Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC ASHAA BHAVAN RAMNAGAR NAKA FAIZABAD | AYODHYA | UTTAR PRADESH | 224001 | L1 | Accepted-AOC The lowest tenderer | |
| 2 | L2₹39.1 L+₹1.2 L (3.29%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹39.6 L+₹1.8 L (4.73%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹41.5 L+₹3.6 L (9.56%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹41.5 L+₹3.6 L (9.63%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹80,580
Closing Date
13 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
PROVN OF SINGLE JCOs ACCN FOR KLP I AT FAZILKA MIL STN UNDER GE ABOHAR
2024_MES_642281_1
CA NO CWE SGNR T-67 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE ABOHAR
As per NIT
9 documents required · 9 mandatory
₹500
GE ABOHAR
₹80,580
10 Apr 2024
14 Feb 2024
15 Mar 2024
14 Feb 2024
13 Mar 2024
28 Feb 2024
Amount
Surface excavation in soft/ loose soil n.exc 30cm deep & averaging 15cm deep and getting out complete all as specified & directed by Engr-in-charge.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified & directed by Engr-in-charge.
Excavation in trenches n.exc. 1.50m wide and n.exc 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc. 10 Sqm on plan and n.exc 1.5 m in depth and getting out in getting out in soft / loose soil complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No 3.00 above but depth exc 1.5m and not exc 3 meter depth complete all as specified and as directed by Engineer-in-Charge.
Excavation in post holes each n. exc. 0.50Cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8), type D2, using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in foundation of cols, boundary pillars, posts, struts, etc. filling and mass concrete complete all as specified and shown on drawing.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge.
M&L for formwork to sides of pillars, columns etc; rough finish surface of concrete square, rectangular or polygonal complete all as specified and as directed by Engineer-in-Charge.
M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, etc. also splays between floors and beams, etc. rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge.
M&L for formwork to chajjas, troughts and similar items including edges rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge.
M&L for fromwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide, rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No 14.00 above but 5mm dia and over upto and including 10mm dia as in stirrups, spaces & binders complete all as specified and as directed by Engineer-in-Charge.
M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, pillers etc complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately under respective item of BOQ.
M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in columns, pillars complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately undr respective item of BOQ.
M&L for reinforced cement concrete (design mix) M-25, using 20mm graded stone aggregrate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately undr respective item of BOQ.
M&L for reinforced cement concrete (design mix) M-25, using 20mm graded stone aggregrate in Chajjas; complete all as specified and as directed by Engineer-in-Charge.. Note : Reinforcement shall be measured and paid seperately under respectively item of BoQ.
M&L for reinforced cement concrete (design mix) M-25, using 20mm graded stone aggregrate in slabs supported on walls, beams and columns in floors, roofs, Stair case, landings, balconies, canopies, deck slabs and in shelves and the like; complete all as specified and as directed by Engineer-in-Charge.. Note : Reinforcement shall be measured and paid seperately under respective item of BoQ.
M & L brick work with sub class 'B' burnt clay bricks, straight or curved on plan exc 6m mean radious built in CM 1:6 complete all as specified and directed.
M&L for brick work with fly ash bricks, of old size bricks, straight or curved exc. 6 m mean radius built in CM (1:6) complete all as specified and as directed by Engineer-in-Charge.
M&L brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, buit in CM (1:4) complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm all in soil complete all as specified and as directed by Engineer-in-Charge.
M & L brick work with sub class 'B' burnt clay bricks, straight or curved on plan exc 6m mean radious built in CM 1:4 complete all as specified and directed.
Spreading and levelling in layers n.exc 25cm thick and well ramming including watering as required under floors; all as directed. (in floor with available earth from excavation as approved by Engr-in-Charge.
Removing excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface. Note : Area of the sub structure in contact with backfill to be measured.
M&L for treating the top surface of filled earth @ 5 litres emulsion per square metre of surface complete all as specified and as directed by Engineer-in-Charge.
M&L for treating the soil under plinth protection @5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engineer-in-Charge.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified.
M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface in broken stone or boulders (15cm compacted thickness) complete all as specified and as directed by Engineer-in-Charge.
M&L for 75 mm thick PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed by Engineer-in-Charge.
M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors complete all as specified and as directed by Engineer-in-Charge.
M & L for 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) in flooring complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4), type B-0, using 12.5 mm graded stone aggregate as in floor or laid under floor etc complete all as specified and as directed by Engineer-in-Charge.
M&L for joint free Non-skid Ceramic coloured tiles 7 to 8 mm thick, area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. over and including 15 mm thick screed bedding in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and as directed by Engineer-in-Charge.
M&L for joint free glazed Ceramic coloured tiles of size 450 x 300 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and as directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and as directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 10 mm thick rendering on vertical surface in cement mortar (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed by Engineer-in-Charge.
M&L for machine cut Kota stone slab flooring 20-25mm thick (size 550 x 550 mm) over and including 15mm thick screed bed in CM (1:6) laid and and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engineer-in-Charge.
M & L Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick rendering in cement mortar (1:4), complete all as specified and as directed by Engineer-in-Charge.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding to edges of stone slabs (one edge) complete all as specified and as directed by Engineer-in-Charge.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing. Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
S&F 18mm thick PVC sheet having one side decorative laminated sheet all required brackets SS screws etc. the panel shall be fabricated using adhesive and screws where ever required all the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per make and specification as directed by Engineer -in-Charge.
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flaps of 30 mm fix with wooden/ plywood and complete all as specified and as directed by Engineer-in-Charge.
S&F 100 mm size hasp and staple,safety type, stainless steel bright finish including bolt to hinge plate and fixed with screws,complete all as directed.
S & F for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering, 10 mm thick on brick work or concrete surfaces in cement mortar (1:6) on wall finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge..
M&L for 5 mm thick rendering in cement mortar (1:4) (as second coat), over and including 10 mm thick rendering in cement mortar (1:6) (as first coat) of fair faces of brick work or concrete surfaces of wall, incl mixing only liquid water proofing compound in second layer only as per manufactures instruction, finished the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note :- WPC Shall be measured and paid separately as supply only.
M&L for rendering, 5 mm thick on brick work or concrete surfaces in cement mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge..
M & L 15mm thick rendering on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement all as specified .
Supply only liquid water proofing compound all as specified and directed by Engr-in-Charge.
M&L for preparation and applying three coats of white wash on newly plastered surfaces of wall complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation and applying three coats of white wash on newly plastered surfaces of ceiling complete all as sepecified and directed by Engineer-in-Charge.
M&L for two coats of acrylic distemper on new plastered surfaces of walls over 3mm thick wall care putty over a coat of primer including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge..
M&L for preparation and applying two coats of cement base paint on newly plastered surfaces of wall complete all as specified and as directed by Engineer-in-Charge..
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete complete all as specified and as directed by Engineer-in-Charge. Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site requirement and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having facilities for testing of membrane.
S&F for factory made window, made out of MS hollow section of size 79mm x 39mm x 1.6mm thick frame with double shutter (glazed and wire guage shutter) made out of Z section using flush butt welding and tenon riveting all as per IS 1038/83, dobby hinges shall be provided to both shutter, locking arrangement as per sample approved by GE, provided with knob 'Z' section handles 100mm size and 150 mm long hook and eye welded to frame and shutter,four number legs welded to frame including necessary flat iron beading for securing wire gauge etc including holes, cutting holes for hold fast and making good disturbed surfaces in PCC (1:2:4) type B1 to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge.
S&F for factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, steel peg stay, complete all as specified & directed by Engineer-in- charge.
M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spiles; framed guard bars; barred iron doors; ladders; framed balusteres; walk ways, railings; framework of water tanks and similar work confirming to Fe. 290, Gde-E-165 with complete all as specified and as directed by Engineer-in-Charge..
M&L for framed work as in chowkats of doors windows of angle iron ,gates or other section with gusset plates, rails, braces etc conforming to Gde Fe. 290, Gde-E-165 complete complete all as specified and as directed by Engineer-in-Charge.
S&F for 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer-in-Charge..
S&F for 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed by Engineer-in-Charge..
Supply and fixing of Fibre glass Reinforced plastic (FRP) door frame of required built in colour in three legged of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick including laminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood in all three legs frame shall be covered with fibreglass from all sides MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specified and as directed by Engineer-in- charge.
Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled door shutter conferming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge.
S&F for 100 mm long butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anosied and fixed type B-21 complete all as specified and as directed by Engineer-in-Charge..
Supply & fixing 100mm long butt hinges mild steel medium weight cold rolled including necessary welding etc. to steel frame complete all as specified and as directed by Engineer-in-Charge..
S&F for 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed by Engineer-in-Charge..
S&F for 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified and as directed by Engineer-in-Charge..
S&F for 150 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and as directed by Engineer-in-Charge..
S&F for 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and as directed by Engineer-in-Charge..
S&F for 2nd class hard wood (Sal) or any other 2nd class hard wood articles not exceeding 200 cubic centimetre each as small fittings such as shaped door and window stops and the like, including necessary labour etc complete all as specified and as directed by Engineer-in-Charge..
S&F for stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-Charge.
S&F for 4 mm thick sheet glass ordinary quality and glazing with spring clips in metal surrounds and oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and as directed by Engineer-in-Charge.
S&F for 4 mm thick figured glass, pin head type and glazing with spring clips in metal surrounds and oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed by Engineer-in-Charge.
S&F drapery rods stainless steel finish, standrad quality, 25mm dia with heads at both ends, rings, etc complete all as specified and as directed by Engineer-in-Charge.
S&F vitrieous china wash down WC (Pedestal pattern) white and flush piple including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc, complete all as specified and as directed by Engineer-in-Charge.
S&F plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, Jet spray , seat and cover for water closet (European type) complete all as specified and as directed by Engineer-in-Charge.
S&F vitreous china wash hand basin coloured Flat back of size 550x400mm, long screwed shank fly nut flange end including cutting for and pinning in ends of brackets in (1:3) CM including 32mm dia chromium plated waste coupling/trap complete all as specified and as directed by Engineer-in-Charge.
S&F 10 litres capacity PVC valve less syphonic action type low level flushing cistern white with inlet incl flush pipe of low or high density of PVC 32mm dia, 90cm long and 15mm stop cock making connection incl ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and as directed by Engineer-in-Charge. by Engr-in-Charge.
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed by Engineer-in-Charge..
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by Engineer-in-Charge..
S&F brass hat pegs, solid body, 125 mm to 175 mm (5 legs) complete all as specified and as directed by Engineer-in-Charge..
S&F rotational moulded polythene water storage tank 500 ltr capacity of tripple layer vertical with closed top (ISI Marked) hoisted and fixed in position all as specified in SSR part-I. complete all as specified and as directed by Engineer-in-Charge..
S&F 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing 100 mm bore cast iron spun cast pipe Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engr-in-charge.
Supply & fixing 75 mm bore cast iron spun cast pipe Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engr-in-charge.
S&F 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by Engineer-in-Charge.
S&F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by Engineer-in-Charge.
S&F CI vent cowl of dia 100mm complete all as specified and as directed by Engineer-in-Charge..
S&F 75 mm bore cast iron bends with oval access doors (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by Engineer-in-Charge.
S&F 100mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches door fixed with necessary coupling complete all as specified and as directed by Engineer-in-Charge.
S&F 75mm dia + outlet, cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed by Engineer-in-Charge.
S&F Structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes grade St-240 complete all as specified and as shown on drawing.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S & F glass dividing strips, 3mm thick, 38mm width and inserted in position to conform to design all as specified and directed by Engineer-in-Charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia stop valve, fany type chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and as directed by Engineer-in-Charge.
S&F 15 mm dia stop valve/angle valve, fancy type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and as directed by Engineer-in-Charge..
Supply and fix pillar taps of swan neck type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in 15mm dia bore pipe complete all as specified and as directed by Engineer-in-Charge..
Supply and fix bib taps, cast copper alloy fancy type chormium plated. with crutch or butterfly handle screwed down screwed for iron pipe of brass ferrule, and fixed in 15 mm bore dia of pipe complete all as specified and as directed by Engineer-in-Charge.
S&F chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-Charge..
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed by Engineer-in-Charge..
S&F 25 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed including of all fitting complete all as specified & directed by Engr-in-Charge.
S&F 20mm dia gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by Engineer-in-Charge..
S&F 15 mm bore Galvanised iron tube medium grade with all fitting fixed concealed complete to walls and ceiling or laid in floors, complete all as specified and as directed by Engineer-in-Charge..
S&F 20 mm bore Galvanised iron tube medium grade with all fitting fixed concealed complete to walls and ceiling or laid in floors, brenches complete all as specified and as directed by Engineer-in-Charge..
S&F 25 mm bore Galvanised iron tube medium grade with all fitting fixed concealed complete to walls and ceiling or laid in floors complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing GI pipe galvanised iron tube " Medium class " with all fitting laid in trenches of size 50 mm dia bore complete all as specified and directed by Engineer-in-Charge.
M &L for cutting existing Steel tubing upto 100mm dia laid in trenches of any size for addition and alternation complete all as specified and directed.
M&L Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector complete all as specified and directed.
S&F cast iron fittings for bends, tapers, tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged upto 150 mm bore complete all as specified and directed by Engr-in-Charge.
S & F stop valve size 50 mm cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
S & F stop valve size 20 mm cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for broken stone or boulders in hardcore of gauge exc 63mm but n.exc 100mm deposited spread and lavelling in layers n.exc 15cm thick watered and rolled/ rammed to a true surface comple all as specified and directed by Engineer-in-Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete pave block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drived ways or light traffice packing etc, of required strength, thickness & size/ shape made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrate, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L Cement concrete 1:2:4, type B1, (20 mm graded stone aggregate) in surface channels and drains complete all as specified and directed.
M&L for cement concrete 1:3:6, type C1, using 20 mm graded stone aggregate as in benching, coping etc. complete all as specified & directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc.
M&L for DWCPE pipe 150 mm dia (160 mm OD) complete laid in trenches including earthwork, removal and returning filling and jointed including testing alongwith necessary jointing material tees/union/socket etc complete laid on PCC bed 150 mm thick PCC in 1:3:6 type C2 of avg depth 0.45 m to 1.65 m depth including packing under and haunching against the side of pipes after they are laid and tested all as specified in IS 16098:2013 and as directed.
M&L for Providing precast cement concrete set in cement concrete 1:2:4 type B1 (20mm graded aggregate) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces
Cutting into existing manholes for connecting new drains of 150mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required
M&L for PCC 1:2:4, type B-2, using 40mm graded stone aggregate as in foundation, filling mass concrete and bed of drains complete all as specified.
M & L for point wiring complete with 1.5 Sqmm (Nominal area) PVC insulated multustranded fire retardant (low smoke unsheathed and multicore copper conductor cable with colour code ISI marked and including 20mm dia PVC concealed conduit ISI marked and conduit fittings for one light point/fan point/exhaust fan/Bell Point controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified (Cost of MS sunken box and bakelite sheet included in the rate).
All as per Ser item No 128.00 above but one three pin socket outlet 5 Amps on the independent board complete all as specified.
All as per Ser item No 128.00 above but one three pin socket outlet 5 Amps on the same board complete all as specified.
All as per Ser item No 128.00 above but with 1.5 Sqmm (nominal area) PVC insulated multistranded copper conductor cable unsheathed ISI marked controlled by two way switches complete all as specified.
M&L for point wiring complete with 2.5 Sqmm (Nominal area) PVC insulated multistranded fire retardant low smoke unsheated and stranded copper conductor cable ISI marked in and including 20mm dia PVC concealed conduit medium quality and conduit fitting for 3 pin 15 amp multicore switch socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified.
S&F switch Piano type single pole one way 5 Amp,230 VAC complete all as specified and directed by Engineer-in-Charge.
S&F switch Piano type single pole two way 5 Amp,230 VAC complete all as specified and directed by Engineer-in-Charge.
S&F socket two in one ,3 Pin 5 Amps 230 VAC complete all as specified and directed by Engineer-in-Charge.
S&F switch Piano type single pole one way 15 Amp on laminated sheet top cover complete all as specified and directed by Engineer-in-Charge.
S&F socket Pinao type 6 Pin, 16 amp, 230 VAC.
Supply & fixing PVC Lamp holder suitable for and including batten fittings ,LED Electric lamp 9 Watt with backalite 20mm back plate complete all as specified & directed, .
M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed.
S&F Electric bell, ding dong, AC, 230 volts, single phase complete all as specofieed and directed.
S&F bell push, flush type, 5 Amp, complete all as specified and directed.
S&F of fan regulator step down electronic type heavy duly flush type 230 volts AC single phase fixed on laminated sheet top cover (laminated top cover is included in point wiring) and connecting up complete all as specified and directed. (Laminated sheet top cover and sunken box is included in point wiring).
Supply and fixing complete set of 1x10 watt LED retrofit type bulkhead fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge.
S & F of MCB suitable for 240 volts, AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed.
S & F of MCB suitable for 240 volts, AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 40 Amps all as specified and directed.
S & F of MCB suitable for 240 volts, AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 32 Amps all as specified and directed.
S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed..
S&F and testing LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin.
M & L for Sub main wiring with 2 single core 6 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn into and including 20mm dia PVC conduit rigid non metallic with and including independent PVC insulated one run 6 Sqmm single core copper earth wire complete all as specified. Note:- Three lengths of 6 sqmm cable and one run of conduit will be measured as one length.
S & F LED street light luminaries 30 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engineer-In-charge.
Supplying, fixing,testing,& commissioning intergal decorative Water proof 9 Watt LED bollard light with opal acrylic with IP-65 protection with inbuilt driver, colour temperature of 5700 K of graphite grey powder coated finish type complete all as specified and directed by Engr-in-Charge.
S&F single door SPN DB 2 way having facility to fix MCB DP/SPN 2 ways complete fitted with bus bars, neutral links including provision of MCB DP 6-16A and making good disturbed surface area complete all as specified and directed.
Supply and fixing single phase electronic meter tamper proof LCD Display with poly carbonate cover 230 V, 10-60 Amp accuracy class-I, 50 Hz, conforming to IS 13779, IP-54 with parameters to show data, time, current reading , load, PF, Voltage and KWH including taking down old meter complete all as specified and as directed by Engineer-in-charge.
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing electric water heater (Geyser) storage type ABS body of capacity 25 Ltrs, 5 Star rating, 230V, single phase AC supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with Hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece, PVC connection for hot and cold water, three core PVC Insulated PVC Sheathed copper conductor flexible cable including 15Amp plug suitable for existing socket and fixing material, 04 No Nut bolts etc. Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge.
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge.
Material and labour for sand cushioning, with dry and clean fine river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- Punned thickness shall be considered for payment purpose.
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.
Boring hole/Excavation by trenchless technology for boring of holes under road, pavement, hardstanding using trenchless boring machine or by means of manual manpower suitable for inserting GI pipe any dia upto 50mm including removal of surplus soil and making good disturbed surface complete all as specified and as directed. Note:- Pipe for inserting as required shall be measured and paid for separately.
Supply and fixing GI tubing light grade of size 50 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under road for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Schedule.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCB incomer upto 100 Amps and MCB in outgoing , TPN 4 Way Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar,neutral links, door earthing , IP-43 Protection including making good disturbed surfaces complete all as specified and directed.
S&F MCCB TPN(4 Pole), 63 Amps 415 Volts of breaking capacity 36 KA (Adustable thermal and adjustable magnetic release setting) complete all as specified and directed.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.
RUCHIKA CONSTRUCTIONS
MANCHANDA CONSTRUCTION CO
N.R.Builders
P.K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .