Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹22.9 L+₹2.8 L (14.2%)Rejected-Finance FLAT NO 1 179 GANESH NAGAR S NO 10 YERAWADA PUNE 411006 | PUNE | MAHARASHTRA | 411006 | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹23.9 L+₹3.9 L (19.2%)Rejected-Finance | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹24.0 L+₹3.9 L (19.3%)Rejected-Finance | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | L5₹25.1 L+₹5.0 L (25.1%)Rejected-Finance | L5 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹34.5 L
EMD Value
₹69,080
Closing Date
5 Oct 2021, 6:00 pmClosed
GE MH AND RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIRS TO WATER PROOFING TREATMENT TO ROOF REPAIRS TO SUNKEN FLOOR AND RELATED WORKS TO CERTAIN MD AND OTM ACCN AT MH AND RH AREA UNDER GE MH AND RH KIRKEE
2021_MES_473934_1
8237/E8
Open Tender
Civil Works
Item Rate
180 days
KIRKEE AND AUNDH
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹69,080
Yes
3 Nov 2021
8 Sept 2021
7 Oct 2021
8 Sept 2021
5 Oct 2021
22 Sept 2021
8 Sept 2021 - 15 Sept 2021
Amount
Dismantling existing water proofing treatment from RCC roof and stone slab including removal of plaster bed below felt / membrane and disposal of the same to distance exceeding 50m but not exceeding 100m as and where directed as specified and directed by engineer In Charge
M&L for Screed bed or bedding layer 15mm thick in cement mortar 1:3 mixed with water proofing compound 3% by weight of Cement or as per manufacturer instruction as a base for APP memrane (WPC Compound paid separately)
Supply only intergral water proofing compound.
M&L for water proofing treatment with polymeric standard water proofing membrane 3mm thick of weight not less than 3.60 kgs/sqm with 90 micron high molecular high density polythelene film sandwiched between two layer of polymeric (stats polypropyline based) bitumen laminated on both sides with 20 micron AMEDPE film over a coat of hot blown bitumen 85/25 grade @ 1.20 kgs/Sqm after priming the plaster surfaces with a bituminuous emulsion (back coat) @ 100gms/sqm membrane shall be fixed unifomly with 10cm over laps by LPG torch flame applying one coat of hot blown bitumen 85/25 grade @ 1.20 kgs/sqm over polymeric membrane including cleaning the surface and finally painted with a coat of bituminous aluminium paint @ 100gms/sqm over bituminous coat complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises complete all as specified and directed.
M&L Coloured ceramic tiles in vertical surface 300x200mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile laid over and including 10 mm thick backing coat in CM 1:4 all as directed.
M&L Coloured ceramic tiles in vertical surface 300x450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile laid over and including 10 mm thick backing coat in CM 1:4 all as directed.
M&L non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry to match the work using colour tiles over screed bed on bedding layer of mortar 15mm thick is CM 1:6 over cement concrete type B-0, 1:2:4 using 12.50mm graded stone aggregate as in floors 25 mm thick, all as specified and directed.
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed.
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for
M&L for waterproofing treatment to RCC sunken slab as specified below. Make: PIDILITE or equivalent. (a) Clean the sunken portion of toilet/Bath/WC/Kitchen throughly to remove laitance, dirt, dust, etc. b) M&L for Making hole and fix 12mm dia GI Nozzle @0.5 mtr c/c on the entire area of sunken portions and applying chemical injection grouting through the nozzles with cement slurry admixture with dr fixit bath seal grouting or other equivalent with pressure pump in 40 PSI.seal off the nozzleand cutting the same after grout has set as specified and directed by engineer in charge (c) Form angle fillet of size 40 mm x 40mm ith cement sand mortar (1:3) admixed with diluted ("Dr Fixit" Pidicrete URP" or equivalent)1:3 (d) Wet the surfaces with water to make it saturated surface dry condition (e) Sanitary pipes entering through walls and floor shall be sealed with " Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout " Dr Fixit Bathseal Gruot" or eqvt . Nahani traps , etc to be fitted securely and the gaps around it to grouted in the same manner. (f Apply one coat of Acyrylic polymer modifed cementious slurry coating with "Dr Fixit Bathseal Plus" or eqvt on all angle fillets by brush and cover it with 100 mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completelyand turned upto 150mm from FFL and all as per manufacturing specification (g) Ponding test for water leakage will be carried as per IS 3370 part 1 a instructed (h) Applying 15mm thick plaster in C:M 1:3 mixed with water proofing compound 3% by weight of Cement or as per manufacturer instruction (i Plumbing works to be providedaccording to proper level&slope seal off the pipesand back fill the gap properly and Provide 40mm OD UPVC pipe at the lowest point with 300mm projection beyond the outer face of the wall.Then fill up the sunken portion with lean concrete 1:5:10 type E2.
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tille with heavy duty tile cleaner preferbly of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, or equivalent , curing , cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
M&L for water proofing treatment of External walls, chhajjas DFT: 110 microns by applying two coats of elestromeric coating Raincoat, material covering capabity 3 Sqm per litre in 2 Coats without dilution & 1 coat of efflorescent resistant primer 10sqm/litre/coat after cleaning the surface throughly and sealing all cracks with acrylic sealing compound as per the manufacturers specifications and directions of Engr-in-Charge Make :- Raincoat shall be of PlDlLlTE or equivalent. The product shall have following properties: Elongation > 100% as per ASTM D 412, Tensile strength : 2.5 Mpa as per ASTM D 412, Water Resistance conforming to SS 500, Crack bridging ability conforming to Class A4 as per EN 1062 Part 7, Positive hydrostatic pressure > 7 bar as per DIN 1048, Anti-carbonation property complying EN 1062 Part 6, RCPT conforming to ASTM C 1202.
M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM (1:3) with WPC, finished even and smooth without using extra cement all as specified and directed
Making hole and M&L for fixing thr metallic packer for hydrophobic PU foam and Sealer as per manufacturers specification. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
MM&L for treating the dampness of wall with Siliconate injection grout (The spacing of holes shall be 2 Nos holes in every 1m) by making 12mm to 15mm holes at an inclination of 45 degrees to the extent of 112 to 3/4 of the wall thickness and inject the diluted chemical liquid (1 :4) (Min 10 Ltrs), in the lowest possible point by using a pressure grouting machine with a pressure of approximately 3 Kg/sqcm' till the point of return of liquid and seal the treated holes with suitable compound and washed thoroughly the treated areas with water all as directed.
Taking down cement plaster in any description incl racking out joints hacking for key and scrubbing down with water etc. Spd and directed by EIC
M & L 15 mm thick rendering on fair faces of brickwork / concrete surface on wall in CM 1:4 using WPC @ 3% by weight of cement, all as specified and directed Note:- WPC shall be measured seperately.
M & L applying two coats of weather proof exterior emulsion paint (apex Ultima or equivalent) with approved colour and pattern over a coat of primer as on walls of Bldgs of any height including necessary and procedure complete all as specified and directed. Note : Safety precautions scaffolding and safety measures like rope, safety belts, helmets , ladder etc shall be responsibility of contractor
M & L applying two coats of cement base paint to newly plastered surface of wall including preparation.
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store
S&F steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
S&F steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Re Fixing old steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Re Fixing old steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
S & F in repairs water closet (Squat Pattern) complete incl provn of lime concrete bedding Orissa pattern size 580 x 440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repairs PVC low level flushing system 10 Ltr capacity with flush pipe complete as specified and directed.
S & F in repairs stopvalves cast copper alloy screwed down high pressure withcrutch or butterfly handle screwed both ends for iron pipe 15 mm dia all asspecified and directed.
S&F in repairs grating square or circular 125mm dia of PTMT (minimum weight 100 gms, all as specified and directed.
Taking down drain pipes (any size or pattern), including all fittings, T, bends,etc., including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories)
S&F PVC (SWR) pipes 110 mm dia single sockets, in any length rubber ring joints, laid in trenches or in floor all as specified and directed.
S&F PVC (SWR) pipes 75 mm dia single sockets, in any length rubber ring joints, laid in trenches or in floor all as specified and directed.
S&F PVC (SWR) 110mm dia bends any radius all as specified and directed.
S&F PVC (SWR) branch 110mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
S&F PVC (SWR) junction110mm bore single ( single t) equal or unequal all as specified and directed.
S&F PVC (SWR) 75 mm dia bends any radius all as specified and directed.
S&F PVC (SWR) junction 75 mm bore single ( single t) equal or unequal all as specified and directed.
S&F PVC (SWR) branch75 mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
M & L PCC (1:5:10) using 40mm graded aggregate as in mass concrete or as in sunken floor complete all as specified & directed
M&L for 75 mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggr as in floors and sub base complete all as specified and directed.
Dismantling water tank of any description or capacity 500 ltrs all as specified as directed.
Dismantling water tank of any description or capacity 750/1000 ltrs all as specified as directed.
Fixing only Rotational moulded polyethylene water storage tanks ( cylindercal veritcal with closed top) hoisted and fixed inposition 1000 ltrs capacity all as specified
Fixing only Rotational moulded polyethylene water storage tanks ( cylindercal veritcal with closed top) hoisted and fixed inposition 500 ltrs capacity all as specified
Supply & Fixing in repairs viterious china wash basin white flat back size 550 x 400 mm excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP wastes and other fittings all as specified and directed by EIC.
Supply & Fixing in repairs pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered Hot Or Cold Withlong screwed shanks and fly nuts screwed for iron pipes 15mm dia all as specified and directed
Supply & Fixing in repairs Fancy type bib taps chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia all as specified and directed by EIC.
S & F brass CP shower rose 125mm size with swivel joint incl fixing to steel pipe fixed in repairs as directed
S&F of PVC connections 15mm size with brass nut on both end washers of length 450mm all as specified
S&F Rotational moulded polyethylene water storage tanks ( cylindercal veritcal with closed top) hoisted and fixed inposition 1000 ltrs capacity all as specified
S&F Rotational moulded polyethylene water storage tanks ( cylindercal veritcal with closed top) hoisted and fixed inposition 750 ltrs capacity all as specified
S&F Rotational moulded polyethylene water storage tanks ( cylindercal veritcal with closed top) hoisted and fixed inposition 500 ltrs capacity all as specified
S & F 15 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed ( Minimum weight 15 mm - 142 grams/20 mm - 210 grams . 25 mm - 455 grams) complete all as specified and directed.
S & F 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed ( Minimum weight 15 mm - 142 grams/20 mm - 210 grams . 25 mm - 455 grams) complete all as specified and directed.
M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise N.exc 100 sq.cm all as specified and directed
M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise exc 100 sq.cm and n.exc 250 sq.cm all as specified and directed
TULSAYA CONSTRUCTION
M/S JAYCONSTRUCTION CO
L.K.R.TIWARI CONSTRUCTION
MANIYA CONSTRUCTION CO.
GRACE CONSTRUCTIONS
M/S SANDEEP H BHINGARDIVE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .