Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.7 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹25.7 L+₹7.0 L (37.1%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹25.9 L+₹7.1 L (38.1%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not recommended since not enlisted in required category |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
23 Nov 2022, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
MODIFICATION OF BLDG NO-158 FOR X-RAY ROOM AND OTHER CONNECTED B/R AND E/M WORKS AT AF STN FARIDABAD AND AOR OF GE (AF) FARIDABAD
2022_MES_559850_1
GE (FBD)/AF-62/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Faridabad
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) FARIDABAD
₹54,000
Yes
27 Dec 2022
26 Oct 2022
25 Nov 2022
26 Oct 2022
23 Nov 2022
9 Nov 2022
26 Oct 2022 - 2 Nov 2022
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 250 metre and depositing where directed at a level not exc 1.5 meter above starting point complete all as specified and directed by Engineer-in-Charge.
M&L, Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
M&L, Cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing, foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning under floors as in foundations including watering and consolidation, complete all as specified and directed by Engineer-in-Charge.
M&L, Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in kerbs or mud stops, rounded or chamfered on edges including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment over 25 mm thick levelled sand cushioning etc, complete all as specified and directed by Engineer-in-Charge. (Sand shall be measured and paid seperatly )
Excavation in trenches n. exc 1.5 mtr wide & n. exc 1.5 mtr depth; for foundations, etc. n. exc. 10 sqm on plan and n. exc. 1.5m in depth and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
Demolition brick work or stone/boulder masonary,built in cement mortar or cement lime mortar including all quions, arches pillars,etc but ashlar facing dressed stone work and precast concrete articles and disposal of debris to outside the station where suitable for contractor complete all as specified and as directed.
M&L, Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 15 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L, Preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
S&F for framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or framed into spikes; framed guard bars; barred iron doors; welded to existing frame, ladders, framed balusters; walk ways; railings; framed work of water tanks and similar work confoming to Fe-290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
M&L for structural steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drillled for fixing of steel sheeting or other covering. Doors to be prepared for hanging or sliding with and incl either hooks and hinge or steel hanging door fittings and similar works confirming to Fe-290 Gde E-165 and fixing complete all as specified and directed by Engineer-in-Charge.
Cutting holes in brick walls in cement mortar exc half brick but not exc one brick for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B-1 as required and depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall, complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, type B-1 (Using 20 mm graded aggregate) as in, inserting hold fast, bed plates, pintle blocks, ancho-rage blocks, bonders(for stone walling) corbels, brackets, etc (of any section indicated) with plain fair faces, including chamfers, weatherings, throating etc, complete all as specified.
Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Rendering 12 mm thick cement plaster in cement mortar (1:6) on fair faces of brick works or concrete surfaces , finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered or un plastered wall surfaces of any description and applying two coats of oil bound distemper over a coat of Chalk whitening, complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris to outside the station where suitable for contractor complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and directed by Engineer-in-Charge.
Taking down chowket or frame with shutter (without taking of shutter from frame) exc 1.5 sqm but not exe 4.00 Sq m each each and making of site/wall good for fixing of new door/window as per suitable size of new window / door complete all as specified and directed by Engineer-in-Charge.
Dismantaling of old aluminium partition with door shutter, board , glass and all fittings complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 (40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material and labour for suspended false ceiling consisting of suitable anodised aluminium sections of ‘Tee’ of size not less than 22.50 x 22.5 x 0.5 mm Angle of size 22.5 x 22.5 x 0.5 mm & FI as per std engineering practices with prepainted/laminated ‘E’ board ceiling boards 6 mm thick in grid of 605 x 605 mm including cutting holes and making good holes for main joist, suspending with 6 mm dia GI wire to roof trusses, purling & rafters etc complete all as specified and directed by Engineer-in-Charge.
S&F for Stainless Steel Lead proof single leaf door opening size of 750mm X 2000 mm consisting of 1.2 mm thick SS frame and 0.8mm SS 304 steel with 2 mm lead sheet including all fittings and fixtures all as specified and shown on drawing no.-01, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Stainless Steel Lead proof double leaf door opening size of 1500mm X 2000 mm consisting of 1.2 mm thick SS frame and 0.8mm SS 304 steel with 2 mm lead sheet including all fittings and fixtures all as specified and shown on drawing no.-02 complete all as specified and directed by Engineer-in-Charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and complete all as specified and directed by Engineer-in-Charge. (Note:-Necessary items like screws, rubber/ neoprene gasket etc as per site requirment are included in this item but Only weight of aluminium sections will be calculated for payment )
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providingand fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required including all Fittings shall with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings complete all as specified and directed by Engineer-in-Charge. NOTE:- Floor spring/door closer ,Glazing& panelling shall be measured and paid separatly. (Note:-Necessary items like screws, rubber/ neoprene gasket etc as per site requirment are included in this item but Only weight of aluminium sections will be calculated for payment )
M & L for fixed in repair 12 mm thick both sides prelaminated Particle board, exterior grade, fixed with screws to timber frame work in cup board shutters/ shelves complete all as specified and directed by Engineer-in-Charge.
S & F in repair 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sq. M in each pane complete all as specified and directed by Engineer-in-Charge.
Providing plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates, 25mm thick, as in floor/sub base and finishing concrete surface fair and even to receive top floor finishes complete all as specified and directed by Engineer-in-Charge.
Providing screed bed or bedding layer, 15 mm thick, in cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
Rendering, 10 mm thick, in cement mortar 1:4, on wall surafaces, as backing coat to tiles complete all as specified and directed by Engineer-in-Charge.
Glazed ceramic tiles, 300/350 x 450 x 7mm thick, glossy finish, conforming to Group B-III of IS-13712, first quality, of approved dark or light colour, laid on vertical surfaces such as skirting or dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L forVitrified Ceramic coloured tiles of approved shade and pattern, 600 x 600 x10-12mm thick, conforming to Group B-IIA of IS-13712, first quality, laid in floors or in walls as skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for Lead Free Radiation shielding Tiles to be fixed on wall of X Ray rooms of size 1ft X 1ft with 1mm lead equivalence @ 100kvp (+/- 5%) Thickness of Tile should be 13 to 15 mm (appx weight of each tile is 2.5 to 3 kg) of approved colour . Overlapping/Interlocking in tiles to be provided for leak proof shielding when fixing and tile should be BARC tested and certified, set and jointed in neat cement slurry/ cemical and pointed in white or coloured cement to match all as per company instructions/ guidelines complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 20 mm thick (of any type ) (table runned and polished ) in floors steps , jamns, pillars,window-cills,cooking plateforms and vertical surfaces bedded and jointed with grey cement slurry and pointing in white ciment (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
M&L for Providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate set in CM 1:4in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, eatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and directed by Engineer-in-Charge.
M&L TMT bars 10 mm dia & over cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (not less than 0.9 mm dia) or securing with clips quality conforming complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement with WPC @ of 3% of weight of cement complete all as specified and as directed by the Engineer-in-Charge.
M & L for preparing new surfaces of walls, distempering 2 coats with oil emulsion distemper white or tinted over one coat of wall care putty complete all as specified and as directed by the Engineer-in-Charge
M&L for complete removal of existing treatment on walls including preparing old plastered surfaces and applying two coats of oil bound distemper complete all as specified and directed by Engineer-in-Charge.
M & L for preparing old Surfaces of any description over 10cm girth or width, not otherwise described three coats of dark black synthetic enamal paint paint complete all as specified and as directed by the Engineer-in-Charge
M&L for Complete removal of existing treatment in old plastered walls including preparation of old plastered surfaces and applying two coats of cement based paint in buildings upto ground plus three floor) complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment in old plastered walls including preparation of new or old plastered surfaces and applying two coats of weather proof emulsion (Apex Ultima) of electric blue or white colour over a coat of exterior wall care putty in (projections of column/wall/edges of chajja, roofs and other narrow locations in buildings upto ground plus three floor) complete all as specified and directed by Engineer-in-Charge.
M & L 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregates in sub base complete all as specified and directed by Engineer-in-Charge.
Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
S&F Rotational molded polyethylene water storage tanks 3 layered, ISI marked (cylindrical vertical with threaded lid) hoisted and fixed in position all as specified in SSR Part-I of Capacity 500 litres with GI Tank Nipple inlet and outlet 20mm complete all as specified and directed by Engineer-in-Charge.
S&F Ball valve, high pressure with of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or fixed of size 20 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repair Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings complete all as specified and directed by Engineer-in-Charge.
S&F in repair Bib taps, long body, fancy type, chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm, fixed in repair, complete all as specified and directed by Engineer-in-Charge.
S&F in Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F in Harrison rails,anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc.at site complete all as specified and directed by Engineer-in-Charge.
S&F for UPVC Pipes (SCH-80) 50mm dia for waste water outlet complete all as specified and directed by Engineer-in-Charge.
S&F for UPVC Pipes (SCH-80) 50mm dia stop valve complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) pipes, 75 mm external dia single socketed in any length with rubber joints, fixed to walls with PVC brackets/clamps complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) bends suitable for 75 mm external dia complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply, lay, spread in trenches river sand including spreading, levelling, punning for cushioning of cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, LT underground cable of size 4 core 10 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc.laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, LT underground cable of size 4 core 35 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc.laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed by Engineer-in-Charge.
S&L GI tubing light grade 40 mm bore intrenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all as specified and directed by Engineer-in-Charge.
Taking Down carefully Copper/aluminium Point Wiring (light, fan,socket or Power) complete,(fittings Such as switches, ceiling roses, pendents, regulators sockets etc, to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminum two core sub main wiring of sizes 6 Sqmm /4 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring in repairs complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 1.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one light/Fan point controlled by one,one way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 74 mentioned here-in- before but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
Switch piano, flush type single pole, one way 6 Amp complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,ceiling rose surface backlight, 65 x 50 mm three terminals complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring in repairs complete with 2.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 2.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one 15 Amps socket outlet independent board complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 3 pin 6 Amp complete all as specified and directed by Engineer-in-Charge.
S&F piano switch,in repairs, flush button single pole one way 16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 3 pin,6 and 16 Amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 12 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed by Engineer-in-Charge.
Supply and fix of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB Triple pole and Neutral , 415 volts, 63 Amps 10 KA, 'C' grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SPN 6 to 32 Amps, 240 Volts,"B" grade complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volts, 6 to 32 Amps 10 KA complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing 40 watts 5700 K Recess mounting Backalite LED Panel having white Polycarbonate body & Aluminium plate heat sink, high quality PMMA diffuser and HPF driver suitable for Gypsum, POP, Armstrong and Grid ceiling and complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED , Tube light fitting 20 W, 6500K Intenso AX LED batten aluminium profile self ballasted surface mounted LED Batten extruded aluminium body with PC diffuser in unic shape. >180º wide light distribution. soft glare free light complete accessories prewired and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fix wall mounted cabin fan super high speed portable 450 mm sweep,220-240 volt AC,50 Hz sigle phase with Thermal overload protected motor complete all as specified and directed by Engineer-in-Charge.
Supply and fix Ceiling fan 1200 mm sweep, single phase, 230 Volts, AC, 50 Hz and connecting up including provison of cabe from ceiling rose/connector to Ceiling fan complete all as specified and directed by Engineer-in-Charge.
Supply and fix single phase Refresh air-HD Metal Industrial energy efficient heavy duty motor Exhaust Fan 300 mm sweep 1400 RPM and connecting up and provison of cabe from ceiling rose/connector including making hole in existing any type of wall and finshing the disturbed surface for fixing of Exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with 5 star rating and EER 3.2 of capacity 2.0 Ton including necessary sheeting to protect out door unit from climatic conditions complete all as specified and directed by Engineer-in-Charge. NOTE : (a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces. (b). The cost of copper tubing of size 5/8" and 1/4" with suitable insulation up to a length of 4.5 mtr is deemed to be included in the unit rate quoted. Cost of copper tubing of size 5/8" and 1/4" with suitable insulation beyond 4.5 mtr will be measured and paid separately under the relevant item.
Supply and fix voltage stablizer for automatic operation/single phase AC supply 230V 50 Hz naturally air cooled indoor type designed for input variation between 170V to 270V with output valtage stablizer at 230V with accuracy of (+) or (-) 2.50% and capacity 5 KVA. Make - V-Guard model No. VG500 or equivalent complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with 2 runs of single core 6 Sqmm PVC insulated copper conductor cable, unsheathed LT 1100 Volts grade drawn through and including non metalic rigid concealed PVC conduit and accessories fixed on wall/roof including one run of 6 Sqmm of PVC insulated copper cable for earth continuity complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with 4 runs of single core 10 Sqmm PVC insulated copper conductor cable, unsheathed LT 1100 Volts grade drawn through and including non metalic rigid concealed PVC conduit and accessories fixed on wall/roof including one run of 10 Sqmm of PVC insulated copper cable for earth continuity complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4 mm GI earth continuity conductor including 15 mm bore pipe Light grade for protection of lead by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to maint switch control board upto 7.5 mt away from earth electrode all as shown as per plate No 05 of SSR part - I including necessary earth work, PCC 1:3:6 type C1 chamber, RCC cover slab of 50 mm thick 1:2:4 with 8 mm CTD 140 mm C/C with suitable handle, watering pipe 20 mm dia light grade pipe with funnel, charcoal, salt and testing on completion and including taking old unserviceable earthing with connected items complete all as specified and directed by Engineer-in-Charge.
Material and Labour for making new hole of 150 mm dia and 3.0 mtr depth or excvation of earthing size 1.5x1.5x3.5 mtr one pit and supply and filling in micronite(bentonite) base earthing enhancement micronite compound (0.001 ohms mtr conductive grounding granuals 25 kg in each pit) and copper electorode rod 17.7 mm dia and 3 mtr long as per relavent IS and to achieving the desired earth result complete all as specified and directed by Engineer-in-Charge. (Each earth pit shall include minimum 25 kg NABL Lab certified micronite aggregate and cement 12.5 kg for filling bore hole with water mixed in 1:2 ratio (two parts of micronite aggregate compound and one part of cement), so also achieve eath resistance below 1 ohm including PVC pit box with cover shall be deemed to be inclusive in the quoted rates. In case of non achieving of desired results the same shall be re-done by the contractor on his own cost.
M&L test point terminal block made of gun metal or phosphorus bronze/brass size (75 x 75x 10 mm) drilled and 3 Nos brass screwed 8 mm dia, 10 mm long hex. Head screw complete including GI fabricated test point box sixe 150 mm x 100 mm x 75 mm height with front openable made out of not less than 0.6 mm thick PGI sheet including painting complete all as specified and directed by Engineer-in-Charge.
Supply and fix copper strip 20x3.15 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed by Engineer-in-Charge.
Point wiring complete with1.5 sqmm single core PVC insulated heavy duty ISI marked FR, unsheathed FRLS cable 1100 volts grade with multistranded copper conductor drawn through ERW conduit with all accessories fixed to the surface of walls/roof/ floors / ceiling etc., MS terminal boxes 60 mm deep concealed in walls covered with plastic laminated top cover sheet 3.0 mm thick fixed with cadmium plated iron screws etc incl 1.5 sqmm PVC insulated, unsheathed copper conductor FRLS cable 1100V grade as earth continuity conductor & connecting to common earth dolly. for one light/Exhaust Fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling rose surface bakelite 65x50mm 3 terminals complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
Supply and fix Fluorescent LED tube light fitting 1 x 16/20W flameproof type made of Die cast aluminium alloy housing with heat resistant glass/heat resistant dome glass/extrenal reflector with CMRI certified LED FLameproof well glass luminaire for gas/vapour grtoup of IIA & IIB ans Zone 1 & IP65 protection etc. complete with all accessories prewired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
S & F flame proof exhaust fan 305 mm (12)" sweep heavy duty 1440 RPM, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.5 sqmm (16/0.2 mm) from ceiling rose to fan including writing MES N0. 2 cm height with synthetic enamelled black paint and connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
M & L for Provision of hole on any type of wall for fixing of the exhaust fan and connecting with the ceiling rose complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way Double door with 200 Amps rated busbar including flushing the DBs inside the walls and making good the disturbed surface also matching with the existing surface complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SPN 6 to 32 Amps, 240 Volts,"B" grade complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volts, 6 to 32 Amps 10 KA complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with 2 runs of single core 4 Sqmm PVC insulated copper conductor FRLS cable, unsheathed LT 1100 Volts grade drawn through ERW conduit with all accessories fixed on wall/roof including one run of 4.0 Sqmm of PVC insulated copper unsheathed copper conductor Multistranded FR cable 1100V grade as earth continuity conductor cable for earth continuity complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6 mm thick burried directly in ground ( earth pit not less than 2.25 mtr below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of galvanized earth lead wire 4mm dia connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, provision of 15mm dia GI pipe light grade for earth wire protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe perforated medium grade for watering arrangement and PCC 1:3:6 type C1 chamber, MS funnel, wire mesh, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos,8mm dia high strength deformed steel TMT bars on both ways, including necessary exavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc.50m, provision of charcoal and salt complete all as shown in electrical plate No.3 of Schedule Part-I 2009 complete all as specified and directed by Engineer-in-Charge. Note : Cost of GI earth lead wire and GI protection pipe upto 7.5 m length shall be deemed to be included in the rate quoted for this item.
Supply and fix Aluminium strip 25x3 with saddles and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed by Engineer-in-Charge.
Supply and fix Test Point Terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal head screw including removing the existing u/s test point terminal bloch complete all as specified and directed by Engineer-in-charge. .
Supply and fix Air termination, single pointed alluminium rod 12mm dia and 900mm long including floor coupling for joint the lightening conductor complete all as specified and directed by Engineer-in-Charge. Note : The conductors and termination point should not touch the buildings surface and quoted rate is deemed to the inclusivee of fixing arrangements.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed by Engineer-in-Charge.
Material and Labour for making new hole of 150 mm dia and 3.0 mtr depth or excvation of earthing size 1.5x1.5x3.5 mtr one pit and supply and filling in micronite(bentonite) base earthing enhancement micronite compound (0.001 ohms mtr conductive grounding granuals 25 kg in each pit) and copper electorode rod 17.7 mm dia and 3 mtr long as per relavent IS and to achieving the desired earth result complete all as specified and directed by Engineer-in-Charge. (Each earth pit shall include minimum 25 kg NABL Lab certified micronite aggregate and cement 12.5 kg for filling bore hole with water mixed in 1:2 ratio (two parts of micronite aggregate compound and one part of cement), so also achieve eath resistance below 1 ohm including PVC pit box with cover shall be deemed to be inclusive in the quoted rates. In case of non achieving of desired results the same shall be re-done by the contractor on his own cost.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to and including earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe for watering and funnel, GI Pipe medium grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover complete all as specified and directed by Engineer-in-Charge. Note (i): Earthing lead from earth plate to test point upto 7.5 Mtr is deemed to be included.
M&L test point terminal block made of gun metal or phosphorus bronze/brass size (75 x 75x 10 mm) drilled and 3 Nos brass screwed 8 mm dia, 10 mm long hex. Head screw complete including GI fabricated test point box sixe 150 mm x 100 mm x 75 mm height with front openable made out of not less than 0.6 mm thick PGI sheet including painting complete all as specified and directed by Engineer-in-Charge.
Supply and fix copper strip 20x3.15 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed by Engineer-in-Charge.
laxmi enterprises
Shakashi Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .