Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-I₹33.9 LAccepted-AOC | L-I | Accepted-AOC Bidder quoted lowest amount hence awarded | |
| 2 | L-II₹37.6 LRejected-AOC | L-II | Rejected-AOC Bidder rejected due to higher amount quoted |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
3 Feb 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh. Rohit Thakur, General Manager
RTDC,US, Club, Shimla-1
Construction of Vending Zones at Dhalli Chowk near HPPWD office (SH Construction of 15 unit Vending Zones)
2022_RTDCH_56051_1
RTDC/Vending Zones/2021/8502-8503 dtd 21/01/22
Open Tender
Construction Works
Item Rate
90 days
Dhalli
Read RFP for complete details
5 documents required · 5 mandatory
₹1,770
Yes
GENERAL MANAGER RTDC HP
₹60,000
Yes
23 Jan 2023
24 Jan 2022
3 Feb 2022
24 Jan 2022
3 Feb 2022
24 Jan 2022
90 days
Amount
Steel work in built up tubular in trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete as per direction of Engineer-in-Charge.
Providing and Fixing roofing of Polyurethane Foam Sandwiched between Pre painted 0.5mm(Zero Point Five mm) thick Galvanised Steel Sheets with panel thickness of 30/70mm(Thirty/Seventy mm) max upto Rib Tapered Trapezoidal Profiled roof to prevent the structure from rain water with in built features likes Boxes edges, which prevent the rain water from free falling and helps drive the panel type will come with desity of 40+-2Kg/cum(Fourty+-Two kg) and blowing agent as Cyclopentane. Fixing of 'L' and 'U' shaped pre painted Flashing of size (35x35mm)(Thirty five x Thirty Five mm),(35x35mm),(Thirty five x Thirty Five mm) as and if required for covering each and every corner complete with riveting done with pneumatic reveting machine, as per direction of Engineer-in-Charge.
Providing and Fixing wall of Polyurethane Foam Sandwiched between Pre painted 0.5mm thick Galvanised Steel Sheets with panel thickness of 50mm short Rib configuration for extra strength with off white colour. The panel type will be tongue and groove with density of 40+-2Kg/cum(Fourty +-Two kg) and blowing agent as Cyclopentane. The panels are unique tongue -n-groove joinery for air tight, effective panel to panel interlocking that is easy to install and provide effective sealing. High quality silicone sealant of white color will be applied thoroughly at each and every part of the structure in order to make it leakage proof and properly sealed as per the direction and entire statistaction of Engineer-in-Charge.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns using self drilling/ self tapping screws complete : as per direction of Engineer-in-Charge.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters as per direction of Engineer-in-Charge.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group C as per direction of Engineer-in-Charge.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required as per direction of Engineer-in-Charge.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required as per direction of Engineer-in-Charge.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required as per direction of Engineer-in-Charge.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required as per direction of Engineer-in-Charge.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required Single door-4 way as per direction of Engineer-in-Charge.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required Single pole. Cat-A as per direction of Engineer-in-Charge.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required Double pole. Cat-A as per direction of Engineer-in-Charge.
Earthing with G.I. earth plate 600 mmx600 mmx 6 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required as per direction of Engineer-in-Charge.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required as per direction of Engineer-in-Charge.
S/F Led Tubelight of syska or its equivalent approved make of complete with connections etc as required capable in all respects.Led tube 8 watt as per direction of Engineer-in-Charge.
S/F Led Bulk head of syska or its equivalent approved make of complete with connections etc as required capable in all respects.Led Bulk head 12 watt as per direction of Engineer-in-Charge.
Piyush Gupta
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .