Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.7 LAccepted-AOC 429 EASWARANKOVILPATHU MEENATCHIPURAM MANNARSAMUTHRAM THIRUVAIYARU 613 101 | THIRUVAIYARU | THANJAVUR | TAMIL NADU | 613101 | 1 | Accepted-AOC ACCEPTED | |
| 2 | Rejected-Technical 3 19A AGRAHARAM KARUKUDI RAYAMPETTAL POST THIRUVALYARU 613 204 | THIRUVALYARU | THANJAVUR | TAMIL NADU | 613204 | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹4,500
Closing Date
18 Jul 2024, 3:00 pmClosed
Executive Officer Town Panchayat
172 50 no road thirukattupalli town panchayat
Retrofitting of Community Toilet at Onepathuveali Ayyanar Kovil Vettipathai
2024_DTP_462843_1
0217/2024/A1
Open Tender
Civil Works - Buildings
Works
Retrofitting of Community Toilet at Onepathuve
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹4,500
Yes
19 Aug 2024
15 Jul 2024
18 Jul 2024
15 Jul 2024
18 Jul 2024
15 Jul 2024
Plastering walls with cement mortar 1:5 (One cement five M Sand) 12mm thick in all floors and all exposed surfaces including cost and conveyance of materials to site and all labour charges,Curing etc complete as per standard specification.
Special Plastering with cement mortar 1:3 (One cement three M Sand) 10mm thick including cost and conveyance of materials to site and including all labour charges etc complete and as directed by department officiers etc complete as per standard specification.
Dadooing sides of walls with Glazed design tiles of size 200 x 200 x 6 mm set in Cement mortar 1:3 _ 20 mm thick and pointed with the same colour cement including cost and conveyence of all materials , labour charges etc complete as per standard specification.
Supplying and fixing over the floors best quality of scratch ceramic tiles of 30 c.m x 30c.m x 6mm size of approved colour laying with cement mortor 1:3 mix pointing the joints with colour pigments etc. Complete.
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
Supply and fixing of PVC pipe and specials complete complying with standard specifications and as directed by the departmental officers etc complete as per standard specification.
For 110 mm dia pipe
For 110 mm dia PVC Elbow
For 110 mm dia PVC Tee
For 25 mm dia pipe
For 25 mm dia PVC Elbow
For 25 mm dia PVC Tee
For Tap
Supplying and fixing in position white glazed Indian water closet of size 580 X 440mm of Orissa type of approved quality with 'P' or 'S' trap with M Sand cushion and forming flooring alround the closet using 40mm broken brick jelly lime concrete 1:2:5 ; 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes by dismandling masonry / RCC works and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers etc complete as per standard specification.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris, putty, wherever required etc., complete complying with standard specification.
Wiring with 2 x 2.5 sq.mm PVC unsheathed Sc.alu. cable of 650V grade in suitable TW Fillets on wall and ceiling with PVC accessories and with TW switch box with painting of suitable colour light point and Fan point. SD 16
Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K. Lite) suitable for incandescent lamp with 60 W bulb, wire and making good of the concealed portion with suitable colour SD 83
Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour SD 42
Supplying and fixing in position best Indian make white glazed earthenware WASH HAND BASIN of 560x406mm with a a pair of C.I. Brackets, 15mm dia C.P. Pillar tap, 32mm G.I. Waster water pipe, 32mm dia C.P. Brass waster coupling, plug with chain, 15mm dia PVC connection, 15mm G.M. wheel valve with ISI mark and necessary G.I. union and G.I. Elbow, including fixing wash hand basin in position with white lead, clamps, teakwood plugs, screws, rubber washer etc., complete without any leakage complying with standard specifications.
G SENTHAMIZH SELVAN (BID ID -1083467)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_550043.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .