Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹14.5 L+₹1.5 L (11.4%)Rejected-AOC 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 3 | L3₹17.5 L+₹4.5 L (34.2%)Rejected-AOC | L3 | Rejected-AOC REJECTED DUE TO NOT LOWEST |
Tender Value
₹18.5 L
EMD Value
₹37,100
Closing Date
15 Mar 2021, 6:00 pmClosed
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
MAINTENANCE, REPAIR AND REPLACEMENT OF DEFECTIVE ITEMS OF INTERNAL ELECTRIFICATION AND MISC ITEMS IN OMQ, NP AREA AND TECH AREA AT AF STN PUNE.
2021_MES_422986_1
8440/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹37,100
Yes
20 Apr 2021
17 Feb 2021
17 Mar 2021
17 Feb 2021
15 Mar 2021
3 Mar 2021
Amount
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc complete all as specified and directed.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc complete all as specified and directed.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and directed.
One light point controlled by one switch .
One Fan point controlled by one regulator/switch.
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A on the same switch board.
One bell point controlled by one bell switch.
One light point controlled by two way switch
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing one 15 A Switch / sockets complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete drawn in PVC conduit with all accessories and open recessed type plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) concealed in wall or surface for housing switches/sockets complete all as specified & directed
One light point controlled by one switch .
One Fan point controlled by one regulator/switch.
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A on the same switch board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVC insulated 1100 volts grade wire for continuous earthing complete drawn in PVC conduit with all accessories and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) concealed in wall or surfae for housing one 15 A Switch / sockets complete all as specified and directed.
M&L for Sub main wiring complete with 2x2.5 sq mm, single core multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 volts grade, drawn in existing concealed/surface conduit (as required) along walls roofs etc including 2.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth doly : Note :- All three wire/cable (Phase, Neutral and earth) should be run through for each individual circuit from the BDb painting over surface conduit to be done to match with walls . (Note - Two run of cable and earth conductor be measured as one length)
Ditto all as per Srl Item No 8.00 above but 2x4 sq mm and 1x4.0 sq mm for earth wire complete all as specified and directed.
M&L for wiring complete with two runs of 1.5 sq mm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 V grade conforming to IS 694 drawn through steel ERW conduit flame proof, heavy grade ISI marked including nessay conduit accessories surface on wall, ceiling etc including 1.5 sq mm PVC insulated flame retardent copper conductor as in continous earth wire for one FLP light/fan point controlled one way metal clad switch of 5 Amps capacity complete all as specified & directed.
M&L for wiring complete with two runs of 2.5 sq mm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 V grade conforming to IS 694 drawn through steel ERW conduit flame proof, heavy grade ISI marked including nessay conduit accessories surface on wall, ceiling etc including 2.5 sq mm PVC insulated flame retardent copper conductor as in continous earth wire for one 3 pin socket 16 A on independent board complete all as specified & directed.
M&L for sub main wiring complete with two runs of single core 4 sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4 sqmm single Flame retardan PVC insulated unshedthed multi stranded copper conducator green colour cable for continuous earthing complete in & including PVC casing & caping with all fitting & fixtures complete all as specified and directed. ( Note: Two runs of 4 sqmm copper cable and one run of 4 sqm copper cable including PVC casing & caping shall be measured and paid as one length).
M&L for sub main wiring complete with two runs of single core 6 sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6 sqmm single Flame retardan PVC insulated unshedthed multi stranded copper conducator green colour cable for continuous earthing complete in & including PVC casing & caping with all fitting & fixtures complete all as specified and directed. ( Note: Two runs of 6 sqmm copper cable and one run of 6 sqm copper cable including PVC casing & caping shall be measured and paid as one length).
Supply and fix switch piano flush type 5 Amp one way. complete all as specified & directed
S&F Switch flame proof rotary type with termination box in LM6 , 16A single pole 250 V complet all as specified & directed.
S&F switch piano flush type 5 Amp two way complet all as specified & directed.
Supply and fix switch Socket combination outlet 2 in 1 3 pin 5 amps flush type complete all as specified & diected.
Supply and fix socket outlet 2 in 1, 3 pin ,5 A flush type complete all as specified & diected.
S&F Flame proof switch socket & plg combined in LM6 cable terminaton box in LM6 16A 250V 2P+earth
Supply only switch piano, flush button type , single pole, one way 15 amps complete all as specified and directed.
Supply only socket outlet 2in1, 3, 5 and 15 amps, flush type complete all as specified and directed.
Supply & Fix switch Socket combination 3 pin 16 Amps flush type complete all as specified and directed.
Supply and fix Piano switch bell push type switch 5 A complete all as specified and directed.
Supply and fix bell electric 230V single pole complete all as specified and directed.
S & F Fan Regulator electronic step type 230V, 100 W complete all as specified and directed.
S&F angle / batten holder insulated body with back plate for batten fittings complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm complete all as specified and directed.
S&F Fluorescent tubelight fitting 1x36 w flameproof type FLP WP made of aluminium alloy LM6 with electronic ballast bipin holders, connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified & directed.
Supply and fix high quality indoor Surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal. Make : Havells, Model: Lumiline Plus LED Cat part No: LUMILINEPLUSBS20WLED865SPCSS or equivalent in CG/Philips/Bajaj
Supply and fixing LED mirror light fitting 05 Watt, including electrical connections complete as directed.
Supply and fix Energy efficient recess mounted LED panel fitting 34 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 3300/4000K colour temperature with current electronic connections complete all as specified and directed. Make: Havells, Model: Venus Neo HE PRI Cat part No: VENUSNEOHE2X2R34WLED840PIRSENSOR or equivalent in CG/Philips/Bajaj
Supply & fix LED street light fitting Energy saving and environmental friendly long life LED street light fittings 30 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device The light fittings shall be fixed on pole/bldg with and including 25/40 mm dia ( or higher size as per manufacturer recommendation), bracket 1.5 m long complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers painting the clamps with coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed. Make: Havells, Cat Part No: ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC or equivalant in Philips/Bajaj/CG
Supply and fix High light intensity empowered color changing & monochromatic LED under water fountain light with polarized light design & intelligent logarthim control technologh & included external electronic driver etc. complete all as specified and directed.
S&F 36 watt fluoroscent tubelight complete all as specified and directed.
S&F 28 Watt fluoroscent tubelight complete all as specified and directed.
S&F 36 Watt Electronic Ballast suitable for 36 watt fluoroscent tubelight complete all as specified and directed.
S&F 28 W Electronic ballast suitable for 28 W fluorsocent tubelight complete all as specified and directed.
S&F starter suitable for 28/36 watt fluoroscent tubelight fitting complete all as specified and directed.
S&F 18 W LED PLL tube 4 Pin type complete all as specified and directed. Make : Crompton/Havells/HPL
S & F 10 watt LED PLL tube 2 Pin type complete all as specified and directed. Make- Crompton/Havells/HPL
S & F twisted type CFL 10 watt 2 PIN Type complete all as specified and directed.
S& F Modular switch 5 Amps fino Type complete all as specified and directed.
S&F Modular socket 5 Amps fino Type complete all as specified and directed.
S&F Modular switch 15 Amps fino Type complete all as specified and directed.
S&F Modular socket 15 Amps Fino type complete all as specified and directed.
S&F Install bus bar panel box with copper bus bar of 300 amps capacity and 200 Amps MCCB as incomer with breaking cpacity 35 KA 4 Pole . The panel shall be made out 3 mm thick CRCA sheet , wallmounting type front opening hinged type double shuttered including powder coating, for housing BDs with bakelite sheet of 1.2 mm thick fixed inside complete with locking arrangement by using panel locks & necessary fixing arrangements and including inter connections from cable and BD with connecting materials earthing dolly etc complete of size 40x30x25 cm complete all as specified and directed.
S&F VTPN 8 way IP 43 IK-09 with double door suitable for provision of MCCB 160 Amps, 25 KA 4 Pole and for housing of MCBs complete all as specified and directed.
S&F VTPN 4 way IP 43 IK-09 with double door suitable for Provision of MCCB 100 Amps, 25 KA, 4 POLE and for housing of MCB's complete all as specified and directed.
S&F MCB DB SPN 4 way IP-43 IK-09 with metal door suitable for housing MCBs complete all as specified and directed.
S&F MCB DB SPN 08 way IP43 IK-09 with metal door suitable for housing of MCBs complete all as specified and directed.
S&F MCB DB SPN 12 way IP 43 IK-09 with metal door suitable for housing of MCBs complete all as specified and directed.
S&F MCCB 200 Amp 415V, 35KA 4 Pole Ics =100% Icu with thimbles/lugs and nut bolts complete all as specified and directed.
S&F MCCB 160 Amp 415V, 25KA 4 Pole with thimbles/lugs and nut bolts complete all as specified and directed.
S&F MCCB 125 Amps, 415V 25KA 4 Pole with thimbles/lugs and nut, bolts complete all as specified and directed.
S&F MCB SP 240 Volts, 10 KA C Curve MCB Sp 6 to 32 Amps complete all as specified and directed.
S&F MCB SP 240 Volts , 10 KA C Curve MCB Sp 40 to 63 Amps complete all as specified and directed.
S&F MCB DP 6 to 32 Amp 10 KA 240 V C Curve and electric connections with copper thimbles complete all as specified and directed.
S&F MCB DP 40 to 63 Amps 10 KA 240 Volt C Curve and electric connections with copper thimbles complete all as specified and directed.
S&F in replacement of sheet metal enclosure with socket plug top single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 06 to 32 Amps complete all as specified and directed.
M & L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 1991 & testing complete including 15mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GI watering pipe etc. complete all as specified and directed.
