Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹32.7 L+₹2.0 L (6.49%)Rejected-Finance | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹38.2 L+₹7.5 L (24.5%)Rejected-Finance | L3 | Rejected-Finance Not Lowest. | |
| 4 | L4₹40.6 L+₹9.9 L (32.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest. | |
| 5 | L5₹40.8 L+₹10.2 L (33.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest. |
Tender Value
₹29.9 L
EMD Value
₹59,700
Closing Date
22 Dec 2021, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Kamptee Cantt - 441 001
REPAIR / REPLACEMENT OF JOINERY, FLOORING AND CERTAIN MISC B/R AND E/M WORKS AT ARO COMPLEX AT FORT AREA NAGPUR UNDER GE KAMPTEE
2021_MES_491980_1
8351/E8
Open Tender
Civil Works
Item Rate
120 days
Nagpur
Class D, Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹59,700
Yes
21 Jan 2022
2 Dec 2021
24 Dec 2021
2 Dec 2021
22 Dec 2021
17 Dec 2021
Amount
Dismantling of AC (Corrugated or semi corrugated etc) sheets in roof covering including ridges complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
Taking down cement plaster of any description including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and directed.
Dismantling of unserviceable floor, hearth or wall tiling incld cement mortar bedding (but not backing) and removal of rubbish/ debris from premises of MOD Land complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in mortar complete all as specified and directed.
Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for removal of rubbish/debris MD land complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
Dismantling wall and ceiling boards ( Fiber, pulp, insulation etc) or insulation boards, slabs, blankets or of any description in any thickness including cover fillets complete all as specified and directed.
Removing existing water proofing treatment on roof including screed bed and scrubbing down with water etc and removing the same beyond premises of MD land complete all as specified and directed.
M&L for Roof trusses (framed), trussed, purlins, crane ganbies, rails and fastenings and heavy bracket framing (lleam, tee, angle, charmel or flat sections) including distance pieces, cleats etc. conforming to IS 1161-1979 grade Fe 410W (Gde E-250) quality A complete all as specified and directed.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed alusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
M & L for Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for 4mm thick for Non Asbestos, fibre reinforced designer cement ceiling board including Gl frame work for seamless ceiling of size 600mm x 600 mm comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed.
M&L for machine cut cudappa stone slab 20-25mm thick over cement 20mm screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Marble work 18 to 20mm thick over cement 20mm screed (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrana including rubbing and polishing complete all as specified and directed.
M&L for pre-polished Granite (of any type) work (table rubbed and polished) in steps, jams, pillars; cooking platforms and likes in cement mortar (1:4) including pointing in white cement (1:2) using marble dust admixture of pigment to match with shade of granite including necessary notching, chamfering the edges over 20mm screed bed complete all as specified and directed.
M & L for Rounding to edges of stone slabs one edge , such as in steps ,cooking platforms, and other similar situations complete all as specified and directed.
M & L for 50mm Sand filling under floorings/pavement spread and levelled in layers n.exc 15cm thick complete including watering and consolidation complete all as specified and as directed.
M & L for Machine pressed precast conctete interlocking paver block colour glossy finished rubber pressed any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and as directed.
M & L for chequered cement concrete tiles colour glessy finished rubber pressed 30cm x 30cm x 25mm thick set jointed and pointed in neat cement slurry and pointed in coloured pigment over 20mm cement screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for vitrified ceramic tiles 10 mm thick (square or rectangular) polished, light shed area of each tile not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in site or colored cement to match over 15mm cement screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for vitrified ceramic tiles 10 mm thick (square or rectangular) polished, light shed area of each tile not exceeding 0.36 sqm in skirting etc set and jointed in neat cement slurry and pointed in site or colored cement to match over 15mm cement screed bed in cement mortar 1:6 complete all as specified and directed.
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding. 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15 mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed.
M&L for colored glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm/ 300x 450x 7mm thick set and jointed in neat cement slurry and pointed in site or color cement to match including rendering 10mm thick in cement mortar 1:4 complete all as specified and directed.
M&L for 10mm thick rendering on fair faces of brick work or concrete surface in cement plaster (1:6) finished the surface fair complete all as specified and directed.
M & L for preparation of new surface of wall and applying two coats of oil bound distemper over a coat of 3mm thick wall care putty complete all as specified and directed.
M&L for brick work with fly ash brick old size straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished fair and even all complete all as specified and directed.
M&L for preparation new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L for 25mm (avg) thick cement concrete type B-0, 1:2:4 (12.5mm grade aggregate) finishing cement concrete surface even and smooth without using extra cement using water proofing liquid @ 200 ml/50 kg of cement (Note- Water proofing liquid will be measured & paid separately complete). complete all as specified and directed.
Supply only liquid water proofing admixture of make-pidilite or equivalent complete all as specified and directed.
M&L for provision of water proofing treatment by using APP torch on mineral/slate finished membrance over roof and vertical surfaces including preparation of surfaces and applying oil based bituminous primer coat @ 0.30 ltr per sq m on clean and dry surface and then providing APP membrane having non woven. polyster film reinforcement with 3 mm thick and weight not less than 3 .00 kg/sq m and finished on top with mineral/slate finished torch on system laid with 100 mm & 150 mm over lap on side & end laps resepectely all as per manufacturers instructions over and including rendering 15mm thick in cement mortar 1:3 on concrete surfaces complete all as specified and directed.
M & L for plain cement concrete in sub bases/pavings Type D2 1:4:8 (40mm graded aggregate) complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm broken stone or boulders deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for cement concrete tybe B-1, 1:2:4 (20mm graded aggregate) in floor finish/pavings concrete surface even and smooth without using extra cement complete all as specified and as directed.
M&L for POP board false ceiling multi level 12/12.5mm thick fixed in galvanized grid work as required quanity as site with 25mm long self drilling and tapping screw acing phillips head with under end outer at 200mm centre to centre, including finishing to joint of face board with specially formulated jointing compound including GI suspenders of 6mm thick and joints of ceiling board shall be finsihed 48 mm wide fibre tape to provide eseam less finish etc, M&L for preparing POP false ceiling and applying two coat of luster paint over coat of primer as per recommended by manufacture etc, complete all as specified and directed.
M&L for POP corners mouldings 150mm grith with screw on walls etc, complete all as specified and directed.
M&L for 10 to 12mm thick toughend tinted glass fixed to door or as partition or any other location including brackets, supports, handles, lock , bottom machine and other accessories as required complete all as specified and directed.
S&F in repairs Wash Hand basin ( flat back or angle back )of size 550 X 400 MM white including , waste pipe, chain and plug, porcelain stopper including for & pinning in ends of brackets including supply & fixing of waste pipe complete all as specified and directed.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with pIngs including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x330mm x160mm complete all as specified and directed.
S&F 32mm Waste fittings, brass,chromium plated for glazedw are sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F 40mm Waste fittings, brass,chromium plated for glazedw are sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F GI water tubing medium grade 15mm bore galvanized with all fittings & fixture complete to walls and ceilings or laid in floors including taking up or down steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F GI water tubing medium grade 20mm bore galvanized with all fittings & fixture complete to walls and ceilings or laid in floors including Taking up or down steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S & F in repairs 15 mm bore chromium plated Bib cock with flange, complete all as specified and directed. Make- Prayag, CAT No.: 8306 or equivalent
S & F in repairs 15 mm bore chromium plated Bib cock Long body with flange, complete all as specified and directed. Make- Prayag , CAT No.: 8308 or equivalent
S&F in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top)of 1000 litres capacity hoisted and fixed in position and including dismantling water tank and removing from site complete all as specified and directed.
M&L for complete removal of existing treatment of and applying two coat of acrylic low VOC emulsion with silicon additives an anti- algal ultima & high performance water based paint long lasting silk finish over a coat of waterprofing coat formulated with elostemric & resilient acrylic polymer primer & reinforcing synthetic fiber including rubbing the surface by emrry paper etc complete all as specified and directed. Note:- It includes cost of vegitation, plants etc remove if any on the wall surfaces and applying by spray Machine.
S & F any height (above floor level) stainless steel (Grade 304) hollow round or square pipe of any dia / size fixed as in posts/ riling with knock down fixing system & top mounted round blaster made of 38 to 50mm dia stainless steel 304 grade, channels, plates etc including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete including fitting the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size sutaible arrangement as per approval of Engr- In- Cahrge including taking down old railing and make good the surface as required complete all as specified and directed. Note:- The distance between vertical stainless steel posts should as site requirement centre to centre.
Taking down point wiring with aluminium conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator etc, and making good to the disturbed surfaces of walls/ floor etc to macth with existing surfaces including white washing/colour washing/ distempe-ring to match with existing wall/floor/ceiling finishes complete all as specified and directed.
Taking down sheet metal enclosure, DB, main switch etc and making good distrubed sufaces to match with exisiting surfaces complete all as specified and directed.
Taking down sub main wiring of any size/ capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces complete all as specified and directed.
M&L for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm modular boxes sunk on wall for mounting of any type modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch. Note:- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
All as per item No 56 above but One ceiling/exhaust fan point controlled by oneway switch and regulator complete all as specified and directed.
All as per item No 56 above but One 3 pin 5 amp socket outlet point on the same board with other switches complete all as specified and directed.
All as per item No 56 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per item No 56 above but wiring with 4 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 16 amps power point complete all as specified and directed.
M&L for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of size 2x4.0 Sqmm with earth wire of 1x4.0 Sqmm complete all as specified and directed. Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same.
All as per item No 61 above but of size 2x 2.5 Sqmm with earth wire of 1x 2.5 Sqmm complete all as specified and directed.
S&F in repair for switch modular type single pole one way 6 amp 1 module 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F in repair for socket modular type single pole one way 6 amp 2 module 2/3 pin 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F in repair for switch modular type single pole one way 6/16 amp 3 pin 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F for socket modular type single pole one way 6/16 amp 2/3 pin 2 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
S&F in repair ceiling rose surface type three terminals 5 amps complete all as specified and directed.
S&F in repair lamp holder insulated body with back plate for angle/batten fittings, complete all as specified and directed.
S&F in repair 0-4 step 2 module modular type electronic regulators for ceiling fan 1200/1400 mm sweep, 240 volts, 120 watts single pole complete all as specified and directed.
S&F in repair 18/20 Watt LED Tube light fittings complete with aluminum body including tube rod, driver with not less than 2000 Lumen O/P and I/p rated voltage 240V connecting with 2 core 1 sqmm copper conductor cable complete all as specified and directed. Make & Model:- Philips Astra Line 20W/ CG -LCTLN-18/20W-CDL /Bajaj BCLSB 18 W.
S&F in repair in repairs LED baton fitting 2' length including drivers having energy consumption, 9-11W ,230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed. Make & Model:- Philips Slim line 9W, CG- LCTLN-9/10WCDL, Surya SLE BT 10/Bajaj BCLSB 10 W.
S&F in repair 7 Watts LED lamp cool day light 240 Volts, 50Hz, as in repairs, complete all as specified and directed.
S&F in repair round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders LED lamp suitable for roof ceiling including connecting up with three core flexible copper complete all as specified and directed. Make:- CG Cat part No CDR 211-09-30-SL-NWH, or equivalent in Philips/ Wipro.
S&F in repair LED flood light luminaires of capcity 70 watts with PDC housing with IP 66 protection. Heat resistant tempered glass for protection with 5 KV surge protection complete with driver, suitable size GI bracket,1.5 sqmm 3 core multistranded copper wire for connection from street light / High mas fitting to junction box,fixing with 30x5 mm Flat Iron clamps nuts, bolts, washers and fixing accessories including taking down old unserviceable 150 watts Flood light fitting all as specified and as directed. Make :- Cat No. LSFO - 200- CDL/60 of CG /Philips Cat No. BVP410LED210CW HENBFG53XT/wipro Cat No. LF07-282-XXX-50-V5
S&F in repair ceiling fans, complete with three blade, down rod, accessories 230 V, 1200mm sweep with Squirrel cage induction motor complete all as specified and directed.
S&F in repair sheet metal enclosure triple pole & neutral for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting, double door complete all as specified and directed.
S&F in repair sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting, double door complete all as specified and directed.
S&F in repair curve miniature circuit breaker (MCB) of Tripal pole & neutral 415 V 10 KA 'C' volt 40 to 100 amps and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S&F in repair curve miniature circuit breaker (MCB) of single pole & neutral 240 V 10 KA 'C' volt 40 to 63 amps and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
S&F in repair curve miniature circuit breaker (MCB) of single pole 240 V 10 KA 'C' volt 5 to 32 amps and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
M&L for earthing complete with galvanised steet earth plate electrode 600x600x6mm thick burried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanised earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :- (a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 type B-1 (c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric (d) Funnel with watering pipe of GI 20mm nominal bore light grade and copper lugs etc all as specified. (e) 15mm nominal bore meduim grade GI protec-tion pipe 7.50 metre long for protection of earthing lead. (f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion.
Excavation in trenches for foundation, laying of cables, poles and stays etc exceeding 1.5 metre wide and exceeding 1.50 metre deep and getting out in soft/loose soil complete all as specified and as directed.
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed.
S&F Double wall Corrugated High Density Polymer Ethyl (HDEP) pipe for laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches,wall, floor , pole including bends, sockets and other connected accessories complete all as specified and directed.
Supply and laying in trenches or fixing in walls / pole orpoles or drawing through pipes XLPE insulated, scrrened PVC bedded galvanised steel strip or wire armoured electri power cables (heavy duty) with almunium conductor 1100 volts grade cross sectional area 16 sqmm 4 core including testing after laid and joined complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.
Dismentling of unserviceable PCC pole of any size complete all as specified and directed
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.with 30x5 mm flat iron clamps, nuts, bolts, washers and fixing accessories including taking down old unserviceable fitting complete all as specified and directed.
Supply & installation of steel octagonal decorative poles 5 mtrs long complete with cast iron base plate, bolts, nuts and screws fixing ,including on sutable pole foundation with street light brackets sutable size and cable terminal junction boxes nut bolts, washers, terminal block and glands suitable for 16 Sq mm core cable including 6 amps MCB SP complete anchor bolts and nuts as specified and directed including plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete for stay, poles etc complete all as specified and directed. Note:- Dimensions of foundation concrete will be (LxBxD): 0.5m X 0.5m X 1.5m below ground level and 0.5m X 0.5m X 0.3m above ground level.
S&F 3 core 1.5 sqmm PVC insulated, PVC sheathed, weather proof multistranded copper conductor cable, 1100 volts grade, drawn through GI conduit, on pole complete all as specified and directed.
S&F LED Bollard fitting inverted pyramid tripod with soft 360 degree light and IP 65 protection including drivers, complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size of 230 V 50 Hz from fitting to junction box fitted to PCC structure complete all as specified and as directed. Make:- Bajaj; Cat No BOS 600W 9 W LED / Philips BCP 400 LED 05 PCW PSU GRS1./ CG LBLTW-10-CDL .
M&L for PCC 1:3:6 Type C-1 (using 20 mm graded stone aggregate), as in coping of poles, including necessary form work weathering slightly or chamfered angles, throuting exposed surfaces finished even and fair, complete all as specified and as directed.
S&F thermoplastic cable junction boxes IP 55/IP65 with metric knockout for cable entry of size 200 x 160 x98 mm fixing on pole with 30 x 5 mm MS clamps, nut bolts, washers, terminal block and glands suitable for 16 Sq mm core cable including 6 amps MCB SPN complete all as specified and directed. Make:- HENSEL, Neptune, Sintex
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.78,425.00]
DEESHA CONSTRUCTIONS
M/S L M Chourasia
Meet Road Lines
Shri Mohan Brother
M/s. Nikhil B Nistane
NORTH INDIA PEST CONTROL
RAJ ENTERPRISES
MAHARASHTRA ENTERPRISES
Bidder Name
Meet Road Lines
M/S L M Chourasia
RAJ ENTERPRISES
DEESHA CONSTRUCTIONS
Shri Mohan Brother
MAHARASHTRA ENTERPRISES
M/s. Nikhil B Nistane
NORTH INDIA PEST CONTROL
S D WAGHAMSHI
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .