Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹3.4 L+₹30,170 (9.84%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹3.4 L+₹38,095 (12.4%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | Rejected-Technical NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | - | Rejected-Technical NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
13 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (AF) Chimney Hills, Bangalore
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
REPAIRS AND MAINTENANCE OF INTERNAL COOLING APPLIANCES OF CERTAIN OTM ACCN BLDGS AT 2 AFSB MYSORE
2020_MES_382494_1
8407/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) (AF) Chimney Hills, Bangalore
As per tender documents
8 documents required · 8 mandatory
₹300
AGE (I) (AF) Chimney Hills, Bangalore
₹6,000
Yes
26 Mar 2021
19 Oct 2020
16 Nov 2020
19 Oct 2020
13 Nov 2020
27 Oct 2020
19 Oct 2020 - 24 Oct 2020
60 days
Amount
Servicing of window/split Air Conditioner of capacity 1.5/2 TR, any make by opening the indoor/outdoor unit, cleaning the air filter, condenser including body of the unit complete with brush and air blower, washing with cleaning detergent & fresh water, greasing fan motor, including rectification/fixing of loose electric connections and replacement of unserviceable electrical knobs/parts complete all as specified and as directed Note : (i) The quoted rates deemed to include all the labour required for replacement of spares (ii) Spare parts shall be measured and paid separately as supplied only under relevant items here in after
Supply only Starting capacitor 80-100 mfd
Supply only running capacitor 36 mfd
Supply only Starting relay
Supply only Over load protector
Supply only Thermostat
Supply only Air Filter
Supply only Wiring kit complete set
Supply only Copper tube 1/2 " with adapter/flair nuts
Supply only Copper tube 3/4 " with adapter/flair nuts
Supply only PC unit/electronic circuit plate of appropriate make/model suitable for 1.5/2 TR capacity Air Conditioners
Supply only Remote control with batteries of appropriate make/model for Split type Air Conditioners
Material and Labour for tracing any gas leakage and arresting the same by brazing work and gas charging with approved eco friendly refrigerant complying CPCB norms to Air Conditioner/Water Cooler/Deep freezer /Refrigerator and testing complete and all as specified and directed
Material and Labour for removing the existing defective / short circuited hermetically sealed compressor unit from the Air Conditioners and replacing the same with company rewound sealed compressor unit of appropiate make / model for 1.5 TR capacity Air Conditioners and testing complete all as specified and directed
All as per item No. 14, here in before but for 2.0 TR capacity Air Conditioners all as specified and as directed
Material and Labour for removing existing defective / short circuited Fan Motor from outdoor unit / indoor unit of 1.5 / 2.0 Ton Air Conditioners and rewinding with super enamelled copper wire of appropriate gauge and quantity with insulating materials and replacement of defective bearings / bushes / fan blade etc., re-fixing and testing complete all as specified and directed
Material and Labour for 3 core, 4 sqmm, PVC insulated, sheathed, shield control copper cable between indoor and outdoor unit of Air Conditioners including taking out old burnt cable complete all as specified and directed
Material and Labour for outdoor unit mounting stand/bracket matching with existing type for split type Air Conditioners with nuts, bolts & wahers etc., including taking out old rusted outdoor mounting stand complete all as specified and directed
Material and Labour for Nitrile insulation foam tape 3 mm thick ( or suitable Nitrile Rubber foam insulation tube / Foam Heat insulated tube of 9mm wall thickness as required at site) wrapped/encased around on copper refrigerant tubes for insulation purpose from indoor unit to outdoor unit including removing old outlived insulation sheets complete all as specified and as directed.
Servicing of water coolers of storage capacity 80/120 ltr and cooling capacity 40/60 ltr per hour, any make/model by opening the body, cleaning of water tank, cooling coil, condensers and body with brush and air blower, washing with cleaning detergent & fresh water, greasing fan motor, including rectification/fixing of loose electric connections and replacement of unserviceable drain pipe etc., complete all as specified and as directed Note : (i) The quoted rates deemed to include all the labour required for replacement of spares (ii) Spare parts shall be measured and paid separately as supplied only under relevant items here in after
Supply only Starting capacitor 60-80 mfd
Supply only running capacitor 25 mfd
Supply only Starting relay
Material and Labour for removing the existing defective / short circuited hermetically sealed compressor unit from water coolers and replacing the same with company rewound sealed compressor unit of appropiate make / model for water coolers 40/80 ltrs capacity and testing complete all as specified and directed
Servicing, maintenance and repairs to Refrigerator/Deep Freezer of capacity up to 286/310 Ltrs, any make/model periodical cleaning of condenser coil and compresser and body with brush and air blower complete all as specified and as directed Note : (i) The quoted rates deemed to include all the labour required for replacement of spares (ii) Spare parts shall be measured and paid separately as supplied only under relevant items here in after
Supply only Starting relay
Supply only plastic ice cube tray, set of two
Supply only hard plastic stand suitable for Refrigerator of any make / model up to 310 ltr capacity.
Material and Labour for removing the existing defective / short circuited hermetically sealed compressor unit from refrigerators and replacing the same with company rewound sealed compressor unit of appropiate make / model for Refrigerator capacity 286/310 ltrs capacity and testing complete all as specified and directed
Servicing, maintenance and repairs to voltage stabilizer, 5/4 KVA capacity of any make and model, replacement of unserviceable PCB with new PCB of suitable type/range complete all as specified and as directed
Servicing, maintenance and repairs to voltage stabilizer, 3/2 KVA capacity of any make and model, replacement of unserviceable PCB with new PCB of suitable type/range complete all as specified and as directed
eurekaenterprises
JM Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .