| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC 521 UBI ROAD SINGRAULI SINGRAULI SINGRAULI MADHYA PRADESH 486889 UDYAM MP 11 0000528 23ABQPC9013J1ZP R M | SINGRAULI | MADHYA PRADESH | 486889 | ₹8.5 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹8.9 LRejected-AOC NEAR PREMKANTA GAS AGENCY WARD NO 4 OLD DUDHICHUA ROAD MAIN ROAD SINGRAULI DISTT SINGRAULI M P PIN 486889 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486889 | ₹8.9 L | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹8.9 LRejected-AOC 00 BHADAR TIKARMAFI BAZAR SULTANPUR UTTAR PRADESH 227413 | AMETHI | UTTAR PRADESH | 227413 | ₹8.9 L | L3 | Rejected-AOC L3 bidder |
| Sl No | Description | Qty | Unit | Sandeep and Co. L1 | M/s. Dev Enterprises L3 | Biswas Engineering Works L2 |
|---|---|---|---|---|---|---|
| 1.00 | Overhauling, checking and testing of mechanism with changing of accessories as required. | 2 | Nos. | 5,000 ₹10,000 | 8,500 ₹17,000 | 8,000 ₹16,000 |
| 2.00 | Repairing of interrupter and setting of SF6 | 2 | Nos. | 5,000 ₹10,000 | 11,000 ₹22,000 | 8,000 ₹16,000 |
| 3.00 | Complete wiring of control circuit of the breaker with ferrules and lugs (All material to be supplied by contractor) | 2 | Nos. | 4,800 ₹9,600 | 9,000 ₹18,000 | 9,500 ₹19,000 |
| 4.00 | Filling of SF6 gas charges | 2 | Nos. | 3,300 ₹6,600 | 6,000 ₹12,000 | 4,000 ₹8,000 |
| 5.00 | Repairing and maintenance of control relay panel (CRP) (All material to be supplied by contractor) | 2 | Nos. | 10,000 ₹20,000 | 10,000 ₹20,000 | 15,000 ₹30,000 |
| 6.00 | Nut Bolt with washer as per requirement | 1 | LS | 5,000 ₹5,000 | 1,200 ₹1,200 | 2,500 ₹2,500 |
| 7.00 | Interurupter testing | 2 | Nos. | 4,200 ₹8,400 | 6,000 ₹12,000 | 1,500 ₹3,000 |
| 8.00 | Supply and fixing of closing coil assembly (Closing coil of 110 V DC) (as per sample) | 2 | Nos. | 3,000 ₹6,000 | 3,000 ₹6,000 | 1,950 ₹3,900 |
| 9.00 | Supply and fixing of trip coil assembly (Trip coil of 110 V DC) (as per sample) | 2 | Nos. | 3,000 ₹6,000 | 2,000 ₹4,000 | 2,100 ₹4,200 |
| 10.00 | Supply and Fixing of Auxilary Contractor 4NO+ 4NC | 4 | Nos. | 1,500 ₹6,000 | 5,000 ₹20,000 | 1,500 ₹6,000 |
Tender Value
₹10.8 L
EMD Value
₹13,500
Closing Date
15 Nov 2025, 10:00 amClosed
SO(EnM), Block-B Area
Office of SO(EnM), Block-B Area
Overhauling and repairing of 6.6kV and 33kV Circuit Breaker(SF6 and VCB) of Block-B Project
2025_NCL_346667_1
NCL/BB/EnM/Tender/25-26/20 dt. 03.11.2025
Open Tender
Miscellaneous Works
60 days
Block-B Project
Please refer Tender documents.
4 documents required · 4 mandatory
₹13,500
2 Jan 2026
3 Nov 2025
17 Nov 2025
3 Nov 2025
15 Nov 2025
4 Nov 2025
3 Nov 2025 - 10 Nov 2025
Amount
Overhauling, checking and testing of mechanism with changing of accessories as required.
Repairing of interrupter and setting of SF6
Complete wiring of control circuit of the breaker with ferrules and lugs (All material to be supplied by contractor)
Filling of SF6 gas charges
Repairing and maintenance of control relay panel (CRP) (All material to be supplied by contractor)
Nut Bolt with washer as per requirement
Interurupter testing
Supply and fixing of closing coil assembly (Closing coil of 110 V DC) (as per sample)
Supply and fixing of trip coil assembly (Trip coil of 110 V DC) (as per sample)
Supply and Fixing of Auxilary Contractor 4NO+ 4NC
Supply and Fixing of Auxilary Switch 6NO + 6NC
Labour charges for checking, testing and commissioning of breaker and CRP along with installation of indicating elements
Overhauling, checking and testing of mechanism with changing of accessories as required.
Supply of closing coil assembly (Closing coil of 110 V DC) (as per sample)
Supply of trip coil assembly (Trip coil of 110 V DC) (as per sample)
Complete wiring of control circuit of breakers with ferrules and lugs (All material to be supplied by contractor)
Repairing and maintenance of control relay panel (CRP) (All material to be supplied by contractor)
Supply of spring charging motor, 220 V AC, 420 watt as per sample
Vacuum Bottle- 1250 Amp- 26KA (Material Code-6100000811)
Supply and Fixing of Auxilary Switch 6NO + 6NC (Material Code-6100000815)
Supply and fixing of shunt Trip coil 220 volts DC
Supply and fixing of VTC/charging coil assembly 230 Volts DC
Rectifier bridge unit 63 A, 600 PIV
Auxilary contactor 4 NO + 4 NC
Box control unit for vaccum contactor control voltage 220 volt AC/DC
Charging Handle
Earth leakages relay coil 110-220 volts AC with test and reset features Range 0.3 to 7.8 Amp, Make JVS, Prok DVS or equivalent
Supply and fixing of current transformer (100/50/ 30/5, 6.6 KV
Supply & fixing of voltmeter 6.6 kv
Supply & fixing LED indicating lamp RED 240 volts AC/DC
Supply & fixing LED indicating lamp GREEN 240 volts AC/DC
Supply & fixing LED indicating lamp YELLOW 240 volts AC/DC
LED indicating lamp AMBER 240 volts AC/DC
Wiring wire 2.5 sq. mm Copper
Vacuum Bottle- 1250 Amp- 26KA (Material Code-6100000811)
Breaker overhauling
Installation, testing and commissioning of item no 01 to 17 in existing panel @10% of the material cost Note: Contractor should posses all standard equipment for testing of relays including following: a) 3 phases secondary injection kit with range 1 Amp to 500 Amps or above b) HT Pressure test c) Caliberation to be done in respect of standard equipment at govt. Laboratories and should posses test certificate for all testing equipmentg at the time of test
Total impact of GST for the purpose of CTC
Biswas Engineering Works (BID ID -1196717)
M/s. Dev Enterprises (BID ID -1197098)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.59 MB
BOQ_359353.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid