Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
2 Oct 2024, 6:00 pmClosed
GE South Pune
NO 1 GEN BHAGAT MARG PUNE 40
8595 REPAIRS MAINT OF LT PANELS FEEDER PILLARS CABLES PROTECTIVE SYSTEM APFC PANEL LT DISTRIBUTION SYSTEM AND OTHER CONNECTED WORKS IN NEW CHSC OTHER CONNECTED AREA UNDER AGE EM II OF GE SOUTH PUNE
2024_MES_670114_1
8595 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE South Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹98,000
Yes
18 Nov 2024
2 Sept 2024
4 Oct 2024
2 Sept 2024
2 Oct 2024
18 Sept 2024
Amount
M&L for finding of fault in LT underground cable including testing cable from panel to fault location including taking shut down and opening of cable from both side of bus bar Panel / LT Panel / MCCB / ACB / Transformer etc and re-terminating the same cable in the same bus bar Panel / LT Panel / MCCB / ACB etc according to existing system after completion of fault finding / testing work complete all as directed by Engr-in-charge for any size of cable. Note:- Finding of one fault and make it functional in all respect will be measured as one job.
S&F in replacement of heat shrinkable Straight through jointing kit suitable for LT 1.1 KV XLPE cables of 240 to 400 Sqmm 3.5 core size including all required accessories complete all as specified and directed. Make :- Denson / M Seal / 3M
S&F in replacement of heat shrinkable Straight through jointing kit suitable for LT 1.1 KV XLPE cables of 150 to 185 Sqmm 3.5 core size including all required accessories complete all as specified and directed. Make :- Denson / M Seal / 3M
S&F in replacement of heat shrinkable Straight through jointing kit suitable for LT 1.1 KV XLPE cables of 70 to 120 Sqmm 3.5 core size including all required accessories complete all as specified and directed. Make :- Denson / M Seal / 3M
S&F in replacement of heat shrinkable Straight through jointing kit suitable for LT 1.1 KV XLPE cables of 16 to 50 Sqmm 3.5 core size including all required accessories complete all as specified and directed. Make :- Denson / M Seal / 3M
Supply, laying, testing and commissioning of 400 Sqmm 3.5 core LT cables, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 Part-I, including cable glands, crimping type cable lugs in LT panel / MCCB in building etc to suit the cable laid in trenches / fixed to poles / drawn through pipes etc including taking down of old unserviceable cable of any type complete all as specified and directed.
All as per item No 6 above but 300 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 240 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 185 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 150 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 120 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 95 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 70 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 50 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 35 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 25 sq mm 3.5 core complete all as specified and directed.
All as per item No 6 above but 16 sq mm 4 core complete all as specified and directed.
All as per item No 6 above but 10 sq mm 2 core complete all as specified and directed.
All as per item No 6 above but 10 sq mm 4 core complete all as specified and directed.
All as per item No 6 above but 6 sq mm 2 core complete all as specified and directed.
All as per item No 6 above but 6 sq mm 4 core complete all as specified and directed.
Excavation in trenches in hard / dense soil n. exc. 1.5m wide and n.exc. 1.5m in depth and getting out complete all as specified and directed.
Excavation in trenches in soft/dis-integrated rock n. exc. 1.5m wide and n. exc. 1.5m in depth and getting out complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5 mtr above starting point all as specified and directed.
M&L for laying of half round reinforced concrete pipe, of internal dia 150 mm and outer dia 200 mm, half round for bottom and half round for top and before laying of able excavated area shall be leveled complete all specified and directed. Note:- 01 Half round top and 01 half round bottom together will be considered as one running meter.
Supply and laying 80mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of underground cable including necessary fittings and fixtures & including sealing ends with hessian cloth impregnated with bituminous compound in ground fixed with suitable clamps, bolt / nuts etc for fixing on walls, poles etc complete all as specified and directed.
All as per item No 27 above but 50 mm bore complete all as specified and directed.
All as per item No 27 above but 40 mm bore complete all as specified and directed.
Material and labour for cutting of existing road/ hard standing by providing suitable T&P to make suitable size bore for laying 80/50/40 mm dia pipe in road crossing etc. with and including making good the disturbed surface of road as per existing surface finishes complete all as specified and directed by Engr-In-Charge
Supply, fixing, testing and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich bus duct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for indoor installation including connection with terminal with and including all accessories as required at site, copper laminated flexible connections, phase crossover, bends, adopter box, bus bar supports, insulating materials all mounting accessories as per site requirement complete. All bus bar joints shall have double headed bolt on connection plate, bus bar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material will be provided as per OEM complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supply, fixing, testing and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich bus duct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for outdoor installation including connection with terminal with and including all accessories as required at site, copper laminated flexible connections, phase crossover, bends, adopter box, bus bar supports, insulating materials all mounting accessories as per site requirement complete. All bus bar joints shall have double headed bolt on connection plate, bus bar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material will be provided as per OEM complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supply, fixing, testing and commissioning of aluminium enclosure of 2500 Amps ratings, TPN, aluminium sandwich bus duct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for indoor installation including connection with terminal with and including all accessories as required at site, copper laminated flexible connections, phase crossover, bends, adopter box, bus bar supports, insulating materials all mounting accessories as per site requirement complete. All bus bar joints shall have double headed bolt on connection plate, bus bar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material will be provided as per OEM complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
M&L for painting of supporting structure for bus bar trunking system with the help of spray painting machine or any suitable means without disturbing the existing structure with two coats of synthetic enamel paint of existing colour including preparation of surfaces by scrapping old paint form surface including one coat of red oxide primer on complete all as specified as directed by Engr-in charge Note:- The contractor will be provided all the safety equipments such as safety belt to his workers, required T&P and necessary scaffolding etc and the cost of the same will be deemed to be included in unit quoted rates of this item.
M&L for maintenance free grounding Solution set earthing comprising of 17.2 mm pure copper earthing rod, 3m long, copper terminal size of 40x6mm with 2 Nos. M8 holes for termination. Electrode must be tested for a short circuit test of minimum 40 KA at CPRI / NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 m. The bore drilling will be done with the help of a Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in a properly mixed condition. The Earth pit cover Square 300x300x240 mm size to be provided to cover the earth pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons, complete all as directed by Engr-in-charge. Make : "U-PROTEC" earthing Pvt Ltd or equivalent in Ashlok safe earthings electrode Ltd /JEF technology NOTE :- (a) Rates of boring 3.50 m for earth electrode, copper strip 25x3 mm up to 7.5 Mtr from earth electrode is deemed to be included in quoted rates. (b) On testing, after completion, if the earth resistance <5 ohms is not obtained, earthing will be rejuvenated at no extra cost to the Department untill the desired earth resistance is obtained.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 Copper strip, complete all as specified and directed.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on wooden batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 50x6mm galvanised iron strip complete all as specified & as directed.
Supply and fix copper strip of 20x3mm size with saddles and fixing screws for roof conductors and down conductor above ground complete all as specified & as directed.
Supply, laying, testing and commissioning of 4 Core x 25 Sqmm size XLPE insulated, and overall PVC sheathed, armoured, (Heavy duty) copper conductor cables suitable for working voltage up to and including 1100 Volts, laid and tied on overhead cable trays or laid and tied over mild steel supports in masonry trenches with and including providing mild steel supports & clamps of suitable size and shape for fixing to supports or buried in ground including termination with single compression brass glands including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge. Note:- Excavation earth work will be measured and paid for separately
All as per item No. 40 above but 4 Core x 16 Sqmm "CU" including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge.
All as per item No. 40 above but 4 Core x 10 Sqmm "CU" including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge.
All as per item No. 40 above but 2 Core x 10 Sqmm "CU" including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge.
All as per item No. 40 above but 2 Core x 6 Sqmm "CU" including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge.
All as per item No. 40 above but 1 Core x 150 Sqmm "CU" including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge.
All as per item No. 40 above but 1 Core x 70 Sqmm "CU" including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge.
All as per item No. 40 above but 1 Core x 50 Sqmm "CU" including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge.
All as per item No. 40 above but 1 Core x 35 Sqmm "CU" including taking down of old unserviceable cable of any type complete all as specified and directed by Engr-in-charge.
S & F in replacement of Aluminium Tube terminals (Lugs) suitable for 10 Sqmm cable, heavy duty by opening LT Cable from Panel and Crimping / fixing the Lugs with crimping tools and re-terminated the same LT Cable to existing MCB / MCCB according to existing system including taking down of old one complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 16 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 25 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 35 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 50 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 70 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 95 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 120 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 150 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 185 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 240 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 300 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 49 above but 400 Sqmm complete all as specified and directed by Engr-in-charge
S & F in replacement of Copper tube terminals (Lugs), suitable / compatible to 4 to 16 Sqmm Cu stranded LT Power cable including disconnecting the Power Cable from LT Panel / MDB etc and reconnecting the same according to existing system after change of Cu Lugs etc complete all as specified and directed by Engr-in-charge
All as per item No. 62 above but 25 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 62 above but 35 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 62 above but 50 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 62 above but 70 Sqmm complete all as specified and directed by Engr-in-charge
All as per item No. 62 above but 150 Sqmm complete all as specified and directed by Engr-in-charge
Design, supplying, installation, testing and commissioning of free standing floor mounted, dust and vermin proof LT Panel of suitable size for outdoor installation, factory made, both front & rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted with epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkable sleeves with 600 mm depth of the panel. The panel shall be modular / cubical type with bus chamber cable alloy and provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door, front & rear openable with locking arrangement and suitable for 1100 Volts grade, 3 phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made from angle iron of size 50x50x6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level with and including the following provisions including taking out of old unserviceable panels etc, removing of cables and connecting to new panels with all required material such as glands, lugs etc complete all as specified and directed by Engr-in-charge:-
Item no.68 (Contd........) INCOMING :- (a) MCCB 4 pole, 400 Amps capacity rupturing capacity 36 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No. incoming OUTGOING :- (a) MCCB 4 pole 200 Amps capacity rupturing capacity 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos. out going (b) MCCB 3 pole100 Amps capacity rupturing capacity 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos. out going (c) MCCB 3 pole 63 Amps capacity rupturing capacity 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos. out going (d) LT Danger notice plate -01 No (e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland suitable for LT cables.
S & F in replacement Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size 200 x 150 mm for LT Supply including taking down of old existing complete all as specified and directed.
Supply only 11 KV grade EN- 13319-2000 Rubber insulating seamless rubber Hand safety gloves Item Part No- JG of Jyot manufacturer or equivalent make complete all as specified and directed by Engr-in-Charge.
Supplying, installation, testing & commissioning of 600 Amps, 30 KA aluminum enclosure, TPN, high electrolytic conductivity aluminium conductor, sandwich Bus bars covered with 2 layers of Myler insulation, No coloured sleeves, suitable for operation on 415Volts / 650 Volts, 3 Phase, 4 wire, 50 cycles, AC supply system of Rising Main. The construction should be dust and vermin proof, IP 54 protection, in epoxy powder coated aluminum construction rated for 45 degrees, C ambient temperature complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supplying, installation, testing & commissioning of 400 Amps, 20 KA aluminum enclosure, TPN, high electrolytic conductivity aluminium conductor, sandwich Bus bars covered with 2 layers of Myler insulation, No coloured sleeves, suitable for operation on 415Volts / 650 Volts, 3 Phase, 4 wire, 50 cycles, AC supply system of Rising Main. The construction should be dust and vermin proof, IP 54 protection, in epoxy powder coated aluminum construction rated for 45 degrees, C ambient temperature complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supplying, installation, testing & commissioning of 200 Amps, 20 KA aluminum enclosure, TPN, high electrolytic conductivity aluminium conductor, sandwich Bus bars covered with 2 layers of Myler insulation, No coloured sleeves, suitable for operation on 415Volts / 650 Volts, 3 Phase, 4 wire, 50 cycles, AC supply system of Rising Main. The construction should be dust and vermin proof, IP 54 protection, in epoxy powder coated aluminum construction rated for 45 degrees, C ambient temperature complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supplying, installation, testing & commissioning of 400 Amps, tap off box suitable for tapping off at intervals along with 400 Amps, 4 Pole, MCCB, 35 KA breaking capacity complete all as specified and as directed Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supplying, installation, testing & commissioning of 200 Amps, tap off box suitable for tapping off at intervals along with 200 Amps, 4 Pole, MCCB, 25 KA breaking capacity complete all as specified and as directed Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supplying, installation, testing & commissioning of 125 Amps, tap off box suitable for tapping off at intervals along with 125 Amps, 4 Pole, MCCB, 25 KA breaking capacity complete all as specified and as directed Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supplying, installation, testing & commissioning of 100 Amps, tap off box suitable for tapping off at intervals along with 100 Amps, 4 Pole, MCCB, 25 KA breaking capacity complete all as specified and as directed Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supplying, installation, testing & commissioning of 63 Amps, tap off box suitable for tapping off at intervals along with 63 Amps, 4 Pole, MCB, 10 KA breaking capacity complete all as specified and as directed Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
Supplying, installation, testing & commissioning of 40 Amps, tap off box suitable for tapping off at intervals along with 40 Amps, 4 Pole, MCB, 10 KA breaking capacity complete all as specified and as directed Engr-in-Charge. Make- L&T or equivalent in Legrand / ABB / Schenider
S&F in repairs APFC controller, 14 step suitable for automatic correction of power factor suitable for 415 volts, 3 phase power supply complete with necessary fixing complete all as directed by Engr-in-charge. Make- L&T Cat no-etaSMART 14R or equivalent in ABB / Siemens.
S&F in repairs APFC controller, 8 step suitable for automatic correction of power factor suitable for 415 volts, 3 phase power supply complete with necessary fixing complete all as directed by Engr-in-charge. Make- L&T Cat no-etaSMART 14R or equivalent in ABB / Siemens.
S&F in repairs ultra heavy duty capacitors bank cylindrical series 5 KVAR suitable for automatic correction of power factor suitable for 415 volt, 3 phase power supply complete with necessary connection including taking down of old unserviceable capacitor bank of any type complete all as directed by Engr-in-charge. Make- L&T Cat no-LTCCU or equivalent in ABB / Epcos.
S&F in repairs ultra heavy duty capacitors bank cylindrical series 10 KVAR suitable for automatic correction of power factor suitable for 415 volt, 3 phase power supply complete with necessary connection including taking down of old unserviceable capacitor bank of any type complete all as directed by Engr-in-charge. Make- L&T Cat no-LTBCU or equivalent in ABB / Epcos.
S&F in repairs ultra heavy duty capacitors bank cylindrical series 25 KVAR suitable for automatic correction of power factor suitable for 415 volt, 3 phase power supply complete with necessary connection including taking down of old unserviceable capacitor bank of any type complete all as directed by Engr-in-charge. Make- L&T Cat no-LTCCU or equivalent in ABB / Epcos.
S&F in repairs ultra heavy duty capacitors bank cylindrical series 50 KVAR suitable for automatic correction of power factor suitable for 415 volt, 3 phase power supply complete with necessary connection including taking down of old unserviceable capacitor bank of any type complete all as directed by Engr-in-charge. Make- L&T Cat no-LTBCU or equivalent in ABB / Epcos
S&F in repairs Capacitor duty Contactors sutable for 5 KVAR capacitor bank complete all as specified and directed by Engineer-in-Charge. Make- L&T /Siemens/Schneider
S&F in repairs Capacitor duty Contactors sutable for 10 KVAR capacitor bank complete all as specified and directed by Engineer-in-Charge. Make- L&T /Siemens/Schneider
S&F in repairs Capacitor duty Contactors sutable for 25 KVAR capacitor bank complete all as specified and directed by Engineer-in-Charge. Make- L&T /Siemens/Schneider
S&F in repairs Capacitor duty Contactors sutable for 50 KVAR capacitor bank complete all as specified and directed by Engineer-in-Charge. Make- L&T /Siemens/Schneider
Supply and Fix in repairs digital voltmeter 0-500 volts square type complete with necessary fitings & fixtures and 3 nos of CTs complete all as specified and as directed by Engr-in-charge. Make: L&T/Siemens/Schneider
Supply and Fix in repairs digital ammeter 0-400 amps square type complete with necessary fittings and fixtures and 3 nos of CTs complete all as specified and as directed by Engr-in-charge. Make: L&T/Siemens/Schneider
S&F in replacement of Digital Multifunction Meter LED, Accuracy Class 1, with RS 485 Parameters V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours etc. without disturbing other accessories and taking down of old unserviceable meters etc complete all as specified and directed by Engr-in-charge.
S&F in replacement Electronic Timer 3 Sec to 120 Sec, 240 VAC model, 2ASDTO of Make – L & T or equivalent as approved including taking down of existing one complete all as directed by Engr-in-Charge.
M&L for replacement of Thermal overload relay with current range 3.5 A to 5.2 A Type RTO-1 suitable for MO contactor Make L&T or equivalent as approved including taking down of existing one complete all as directed by Engr-in-Charge.
M&L for replacement of Thermal overload relay with current range 6.7 A to 9.7 A Type RTO-1 suitable for MO contactor Make L&T or equivalent as approved including taking down of existing one complete all as directed by Engr-in-Charge.
S & F in replacement breaker control switch Trip-Neutral-Close type as per site requirement including taking down of existing one complete all as directed.
S&F in replacement of Push button as per sample Make-L&T or equivalent as approved including taking down of existing one complete all as directed.
S&F in replacement of indicator lamps LED type with holder suitable for panel control functions Make-L&T or equivalent including taking down of existing one complete all as specified and directed.
S&F in replacement front mounting add-on aux contact block 2NO + 2NC for MO contactors all as specified and directed. Make-L&T or equivalent including taking down of existing one complete all as specified and directed.
S&F in replacement of power contactor MO25 CONFIRMING TO IS/IEC 60947-4-1 Make-L&T or equivalent including taking down of existing one complete all as specified and directed.
S&F in replacement of power contactor MO32 CONFIRMING TO IS/IEC 60947-4-1 Make-L&T or equivalent including taking down of existing one complete all as specified and directed.
S&F in replacement of power contactor MO140 Conforming to IS/IEC 60947-4-1 Make-L&T or equivalent including taking down of existing one complete all as specified and directed.
S & F in replacement of control wiring of 1.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement of control wiring of 2.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S&F in repairs of CT cast resin type of ratio 100/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repairs of CT cast resin type of ratio 200/5 amps, of suitable VA burdena s per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repairs of CT cast resin type of ratio 500/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repairs of CT cast resin type of ratio 600/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repairs of CT cast resin type of ratio 800/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repairs of CT cast resin type of ratio 1600/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repairs of CT cast resin type of ratio 3200/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S&F in replacement of MCB, SP, 6-32 Amps,10 KA, 'C' series complete all as specified and as directed.
S&F in replacement of MCB, SPN, 6-32 Amps,10KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement of MCB, SPN, 40-63 Amps,10 KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement of MCB, TP, 25-63 Amps, 10 KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement of MCB, TPN, 16-32 Amps,10 KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement of MCB, TPN, 40-100 Amps,10 KA, 240V, 'C' series complete all as specified and as directed.
Supply & Laying in replacement of Synthetic Rubber Insulated Mats of size 2.0x1.0m and 2.5 mm thick suitable for Voltage upto 11KV working pressure conforms to IS 15652-2006 and applying adhesive to fix before laying the new one complete all as specified and directed. Make : Dozz or equivalent make as approved
Supply only insulation tape roll size 18mm width and 6.5 Mtr length of superior quality complete all as directed. Make- Anchor / Steelgrip
Supply only waterproof Insulation tape roll of superior quality and suitable size complete all as directed.
Supply only Lock suitable for panels with 3 keys of superior quality as per sample as approved by Engr-in-charge complete all as directed. Make -Godrej Nav-tal 7 Lever Shut Height 5cm (50mm) (3 Keys) or equivalent
S & F in replacement of cylindrical panel locks of existing / suitable size or as per sample including drilling, cutting and welding etc in panel sheets without disturbing to other existing fitments including taking down old existing one complete all as specified and directed.
S & F in replacement of old broken Cold rolled mild steel Hinges of existing LT Panel / Feeder Pillar / bus bar box etc of suitable size or as per sample including welding and painting to match with existing colour of Panel sheet etc complete all as specified and directed.
M&L for running welding of thickness n.exc. 6mm as in repairs to panels etc complete all as directed by Engr-in-charge.
S&F in repairs Automatic Transfer Switch 125 Amps rating fixed in existing panel as per existing and taking out of old unserviceable ATS complete all as specified and as directed. Make- ABB or equivalent in L&T / Schenider
S&F in repairs Automatic Transfer Switch 200 Amps rating fixed in existing panel as per existing and taking out of old unserviceable ATS complete all as specified and as directed. Make- ABB or equivalent in L&T / Schenider
S&F in repairs Automatic Transfer Switch 400 Amps rating fixed in existing panel as per existing and taking out of old unserviceable ATS complete all as specified and as directed. Make- ABB or equivalent in L&T / Schenider
S&F in repairs Automatic Transfer Switch 500 Amps rating fixed in existing panel as per existing and taking out of old unserviceable ATS complete all as specified and as directed. Make- ABB or equivalent in L&T / Schenider
S&F in repairs Automatic Transfer Switch 1000 Amps rating fixed in existing panel as per existing and taking out of old unserviceable ATS complete all as specified and as directed. Make- ABB or equivalent in L&T / Schenider
S&F in replacement of extended ROM type rotary switch suitable for mounting and controlling existing MCCB of any type / capacity complete all as specified and directed by Engr-in-charge
S&F in replacement of direct ROM type rotary switch suitable for mounting and controlling existing MCCB of any type / capacity complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 3 Pole, 415 Volts, 63 Amp to 100 Amp, 16 KA Breaking capacity, thermal magnetic release type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 63 Amp to 100 Amp, 16 KA Breaking capacity, thermal magnetic release type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 63 Amp to 100 Amp, 25 KA Breaking capacity, thermal magnetic release type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 63 Amp to 100 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 3 Pole, 415 Volts, 125 Amp, 16 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 125 Amp, 16 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 125 Amp, 25 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 125 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 160 Amp, 25 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 3 Pole, 415 Volts, 200 Amp, 25 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 200 Amp, 25 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 3 Pole, 415 Volts, 250 Amp, 25 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 250 Amp, 25 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 250 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 3 Pole, 415 Volts, 400 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 400 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 400 Amp, 50 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 500 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 630 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 630 Amp, 50 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 800 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
S & F in replacement MCCB 4 Pole, 415 Volts, 1000 Amp, 36 KA Breaking capacity, thermal magnetic release with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/ABB/Siemens
vishalconstruction (BID ID -3107765)
Adinath Technical Services (BID ID -3112789)
TULAJA ENTERPRISES (BID ID -3113391)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .