| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹54.1 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 1 | Accepted-AOC Due to credit | |
| 2 | 2₹59.7 L+₹4.4 L (7.85%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹60.0 L+₹4.6 L (8.23%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹63.1 L+₹7.7 L (13.9%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | 4 | Rejected-Finance Being other than L-1 |
Tender Value
₹58.2 L
EMD Value
₹1.2 L
Closing Date
7 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
ADDITION/ALTERATION AND IMPROVEMENT TO EM INFRASTRUCTURE MAP II AT CERTAIN MD ACCN UNDER GE AF ADM AREA AT AF STATION AGRA
2022_MES_555922_1
8000-2002/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class C
cat b i
8 documents required · 8 mandatory
₹1,000
GE AF Adm Area Kheria Agra
₹1.2 L
Yes
1 Dec 2022
4 Oct 2022
9 Nov 2022
4 Oct 2022
7 Nov 2022
26 Oct 2022
4 Oct 2022 - 25 Oct 2022
Amount
Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for laying for cables etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Taking out old unserviceable LT UG cables of size 10 to 70 Sq mm 2/3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of Schedule) complete all as directed.
Taking out old unserviceable LT UG cables of size 95 Sqmm 3.5 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of Schedule) complete all as directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 95 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 Sq mm 3.5 core complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sqmm 4 core complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 Sqmm 4 core complete all as specified and directed.
Supply and Laying including testing in floor/trenches or fixed on pole/wall XLPE LT UG cable PVC insulated, bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 10 Sqmm 2 core complete all as specified and directed.
Supply & laying double walled corrugated (DWC) HDPE duct pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 63 mm inner dia and 75 mm outer dia complete all as directed. Make :- Astral / JPC pipes Pvt Ltd./ Bhagwati Plastic & Agriculture Industries.
M&L for drilling suitable dia horizontal bore holes for insertion / laying of up to 80 mm bore DWC pipe of any description below/under road surface/floors etc. with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing strata after laying pipes complete all as specified and directed.
Supply, installation, testing and commissioning of 12.5 mtr High Mast System with solar LED light and accessarioes, Mast having hot dip Galvanized, inside & outside in single dip, with bottom 360 mm and top 150 mm and 3 mm thick without any circumferential welding including accessories for high mast with head frame of 40 NB ERW class-B- MS pipe having suitable arrangement for 6 luminaries. Supply of 06 Nos 24 mm dia, 850 mm long foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates, including earthwork 2.5 m x 2.5 m x 1.5 m, returning filling, PCC 1:4:8 approx 0.75 Cum, RCC 1:2:4 approx 3 Cum, steel TMT bars approx 125 Kg, anchor plate 8 mm square with holes, required for making foundation as per manufacturer instruction and drawing & as directed at site. Solar LED Lights - 06 Nos, must be “Lithium based Energy Efficient Integrated Solar Street Light of 60 Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Mono crystalline Solar PV Panel of 90Wp , Lithium Battery 11.1/12.8V, 44 AH with inbuilt BMS, IP 65, High brightness Warm White -LED (160- 180 lm/watt) lamp with Aluminum reflector for better light distribution and lux level 5 – 10, CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 18-20kg with adjustable MS clamp suitable for high mast pole mounting etc complete as required.
Protections: Short Circuit, overload, Reverse polarity and battery protections with Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant included Solar aviation obstruction LED light 3W with li ion battery and suitable solar modules - 01, stainless steel wire rope 6mm dia, grade AISI 316, 7/19 contruction 2 wire rope system, Method of operation - Motor or manual. Power tool shall be of integral type, motor capacity - 1.5 HP of single speed reversible type 3 phase 415 volts with suitable control panel for operation of power tool. complete all as specified and directed. Make:- Axxon (AXNHM-12.5MTR) or equivalent in Okaya power Pvt Ltd/Havells/Halonix Note :- (i) Cost of equipment for loading/ unloading of high mast at site and erection is deemed to be included in above quoted rate.
Taking down existing old U/s panel board with all accessories and Supply, installing, erecting, testing and commissioning, factory made and tested LT Panel board CPRI approved OEM made, Suitable size (without Canopy & Base Channel), Out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminum busbars installed on porcelain/SMC insulators and all inter connection between main busbars as well as outgoing feeders shall be carried out with TPN Aluminum busbar of rating not less then 1.5 times rated capacity of individual out going feeders. The panel shall be dust and vermin proof, IP 56 class protection and made of 3 mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, bottom channel of size: 70x40x5 mm powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, fixing 2 Nos. danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel etc with voltage and danger indicated in Hindi and English, with double door shutter and locking arrangement (including provn of 65mm Godrej(Freedom) stranded lock, internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 30 cm above the nearest ground level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 400Sqmm by drawing /digging out cable from loops in trenches/ ducts outside the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size Aluminum lugs for terminal connections of cables, necessary PCC foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate/ glands. The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old Skelton type panel with control switches complete all as specified and directed. The scope of work includes the following Items:- NOTE:(i) Panel Builder should submit all Certificates before executing the job
Taking down existing old U/s panel board with all accessories and Supply, installing, erecting, testing and commissioning, factory made and tested LT Panel board CPRI approved OEM made, Suitable size (without Canopy & Base Channel), Out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminum busbars installed on porcelain/SMC insulators and all inter connection between main busbars as well as outgoing feeders shall be carried out with TPN Aluminum busbar of rating not less then 1.5 times rated capacity of individual out going feeders. The panel shall be dust and vermin proof, IP 56 class protection and made of 3 mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, bottom channel of size: 70x40x5 mm powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, fixing 2 Nos. danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel etc with voltage and danger indicated in Hindi and English, with double door shutter and locking arrangement (including provn of 65mm Godrej(Freedom) stranded lock, internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 30 cm above the nearest ground level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 400Sqmm by drawing /digging out cable from loops in trenches/ ducts outside the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size Aluminum lugs for terminal connections of cables, necessary PCC foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate/ glands. The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old Skelton type panel with control switches complete all as specified and directed. The scope of work includes the following Items:- NOTE:(i) Panel Builder should submit all Certificates before executing the job
Dismantling and taking down old unserviceable Meter Box panel after taking out old serviceable Energy Meters of any type / capacity after necessary disconnection of electrical wires/ XLPE cable etc and marking the Quarter No on each meters with parmanent marker pen and keeping in safe custody for re-fixing and reconnection in existing meter in new panel cabinet as per item No. 17 to 19 all as specified and directed.
Design, Supply, installation, testing and commissioning of indoor type wall mounting size min (980X 800X245 mm), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 05 nos with locking arrangement. (b) Copper Bus Bar of 1.5 time of incomming duly mounted on FRP / DMC insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeve of standard colour code - 4 Nos. (c) Four pole MCCB 100 Amps with breaking capacity 25 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incoming side - 01 No. (d) MCB DP 40 Amp 10 KA , C Curve - 5 Nos (To be connected with 5 Nos Meters) (e) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (f) 16 Nos terminal blocks provided for output supply. (g) MCCB/MCB Nos Operated by flip Cover
(h) LED Indicating lamp 22 mm - 03 Nos. (j) Internal wiring with 1100Volt grade FRLSH PVC insulated multiflexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- (i) MCCB to Bus Bar - 16.0 Sqmm (ii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 Sqmm (iii) Bus Bar to LED Lamp - 1.5 Sqmm (k) Dial type DIN rail mounting, Analog Timer Switch 16 Amps suitable 240 Volt AC 50Hz, with battery back up up to 24 Hrs programmable type with 1 NO & 1 NC output contact - 01 No. Make : L&T/ legrand/ ABB Note : Re-fixed the energy meter in this new meter cabinet including all necessary electrical connection. Make of polycarbonate thermoplastic enclouser:- Hensel / Schneider/ L&T/Siemens
Design, Supply, installation, testing and commissioning of indoor type wall mounting size min (980X 650X245 mm), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 04 nos in separate chamber with locking arrangement. (b) Four pole MCCB 63 Amps with breaking capacity 25 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incoming side - 01 No. (c) MCB DP 32 Amp 10 KA , C Curve - 4 Nos (To be connected with 4 Nos Meters) (d) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (e) 10 Nos terminal blocks provided for output supply. (f) MCCB/MCB Nos Operated by flip Cover
(g) LED Indicating lamp 22 mm - 03 Nos. (h) Internal wiring with 1100Volt grade FRLSH PVC insulated multiflexible copper wire of sizes duly crimped with copper lugs of 6 Sqmm Cable . (j) Dial type DIN rail mounting, Analog Timer Switch 16 Amps suitable 240 Volt AC 50Hz, with battery back up up to 24 Hrs programmable type with 1 NO & 1 NC output contact - 01 No. Make : L&T/ legrand/ ABB Note : Re-fixed the energy meter in this new meter cabinet including all necessary electrical connection. Make of polycarbonate thermoplastic enclouser:- Hensel / Schneider/ L&T/Siemens
Design, Supply, installation, testing and commissioning of indoor type wall mounting size min (980X 500 X 245 mm), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 03 nos in separate chamber with locking arrangement. (b) Four pole MCCB 63 Amps with breaking capacity 25 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incoming side - 01 No. (c) MCB DP 40 Amp 10 KA , C Curve - 3 Nos (To be connected with 3 Nos Meters) (d) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (e) 10 Nos terminal blocks provided for output supply. (f) MCCB/MCB Nos Operated by flip Cover
(g) LED Indicating lamp 22 mm - 03 Nos. (h) Internal wiring with 1100Volt grade FRLSH PVC insulated multiflexible copper wire of sizes duly crimped with copper lugs of 6 Sqmm Cable . Note : Re-fixed the energy meter in this new meter cabinet including all necessary electrical connection. Make of polycarbonate thermoplastic enclouser:- Hensel / Schneider/ L&T/Siemens
M&L in replacament of existing old unsv earthing with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earth lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe light grade with funnel and wire mesh, complete all as per SSR with PCC chamber, 50mm thick RCC cover in (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way, adequate qty of charcoal dust and salt layers all around the earth plate, including earth work in any type of soil, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
M&L for removal of existing old unsv earthing complete and providing new earthing with galvanised steel earth plate electrode, 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal, salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way including earth work in any type of soil , removal of surplus soil to a distance n.exc 50 m and connecting, testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
S&F in replacement sub main wiring with two single core PVC insulated (FRLSH) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLSH) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 25 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in replacement sub main wiring with two single core PVC insulated (FRLSH) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLSH) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 25 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
M&L for PCC 1:3:6 type C 2 ( using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC1:3:6 Type C 2 (using 40mm graded stone aggregate) as in coping of poles etc. including necessary formwork complete all as specified and directed.
S&F including testing Lithium based Energy Efficient integrated Solar street lights 40 Watt in Single FRP Body with duly polylurethane coating (Camouflage color), encases with Monocrystalline solar PV Panel of 78/80 Wp, lithium battery 11.1/12.8V, 39.6 AH with inbuilt BMS, IP65, high brightness W-LED 180-200 lm/watt) lamp with Aluminium reflector for better light distribution, CRI>70, Colour Tempeture 5700K-6500K micro controller based charge controller cum driver automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion sensor), dust to dawn operation, suitable to working temperature; -200C to +550C, weight more than 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc including medium class tubular galvanized pole 6 m long and 75 mm dia with 16 mm thick base plate of size 250 mm x 250 mm and 4 Nos 25 mm dia holes complete all as specified and directed. Protection : Short circuit over load reverse plolarity and battery protections. firm should provide Vital parameters test report from NABL accredited lab and should be of made in India CE & ROHS compliant. NOTE:- Earth work and PCC foundation shall be measured and paid seperately under respective item of Sch 'A'. Make - Axxon/Okaya power Pvt Ltd/Havells/Haloix
S&F in replacement MCB TPN 415 volts, 'C' curve of rating from 63 amps, 50 Hz with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement two way terminal block, 63 Amp, screw clamp including two Nos 10 Sqmm copper thimble suitable for mounting in existing din rail complete all as directed.
Taking down existing wire and Supply and fixing single core 10 Sqmm multi stranded copper conductor FRLSH insulated unsheathed cable 1100 volts grade cable including copper lugs 10 Sqmm for connection complete all as diected.
M&L for GI tubing light grade 40 mm bore for cable protection fixed on pole/wall or laid in floor/trenches/drain etc. complete with necessary clamp, nut, bolts, washers and socket for fixing the pipe and making good the disturbed surface of wall, floor or roof etc all as specified and directed.
M&L for straight through joints (heat shrinkable) any type suitable for XLPE/ PVC insulated and sheathed aluminium conductor under ground cable 3.5/4 core 10 to 25 Sqmm and testing after jointing complete all as specified and as directed.
m/s meetu enterprises
M/s SCHOLASTIC ENTERPRISES
Bharat Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .