| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹49.5 L+₹2.7 L (5.85%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹52.1 L+₹5.4 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹53.6 L+₹6.9 L (14.7%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L4 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | M/S SHIVA TRADERS L1 | HARNAM SINGH ANIL SINGH L4 | PARAS BROTHERS L2 | S.R ENGINEER WORKS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Calibration of IDMT relay by conducting primary injection / secondary injection tests, checking of current transformer, rectification of defects in control wiring, necessary adjustment/setting of plug and time multiplier settings of the relay for proper tripping of circuit breakers through CTs, relays and tripping coils complete all as specified and as directed. Note: The contractor shall arrange all necessary testing kits, testing equipments, tools etc and shall also prepare necessary test reports and submit to the department before claiming payment in RAR / FB. Hiring charges of testing kit and equipment is deemed to be included in the quoted rate. Testing, tuning and setting of relay shall be carried out in the presence of Engineer-in-Charge. | 20 | Each Job | 2,000 ₹40,000 Lowest | 5,000 ₹1,00,000 | 5,000 ₹1,00,000 | 4,950 ₹99,000 |
| 2.00 | Supply and fix in replacement of Non-directional IDMT Two Over Current and One Earth Fault relay suitable for 1 Amp or 5 Amp CT secondary for 11 KV system suitable for existing VCB panel complete all as specified and as directed by Engineer-in-Charge. | 15 | Each | 17,500 ₹2,62,500 | 26,000 ₹3,90,000 | 15,000 ₹2,25,000 Lowest | 25,900 ₹3,88,500 |
| 3.00 | S&F in replacement of Master Trip Relay suitable for 1 Amp or 5 Amp CT secondary for 11 KV system suitable for existing VCB panel complete all as specified and as directed by Engineer-in-Charge. | 10 | Each | 5,000 ₹50,000 Lowest | 10,500 ₹1,05,000 | 8,000 ₹80,000 | 10,300 ₹1,03,000 |
| 4.00 | Supply and fix in replacement of Power Pack with 15 minutes backup suitable for 11 KV VCB complete all as specified and directed by Engineer-in-Charge. | 4 | Each | 8,500 ₹34,000 Lowest | 17,000 ₹68,000 | 11,000 ₹44,000 | 17,000 ₹68,000 |
| 5.00 | Servicing and overhauling of 33/11 KV Vacuum Circuit Breaker and Ring Main Unit (RMU) 3 way to 6 way of any rating and any make by carefully drawing out the breaker from panel, degreasing and cleaning all moving parts, checking the condition of vacuum interrupters, male & female contacts, flexible connection, spring charging motor, gear assembly, tripping coil, timer, control wiring, operations of breaker both electrically and mechanically, inspecting all bolts, nuts, pins and collar pins etc and replacing the defective parts if any, applying grease to all moving parts, gears and trolley and petroleum jelly to male & female contacts and re-assembling, refixing and testing for smooth functioning of breaker complete all as specified and directed by Engineer-in-Charge. Note: The spare parts required shall be measured and paid separately as "Supply Only" and the labour part shall deemed to be included in the quoted rate. | 64 | Each Job | 6,000 ₹3,84,000 | 5,500 ₹3,52,000 | 3,100 ₹1,98,400 Lowest | 5,800 ₹3,71,200 |
| 6.00 | Supply only in replacement of Vacuum Interrupter suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB). | 14 | Each | 11,000 ₹1,54,000 | 5,100 ₹71,400 Lowest | 11,000 ₹1,54,000 | 5,200 ₹72,800 |
| 7.00 | Supply only in replacement of female contact suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB). | 10 | Each | 3,000 ₹30,000 | 1,300 ₹13,000 | 1,500 ₹15,000 | 1,250 ₹12,500 Lowest |
| 8.00 | Supply only in replacement of flexible copper strip connection suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB). | 10 | Each | 2,000 ₹20,000 | 800 ₹8,000 | 1,100 ₹11,000 | 780 ₹7,800 Lowest |
| 9.00 | Supply only in replacement of spring charging motor suitable for existing make and model of 33 KV Vacuum Circuit Breaker (VCB). | 2 | Each | 35,000 ₹70,000 | 14,500 ₹29,000 Lowest | 25,000 ₹50,000 | 14,800 ₹29,600 |
| 10.00 | Supply only in replacement of spring charging motor suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB). | 4 | Each | 6,500 ₹26,000 Lowest | 7,400 ₹29,600 | 11,000 ₹44,000 | 7,500 ₹30,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
28 Aug 2025, 6:00 pmClosed
SHRI ANIL KUMAR, IDSE, SE, CWE
HQ CWE JHANSI
REPAIR MAINTENANCE VCB RMUS AND GOD AND OTHER CONNECTED WORKS AT ALL SUB STNS UNDER AGE EM GE JHANSI
2025_MES_722370_1
CWE/JHA/J/TOKEN/21 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JHANSI
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE JHANSI
₹1 L
Yes
13 Nov 2025
24 Jul 2025
30 Aug 2025
24 Jul 2025
28 Aug 2025
14 Aug 2025
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .