Tender Value
₹25.0 L
EMD Value
₹50,023
Closing Date
7 Sept 2026, 12:00 pm
Executive Engineer
Ropar Canal and Ground Water Division WRD Punjab
Estimate for Laying uPVC underground pipeline of Sub branches for 78985/R of Bathinda branch
2026_WR_173640_1
45/22A/2026-27
Open Tender
Pipe Laying Works
Item Rate
90 days
village raikot Distt. Ludhiana
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹50,023
Yes
Ropar Canal and Ground Water Division WRD Punjab
27 Aug 2026
27 Aug 2026
7 Sept 2026
27 Aug 2026
7 Sept 2026
27 Aug 2026
2 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, including the cost of diversion for traffic, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. | 5,119.2 | Cum | - | - |
| - | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design | 185 | No. | - | - |
| - | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge)(A) Class PN-1 as per ISI (c) 150mm i/d Sluice Valves flanged | 7 | each | - | - |
| - | Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing all carriages complete (d) C.I Single air valve Screwed(Size 50mm) | 15 | each | - | - |
| - | Providing, laying, fixing, testing and commissioningof Class heavy duty MS Pipe conforming to IndianStandard IS:1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nutsbolts, gasketsetc. fixing the pipe on the wall /ceiling with suitable clamp sandpainting with two or more coats of synthetice paint of required shade complete in all respects. (d)50mm internal diameter | 37.5 | Mtr | - | - |
| - | Construction of masonary Air Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6 m. x 0.6 m. Complete in all respect. | 15 | each | - | - |
| - | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m. Complete in all respect. | 37 | each | - | - |
| - | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct
alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. R.C.C. Pipe NP -2 300mm i/d pipe (for Pucca road crossing) | 7.5 | Mtr | - | - |
| - | Providing and fixing of Alfa valve of 315 mm dia complete Including all tax and charges. | 30 | No. | - | - |
| - | Providing and fixing of Steel Shutter Gate Assembly 500mm | 1 | No. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.98 MB
BOQ_353373.xls
BOQ • 0.53 MB
ccess.pdf
Tender Documents • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].