Taking down ceiling fan single phase 240 V 1200 mm /1400mm sweep from the existing position including disconnecting supply cable from ceiling rose / connector opening ceiling fan carefully and taking out worn out/defective spare parts such as bearing/ bush shaft , blades, split pin condenser rubber reel nuts and bolts and washer etc cleaning and washing the bearings /bushs thoroughly and applying necessary lubricants etc and reassembling of ceiling fan after replacement of wornout parts and hanging in original position connecting and testingcomplete all as specified and directed. [Note :- 1. Replacement of spares for ceiling fan shall be measured and paid seperately 2. Labour for Minor repairs of fan such as oiling, lubrication , fixing of loose connection, replacement of capacitor , regulator, switch etc must be rectified at the site and included in the rate quoted. 3. All the stationery i.e complaint register, related to the work shall be arranged and maintain by the contractor. the Complaint register shall be maintained as per the guideline directed and specified by JE or Engr-in-Charge.]
Ditto all as per Ser Item No 61.00 above but for exhaust fan 300 / 450 mm sweep , metal/plastic body of any make complete all as specified and directed.
Ditto all as per SerI tem No 61.00 above but for wall mounting fan any sweep complete all as specified and directed.
S&F in replacement of ceiling fan stator of size 1200/1400 mm sweep size match to existing fan rotor of any make as per site requirement complete all as specified and directed.
M&L for replacement of down rod complete of ceiling fan made of 15 mm dia MS pipe medium grade complete with bolts/Check nuts , washers etc upto 45 cm long and all as directed by Engr-in-Charge including drilling, threading all as reqd at site complete all as specified and directed.
Ditto all as per Ser Item No 65.00 above but 1.5 ft long complete all as specified and directed.
Ditto all as per Ser Item No 65.00 here in before but 3 ft long
Supply and fix ball bearing SKF 6201 complete all as specified and directed.
Supply and fix ball bearing SKF 6202 complete all as specified and directed.
Supply and fix ball bearing SKF 6203 complete all as specified and directed.
Supply and fix ball bearing SKF 6204 complete all as specified and directed.
S&F Gunmetal bush complete all as specified and directed.
Supply and fix capacitor 2.5 Mfd /3.15 mfd complete all as specified and directed.
Supply and fix capacitor 4 Mfd complete all as specified and directed.
Supply and fix rubber reel with nuts bolts and split pin for ceiling fan complete all as specified and directed.
Supply and fixing PVC unsheathed 3 core cable copper flexible wire 0.5 Sqmm size complete all as specified and directed.
M&L for rewinding of ceiling fans of 1200 / 1400 mm sweep with exising size of copper winding with same number of turns complete with new mica shets/papter, varnishing, heating and testing after rewinding complete with insulation complete all as specified and directed.
M&L for rewinding of exhaust fans of 300 / 380 / 450 mm sweep with suitable size of copper winding wire of same gauge & number of turns complete with insulation complete all as specified and directed.
M&L for rewinding of wall fans of 400/450 mm sweep with suitable size of copper winding wire of same gauge & number of turns complete with insulation complete all as specified and directed.
M&L for rewinding of Pedestal fans of 400/450 mm sweep with existng size and gauge size of copper winding wih same number of turns complete with new mica sheets/Paper, varnishing, heating and testing after rewinding complete complete all as specified and directed.
S&F fan clamp with rubber seal, nut bolts and safety pin suitable for ceiling fan complete all as specified and directed.
Taking down Geyser from the its existing position (technical & domestic area o by disconnecting all connection, painting to geysers of any make/capacity after scrubbing and cleaning and painting with one coat of white enameled colour including wirting, MES No with black paint 20 mm letter size etc and reinstallation and connecting up complete all as specified and directed.
Supply and fix thermostat suitable for geyser of any make and any size complete all as specified and directed.
Supply and fix indicating neon lamps suitable for geyser of any make complete all as specified and directed.
Supply and fix siphon assembly suitable for geyser of 25/50 ltrs capacity with including nuts bolts and washer suitable for geyser of any type and Make complete all as specified and directed.
Supply and fix PVC connecting pipe heavy duty 15 mm dia for inlet and outlet with brass coupling complete all as specified and directed.
Supply and fix geyser element 250 V 1.5 KW suitable for 25 ltrs capacity complete all as specified and directed.
Ditto all as per Ser Item No 87.00 above but for 35/50 Ltrs capacity of 2 KW complete all as specified and directed.
M&L for taking down of unserviceable geysr of capacity 25/50 ltrs from its existing position (techical & domestic area of AF Station lohegaon) and carry out the rectification such as taking out of copper/SS tank of geyser, brazing/welding of leakage part of the geyser. After rectification leak proof testing to be carried out and refixing the same geyser after complete rectification at the existing position using nut bolts, faster etc complete all as specified and directed.
Adinath Technical Services
Smruti Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .