Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹9.5 L
EMD Value
₹9,500
Closing Date
22 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer
Executive Engineer, PWD., Buildings (C and M) Division, Tirunelveli
Special repairs to UPVC Partition arrangements in Third floor Ortho Department in Tirunelveli Medical College Hospital at Tirunelveli District.
2026_PWD_711952_1
7(5) EE/2026-27 dated.06.10.2026
Open Tender
Civil Works - Buildings
Lump-sum
90 days
Tirunelveli medical college hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹9,500
8 Oct 2026
8 Oct 2026
23 Oct 2026
8 Oct 2026
22 Oct 2026
8 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls - Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs | 2.01 | M2 | 68.84 | ₹138.37 |
| 1.02 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls Brick / stone masonry in Cement mortar walls under 3m high | 3.42 | M3 | 318.11 | ₹1,087.94 |
| 2 | Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) | 1.25 | M2 | 1,590.26 | ₹1,987.83 |
| 3 | Dadooing walls with following best approved quality, Vitrified tiles 600 x 600 8mm conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) | 3 | M2 | 2,136.2 | ₹6,408.6 |
| 4 | Supply and installation of UPVC partitions with doors shall utilize UPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 74mm x 60mm x 56mm, a shutter of 104mm x 60mm x 66mm, a mullion of 72mm x 60mm x 36mm, a glazing bead of 35mm x 18mm, a 20mm multi-chambered hollow uPVC panel section of 150mm x 20mm, and a uPVC panel bead of 19mm x 16mm. All profiles of frames, sash, and mullion shall be reinforced, where required, with 1mm thick GI steel sections. The door will be equipped with 3D hinges for enhanced weight holding capacity, and security devices such as multipoint lock systems with a cylinder lock facilitated handle, all compliant with relevant specifications and departmental directives. Glazing or uPVC panels shall be 5mm thick Plain Toughened or uPVC panel grip, held by TPE (Grey) weather-sealed gaskets. All corners and mullion joints of the frame and sash shall be mitred cut and fusion welded without mechanical joints, with all welded joints neatly trimmed to a grooved nib finish, ensuring the finished products are free from sharp edges. The complete units shall be fixed into pre-finished openings by drilling and fastening through the outer frame using high-quality fasteners, and silicon sealant shall be applied to fill the gap between the wall and the frame for a leak- proof installation and completion etc., Complete and as directed by the department officers. | 77 | M2 | 9,500 | ₹7,31,500 |
| 5 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections.
Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.
Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.
Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam.
Installation: The profiles should be cut to length and welded 45 degrees. The window should be desinged such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. | 3.3 | M2 | 8,313 | ₹27,432.9 |
| 6 | Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work. | 1.6 | M2 | 5,047 | ₹8,075.2 |
| 7 | Supply and installation of Acoustical False Ceiling of Higher absorption nubby finish tiles, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595
× 15mm having volume density 120 Kgs / m3, weight 1.8 / 2.4 / 3 kg / m2 which is suspended by using 0.3mm thick T15 metal grid system. T15 metal grid system of 600 × 600mm module includes WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspenc the MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally, the CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600 × 600mm module. The Higher absorption Nubby finish tiles square edge of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department officers. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc. complying to standard specication. | 16.3 | M2 | 1,734 | ₹28,264.2 |
| 8 | GST | 1 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.18 MB
Tendercondition5.pdf
Tender Documents • 0.97 MB
BOQ_855295.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .