Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L1 | Accepted-AOC AOC | |
| 2 | L2₹26.7 L−₹2.3 Cr (89.6%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹27.0 L−₹2.3 Cr (89.5%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹27.9 L−₹2.3 Cr (89.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹28.1 L−₹2.3 Cr (89.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
15 Nov 2021, 6:00 pmClosed
GE
GE 860 EWS
PROVN OF STORE SHED FOR OFFRS MESS OF CERTAIN UNIT, GEN SHED FOR 400 KVA GEN SET AT KIARI AND SPECIAL REPAIR TO BLDG NO T-246 AND T-269 OF CERTAIN UNIT AT TANGTSE UNDER GE 860 EWS
2021_MES_483671_1
8167/2021-22/E8
Open Tender
Civil Works
Item Rate
270 days
KIARI
Class E
Category E i
9 documents required · 9 mandatory
₹500
Yes
GE 860 EWS
₹48,000
Yes
24 Feb 2022
25 Oct 2021
22 Nov 2021
25 Oct 2021
15 Nov 2021
8 Nov 2021
Amount
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed.
Excavation in post holes (or similar holes) each not exceeding 0.5cum in hard/dense soil getting out, returning filling and ramming earth or broken rubbles mislead with earth around in layers not exceeding 25 cm watering and removing surplus soil to distance not exceeding 50 mtr and making good surface complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for foundation etc and getting out in hard rock complete all as specified and directed.
Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in soft/disintegrated rock complete all as specified and directed.
Removing excavated material (rock) not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for foundation etc and getting out in hard/dense soil complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base 75mm thick complete all as specified and as directed.
M & L Precast cement concrete block masonry type C-1 1:3:6 (20mm graded crushed stone aggregate) with solid blocks, exc. 10cm in width and, setting in cement mortar 1:6 complete all as Specified.
Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil complete all as specified and directed.
Removing excavated material (soils) not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point complete all as specified and directed.
M&L form work to sides of concrete foundations, footings, bases of columns raft and beams sides and soffits(if any) of foundations and plinth,beams and similar work,vertical or to batter,for rough finished flat surfaces of concrete complete all as specified and as directed.
M&L form work to sides of pillars, posts, struts, piers, columns and stanchions, for square, rectangular or poygonal, rough finished surfaces of concrete complete all as specified and as directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete complete all as specified and as directed.
M &L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L mild steel TMT bars 5mm dia and over upto and including 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) not less than 0.9mm dia or securing with clip as in stirrups, spacers and binders complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M & L for sand filling under floors or in foundation incl watering and consolidation complete all as specified and as directed.
M&L for broken stone or boulder hard core of gauge not exc 63 mm deposited spread and levelled in layers not exc.15 cm thick watered and rammed to a true surfaces complete all as specified
M&L for cement concrete type D-1, 1:4:8 (20 mm graded crushed stone aggregate) 75 mm thick as sub base complete all as specified and directed.
M& L for cement concrete 25mm thick type B - 1 using 20mm graded stone aggregate over sub base to receive floor finish etc complete all as specified.
M& L for cement concrete40mm thick type B - 1 using 20mm graded stone aggregate as in floor incl finishing the surfaces even and smooth without using extra cement complete all as specified.
M & L for Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified.
Screed bed or bedding layer mortar in cement mortar 1:6, 15mm thick for laying floor finishes complete all as apecified and directed by Engr-in-Charge.
M&L for non-skid Ceramic tiles (colour ) 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but n. exc. 0.18sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as apecified and directed by Engr-in-Charge.
M&L rendering in cement mortar 1:4, 15mm thick on fair face on concrete surface and finishing the surface even and fair (without using extra cement) complete all as spd & directed.
S & F 3.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, all as specified.
S&F 0.56 mm , corrugated Aluminium sheeting Alloy 31000 H4 in sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. fixed with L-type or J-type or cranked hook bolts in lieu of screw as spd and directed.
S&F 2 class clean swan timber hardwood in scantling fixed complete all as specified and directed.
M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as spd.
M&L for preparation of new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as spd.
Preparing of new palstered surface of wall of any description and applying two coats of distemper oil emulsion, all as specified.
M&L rendering 15mm thick in cement mortar(1:6) on fair faces of brick or concrete surface finish even and smooth without using cement complete alll as specified
M&L for Plain cement concrete 1:3:6 type C- 1 (using 20 mm graded crushed stone aggregate) as in as in haunching benching and PCC coping including necessary form work complete all as specifed and as directed.
M&L for preparation of new plastered surfaces and apply two coats of cement base paint complete all as specified and directed.
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws with grade of zinc coating 275 , complete as specified complete all as directed by Engr-in-Charge.
S&F FI 40 x 6 mm thick as in fixing of Roof sheet as wind tie all as specified and directed.
Taking down cement plaster on brick stone wall, etc incl racking out of joints hecking for keys scrubbing down with water etc complete alll as specified
M&L for preparation of new plastered surfaces and apply two coats of cement base paint over one coat of alkali resistant primer complete all as specified and directed.
Taking down chowkats or frame n.exc 1.5 Sqm with shutters without taking of shutter from the frame complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frame exc 1.5 Sqm and n exc 4 sqm with shutters without taking of shutter from the frame complete all as specified and directed by Engineer-in-Charge.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue, pinned at joints complete all as specified and directed.
S & F 35mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
S&F for 30mm thick 2nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) complete all as specified
S&F 3 mm thick glass sheet ordinary quality and glazing with oil putty fixed with wodden beads n.exc 0.5 Sqm in each pane complete all as specified and directed.
S&F Extruded Aluminium alloy handle cast type, anodised of size 150mm complete all as specified and directed.
S&F Extruded Aluminium alloy handle cast type, anodised of size 100mm complete all as specified and directed.
S&F 100 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 75 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 100 mm long butt hinges medium weight , cold rolled mild steel and fixed complete all as specified and directed.
S&F 75 mm long butt hinges medium weight , cold rolled mild steel and fixed complete all as specified and directed.
S&F Mild steel sliding door bolt, stove enamelled black not less than 12mm dia with and incl Min 6 Nos of bolt & nuts , four on bolt plate and two on staple plate of size 300 mm complete all as specified and directed by Engr-in-charge.
Demolition of Cement Concrete (Unreinforced) in ground floors and pavings n exc. 15cm thickness (below or above ground level), as specified and directed by Engr-in-Charge.
M&L for 75mm thick cement concrete 1:3:6 type C -1 (using 20mm graded crushed stone aggregate) laid in alternate bays (not exc. 2 sqm each) as in plinth protection and finishing the surface even and smooth with using extra cement and providing joints throughout the thickness of plinth protection, complete all as specified.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets
S & F false ceiling of 4mm thick 3 nos of ply veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with nails to timber frame work complete all as specified and directed.
S & F 9 mm thick prelaminated particleboard, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in wall portion complete all as specified and directed.
Dismantling of timber fillet under 40 Sq cm in section in framed work complete all as specified and directed by Engineer-in-Charge.
M&L Second class soft wood timber scantling plain fillets, square, rectangular or triangular in section clear swan, sectional area exc 13 sqcm & not exc 25 sqcm, secured with nails or brads complete all as specified and directed
M&L for decorative type soft wood beading 30 mm wide fixed on plywood complete all as directed by Engr-in-charge.
Demolition of Cement Concrete (reinforced) in ground floors and pavings n exc. 15cm thickness (below or above ground level), as specified and directed by Engr-in-Charge.
RCC 1:2:4 Nominal mix type B 0 using 12.5 mm graded crushed stone aggregate as in cooking platform complete all as directed by Engr-in-charge.
Demolition of brick work or stone bouldermasonary built in cm includind all quipons arches, piller etc but excluding ashlar gacing dressed work and precast articales complete alll as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed.
M&L for machine cut kota stone slab flooring 20 to 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including griding, rubbing and polishing complete all as specified.
Dismantling boarding, any description, fixed in any position with nails complete all as specified.
S&F for SDC Laminated flooring 8mm thick of any coloured manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength and directed by the Engr-in-Charge.
Dismantling plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering or wall etc.
M &L 0.5mm thick CGI sheets fixed to wall cladding/roofs with two corrogations side lap, fixed with L- type or J type or cranked hook bolts and washers with grade of zinc coating 275, all as specified and directed by engr-in-charge.
S&F 0.56 mm ,plain Aluminium sheeting Alloy 31000 H4 in ridges, hips, valley gutters drip and straight flashing , fixed with coach screws and washers, in roofs, walls etc. fixed with L-type or J-type or cranked hook bolts in lieu of screw as spd and directed.
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc. 15cm thickness (below or above ground level), as specified and directed by Engr-in-Charge.
M & L for PCC 1:3:6 type C 2 using 40 mm graded crushed stone aggregate as in sub base 100mm thick complete all as specified and as directed.
M&L for rubber moulded coloured chequered cement concrete tiles 30cm x 30cm x 20 to 25mm thick, set jointed and pointed in neat cement slurry with grey cement and pigment in floors and jointed with grey cement slurry mixed with pigment match over 15mm thick screed bed or bedding of cement mortar (1:4) complete all specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings, tube light fittings etc complete and removing all retrieved materials to MES stores for segregation of serviceable /Unserviceable fitting&fixture and also making good disturbed surfaces of wall, floors etc complete all asspecified and as directed by the Engineer-in-Charge.
M&L for point wiring complete for one light point / exhaust fan point / bell point controlled by one 1-way switch/ bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC Caing Caping ISI marked of size 20 mm dia medium grade and PVC casing caping fittings such as tees, bends, elbow with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly including metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. Note : The cost of modular type Metal flush boxes are included in point wiring
All as per item No 77 above, but for one 3 pin socket outlet 5 Amp on same board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 77 above, but for one 3 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No. 77 here-in-before, but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor (Multi-stranded) insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common dolly complete all as specified and as directed by Engineer-in-Charge.
S&F Modular Switch 1 way 6 Amps, 1 Module size complete all as directed.
S&F Modular Switch 1 way 16 Amps, 1 Module size complete all as directed.
S&F Modular Socket 6 A, 5, Pin 2 Module size complete all as directed.
S&F Modular Socket 6A/16 A, 5 Pin ,2 Module size complete all as directed.
S&F Modular white cover plate with frame, 1 Module size complete all as directed.
S&F Modular white cover plate with frame, 3 Module size complete all as directed.
S&F Modular white cover plate with frame, 4 Module size complete all as directed.
S&F Modular white cover plate with frame, 6 Module size complete all as directed.
Supply and fixing angular lamp holder including 15W LED Bulb, metal cased body of brass with back plate suitable for 18 watt CFL/60 watt bulb for batten fittings, including Plastic square box of required size complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20/22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Supply and fixing SPN 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and neutral in the MCB DB complete with connection testing and commissioning.
Supply and fixing SP 5 to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and neutral in the MCB DB complete with connection testing and commissioning.
Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-standard) PVC insulated and unsheathed electric cable 1100 volts in and including PVC casing and capping of 25 mm and above (as per conductor run )with all fittings/ accessories and including PVC insulated and unsheathed electric cable 1100 volts1.5 Sqmm ( multi-stranded) copper conductor single core( Green co lour) cable as continuous earth wire connected to common earth dolly including PVC box of required size and shape etc covered with 3 mm thick plastic laminated sheet ( Make Hylum) for one light point independent controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge
All as per item No 97 above, but for one 3 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 97 above, but for one 3 pin socket outlet 5 Amp on same board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No. 97 here-in-before, but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor (Multi-stranded) insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common dolly complete all as specified and as directed by Engineer-in-Charge.
S&F Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed.
Supply and fixing socket 2 in 1, 5 Amp, flush type complete all as specified and as directed by Engr-in-charge.
Supply and fixing switch socket combination multi purpose 2 in 1, 3 pin 5A/16A, 5 in 1 flush type complete all as specified and as directed by Engr-in-charge.
S&F LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing sheet Metal enclosure double shutter type for DB’s 240 Volts Single Pole and Neutral 4 way with 200 Amps rated bus bar complete including wooden board of required size duly painted with matching colour paint acomplete all as specified and as directed by the Engr-in-Charge.
Supply and fixing MCB Double pole and neutral 32Amps , 240 volt, 10 KA, complete all as specified and as directed by the Engineer-in-Charge..
Supply and fixing angular lamp holder, PVC/Polycaronate type with back plate suitable for 10 watt LED bulb for batten fittings complete all as specified and directed by the Engineer-in-Charge.
S&F LED lamp 10W complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing MCB SPN 32 Amps , 240 volt, 10 KA, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing new energy saving Bulk head fitting 12 watt made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK07 as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Eng-In-Charge.
M&L for sub main wiring with 2 run of 2.5 Sqmm FR, PVC insulated, unsheathed and stranded copper conductor cable with and incl one run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : 1. The cost of concealed conduit & accessories is deemed to be included in quoted rates. 2. The two run of 2.5 Sqmm wire and one run of 2.5 Sqmm wire will be measured as one unit.
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor 1100 V grade nominal cross sectional area 10 Sqmm, 2 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-Charge.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.
Material and labour for sand cushioning to under ground electric cable all as per clause No 19.75 of MES SSR Part-I (1991)
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to CBDB’s as specified or indicated including testing on completion .
osho traders
Rampal Singh Contractor
M/S LIBE & CO
M/S GLOBAL ENGINEERS
M/S GEE AAR and SONS ENTERPRISES
BETONG BUILDERS
M/S Behl Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .