL motor starter 3 Phase 415V relay range 2.0 to 3.0 Amp suitable for 1.0 to 1.5 HP motor complete all as specified and directed
Supply and installation of dip galvanised octagonal poles 9 m long top dia (A/F) 70 mm bottom dia (A/F) -minimum 130 mm having thickness 3 mm base plate 200 mm x 200 m x 16 mm(LxBxT) including bolt size 4 x 20 mm (Nox dia) , 200 mm pitch circle dia 600 mm bolt length , 100 mm projected bolt length having door opening of sizes 90 x 500 mm above GL and having hot dip galvanized singlr arm plane arm bracket 1000 mm long for pole having top 70 mm A/F for mounting street light fitting fixed on top with nut bolts washers including provision of cable connector for three phases supply and one No MCB SP of 0.5 A to 6A complete alongwith necessary iron work all as specified by manufacturer.
kailu construction co (BID ID -3309451)
Bharat Builder (BID ID -3315373)
Santokh Singh and Associates (BID ID -3309211)
Raman Electric Trading Co (BID ID -3306107)
CHINAR ENGINEERS AND BUULDERS (BID ID -3314897)
M/S BALWINDER SINGH (BID ID -3304936)
PAWAN KUMAR GOVT. CONTRACTORS (BID ID -3309328)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .