Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC VILL P O NARIT P S AMTA DIST HOWRAH PIN 711413 | HOWRAH | WEST BENGAL | 711413 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹4.6 L+₹8,362 (1.83%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹4.7 L+₹17,520 (3.84%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest bidder |
Tender Value
₹4.6 L
EMD Value
₹9,136
Closing Date
13 Dec 2024, 12:00 pmClosed
EE_I, Kol. South Health El. Divn.,P.W.Dte.
75 D H Road Kidderpore Kol_23
Modification and expansion of existing CCTV Room and creation of new rest room for OC Outpost with necessary electrical and air conditioning work in Ground Floor of Emergency Building at IPGMER-SSKM Hospital,Kolkata
2024_WBPWD_770946_1
WBPWD/EE-I/KSHED/Q81/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,136
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
4 Apr 2025
19 Nov 2024
16 Dec 2024
19 Nov 2024
13 Dec 2024
26 Nov 2024
25 Nov 2024
Amount
Dismantle charges for exisiting air ventilation duct and electrical wiringand DB in main emergency waiting area with help of necessary tools & tackles , necessary man power and safety measure ,without hampering patient care service.
Installation testing & commissioning of above AC machines by 4 nos ms structure of minimum 200 mm long MS equal angle of sizes 40mX40mmX 5 mm (with 2 nos 10 mm hole) and 100 mm long MS equal angle of sizes 40mX40mmX 5 mm (with 1 no 10 mm hole in centre position) lap welded each other and creating a zigzag structure . This 4 nos of MS structure fixing in ceiling by 2 nos fasteners .The indoor unit suspended from this angle support with 4 nos 8 mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on Pre fabricated MS structure.
Installation testing & commissioning of above AC machines fixing the indoor unit suspended from ceiling with 4 nos 8 mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on prefricated MS Structure.
Supply & Laying of Refrigerant Copper pipe of following diameter for connecting of Indoor to Outdoor unit, along with drip resistant nitrile rubber insulation with double insulating wrapping tape to avoid dripping of condensate water:-
Copper pipe 9.5mm dia, min. thickness 0.8mm (Make : Rajco / Mandev) with 9mm thick nitrile insulation with necessary rapping tape.( Accoflex/K-flex/Armasell)
Copper pipe 15.88mm dia, min. thickness 0.99mm (Make : Rajco / Mandev) with 9mm thick nitrile insulation with necessary rapping tape.( Accoflex/K-flex/Armasell). [
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 4 Core 2.5sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement.
Supply & laying drain Water piping work with 25 mm dia Schedule 40 PVC/ UPVC hard pipes (Ashirbad / Supreme/Prayag ) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc.
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m(Including Necessary Fabricated MS structure,Red oxide, enamel Painting, Brick Wall cutting ,Grouting and Masionary work for making AC outdoor unit platfrom)
Box type scaffolding charges for structureal works and shifting the 2 nos outdoor unit upto height of 25 ft above with necessary safety arrangement and without hampering patient care service.
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire(Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.
Average run 9 mtr
Do….. On Board
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply of Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 502P 1xT-LED22W P3241/Wipro having similar specification). incl S&D 1x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat. No. - Mas LED tube 1200 mm 18W/2100lm 865T8I) having similar specification including aluminium heat sink strip).
Supply of Double industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 502P 1xT-LED22W P3241/Wipro having similar specification). incl S&D 2x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat. No. - Mas LED tube 1200 mm 18W/2100lm 865T8I) having similar specification including aluminium heat sink strip).
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
S & D 48″ sweep, 230V 1-Ph. AC ceiling fans incl. all accss. .5 star ,Rating: 40 watt ( Maximum) (Make - CG HS Dura/ Equivalent )
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing 240 V, 3 nos. 20A plug socket with separate 3 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 2 Nos 6A, plug socket with separate 2 nos 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. ( Siemens/Legrand/Schneider)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection ( Make : Legrand/Siemens/Schneider)
ii)25 A DP
iii)63 A DP
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
i)2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
iii)2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe/PVC rigid conduit pipe and by the prelaid GI fish wire and making necy. connection as required
4x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC
2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supply & Fixing 240 V, 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
S&F of 250V, 25A timer controlled starter for . room Air Conditioning machine in SS double door 14-way DB enclosure (L&T/ ABB/ Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 & 1 x 2.5 mm² copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall icl necessary connections as per direction of EIC:-
i) 25A DP MCB (L&T/ ABB/ Legrand make) -- 1no ii) 24Hr x 7days programmable Digital timer (L&T make Cat no 67DDT0 or equivalent) -- 1no iii) 3-pole power contactor Rating -22A (Schneider EasyPact TVS Control Relay CAE22 or equivalent) -- 1 no. iv) 2-Modular AC motor starter (Legrand/Myrius Cat no 673031) -- 1 no. v) 1-module 10A Modular switch (Make Legrand /Myrius) -- 1 no vi) 3-module plate with cover (Make Legrand /Myrius) -- 1no vii) 25A Auto-Off-Bipass SPDT toggle switch (appvd reputed make) - 1 no. viii) LED indication lamp (approved reputed make) -- 1 No. ix) Outgoing bakelite connector 32A (Reputed make as approved by EIC) - 3 nos.
S&F of 415 V, 25A dual timer controlled room Air Conditioning machine in SS double door 16-way DB enclosure (L&T/ ABB/ Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 4 x 4 & 1 x 2.5 mm² copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall icl necessary connections as per direction of EIC:-
i) 16A 3P MCB (L&T/ ABB/ Legrand make) -- 1no ii) 6A SP MCB (L&T/ ABB/ Legrand make) -- 1no iii) 24Hr x 7days programmable Digital timer (L&T make Cat no 67DDT0 or equivalent) -- 1no iv) 3-pole power contactor Rating 22-25 A [Schneider EasyPact TVS Control Relay CAE22] -- 2 nos . v) LED indication lamp (approved reputed make) -- 2 Nos. vi) Outgoing bakelite connector 32A (Reputed make as approved by EIC) - 10 nos.
Supply ,delivery , installtion and commissioing of Automated Modular Fire Suppression System (ABC MAP90 Powder Based) - 5Kg Make: Ceasefire /Fire shield (Ceiling Suspended Type)
Supply ,delivery , installtion and commissioing of Air Curtain minimum lenght of 4 ft ,Air Velocity Minimum 15 m/Sec.Horizontal Mounting position ,No of Impeller :2 ,Power Supply :230 A AC( Make: Airotek or quivalent )
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
MONDAL ELECTRICAL ASSOCIATES (BID ID -5845167)
MONDAL ELECTRIC CO. (BID ID -5844759)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .