| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹21.0 L Quoted ₹21.6 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹22.2 L+₹56,496 (2.62%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | ₹22.2 L+₹56,496 (2.62%) | L2 | Rejected-Finance Higher |
| 3 | L3₹22.9 L+₹1.3 L (5.95%)Rejected-Finance | ₹22.9 L+₹1.3 L (5.95%) | L3 | Rejected-Finance Higher |
| 4 | L4₹27.4 L+₹5.8 L (26.8%)Rejected-Finance | ₹27.4 L+₹5.8 L (26.8%) | L4 | Rejected-Finance Higher |
| 5 | L5₹27.5 L+₹5.9 L (27.1%)Rejected-Finance | ₹27.5 L+₹5.9 L (27.1%) | L5 | Rejected-Finance Higher |
Tender Value
₹24.9 L
EMD Value
₹49,800
Closing Date
3 Dec 2018, 6:00 pmClosed
GE (AF) Amla
GE (AF) Amla Amla Depot Dist Betul (MP) 460553
Repair/ Maintenance of UG Cable and Connected works at domestic area at 28 ED AFS Amla
2018_MES_222295_1
8298/06/E8 of 2018-19
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Amla
Class E
Category b (i)
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹49,800
Yes
31 Mar 2020
3 Nov 2018
4 Dec 2018
3 Nov 2018
3 Dec 2018
17 Nov 2018
Amount
Taking out carefully PVC insulated sheathed armoured stranded aluminium conductor LT underground cable from trenches/ ducts/ walls etc., including necessary dismantling, demolition and disconnecting cables from existing power line complete all as specified and as directed for the following sizes of cable:- Note :- (i) Earth work excavation, returning filling and disposal shall be measured & paid separately under respective items. (ii) The surface disturbed during dismantling/demolition shall be made good by contractor at his own cost by using 1:2:4 type B1 concrete (or) in CM 1:4 which deemed to be included in the contractor quoted rate.
2 core 10 to 16 Sq. mm
3.5 core 25 to 70 Sq. mm
3.5 core 95 to 240 Sq. mm
4 core 10 to 16 Sq. mm
4 core 25 Sq. mm
Laying only PVC insulated, sheathed, armoured heavy duty electric UG cable with multistranded aluminium conductor LT 1100 Volts grade laid in trenches/passing through pipe/duct or fixed to wall, panel etc., and connecting up including testing complete all as directed for following size of cables:- Note :- (i) Serviceable cables obtained from Item No 1.01 to 1.05 shall be re-used/ LT UG cables issued by MES under Schedule "B" shall be used.
2 core 10 to 16 Sq. mm
3.5/4 core 25 to 70 Sq. mm
3.5 core 95 to 240 Sq. mm
Supply lay & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for the following size of cable:-
2 core 10 Sq. mm
3.5 core 50 Sq. mm
3.5 core 95 Sq. mm
3.5 core 120 Sq. mm
4 core 10 Sq. mm
4 core 16 Sq. mm
4 core 25 Sq. mm Notes for Item No 2.01 to 3.07:- (i) The minor parts such as clamps, screw etc.,, required for fixing cables on wall, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate. (ii) Earth work excavation, returning filling and disposal, protection pipe, joint kit, HDPE pipe shall be measured & paid separately under respective items.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
Returning filling in excavated soil including spreading levelling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Supply and spread dry river washed sand free from foreign material in trenches for cable cushioning all as specified and directed. Note:- For payment purpose only punned thickness of sand will be measured & paid.
Supply and laying un-reinforced precast concrete cable covers of class LV type-1, flat size 250 x 150 x 40 mm all as specified and as directed.
Material and labour for Galvanised steel tubing, light grade laid in trenches/ fixed to poles, walls etc as a protection for service cable including removing existing old unserviceable rusted pipe complete all as specified and directed for the following size of pipe:- Make:- Tata / Jindal / Prakash Surya
15mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
100mm dia bore Notes for Item No 9.01 to 9.05:- (i) The minor parts such as clamps, screw etc.,, required for fixing pipe on wall, pole, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate.
Dismantling of old non reusable concrete poles of any size and disposing them away from defence land complete all as specified and directed.
Supply & fix LT cable Mild steel Route marker as per sample shown by Engg-in-charge all as specified and as directed. Note :- Earth work & PCC work shall be measured and paid separately
M&L for providing horizontal bore hole of dia upto 150mm below road/hard standing surface for the length upto 12 Metre and inserting GI/PVC pipe into the bore hole as cable protection complete all as specified and as directed. Note:- Cable protection pipe shall be measured and paid separately under relevant item.
Taking out old U/S LT feeder pillar and Supply , Installing/ connecting & testing of LT feeder pillar box out door type, CPRI approved, weather and vermin proof, factory fabricated, epoxy powder coated paint , cubical type, made out of CRCA sheet 03 mm thick with mounting on frame of angle iron 50 X 50 X 5 mm fixed on ground but not less than height 30 Cm from ground level suitable for 415 volt, 3 phase, 4 wire system with front double door and rear single door with both side sliding tower bolts for locking arrangement including internal wiring with suitable size of copper standard wire complete all as specified, comprising by providing of the following equipment’s /fitments complete all as specified and as directed:- (a) Aluminium bus bar suitable for three phase of rating 500 Amps and neutral of rating 250 Amp covered with coloured PVC sleeves as per colour code mounted on DMC insulators - 01 Set (b) MCCB 315 Amp , 415 Volts, 4 pole , Breaking capacity 36 KA with thermal magnetic release - 01 No (c) MCCB 160 Amp , 415 Volts, 4 pole, Breaking capacity 25 KA with thermal magnetic release - 02 No (d) MCCB 125 Amp , 415 Volts, 4 pole, Breaking capacity 16 KA with thermal magnetic release - 01 No (e) Digital VAF+PF meter with suitable CT's complete - 01 Set (f) Indicator lamp (RYB) - 01 Set Make:- (i) MCCB : L&T / Legrand / C&S (ii) Panel : Maklayer / Expert Engineers/ Universal Switchgear Pvt Ltd. or equivalent make as approved by GE
Taking out old U/S LT feeder pillar and Supply, Installing, connecting & testing of LT feeder pillar box out door type, CPRI approved, weather and vermin proof, factory fabricated, epoxy powder coated paint, cubical type, made out of CRCA sheet 03 mm thick with mounting on frame of angle iron 50 X 50 X 5 mm fixed on ground but not less than height 30 Cm from ground level suitable for 415 volt, 3 phase, 4 wire system with front double door and rear single door with both side sliding tower bolts for locking arrangement including internal wiring with suitable size of copper standard wire complete all as specified, comprising by providing of the following equipment’s /fitments complete:- (a) Aluminium bus bar suitable for three phase of rating 200 Amps and neutral of rating 100 Amp covered with coloured PVC sleeves as per colour code mounted on DMC insulators - 01 Set (b) MCCB 125 A , 415 Volts , 4 pole, Breaking capacity 16 KA with thermal magnetic release . - 01 No (c) MCB 100 A , 415 Volts, 4 pole, Breaking capacity 16 KA with thermal magnetic release . - 02 No's (d) Digital VAF meter with suitable CT's complete - 01 Set (e) Indicator lamp (RYB) - 01 Set Make:- (i) MCCB : L&T / Legrand / C&S (ii) Panel : Maklayer / Expert Engineers/ Universal Switchgear Pvt Ltd. or equivalent make as approved by GE
Supply and erect steel tubular swaged poles type 410 SP-22 & 8.5 metre long conforming to IS complete with cast iron base plate, final taper plug, bolts, nuts and screws including painting with two coats of aluminium paint over a coat of primer above GL and black bituminous paint for portion below GL (inside and outside) complete all as specified and as directed. Note:- Earth work and PCC will be measured and paid separately under relevant items.
Material and labour for plain cement concrete 1: 4: 8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
Material and labour for plain cement concrete 1: 3: 6 type C2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
Material and labour for plain cement concrete 1 : 2 : 4 type B1 using 20 mm graded stone aggregate as in coping and the like including necessary form work etc, complete all as specified & directed.
Material and Labour for rendering of 15 mm thick in CM 1:6 on vertical fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 25 x 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipment’s etc at the other end including 32 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified & directed. Note :- (i) Earthing resistance required in earthing shall less than 2.0 Ohms after completion of work. All earthing shall be tested by the contractor in presence of Engr-in-Charge. Test result shall be recorded and signed by the contractor and Engr – in- Charge. If contractor fail to achieve the above result the same shall be rectified by the contractor without any extra cost to Govt. The earthing result will be required maintaining up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engg-in-Charge and contractor shall rectify the same. The quoted rates shall be deemed to include for above said provision. (ii) Quoted rates shall be deemed to be included for earth strip with protection pipe up to 7.5 length.
M&L for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth wire 4 mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipment’s etc at the other end including 15 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Pt-I. including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified & directed. Note :- (i) Earthing resistance required in earthing shall less than 2.0 Ohms after completion of work. All earthing shall be tested by the contractor in presence of Engr-in-Charge. Test result shall be recorded and signed by the contractor and Engr – in- Charge. If contractor fail to achieve the above result the same shall be rectified by the contractor without any extra cost to Govt. The earthing result will be required maintaining up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engg-in-Charge and contractor shall rectify the same. The quoted rates shall be deemed to include for above said provision. (ii) Quoted rates shall be deemed to be included for earth strip with protection pipe up to 7.5 length.
Supply & fixing integral 30W LED street light luminaire comprising of epoxy powder coated housing enclosed with glass cover in frame, IP 65 protection including taking down old unserviceable street light fitting of any make/type/rating and connecting up complete all as specified and as directed. Make:- Phillips / Crompton / C&S / Wipro .
Supply & fix 32mm dia bore GI bracket of length 0.9 metre including GI clamps size 30 X 4 mm with nuts, Bolts & washers including two coats of Aluminium paint on GI clamps complete all as specified and as directed .
Supply & fix in repair Junction box of size 300mm x 450mm x170mm with Aluminium bus bar rating three phase 150 Amp and neutral 75 Amp, IP 65 having provision for metric knockouts for cable entry up to 70 Sq mm including GI clamps 30x 4mm thick, nuts, bolts & washers including two coat of Aluminium paint on GI clamps complete all as specified and directed. Make:- HENSEL (Cat No : K - 7004) or any equivalent make as approval by GE.
Supply & fix in repair Junction box of size 210mm x 310mm x116mm, with 4 terminal of rating 63 Amp, IP 65 having provision for metric knockouts for cable entry up to 50 Sq mm including GI clamps 30x4mm thick, nuts, bolts & washers complete including two coats of Aluminium paint on GI clamps all as specified and directed. Make: HENSEL (Cat No : K - 9504) or any equivalent make as approval by GE.
Supply & fix in repair Junction box of size 200mm x 160mm x98mm with 4 terminal of rating 32 Amp, IP 65 having provision for metric knockouts for cable entry up to 25 Sq mm including GI clamps 30x4mm thick, nuts, bolts & washers including two coats of Aluminium paint on GI clamps complete all as specified and directed. Make: HENSEL (Cat No : K - 9255) or any other equivalent make as approval by GE.
Supply & fix in repair out door type straight through joint heat shrinkable type for LT XLPE / PVC 1100 volt grade cable and connecting the cable including testing on load complete all as specified & directed for the following size of cables:-
LT cable size 3.5 X 25 to 70 Sq mm
LT cable size 3.5 X 95 to 185 Sq mm
Supply, Install, connecting & testing of KWH energy meter with LCD display suitable for HT 11000 Volt including optical port, with box complete all as specified and as directed. Make:- SECURE METERS LIMITED or any other equivalent make as approval by GE.
Supply & fix Solar Smart LED light fitting of capacity 30 watt with fibre reinforced plastic body encases PV panel, LED Lamp, suitable rating of Lithium battery and charge controller driver etc including clamps, nuts, bolts & washers and taking down old unserviceable light fitting deposite to AGE E/M store yard complete all as specified & directed. Make:- Wipro/ Phillips/ Crompton/ Havells
Supply and lay fly ash bricks of designation 75 kg per cm square, old size for protection of under ground cable in trenches all as specified and directed.
Supply & fix GI clamps of size 25 X 3 mm thick for GI pipes fixed on poles/wall and like including nuts, bolts & washers complete all as specified and directed.
Supply & fix in repairs MCCB, 415 Volts, 4 pole with thermal magnetic release of the following rating. Make:- legrand / L&T / Havells / C&S .
MCCB 400 Amp , Breaking capacity 50 KA
MCCB 315 Amp , Breaking capacity 36 KA
MCCB 200 Amp , Breaking capacity 36 KA
MCCB 100 Amp , Breaking capacity 16 KA
MCCB 63 Amp , Breaking capacity 16 KA
Supply & connecting of PVC aluminium wire twin core size 2.5 Sq mm complete all as specified & directed .
Note:- (i) The amount against Schedule of Credit on Page No. 28 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Paragon Electrotechnics
AFSA ENGINEERS PVT LTD
Vee kay construction
AMBIKA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .