Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.2 LAccepted-AOC | 1 | Accepted-AOC Accepted | |
| 2 | 2₹19.0 L+₹41,208 (2.21%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | 2 | Rejected-Finance Reject | |
| 3 | 3₹24.4 L+₹5.8 L (31.2%)Rejected-Finance H NO 89 BEHIND DD LEH UT LADAKH | LEH | LEH | LADAKH | 194101 | 3 | Rejected-Finance Reject | |
| 4 | 4₹24.9 L+₹6.3 L (33.8%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | 4 | Rejected-Finance Reject | |
| 5 | 5₹25.9 L+₹7.2 L (38.8%)Rejected-Finance | 5 | Rejected-Finance Reject |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
13 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (AF) Leh
GE (AF) Leh C/O 56 APO
REPAIR MAINTENANCE OF FCUs ACs SUMMER AND HEATING APPLIANCES AND CONNECTED WORKS AT AF STATION LEH UNDER GE (AF) LEH
2022_MES_517667_1
GE(AF)/LEH/T-08/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Leh
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Leh
₹52,000
Yes
27 May 2022
11 Apr 2022
16 May 2022
11 Apr 2022
13 May 2022
29 Apr 2022
60 days
Amount
Disconnecting, servicing and cleaning electrically operated FCUs of capacity 3000/ 4500 /6000 Kcal/hr from thermic fluid line complete and keeping aside for de-scaling/decarbonising , cleaning in all respect with suitable solution / solvent , checking all pipes leakage (inlet and outlet of FCUs) and brazing the punchered pipe where required, replacement of gate valve wherever required, cleaning of Y-strainer and reassembling and testing of the same complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of of Fan coil unit of cap 6000 KCal/Hr, PCB controlled with 3 Rows Deep copper coil in 3/8" construction including 12 mm thick pre - filter, DIDW Centrifugal blower with single phase direct driven motor including taking down old userviceable Fan coil unit complete all as specified and directed by Engineer-in-charge.
S&F in repairs of of Fan coil unit of cap 3000/4500 KCal/Hr, PCB controlled with 3 Rows Deep copper coil in 3/8" construction including 12 mm thick pre - filter, DIDW Centrifugal blower with single phase direct driven motor including taking down old userviceable Fan coil unit complete all as specified and directed by Engineer-in-Charge.
Taking out air space heater of capacity 60000 K Cal/Hr, disconnecting electrically, repair of air space heater by replacement of under mentioned spare parts and cleaning of burner chamber form inside, including servicing of burners of any make complete if required all as specified and directed by Engineer in charge. Note :i) Spares parts will be measured and paid under Sch Item No. 4.01 to 4.06 ii) Rate for labour and T&P required for supply only items are deemed to be included in above quoted rate.
Supply only Solenoid valve of suitable size, 220 V AC
Supply only nozzle as per existing
Supply only Fuel pump as per existing
Supply only fuel filter element as per existing
Supply only photo cell as per existing
Supply only sequence controller as per existing
Disconnecting, dismantling and taking out the non-functional Deep Freezers of any description, any make and in any position, capacity 310 Lts/320 ltrs/400 ltrs, including water connections, single phase, 50 Hz, strip opening, cleaning and servicing of the Deep Freezer with using suitable solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling Deep Freezer and testing of the Deep Freezer complete as all specified and directed by Engineer–in–charge. NOTE(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item (ii) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A' item 06 to 10. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item (iii) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line.
S & F in replacement for compressor of 310 / 400 ltr Deep freezer including necessary brazing work as required including re assembling and testing complete all specified and as directed by Engineer- in-Charge
S & F in replacement for thermal over load relay of 310 / 400 ltr deep freezer all specified and as directed by Engineer- in-Charge
S & F in replacement for Thermostate switch of 310 / 400 ltr deep freezer all specified and as directed by Engr- in-Charge
S & F in replacement for solenoid switch of 310 / 400 ltr deep freezer all specified and as directed by Engr- in-Charge
M & L for refilling of R-134a gas of 310 / 400 ltr deep freezer including necessary arrangement for gas filling.
Disconnecting, dismantling and taking out the non-functional Refrigerators of any description, any make and in any position, capacity 165 ltr to 320 ltr, single phase, 50 Hz, opening, cleaning and servicing of the refrigerator with using suitable solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling refrigerator and testing complete as all specified and directed by Engineer–in–charge. NOTE(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item (ii) Replacement of unserviceable / damaged body portions of the Refrigerator shall also be measured and paid for separately under appropriate item of Schedule `A' as supply only but fixing/assembling element of new / repaired body parts with existing parts is deemed to be included under this item . (iii) Burnt out windings and internal wiring, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding & supply only of internal wiring kit (iv) The rates for above items are deemed to include for transportation to & fro of Refrigerator to workshop as approved by Engineer-in-charge for necessary repairs and testing of Refrigerator at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one if required (v) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A' under item 11.01 to 11.07. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item
Supply only Vegetable tray suitable for 165 ltr to 320 Ltr cap refrigerator.
S & F in replacement of compressor for refrigerator of capacity 280/320 Ltrs including necessary brazing work as required including re assembling and complete all specified and as directed by Engineer- in-Charge
S & F in replacement of Thermostate switch for refrigerator of capacity 160/320 Ltrs complete all specified and as directed by Engineer- in-Charge
S & F in replacement of thermal overload relay for refrigerator of capacity 160/280/320 Ltrs complete all specified and as directed by Engineer- in-Charge
M & L for refilling of R12/ R-134a gas for refrigerator of capacity 165/320 Ltrs including necessary arrangement for gas filling complete all specified and as directed by Engineer- in-Charge.
S & F in replacement of compressor sealed unit for refrigerator of capacity 165ltr/210ltr including re assembling and testing complete all specified and as directed by Engineer- in-Charge
S & F in replacement of Capilary tube for refrigerator of capacity 165 / 210/280/320 ltr including re assembling and testing complete all specified and as directed by Engineer- in-Charge
Disconnecting electrical heat pillar of capacity 2KW/4KW and replacement of unserviceable spare parts and unserviceable burnt connection wires to make it fully serviceable and reassembling the same after repair and testingcomplete all specified and as directed by Engineer- in-Charge Note: Spare parts shall be measured for and paid separately under relevant items as in below 12.01 to 12.04, Cost of internal wiring shall be deemed to be included in quoted rates
Supply only heating rod of capacity 1KW / 2 KW
Supply only rotating fan with motor of suitable size
Supply only 2.5 Sqmm 2 core PVC cable copper conductor
Supply only Plug Top 15 A, 230V, AC
Taking down carefully Hot water dispensor of capacity 20 ltr of any make for carry out the repairs of unserviceable parts i.e bushes bearing, heating coil of capacity 1KW unserviceable burnt cable and other parts to make it fully serviceable and reassembling the same after repair and testing complete all as specified and directed by Engineer-in-Charge.
Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & strip opening of Voltage Stabilizer of 2 KVA/5 KVA single phase, air cooled, taking out unserviceable/defective wiring & parts, cleaning and servicing complete including replacement of unserviceable parts with new one and unserviceable wiring with new PVC insulated and unseathed stranded copper conductor cable of existing size, reassembling ,connecting and testing including cleaning the exposed surfaces of stabilizers complete all specified and as directed by Engineer- in-Charge Note:- Spares parts will be measured and paid under Sch Item No. (14.01) to (14.08)
Power transformer Input 140 – 280 volts & output 220 volts + 9% for 4/5 KVA Stabilizer
Power transformer Input 140 – 280 volts & output 220 volts + 9% for 2/3 KVA stabilizer
Relay 24 volts, single change over, 30 Amps.
Relay 18 volts, single change over, 10 Amps.
3 Core copper cable PVC insulated 1100 Volts of size 1.5 sqmm
Volt meter 0-300 Volts 50mm Square Elecetromechanical type.
Switch SPDT 220 Volts 1 Amp.
Indicator lamp ( Green/Red/Blue) - 220 Volts
Supply and fixing outer body of suitable size and gauge for the under mentioned capacity of stabilizers 02 KVA TO 05 KVA
Rewinding of voltage stablizer of capacity 2KVA to 5 KVA single phase with standard copper enamel wire and making connections (internal) including replacement of control card of voltage stabilizer PCB sensor, ICs and relays etc and testing the stablizer complete all as specified and directed by Engineer-in-Charge.
Supply and fix invertor Ac type Voltage Stablizer of Capacity 05 KVA
Supply and fix invertor Ac type Voltage Stablizer of Capacity 04 KVA
Supply and fix invertor Ac type Voltage Stablizer of Capacity 03 KVA
Servicing and repair of Heating Pads convection type of cap 1000x2 watts at different locations as specified and directed including replacement of spare parts. Note : i) Spares parts will be measured and paid under respective items of Sch 'A' item 20.01 to 20.03 ii) Rate for labour and T&P required for supply only items are deemed to be included in above quoted rate.
Supply only Thermostatically controlled switch as per existing
Supply only heating element of cap 1000W as per existing
Supply only Digital LED Display as per existing
Disconnecting, dismantling and taking out the functional Air conditioner window type of any description, any make and in any position, 1.5 TR capacity Capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, reassembling and testing of the AC complete all as specified and directed by Engineer–in–charge.
Disconnecting, dismantling and taking out the existing Air conditioner Split type AC 1.5/2/2.5 TR of any description any capacity, any make and in any position, both indoor and outdoor unit single/three phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed by Engineer-in-Charge. Note:-(i) The rates for above items are deemed to include for transportation to & fro of AC to workshop as approved by Engineer-in-charge for necessary servicing and replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one as required (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of schedule 'A' . (iii) Spare parts required to make AC serviceable will be paid separetly under Sch a Item from 22.01 to 22.15
Supply only compressor for 1.5 ton capacity AC unit as per existing type
Supply only compressor rotary type for 2 ton capacity AC unit as per existing type
Supply only PCB of inner unit of 1.5 / 2 Ton AC as per existing type
Supply only PCB of outdoor unit of 1.5 / 2 Ton AC as per existing type
Supply only condensing coil complete for 1.5 / 2 Ton AC as per existing type
Supply only cooling coil complete for 1.5 / 2 Ton AC as per existing type
Supply only filter flap for indoor unit complete set as per existing type
Supply only reverse cycle type valve for Hot & Cold mode for 1.5 / 2 Ton capacity AC
Supply only charging valve 1.5 Ton AC
Supply only charging valve 2.0 Ton AC
Supply only Outdoor unit fan motor 1.5/2.0 Ton AC
Supply only indoor unit blower with fan and bushes for 1.5 / 2Ton capacity AC.
Supply only starting capacitor 250 mfd + 10 mfd (combined unit).
Supply only refilling gas ( R-22/32A / R410) in 1.5 / 2 Ton AC.
Supply and fixing route pipe (copper tube) of size 3/8" or 5/8" dia complete with insulation.
Supply and fixing Heating element of capacity 4.0 KW (12") BSP flange 1.25" Hex Head 230 V 50 Hz AC suitable for Solar Water Heater of any Cap.
Taking down and dismantling of defective parts of geysers of any capacity by unscrewing the nuts from the mounting bolts and disconnection of electric and water connection including transportation the same to workshop and reinstallation/Reassembling complete of geysers after repair. NOTE(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ item 24.01 to 24.16 and fixing charges for new/ repaired items are deemed to be included under this item. (ii) Minor parts such as nuts and bolts reqd for fixing inner tank is deemed to be included under this item.
Supply only steel inner tank suitabel for geyser of capacity 25 Ltrs.
Supply only glass wool for Geysers of cap 25 Ltr
Supply only pressure release valve for geysers
Supply only dead weight valve for geysers
Supply only heating element 1.5/2.0 KW any type for Geysers.
Supply only thermostat of geysers
Supply only geyser assy 6/9 holes including, rubber rings, clamps, nuts & bolts etc for 25 Ltrs capacity geysers.
Supply only base plate of geysers of 25 Ltrs capacity.
Supply only PVC connection ½” heavy duty 450mm long for cold water.
Supply only PVC connection ½” heavy duty 450mm long for Hot water.
Steel water tubing, medium grade, Galvanized with screwed and socket joints, with all fittings such as short lengths, tees, bends, unions, elbows, reducers etc concealed in wall or laid fixed in repairs in floors 15mm bore size complete all specified and as directed by Engineer- in-Charge
Supply onlyf PVC cable 40/.0076 three core for geysers
Supply only indication lamp for Geysers
Supply only plug top 3 pin 15 Amp for Geysers
Supply only non return valve 15mm
Supply only single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb 10 amps.
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
Top Mind Industries Pvt Limited
M/S HIGHLAND ENGINEERING
national engineering
KONCHOK TSEWANG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .