Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.3 LAccepted-Finance B 176 SECTOR 71 NOIDA GAUTAM BUDH NAGAR | NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | L1 | Accepted-Finance Qualified | |
| 2 | L2₹1.1 Cr+₹10.3 L (10.5%)Accepted-Finance | L2 | Accepted-Finance Qualified | |
| 3 | Not Admitted-Fee/PreQual/Technical SUBHASH NAGAR BALLIA | BALLIA | BALLIA | UTTAR PRADESH | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical PTAEL NAGAR TELIPHONE EXCHANGE BIJROL ROAD BARAUT BAGPAT UTTAR PRADESH 250611 | BAGHPAT | UTTAR PRADESH | 250611 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
10 Nov 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Superintending Engineer, Baghpat
work for B.Plan 2023-24 under EDD-II Baraut
2023_PVVNL_850078_1
79/2023-24/EDC-BPT
Open Tender
Electrical Works
Lump-sum
EDD-II Baraut
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Superintending Engineer
₹78,000
17 Nov 2023
12 Oct 2023
10 Nov 2023
12 Oct 2023
10 Nov 2023
12 Oct 2023
Amount
dsUnzh;d`r lkexzh Hk.Mkj dsUnz ckxir@cMkSr@esjB ls ihlhlh@,lVhih iksy@ifjorZd ,oa vU; ykbZu lkexzh izkIr dj dk;Z LFky rd igqpkus dk dk;ZA ¼yksfMax vuyksfMax lfgr½
400 dsoh, ifjorZd
250 dsoh, ifjorZd
100 dsoh, ifjorZd
63 dsoh, ifjorZd
25 dsoh, ifjorZd
ihlhlh iksy 09 ehVj
ihlhlh iksy 8-5 ehVj
,l0Vh0 iksy 11 ehVj
,l0Vh0 iksy 13 ehVj
,lh,lvkj ohty dUVDVj
,0lh0,l0vkj0 jsfcV dUMDVj
,0lh0,l0vkj0 MkWx dUMDVj
,0ch0 dUMDVj 3x95+1x70+1x16 sqmm
,0ch0 dUMDVj 3x120+1x95+1x16 sqmm
11 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3x120 mm)
11 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3x185 mm)
33 dsoh fiu bUlqysVj QhfVax lfgr
11 dsoh fiu bUlqysVj QhfVax lfgr
11 dsoh fMLd bUlqysVj QhfVax lfgr
11 dsoh vkmVxksabZx ohlhch 200@100@5 ,
11 dsoh budafex ohlhch 600@300@5 ,
ttZj@yEcs LiSu@ubZ ykbZu fuekZ.k gsrq x<<k [kksndj iksy yxkus dk dk;ZA
ihlhlh iksy 09 ehVj
ihlhlh iksy 8-5 ehVj
,l0Vh0 iksy 11 ehVj
,l0Vh0 iksy 13 ehVj
,0lh0,l0vkj0 ohty dUVDVj
,0lh0,l0vkj0 jsfcV dUMDVj
,0lh0,l0vkj0 MkWx dUMDVj
,0ch0 dUMDVj 3x95+1x70+1x16 sqmm fcNkus dk dk;ZA
,0ch0 dUMDVj 3x120+1x95+1x16 sqmm fcNkus dk dk;ZA
33 dsoh fiu bUlqysVj QhfVax lfgr
11 dsoh fiu bUlqysVj QhfVax lfgr
11 dsoh fMLd bUlqysVj QhfVax lfgr yxkus dk dk;ZA
400 dsoh, ifjorZd VªkWyh LFkkfir djds ykbZu pkyw djus dk dk;ZA
250 dsoh, ifjorZd fIyUFk ij LFkkfir djds ykbZu pkyw djus dk dk;ZA
Mcy iksy ij 100 dsoh, ifjorZd LFkkfir djus dk dk;Z
Mcy iksy ij 63 dsoh, ifjorZd LFkkfir djus dk dk;Z
Mcy iksy ij 25 dsoh, ifjorZd LFkkfir djus dk dk;Z
11 dsoh vkmVxksabZx ohlhch 200@100@5 , dUVªksy :e esa LFkkfir djus dk dk;ZA
11 dsoh budafex ohlhch 600@300@5 ,
11 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3x120 mm) dks x<<k [kksnuk o ywi cukdj dsfcy dks dUVªksy :e@Mcy iksy rd fcNkus dk dk;ZA
11 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3x185 mm) dks x<<k [kksnuk o ywi cukdj dsfcy dks dUVªksy :e@Mcy iksy rd fcNkus dk dk;ZA
fufonknkrk }kjk miyC/k djk;h tkus okyh lkexzhA
11 dsoh dsfcy TokbZfVax fdV bUMksj 3x120 sqmm
11 dsoh dsfcy TokbZfVax fdV vkmVMksj 3x120 sqmm
11 dsoh dsfcy TokbZfVax fdV buMksj 3x185 sqmm
11 dsoh dsfcy TokbZfVax fdV vkmVMksj 3x185 sqmm
11 dsoh dsfcy TokbZfVax fdV vkmVMksj 3.5x70 sqmm
TokbZfVax fdV vkmVMksj 3.x400 sqmm
Alu. Cable 3.5x50 sqmm XLPE
1x400 sqmm Cable for Lead
1x240 sqmm Cable for Lead
11 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3.5x70 sq mm)
11 KV Fuse Set
33 KV Fuse Set complete with Structure
,e0,l0 psuy 125x65x1300 T-off
VkWi psuy 125x65x6x2240 mm
VkWi psuy 100x50x5 mm
,e0,l0 ,sUxy 65x65x6x2080 mm
,e0,l0 ,sUxy 75x75x6x2028 mm for T/F Base
,e0,l0 ,sUxy 75x75x6x2028 mm for T/F Base
MªkWij psuy 100x50x6x2040 mm
xkfMax ,Uxy 75x75x6x1600 mm
,e0,l0 ,Uxy 50x50x5 for Garding
,e0,l0 ,Uxy 50x50x1300 for Garding
,e0,l0 ,Uxy 50x50x1600 for Garding
33 dsoh Bracing Set
33 dsoh X-Arm
11 dsoh X-Arm
F-Bracket with Nutbolt
Holding Clamp
Piercing Clamp
End Clamp
Suspension Clamp with J-Hook
I-Hook With Bolt
LT Distrubution Box 3 Phase with Clamp
LT Schakle insulator
LT Holding Clamp for PCC/STP with Nut bolt
33 KV Stay Set Complete
Stay Set Complete
Earthing Complete
Water Level Earthing Complete (Pipe Type)
Chemical Earthing for T/F and VCB
GI Wire 10 SWG for Guarding
GI Wire 8 SWG for Guarding
Alu. Lugs 240 sqmm
Alu. Lugs 400 sqmm
Copper Busbar
LT XLPE Cable 3.5x400 sq mm for doule ckt
Fuse Strip 250 KVA T/F 2mm
Tailess unit 400 amp (complete)
iksyks dh xzkmfVax dk dk;Z vko';d lkexzh lfgrA
400@250 dsoh, ifjorZd gsrq fIyUFk cukus dk dk;ZA
400@250 dsoh, ifjorZd dh fIyUFk ds pkjksa vksj QSfUlax djus dk dk;ZA
eqfoax VªkWyh miyC/k djkukA
fufonknkrk }kjk miyC/k djk;h x;h lkexzh ykbZu ij vko';drkuqlkj yxkus dk dk;ZA
11 dsoh dsfcy TokbZfVax fdV bUMksj 3x120 sqmm
11 dsoh dsfcy TokbZfVax fdV vkmVMksj 3x120 sqmm
11 dsoh dsfcy TokbZfVax fdV buMksj 3x185 sqmm
11 dsoh dsfcy TokbZfVax fdV vkmVMksj 3x185 sqmm
11 dsoh dsfcy TokbZfVax fdV vkmVMksj 3.5x70 sqmm
TokbZfVax fdV vkmVMksj 3.x400 sqmm
Alu. Cable 3.5x50 sqmm XLPE
1x400 sqmm Cable for Lead
1x240 sqmm Cable for Lead
11 dsoh ,Dl0,y0ih0bZ0 dsfcy¼3.5x70 sq mm)
11 KV Fuse Set
33 KV Fuse Set complete with Structure
33 dsoh Bracing Set
,e0,l0 psuy 125x65x1300 T-off
VkWi psuy 125x65x6x2240 mm
VkWi psuy 100x50x5 mm
,e0,l0 ,sUxy 65x65x6x2028 mm
250 dsoh, ifjorZd dh fIyUFk ij ,e0,l0 ,sUxy 75x75x6x2028 mm yxkus dk dk;ZA
400@250 dsoh, ifjorZd dh fIyUFk ij ,e0,l0 ,sUxy 75x75x6x2028 mm yxkus dk dk;ZA
MªkWij psuy 100x50x6x2040 mm
xkfMax ,Uxy 75x75x6x1600 mm
,e0,l0 ,Uxy 50x50x5 for Garding
,e0,l0 ,Uxy 50x50x1300 for Garding
,e0,l0 ,Uxy 50x50x1600 for Garding
33 dsoh X-Arm
11 dsoh X-Arm
F-Bracket with Nutbolt
Holding Clamp
Piercing Clamp
End Clamp
Suspension Clamp with J-Hook
I-Hook With Bolt
LT Distrubution Box 3 Phase with Clamp
LT Schakle insulator
LT Holding Clamp for PCC/STP with Nut bolt
33 KV Stay Set Complete
Stay Set Complete
Earthing Complete
Water Level Earthing Complete (Pipe Type)
Chemical Earthing for T/F and VCB
GI Wire 10 SWG for Guarding
GI Wire 8 SWG for Guarding
Alu. Lugs 240 sqmm
Alu. Lugs 400 sqmm
Copper Busbar
LT XLPE Cable 3.5x400 sq mm for doule ckt
Fuse Strip 250 KVA T/F 2mm
Tailess unit 400 amp (complete)
eqfoax VªkWyh dh QSfUlax dk dk;ZA
dk;Z LFky ls mrkjh x;h ttZj ,oa iqjkuh fo|qr lkexzh dks lqjf{kr fo|qr Hk.Mkj dsUnz esa igqpkus dk dk;ZA¼yksfMax vuyksfMax lfgr½
100 dsoh, ifjoZrd
250 dsoh, ifjoZrd
11 KV 3x120 XLPE cable old & use
GI Wire
ST Pole
ACSR Dog/Weasel Conductor old & use
ACSR Rabbit Conductor old & use
uksV& 1- mijksDr dk;Z dz0la0 01 ls 16 rd dh ek=k iw.kZr% vuqekfur gS rFkk dksbZ Hkh dk;Z 'kwU; ls vf/kdre ¼fufonk /kujkf'k dh lhek ds vUnj½ gks ldrk gSA 2- izR;sd dk;Z dk ekiu odZ'[email protected] dsUnz }kjk fuxZr lkexzh ds xsVikl ds vk/kkj ij fd;k tk;sxkA 3- Lohd`r izkDdyu ds vUrxZr dk;Z djk;k tk;sxkA 4- jsLiksa ekudksa ds vuqlkj dk;Z djk;k tk;sxkA 5- mijksDr dk;Z fctusl Iyku 2023&24¼20 djksM½ esa vfrfjDr ifjorZd ,oa {kerk o`f+) ds ifjorZd yxkus ,oa vU; dk;Z gsrq fd;k tkuk gSA Lohd`r izkDdyu@ekSds LFky dh ck/;rk ds vk/kkj ij vfrfjDr dk;Z Hkh tksMs tk ldrs gS rFkk Lohd`r izkdyu ds vk/kkj ij mijksDr dk;ksaZ esa 20 izfr'kr dh ?kVkSrjh@c<kSrjh dh tk ldrh gSA 6- mijksDr dk;Z esa vkbZVe okbZt izpfyr@ekfdZV jsV izkIr uk gksus dh n'kk esa vkbZVe okbZt fuxksf'k,slu djk;k tk;sxkA
PS ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .