| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹48.8 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹58.7 L+₹9.6 L (19.5%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | 2 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
10 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
PROVISION OF RCC BLOCK FOUNDATION AND CONSTRUCTION OF CONTROL ROOM ELECTRO DYNAMIC SHAKER SYSTEM AT 0408 BUILDING UNDER GE I RND RCI HYDERABAD
2022_MES_499293_2
8664
Open Tender
Civil Works
Item Rate
240 days
GE(I) R AND D RCI
MES enlisted Class D category a i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT.
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹97,000
Yes
25 Jul 2022
17 Feb 2022
14 Mar 2022
17 Feb 2022
10 Mar 2022
24 Feb 2022
60 days
Amount
Demolition of PCC in ground floors and paving's not exceeding 15cm thickness (below or above ground level) complete including disposal of debris off the premises all as directed by Engineer in Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., and getting out in soft disintegrated rock including disposal of soil to a distance not exceeding 50m complete all as directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., and getting out in any type of soil including disposal of soil to a distance not exceeding 50m complete all as directed.
Excavation in over areas, not exceeding 1.5m deep and getting out in any type of soil including disposal of soil to a distance not exceeding 50m complete all as directed.
All as per Sl item No 5 above but depth exceeding 1.5m and not exceeding 3.0m.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated material/soil to a distance exceeding 500mm and not exceeding 1000m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L, hardcore broken stone of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Excavation in post holes (or similar holes) each not exceeding 0.5Cum, getting out, in soft disintegrated rock including returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed.
M&L, PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L, PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L, brickwork with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L, 15mm thick rendering in cement mortar 1:4, on other than fair faces of brick or concrete surfaces, in any height, finished even and smooth without using extra cement complete all as specified and directed.
M&L, 10mm thick rendering in cement mortar 1:6, on fair faces of brick or concrete surfaces, in any height, finished even and smooth without using extra cement complete all as specified and directed.
M&L, preparing newly plastered surfaces of walls and ceilings and applying two coats of distemper oil emulsion, white or tinted over coat of alkali resistant primer over a coat of 1mm thick wall care putty including rubbing/ grinding with sand paper and making smooth and even surface as per manufacturers instructions complete all as specified and as directed.
M&L, PCC 1:2:4, type B-0 using 12.5mm graded stone aggregate as in roof curbs, coping and platform to water tanks and the like including necessary formwork, weathering, slightly rounded or chamfered angles and throating and other similar works complete all as specified and directed.
S&F, powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., fabricated complete to receive sheet glass and prelaminated particle board complete all as specified and as directed.
S&F, powder coated aluminium sliding window shutters with aluminium section weighing not less than 0.55Kg/m including necessary joining cleats, glazing clips, anodized aluminum snap beading, screws, handles and suitable locking arrangement for window shutters etc., complete all as specified and as directed. Note for item No 18 & 19: Minimum thickness of powder coating shall be 50microns.
S&F, 4.8mm thick sheet glass, tinted, ordinary quality, square or rectangle, area exceeding 0.5sqm in each pane and fixed to aluminium frame work complete all as specified and as directed.
S&F, standard EPDM rubber gasket for fixing of glass in partitions, doors or windows or ventilators complete all as specified and directed.
M&L, 12mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination, fixed to aluminium framework complete all as specified and as directed.
S&F, 8mm thick Toughened glass, tinted, area exceeding 0.5sqm in each pane and fixed to aluminium frame work complete all as specified and as directed.
S&F, Roof trusses (framed), trussed, purlins, crane gantries rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe 410W (Grade E-250) quality 'A' complete all as specified and directed.
S&F, Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails; fixed with angle cleats or other connecting plates including drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts) conforming to Fe 410W (Grade E-250) quality 'A' complete all as specified and directed.
S&F, Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410W (Grade E-250) quality 'A' complete all as specified and directed.
S&F, mild steel framed work such as grills, gratings etc., with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars; railings and similar works conforming to Fe 290 Gde-E-165 complete all as specified and as directed.
S&F, Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet / trapezoidal steel sheet 0.50mm base metal thickness of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screws and EPDM washers complete all as specified and directed.
M&L, preparation of new steel surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
S&F, metallic fibre acoustical suspended ceiling system with Mina Tuff (Micro look) edge tiles with silhouette exposed grid. The tiles hold have humidity resistance (RH) of 99%, NRC upto 0.6, light reflectance 88%, Thermal conductivity K=0.052-0.057 w/m K, colour white, fire performance Class-I (BS476 Part 6 & 7) in module size of 600 x 600 x 16mm with bio black coating on the face of the tile, impact resistant and suitable for green building application, with recycled content of 63%, Tile shall be laid on Silhouette profile grid system with 15mm white/black colour and with a web height of 38mm and having load carrying capacity of minimum 11.68 Kgs/Sqm, Silhouette, Main runner and Cross tees to have mitred ends and Birds mouth notches to provided mitred cruciform junction complete all as specified and directed. Make: Armstrong, Saint Gobain
M&L, 200mm thick PCC 1:4:8 type D-2 in sub base using 20mm graded stone aggregate finishing the surface even and rough including necessary formwork complete all as specified and directed.
M&L, 100mm thick PCC 1:4:8 type D-2 in sub base using 20mm graded stone aggregate finishing the surface even and rough including necessary formwork complete all as specified and directed.
M&L, 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in flooring, finishing the surface even and smooth using extra cement including necessary formwork complete all as specified and directed.
M&L, double charged coloured vitrified tiles in floors of size 600 x 600 x 9 to 10mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including screed bed or bedding layer 15mm thick in CM 1:4 complete all as specified and as directed complete all as specified and as directed. Note: Shade and design/pattern of tiles shall be as directed by GE.
M&L, 9 to 10mm thick coloured vitrified tiles in skirting of size 600 x 100mm, set and jointed in neat cement slurry and pointed in coloured cement to match shade of tile over and including 10mm thick backing coat in CM 1:3 complete all as specified and as directed.
M&L, RCC M-40 Design mix using 20mm graded stone aggregate as in foundations including footings, foundations beams, plinth beams etc., and mass concrete complete all as specified and directed.
Use and removal of steel formwork to sides of concrete foundation, footings, bases of column, raft and raft beams, sides and soffits of foundation (if any) and plinth beams for fair finished surfaces of concrete, flat, vertical or to batter complete all as specified and as directed.
M&L, TMT bars 10mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
S&F, 50mm thick pre formed bituminous filler board complete all as specified and directed.
M&L, preparation of newly plastered surfaces of walls including cornices, pilasters, soffits of slabs and chajjas and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Forming embankments including raising (or lowering) earth, spreading in layers not exceeding, 30cm thick, watering, ramming /rolling and finishing to required size, shape, not exceeding 1.5m high from base complete all as specified and directed. Note: 1. Rate quoted shall include the cost of moorum brought from outside MD land including payment of royalty, transportation to site by any means and depositing for filling as required. 2. Payment shall be made for solid quantity arrived after consolidation.
M&L, Point wiring complete with FRLSH PVC insulated unsheathed cable 1100V grade conforming to IS-694, 1.5 Sqmm (nominal area) multistranded with copper conductor drawn through and including PVC casing and capping, medium grade, of minimum width 20mm (ISI marked) and accessories fixed to surface of walls/roof/ceiling with PVC sleeve/dash fastener and cadmium plated screws etc., with and including modular metal flush boxes made out of 1.6mm mild steel sheet with modular plate and frame for mounting of switches, socket outlets, regulators etc., complete including provision of FRLSH PVC insulated unsheathed 1.5Sqmm solid copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for the following:- Note: Quoted rate shall be deemed to include cost of Modular flush boxes, cover plate and frame.
One light/fan point controlled by one, one way switch, 5/6 Amps
One socket outlet, 3 pin, 5/6Amps, controlled by one way switch on same board with other switches.
One socket outlet, 3 pin, 5/6Amps, on independent board controlled by one way switch.
All as per item No. 42 above but with 2.5Sqmm FRLSH cable for 5pin 15Amps socket outlet on independent board and 2.5Sqmm FRLS cable for the earth continuity conductor
S&F, Modular Switch 1 way 6Amps, 1 Module, 240V, ISI Marked complete all as specified and directed
S&F, Modular Switch 1 way 16Amps, 1 Module, 240V, ISI Marked complete all as specified and directed.
S&F, Modular Socket, 6Amps - 2/3 pin combined, 2 Module, ISI Marked complete all as specified and directed.
S&F, Modular Socket, 6/16Amps - 2/3 pin combined, 2 Module, ISI Marked complete all as specified and directed.
S&F, Ceiling rose, surface type Bakelite, three terminal 65x50mm, ISI marked complete all as specified and directed.
M&L, Sub main wiring with 2runs of single core 4Sqmm 1100 Volts grade, FRLSH PVC insulated, unsheathed cable, copper conductor, multistranded drawn through and including PVC casing and capping, medium grade, of minimum width 20mm (ISI marked) along with accessories fixed on walls/roofs/floors etc, including provision of FRLSH PVC insulated 4sqmm copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
M&L, Sub main wiring with 2runs of single core 6Sqmm 1100 Volts grade, FRLSH PVC insulated, unsheathed cable, copper conductor, multistranded drawn through and including PVC casing and capping, medium grade, of minimum width 20mm (ISI marked) along with accessories fixed on walls/roofs/floors etc, including provision of FRLSH PVC insulated 6sqmm copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note for item No 49 & 50: Two runs of cable, one run of earth continuity conductor and one run of PVC casing and capping shall be measured as unit length.
S&F, recess mounting 36W LED luminaire suitable for Armstrong/Grid ceiling with high performance LEDs complete with all accessories including driver pre-wired complete all as specified. Make: Havells Cat No: VENUSNEOHE2X2R18-42WLED857 MODUGR<19 along with Driver LEDDRIVER36V1A42WS or Philips CAT No RC 380 B LED 43 S-6500 G5 L60 W60 PSU OD or Techno commercially equivalent in Wipro
S&F, MCB, SPN, 40 to 63Amps, 10KA, 240volts, ISI marked complete all as specified and directed. Make: Legrand Cat No 4086 18 to 4086 20 or equivalent in Siemens / L&T / Schneider/ C&S as approved by GE
S&F, MCB, SP, 6 to 32Amps, 10KA, 240volts, ISI marked complete all as specified and directed. Make: Legrand Cat No 4085 87 to 4085 95 or equivalent in Siemens / L&T / Schneider/C&S as approved by GE
S&F, factory made sheet metal enclosure distribution board (MCB DB) SPN 8Way, with 100amps rated copper bus bar, neutral link and earth bar, metal door, powder coated, suitable for use on 240V, 50Hz supply, IP 43 IK 09 protection, MCBs used as out going, making good disturbed surfaces to match with existing complete all as specified and directed. Make: Legrand CAT No 5076 11 or equivalent in L&T/ Siemens/ Schneider/C&S as approved by GE
S&F, factory made sheet metal enclosure distribution board (MCB DB) SPN 4Way, with 100amps rated copper bus bar, neutral link and earth bar, metal door, powder coated, suitable for use on 240V, 50Hz supply, IP 43 IK 09 protection, MCBs used as out going, making good disturbed surfaces to match with existing complete all as specified and directed. Make: Legrand CAT No 5076 10 or equivalent in L&T/ Siemens/ Schneider/C&S as approved by GE
S&F, Modular Telephone socket RJ 11 with shutter, 1 module including modular flush box with cover plate and frame complete all as specified and directed.
S&F, Modular RJ45 Computer Socket (Cat6), 1 Module including modular flush box with cover plate and frame complete all as specified and directed.
S&F, 32mm dia non metallic rigid PVC conduit ISI marked including cutting chases not exceeding 10cm girth to brick walls for concealed conduit and making good cutting in cement mortar 1:3 complete all as directed.
S&F, Earth continuity conductor with 20 x 3mm copper strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed.
M&L, Maintenance free chemical earthing consisting of earth electrode of high tensile low carbon copper bonded steel rod 17.2mm dia 3000mm length, outer surface of electrode shall be molecularly bonded with copper having thickness of 250microns, electrode shall be placed in an mechanized augured hole and backfilled with 30Kg carbon based conductive concrete type compound which has a resistivity of less than 0.12 Ohm metre as per clause 14.5D of IEEE:80 standard including 17.2mm tin coated brass clamps both sides, the pit shall be installed with a manhole with top cover including laying of 25 x 3mm copper strip from the earth pit to panel/equipment upto 7.5m using 40mm dia medium grade GI protection pipe buried in ground from earth pit to building equipment, measurement of earth resistance and providing test reports complete all as directed.
Notes: The unit rate shall also include for earth work in any type of soil, suitable HDPE earth pit cover, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 40mm dia and wire mesh complete in addition to item No. 1(a) & (c) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 446 of SSR Part-II.
The earth resistance value for each location should be less than 1 Ohm and shall be measured, calibrated with earth resistance megger and same shall be certified by concerned user department.
The Earth pit shall be numbered as per the work center and named on the earth pit using bituminous paint all as directed.
S&F, porcelain/epoxy, white / brown / green spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding or fixing roof / down conductor of lightning complete all as specified and directed
S&F, Brushless direct current motor (BLDC) ceiling fan, 1200mm sweep with blades, down rods, electronic regulator and accessories, 230V, minimum air delivery 210CFM with service value 6.00BEE, five star rated complete all as specified and directed. Make: Havells, Crompton Greaves, Usha, Orient
M/S GDR CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .