Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹15.7 L+₹2.2 L (16.1%)Rejected-Finance 39 W 1 ASHOK VIHAR SAKET NAGAR KANPUR 208014 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208014 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹16.8 L+₹3.4 L (25.0%)Rejected-Finance 6 18 GANGA GHAT UNNAO UP PIN 209861 | UNNAO | UNNAO | UTTAR PRADESH | 209861 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹17.4 L+₹3.9 L (29.1%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹21.0 L+₹7.6 L (56.2%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Jan 2024, 6:00 pmClosed
MAJ VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
PERIODICAL SERVICES TO OTM ACCN ETC CLEANING OF WATER STORAGE TANK, ROAD MARKING PAINT, CLEANING OF SEWAGE LINE, SEPTIC TANK, MH, REPAIR OF SEWAGE LINE, MH, MAN HOLE COVER ETC IN DGQA AREA UNDER AGE B/R-I OF GE (I) KANPUR
2023_MES_632693_1
GE(I)/KAN/T-83 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹50,000
Yes
18 Mar 2024
14 Dec 2023
18 Jan 2024
14 Dec 2023
11 Jan 2024
28 Dec 2023
Amount
M&L for preparation of old plastered surfaces and applying one coat of white wash as on wall including removing/ brooming down or scraping down loose dirt by steel wire brushes etc complete all as specified.
All as per Item No 01 above but as on ceiling.
M&L for preparation of old plastered surfaces including removing / brooming down or scraping down loose dirt by steel wire brushes etc, applying wall care putty where required for filling purpose of any depression /cavity etc and applying one coat of oil bound distemper of any colour on wall by Trucare Graco machine/Airless paint sprayer (Vands Engineering solutions) / Airless sprayer machine Surya 9 (Jaguar) / Control Pro 190 Air paint sprayer (Wagner) and capable of operational single spray gun with a maximum materials hose length 150m working complete all as specified and directed. (Note : M&L for protecting/covering door/window etc during spray shall be deemed to be included in this item.)
All as per Item No 03 above but on any type of surface of ceiling / false ceiling.
All as per item No 03 above but applying two coats of oil bound distemper.
M&L for complete removal of existing treatment from surface of walls and preparation of old plastered surfaces and applying two coats of oil bound distmper over a coat of primer of any colour by Trucare Graco machine/Airless paint sprayer (Vands Engineering solutions) / Airless sprayer machine Surya 9 (Jaguar) / Control Pro 190 Air paint sprayer (Wagner) and capable of operational single spray gun with a maximum materials hose length 150m working and applying wall care putty for getting smooth surface complete all as specified and directed. (Note : M&L for protecting/covering door/window etc during spray shall be deemed to be included in this item.)
All as per Item No 06 above but on any type of surface of ceiling.
M&L for preparation of old plastered surfaces and applying one coat of cement based paint of approved shade on plastered surfaces or unplastered surface of wall including brooming down or scraping down loose dirt by steel wire brushes etc complete all as specified.
M&L for complete removal of existing treatment from surface of walls and preparation of old plastered surfaces and applying two coat of cement based paint of approved shade on plastered surfaces of wall complete all as specified and directed.
M&L for preparation of old plastered surfaces including removing / brooming down or scraping down loose dirt by steel wire brushes etc, applying wall care putty where required for filling purpose of any depression /cavity etc and applying one coat of exterior weather proof anti algae (Product : Asian Paints Apex or equivalent of makes as specified) 100% acrylic emulsion with maximum working pressure of 3300 PSI by Trucare Graco machine/Airless paint sprayer (Vands Engineering solutions) / Airless sprayer machine Surya 9 (Jaguar) / Control Pro 190 Air paint sprayer (Wagner) and capable of operational single spray gun with a maximum materials hose length 150m working,complete all as specified and directed. (Note : M&L for protecting/covering door/window etc during spray shall be deemed to be included in this item.)
M&L for complete removal of existing treatment from surface of walls and preparation of old plastered surfaces and applying two coats of exterior emulsion paint (weather proof anti algae) (Product : Asian Paints Apex or equivalent of makes as specified) 100% acrylic emulsion paint over a coat of primer with maximum working pressure of 3300 PSI of any colour by Trucare Graco machine/Airless paint sprayer (Vands Engineering solutions) / Airless sprayer machine Surya 9 (Jaguar) / Control Pro 190 Air paint sprayer (Wagner) and capable of operational single spray gun with a maximum materials hose length 150m working and applying wall care putty for getting smooth surface complete all as specified and directed. (Note : M&L for protecting/covering door/window etc during spray shall be deemed to be included in this item.)
M&L for preparation of old wooden surfaces width or girth exc 10 cm and applying one coat of synthetic enamel paint complete all as specified.
All as per Item No 12 above but two coat of synthetic enamel paint.
M&L for preparation of old steel surfaces width or girth exc 10 cm and applying one coat of synthetic enamel paint complete all as specified.
Cutting and taking out grass shurbs, plants, small tree roots in building wherever periodical services to be carried out in OTM/ Md Accn in any position and at any height (two storey building) and treated with necessary chemical/ acid to avoid for this further growth and disturbed portion making good with PCC 1:2:4 type B0 using 12.5mm graded stone aggregate and 15mm thick plastering etc in CM (1:4) finished fair and even complete all as specified and as directed. (Note : The cost of scaffolding and T&P required for repair will be deemed inclusive in this item).
Taking down cement plaster on bricks including raking out joints hacking for key scrubbing down with water etc. complete all as specified.
Dismantling loose concrete cover of RCC coloumns, beams slabs, chajjas and the like as directed, roughening and cleaning in concrete surfacces with steel wire brushes, washed with water and allowed to dry including derusting of steel reinforcement , providing chicken wire mesh fixed with suitable nailis etc as reinforcement to concrete surfaces, applying adhesive/admixture over mesh and providing 20 mm thick (average thickness) dubbing coat in CM (1:3) including 10 thick plastering in CM 1:4 even and smooth complete all as directed including providing scaffolding system on the exterior side, upto two storey building made with wooden balli/bamboo of suitable size or MS tube stiffened with suitable bracing, runners connection with the building, challies for making working platform upto requisite height and required location with essential safety features for the workmen etc. Complete as per direction and approval of Engr-in-Charge.
M&L for 10mm thick cement plaster on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar 1:4 to fair/unfair surfaces of wall finished fair and even complete all as specified and as directed.
M & L 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces, mixed with water proofing compound as per manufacturer's instructions, surfaces finished fair and even complete all as specified and directed by Engineer-In-Charge. Note:- WPC will be measured and paid separately.
M & L for 15mm thick rendering in cement mortar 1:6 on brick or concrete surfaces of wall finished even and smooth without using extra cement complete all as specified.
Supply only integral water proofing compound. ISI Marked.
M&L for preparation of new plastered surfaces and applying three coats of white wash as on ceiling surfaces complete all as specified.
M&L for preparation of new plastered surfaces and applying three coats of white wash as on wall surfaces complete all as specified and directed
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper on surfaces of wall over a coat of primer and wall care putty for getting smooth surface complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coat of cement based paint of approved shade on plastered surfaces of wall complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coat of weather coat exterior paint on wall surfaces over a coat of primer and wall care putty for getting smooth surface complete all as specified and as directed.
M&L for obliterating old writing of any description n.exc 0.1 Sqm with paint to match existing work complete all as directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian (n.exc 30 CM high) letters etc shall be painted with thick paint so that they stand out boldly and solidly whithout showing marks of brush marks complete all as directed.
M&L for stops, commas, short lines, dashes, hyphens, brackets etc complete all as specified and directed.
M & L preparing / cleaning existing black top surface of road and applying thermo plastic paint on marking of min 2 mm thick single coat a centre line and edge line etc. Road marking of 150/100 mm width using hot mark thermoplastic paint (hot application) white or yellow by indigenous modem propelled road marking machine as directed incl all ingredient such as binder, glass beads, titenium dioxide, calcium carbonate, inter fillets etc. thermoplastic requirement for glass beads shall be conforming to BS-6086 of MORTH specification incl spraying of glass beads etc. as per IRC-35 complete all as specified and as directed by Engineer in Charge.
Cleaning and removing all scale and dirt etc from tank of capacity exc 250 and n.exc 500 liters capacity from circulated pipe without damaging of existing float valves including stampring by stencil of date of cleaning by removing old writing complete all as specified and directed.
Cleaning and removing all scale and dirt etc from tank of capacity exc 500 and n.exc 1000 liters capacity from circulated pipe without damaging of existing float valves including stampring by stencil of date of cleaning by removing old writing complete all as specified and directed.
Demolition of brick work of any description and in any position built in cement mortar including quoins arches and pillars complete all as specified and directed.
M&L for brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 for manholes, drains, septic tanks, soak wells etc. complete all as specified and directed.
Demolition of plain cement concrete in ground floor and pavings not exc 15cm thickness below or above ground level complete all as specified and directed.
M&L 75 mm thick PCC (1:3:6) type C1(using 20 mm graded stone aggregate) as in plinth protection and paving laid in alternate bays finished finish even and smooth wihtout using extra cement complete all as specified and as directed.
M & L for Cleaning/removal of blockage of floor traps/nahani traps of 75 mm/ 100mm bore in kitchan/bathroom/toilets etc up to 1st manhole including of PVC/ Stainless trap grating and refixing the same with white cement with pigment to match the surface as before or any other associated /related complaints not mentioned under this item and will be done as directed by Engr -in-Charge. Note: The Traps shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage of Gully traps up to 1st manhole of any size and any depth including removing RCC covers and refixing the same as before or any other associated /related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as directed. Note: The Gully Trap shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage of Orissa pattern WC 'P'/'S' traps and making functional up to 1st manhole or any other associated /related complaints not mentioned under this item and will be done as directed by Engr -in-Charge. Note: The WC shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage of Europian type WC 'P'/'S' traps and making functional up to 1st Manhole or any other associated /related complaints not mentioned under this item and will be done as directed by Engr -in-Charge. Note: The EWC shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage up to 200 mm bore SWG/RCC pipes including manhole of depth not exc 1.00 mtr using Mechanized / Mechnical means incl removing RCC man hole covers and refixing the same as before all complete and as specified by Engr-in-Charge. Note : Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge
M & L for Cleaning /removal of blockage up to 200 mm bore SWG/RCC pipes including manhole of depth exc 1.00 mtr but not exc 2.00 mtr using Mechanized / Mechnical means incl removing RCC man hole covers and refixing the same as before all complete and as specified by Engr-in-Charge. Note : Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge
M & L for Dewatering/desilting of existing manholes of any size, depth n.exc 1.00m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system) and incl removing RCC manhole Covers and refixing the same after cleaning the same position, complete all as directed by Engineer-in-charge.
M & L for Dewatering/desilting of existing manholes of any size, depth exc 1.00m but n.exc 2.00m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system) and incl removing RCC manhole Covers and refixing the same after cleaning the same position, complete all as directed by Engineer-in-charge.
M & L for Dewatering/desilting of existing Septic Tank/Soakage Well incl removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system) or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area, complete all as directed by Engineer-in-charge (mode of measurement shall be sludge in wet condition). Note for Item No - : The Septic tank shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l using 20mm graded stone agg smooth finished, and reforming benching as required for 150 mm bore pipe, complete all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 meter in depth for shitting sewage lines including trimming of sides etc, complete all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and exceeding 1.5m not exceeding 3.00 meter in depth for shitting sewage lines including trimming of sides etc, complete all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth in soils, complete all as specified.
Removal excavated earth exc 500 metre but n.exc 1.0 KM and depositing where directed at level not exceeding 1.5 metre above the starting point in soil, complete all as specified.
Demolition and breaking up drain pipes 100mm /150mm/200mm bore (salt glazed ware, AC or reinforced) set in cement mortar incl bedding, benching/haunching complete all as specified and removed from site as directed by Engr - in - Charge,
M & L Plain cement concrete (1:4:8), type D-2, using 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete (1:4:8), type D -2, using 40mm graded stone aggregate as in bed to drain pipes of 150 mm bore including packing under and hunching against the sides of pipes after they are laid and tested, complete all as specified.
S & F Reinforced concrete pipes, class NP2, 150 mm bore laid and jointed complete with collars, jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified.
Dismantling of cast iron drain pipes & fittings, jointed in cement mortar and taking out of trench required internal dia of pipe 75mm to 100mm.
S&F 100mm bore cast iron soil waste and vent pipe (spun pipe) in any length with or without ears with cement joints fixed to walls / ceiling or laid in floor complete all as specified and as directed.
S&F 75mm bore cast iron soil waste and vent pipe (spun pipe) in any length with or without ears with cement joints fixed to walls / ceiling or laid in floor complete all as specified and as directed.
S&F in repairs CI Nahani trap 100m complete all as specified and as directed.
S&F in repairs CI Tee 100mm bore pipe complete all as specified and as directed.
S&F in repairs CI Tee 75mm bore pipe complete all as specified and as directed.
S&F in repairs CI Cowls for 100mm bore pipe complete all as specified and as directed.
S&F in repairs CI Cowls for 75mm bore pipe complete all as specified and as directed.
Demolition of RCC (reinforced cement concrete) of any description in ground floors and pavings n exc 15 cm thickness (below or above ground level) incl removing demolished material from site complete as directed by Engr - in - Charge.
M& L for providing precast cement concrete in 1:2:4 type B1 using 20 mm graded stone aggreate as in manhole cover slabs complete all as specified
M&L for Mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia., complete all as specified.
M & L Plain cement concrete ( 1:2:4), type B-1, (using 20 mm graded stone aggregate) as in coping, bed plates & other similar works, including necessary form works wearthering, slightly rounded angles and theading, complete all as specified.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded aggregates) as in surface channels and drains etc complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified. (Note : Debris obtained from dismantling will be removing outside of MOD land)
M&L for 25 mm thick plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in floors, finished even and rough to receive floor topping complete all as specified and directed.
M&L for non skid joint free ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the suraface over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
All as per Item No 72 here-in- before but as in skirting over and including 10 mm thick rendering in CM (1:4) all as specified and as directed.
M&L for glazed ceramic tiles coloured, joint free in vertical surface 300X 450X 7mm thick mm thick as on walls over and incl 10mm thick rendering in cement mortar (1:4) and jointing in neet slurry and pointing in coloured cement to match the inside of tiles all complete as specified and directed.
S&F in repair of PVC low level flushing cistern white 10 Ltrs capacity with inlet 15mm bore ball valve, float ball valve and handle incl brackets, PVC connection 300mm with flanges at both ends screwed down to 15mm bore pipe and 32mm bore PVC flush pipe of required length incl taking out of existing flushing cisterns complete all as specified and as directed.
Note : 1. ( for relevent Items ) - If It is not feasible for access of mechanized system for cleaning of line/ MH/ other associated work, same will be executed as per direction of Engr-in-Charge. Decision of inaccessibility of mechanised system shall be decided by Engr -in- Charge and that will be final. Note 2 : All safety precautions as per government policies in vogue shall be adhered in to-to.
N. K. ASSOCIATES
M/S KALI CHARAN PANDEY AND CO.
PRATAPGARH CONSTRUCTION CO.
M/s. PREM PRAKASH & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .