Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹26.4 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹31.3 L+₹4.8 L (18.3%)Admitted-Finance 1853 2ND FLOOR BHAGIRATH PALACE SURYA BAZAR CHANDI CHOWK NORTH DELHI DELHI 110006 | NORTH | DELHI | 110006 | L2 | Admitted-Finance |
Tender Value
₹38.0 L
EMD Value
₹76,089
Closing Date
2 May 2026, 11:00 amClosed
Executive Engineer (Elect.)
Executive Engineer (E),PWD NES/M-251, LM Bund Road, Ramesh Park, Delhi
Supplying of fittings, MCCBs, Timers and cables etc. and repairing and servicing of High Mast)
2026_PWD_290316_1
10/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
Percentage
60 days
under M-2511
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹76,089
Yes
4 May 2026
24 Apr 2026
2 May 2026
24 Apr 2026
2 May 2026
24 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage rotection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of nitial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 m/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- harge as per requirement. (Thermal management: heat sink of luminium housing such that LED junction temperature shall ot rise above 90°C). | - | - | - | - |
| - | 120 watt | - | Each | - | - |
| - | 150 Watt | - | Each | - | - |
| - | 200 Watt | - | Each | - | - |
| - | LED Flood Light, powder coated pressure die cast aluminium System lumen efficacy ≥120 and <135 lm/Watt).
Supplying of Flood light, powder coated pressure die cast aluminium body with uilt in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, nternal surge protection of 5 KV L,N,E as per IEC 61000-4-5, river efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage rotection, EMI-EMC as per CISPR-15, lenses for beam angle 30 eg-120deg as per the application and the project requirement, uitable tilt able fitting, life time (LED, Driver & electrical ircuitry) of minimum 50000 Burning Hours with 70% of nitial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation olour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant IS standard complete in all respect i/c external connections ith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing equired for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | - | - | - | - |
| - | 200 Watt | - | Each | - | - |
| - | 250 Watt | - | Each | - | - |
| - | Supplying & Fixing of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
3 output(1output per phase) and suitable for three phase supply | - | Each | - | - |
| - | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. | - | - | - | - |
| - | 100 A,30KA, FPMCCB | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.18 MB
BOQ_385354.xls
BOQ • 0.28 MB
corrigendumdateandtime.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .