Executive Engineer Electrical SKIMS
SKIMS Soura Srinagar
Fresh Electrification of 1st 2nd Hall and corridor of CSSD at SKIMS Soura
2021_SKIMS_154489_1
eNIT NO.SIMS/HEE/E/ET/38 of 2021-22 Dt. 22-12-2021
Open Tender
Electrical Works
Item Rate
30 days
SKIMS Soura
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
As Described in SBD
Exempted
31 Jan 2022
22 Dec 2021
5 Jan 2022
22 Dec 2021
3 Jan 2022
22 Dec 2021
270 days
Amount
SITC 400 A TPN MCCB, 35 kA breaking capacity, alongwith 1 Nos, with spreader links and to be installed at Sub Station
Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system ,fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks with sleeved TPN Aluminum Bus bars and GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade with interconnections etc as per specifications, as required and as below. All Panel shall be complete with power & control wiring, danger & inscription plate, Lifting hooks etc. INCOMER 1 No. 400A FP MCCB, 50 kA breaking capacity with microprocessor release and adjustable setting and with rotary handle.with ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB CONTINUED BELOW......
METERING & INDICATION set of R,Y,B phase indicating lamps (1 Set) 400/5A Class - 1.0, 15 VA Burden CT's for metering ON / OFF indicating lamps with MCB as backup protection. Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of Accuracy-1 as specified. (01 No.) BUS-BAR 1 Set of 500 A TPN Aluminum bus bars with colour coded heat shrinkable PVC sleeves having current density of bus bar. OUTGOINGS 200 A TPN MCCB, 35 kA breaking capacity. =3 Nos 1 Nos. 100 A TPN MCCB, 25 kA breaking capacity = 01 No 2 Nos. 63 A TPN MCB, 10 kA breaking capacity. = 02 No 2 Nos. 40 A TPN MCB, 10 kA breaking capacity. = 02 No MCB single pole 6 A to 32 A =12 Nos
Supplying and fixing of 8 way (4 + 24), Double door ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs along with 4 P 160A MCCB, 36KA as Incomer (but without Outgoing MCB and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
MCB single pole 6 A to 32 A
16 A TPN MCB, 10 kA breaking capacity.
32 A TPN MCB, 10 kA breaking capacity.
Providing and laying of spans of 3 ½ core XLPE Al. cable Armored of various sizes as mentioned below as fresh ones. Of 1.1KV grade complete as specified in Technical Specifications of SBD.
300 mm sq. 3 ½ core
185 mm sq. 3 ½ core
Fabrication,supply and erection of Iron Hooks fabricated from Angle Iron of size 40x40x5 mm
Providing & fixing of fresh lighting point (5-6 amp) exposed,using double locked PVC channel 25x2 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire FRLS (P+N+E) complete with P/F of switch 5/6 amps F/T to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point.
Wiring to be carried out for fresh heating point in surface manner through pvc conduit of 25 dia. 2 mm thick using multi strand 3 x 2.5 mm.sq pvc insulated copper wire FRLS complete with P/F of switch socket combine 15/16 amps 5 pin F/T to be fitted on Bakelite sheet suitable size, M.S/Wooden box, rowel plugs & screws etc. complete Point with civil work .
Circuit wire to be laid / Replacement of damaged wire as per site requirements using multi strand pvc insulated copper wire FRLS
1.5 mm 2 multi strand pvc insulated copper.
2.5 mm 2 multi strand pvc insulated copper.
4 mm 2 multi strand pvc insulated copper.
6 mm 2 multi strand pvc insulated copper.
10 mm 2 multi strand pvc insulated copper.
16mm 2 multi strand pvc insulated copper.
Providing and making of end termination of the following wires including thimbling, crimping tapping, testing and connecting as per site requirements
Supply and fixing of following size of medium class PVC conduit 2mm thick along with accessories like with rowel plugs , screws ,sadlles ,bends etc complete as required at site . (in surface manner)
Supply and Fixing Double locked medium duty pvc channel 25x 2mm. along with accessories like rowal plugs, screws complete as per site requirements.
Providing, installation, testing and commissioning of well glass luminaries 35 - 40 watts having high pressure die cast aluminium housing with polycarbonate anti lare diffuser , IP 66, with burning hrs =50000 and system lumens /watt >110 .
SITC of Wall mount fans 400 mm with Plastic Body as specified below 1.Motor Brushless DC (BLDC) 2.Governing standard I.S.2997 (Latest) 3.Power Consumption: Approx. 100 Watts 4.Power supply Single phase AC 230V, 50Hz 5.Speed: 1200 -1400 rpm with regulator 6.Sweep: 400 mm 7.Air Flow: 72-80 m3/min. 8..motor protection through thermal 9.overload protection device 10.It should have minimum 3 levels of speed control. Features: Suitable for mounting on walls with easy mounting arrangements, Noise level shall be within limits adjustable upward and downward tilt mechanism
Supply installation testing and commissioning of 300 mm Bird guard to pretect fan in running condition ,Double ball bearing with Heavy duty motor Rated speed = 1400 RPM . RAte voltage -220 to 240 Volts Air delivery 1600 Mhr/min
Supply installation testing and commissioning of 450 mm Bird guard to pretect fan in running condition ,Double ball bearing with Heavy duty motor Rated speed = 1400 RPM . RAte voltage -220 to 240 Volts Air delivery 1600 Mhr/min
Making of Earthing point with 2 inch Dia GI pipe, B Class, caged in 6 inch GI pipe, Class B in CCM Compoud and 10 feet Deep, as earthening electrode. The pit is to be dug using borewell and covered with 10x10 inch manhole cover. (Drawing enclosed)
M/s KASH ENGINEERS AND ASSOCIATES
M/S SHAH ELECTRICALS and MECHANICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .