Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹13,216Qualified Make: HIOKI
Model: HIOKI-DT4212 4 5 2 TULSI CHAMBERS 4TH FLOOR OLD PALASIA INDORE MADHYA PRADESH 452018 | INDORE | MADHYA PRADESH | 452018 | Make: HIOKI
Model: HIOKI-DT4212 | L2 | Qualified | |
| 2 | L3₹23,840Qualified Make: Keysight Technologies
Model: Keysight U1241B E 366 2ND FLOOR NIRMAN VIHAR VIKAS MARG VIKAS MARG VIKAS MARG NEW DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Keysight Technologies
Model: Keysight U1241B | L3 | Qualified | |
| 3 | L4₹33,800Qualified Make: ANALYTICAL
Model: APHY3056 ANALYTICAL HOUSE E67 E68 RAVI PARK VASNA ROAD BARODA GUJARAT 390 015 | BARODA | VADODARA | GUJARAT | 390015 | Make: ANALYTICAL
Model: APHY3056 | L4 | Qualified | |
| 4 | L5₹13,200Qualified Make: FLUKE
Model: Fluke Model 179 F 31 MIDC SATPUR NASHIK CITY MAHARASHTRA SATPUR MIDC NASHIK NASHIK MAHARASHTRA 422007 | NASHIK | MAHARASHTRA | 422007 | Make: FLUKE
Model: Fluke Model 179 | L5 | Qualified | |
| 5 | L6₹34,580Qualified Make: FLUKE
Model: FLUKE-179 506 701 SIDDARTH BUILDING 96 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | Make: FLUKE
Model: FLUKE-179 | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
21 Aug 2018, 9:00 amClosed
digital multimeter Digital Multimeter ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 3.5 3.5
4.5
6.5 Measurement Type True RMS Average
True RMS Counts 6000 4000
6000
50000
200000 (or higher) MEASUREMENTS DC Voltage Range 1000 600
1000 DC Voltage Accuracy 1 0.005
0.05
0.1
0.5
1 DC Voltage resolution 0.1 0.001
0.01
1
10
100 AC Voltage Range 1000 600
1000 AC Voltage Accuracy 1 0.08
1 AC Voltage resolution 0.1 0.001
100 DC Current Range 10 3
10 DC Current Accuracy 1 0.005
1.5 DC Current resolution 0.01 0.001
100 AC Current Range 10 3
10 AC Current Accuracy 1.5 0.5
1.5 1/5 AC Current resolution 0.01 0.001
100 Resistance Range 50 40
50
60
100
500 Resistance Accuracy 1 0.08
1.5
2
2.5
3
3.5 Resistance resolution 0.1 0.001
100 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 1.5 1.5
3.5
5
NA Capacitance resolution ( nF ) 1 0.001
NA Frequency Range ( KHz ) 100 50
200
300
NA Frequency Accuracy ( % ) 0.1 0.1
NA Frequency resolution ( Hz ) 0.01 0.001
NA Temperature Range ( Degree C ) -40 to 400 -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) 1.5 1.5
NA Temperature resolution ( Degree C ) 1 0.001
NA OTHER FEATURES Continuity test and Diode test Available - Data logging Not Available - If Data Logging Feature is Available
Internal Memory NA - Computer Interface along with software Not Available - Dimensions ( mm X mm X mm ) 43 x 90 x 185 - Weight 420 - Other Features Min-max-average recording
Measures twice as fast as other multimeters - SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
Category III 600 V of IEC 61010.
Category 2/5 III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification UL
CE
CSA
TUV
VDE - POWER REQUIREMENTS Power Requirements Battery Operated - if Battery Operated
then Type of Battery Non- Rechargeable (Alkaline) - if rechargeable
then chemistry of the battery NA - if Non-rechargeable
then size of the battery cell 9-V rectangular battery - number of non- rechargeable the battery/cell 1 - Voltage of rechargeable Battery 9 - capacity of rechargeable battery(milli Ampere Hour) 500 - Suitable charger adaptor provided NA - ACCESSORIES Standard Accessories Supplied with the Equipment 80BK Temperature Probe (179 only) Installed 9V battery Test leads Users manual - WARRANTY Warranty 1 1
5 OPERATING CONDITION Minimum Operating Temperature -10 - Maximum Operating Condition 50 - Operating Humidity (RH) 90 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true - conformity to Cold Test for 4 hrs at a specified true - 3/5 minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test 13566/31.03.2017 - Name and address of the Lab for the specification test STAR LAB - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sohan Singh Chaudhary 145001
C/O AOC
Base Logistics Section
Air Force Station Pathankot
2 30
485699
GEM/2018/B/68648
digital multimeter
30 days
Punjab; Pathankot
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter Digital Multimeter ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 3.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type True RMS Average | - | - | - |
| True RMS Counts 6000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 200000 (or higher) MEASUREMENTS DC Voltage Range 1000 600 | - | - | - |
| 1000 DC Voltage Accuracy 1 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 0.1 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 100 AC Voltage Range 1000 600 | - | - | - |
| 1000 AC Voltage Accuracy 1 0.08 | - | - | - |
| 1 AC Voltage resolution 0.1 0.001 | - | - | - |
| 100 DC Current Range 10 3 | - | - | - |
| 10 DC Current Accuracy 1 0.005 | - | - | - |
| 1.5 DC Current resolution 0.01 0.001 | - | - | - |
| 100 AC Current Range 10 3 | - | - | - |
| 10 AC Current Accuracy 1.5 0.5 | - | - | - |
| 1.5 1/5 AC Current resolution 0.01 0.001 | - | - | - |
| 100 Resistance Range 50 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 0.1 0.001 | - | - | - |
| 100 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 1.5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 1 0.001 | - | - | - |
| NA Frequency Range ( KHz ) 100 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 0.1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 0.01 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) -40 to 400 -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) 1.5 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) 1 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available - Data logging Not Available - If Data Logging Feature is Available | - | - | - |
| Internal Memory NA - Computer Interface along with software Not Available - Dimensions ( mm X mm X mm ) 43 x 90 x 185 - Weight 420 - Other Features Min-max-average recording | - | - | - |
| Measures twice as fast as other multimeters - SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| Category III 600 V of IEC 61010. | - | - | - |
| Category 2/5 III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification UL | - | - | - |
| CE | - | - | - |
| CSA | - | - | - |
| TUV | - | - | - |
| VDE - POWER REQUIREMENTS Power Requirements Battery Operated - if Battery Operated | - | - | - |
| then Type of Battery Non- Rechargeable (Alkaline) - if rechargeable | - | - | - |
| then chemistry of the battery NA - if Non-rechargeable | - | - | - |
| then size of the battery cell 9-V rectangular battery - number of non- rechargeable the battery/cell 1 - Voltage of rechargeable Battery 9 - capacity of rechargeable battery(milli Ampere Hour) 500 - Suitable charger adaptor provided NA - ACCESSORIES Standard Accessories Supplied with the Equipment 80BK Temperature Probe (179 only) Installed 9V battery Test leads Users manual - WARRANTY Warranty 1 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature -10 - Maximum Operating Condition 50 - Operating Humidity (RH) 90 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true - conformity to Cold Test for 4 hrs at a specified true - 3/5 minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test 13566/31.03.2017 - Name and address of the Lab for the specification test STAR LAB - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sohan Singh Chaudhary 145001 | - | - | - |
| C/O AOC | - | - | - |
| Base Logistics Section | - | - | - |
| Air Force Station Pathankot | - | - | - |
| 2 30 | - | - | - |
Exempted
21 Aug 2018
16 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_485699.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .