| 1 | L1₹42.7 LAccepted-AOC | ₹42.7 L Quoted ₹43.3 L | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹47.1 LRejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHATRAPATI SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKTA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹47.1 L | L2 | Rejected-Finance Being Other than Lowest Tenderer |
| 3 | L3₹47.3 LRejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹47.3 L | L3 | Rejected-Finance Being Other than Lowest Tenderer |
| 4 | L4₹47.7 LRejected-Finance | ₹47.7 L | L4 | Rejected-Finance Being Other than Lowest Tenderer |
| 5 | L5₹48.0 LRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹48.0 L | L5 | Rejected-Finance Being Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | TETRI ENTERPRISES L4 | Darpan Construction L3 | Chakshu Enterprise L6 | Shree Ayyappa Engineering L5 | cooltech engineering services L2 | GANGAJAL L7 | shubham construction L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & fixing in replacement fire alarm control panel complying with BE EN 54, 4 loop panel with 99 detectors & 99 Modulas & upto 200 dectors and modules per loop complete all as specified and directed. | 1 | Each | 2,05,767 ₹2.1 L | 2,00,000 ₹2 L | 1,92,350 ₹1.9 L | 1,82,350 ₹1.8 L | 1,96,223 ₹2.0 L | 1,42,875 ₹1.4 L | 1,85,000 ₹1.9 L |
| 2.00 | Supply & fixing in replacement detectors complying with and type certified to EN -45 Addrssable type multi senser detector photoelectric/Optical with base self built intellgence as per IS:11360 | 140 | Each | 4,978 ₹7.0 L | 5,200 ₹7.3 L | 5,742 ₹8.0 L | 5,522 ₹7.7 L | 6,000 ₹8.4 L | 3,700 ₹5.2 L | 4,500 ₹6.3 L |
| 3.00 | Supply and fix in repair of Addressable type heat detector with base with rate of rise cum fixed temperature as per IS: 2175 | 7 | Each | 4,795 ₹33,565 | 4,900 ₹34,300 | 5,456 ₹38,192 | 5,122 ₹35,854 | 6,000 ₹42,000 | 3,100 ₹21,700 | 4,300 ₹30,100 |
| 4.00 | Supply& Fixing in repair addressable manual call point resettable type complete all as specified and directed. | 17 | Each | 5,573 ₹94,741 | 4,900 ₹83,300 | 5,285 ₹89,845 | 5,122 ₹87,074 | 5,600 ₹95,200 | 2,700 ₹45,900 | 5,200 ₹88,400 |
| 5.00 | Supply & fixing in repair addressable electronic sounder cum srobe complete all as specified and directed. | 12 | Each | 6,283 ₹75,396 | 6,000 ₹72,000 | 7,412 ₹88,944 | 6,623 ₹79,476 | 7,000 ₹84,000 | 4,700 ₹56,400 | 5,800 ₹69,600 |
| 6.00 | Supply & fixing remote response indicators complete all as specified and directed. | 15 | Each | 1,682 ₹25,230 | 2,000 ₹30,000 | 1,456 ₹21,840 | 2,211 ₹33,165 | 1,200 ₹18,000 | 1,047 ₹15,705 | 1,520 ₹22,800 |
| 7.00 | Supply, laying & testing in replacement of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade complete all as specified and directed. | 3,250 | RM | 173 ₹5.6 L | 190 ₹6.2 L | 177 ₹5.8 L | 177 ₹5.8 L | 150 ₹4.9 L | 175 ₹5.7 L | 160 ₹5.2 L |
| 8.00 | Supply and fixing of Cable glands suitable for 2 core 1.5 Sqmm copper conductor armoured cable drawn under PVC conduit complete all as specified and directed. | 250 | Each | 173 ₹43,250 | 200 ₹50,000 | 177 ₹44,250 | 199 ₹49,750 | 150 ₹37,500 | 77 ₹19,250 | 145 ₹36,250 |
| 9.00 | supply & fixing of fire proof juction box complete all as specified and directed. | 150 | Each | 427 ₹64,050 | 225 ₹33,750 | 456 ₹68,400 | 352 ₹52,800 | 450 ₹67,500 | 105 ₹15,750 | 400 ₹60,000 |
| 10.00 | supply & fixing Addressable control module complete all as specified and directed. | 12 | Each | 6,085 ₹73,020 | 5,000 ₹60,000 | 4,896 ₹58,752 | 5,522 ₹66,264 | 4,000 ₹48,000 | 4,700 ₹56,400 | 5,500 ₹66,000 |
Updated dates
Tender Value
₹47.0 L
EMD Value
₹94,026
Closing Date
2 Jan 2026, 6:55 pmClosed
LT COL ANIL KUMAR S
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8255 SPL REPAIR OF AUTOMATIC FIRE DETECTION AND ALARM SYSTEM (AFDS) AND LT POWER SUPPLY DISTRIBUTION NETWORK IN BUILDING NO. P-244 AT ND (MBI) AND PROVISION OF SPLIT ACs AGAINST BER AT CQAE (MS) MUMBAI
2025_MES_743416_1
8255/E8
Open Tender
Civil Works
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹94,026
Yes
5 Feb 2026
6 Dec 2025
3 Jan 2026
13 Dec 2025
2 Jan 2026
20 Dec 2025
6 Dec 2025 - 13 Dec 2025
Supply & fixing in replacement detectors complying with and type certified to EN -45 Addrssable type multi senser detector photoelectric/Optical with base self built intellgence as per IS:11360
Supply, laying & testing in replacement of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade complete all as specified and directed.
Supply and fixing of Cable glands suitable for 2 core 1.5 Sqmm copper conductor armoured cable drawn under PVC conduit complete all as specified and directed.
supply & fixing of fire proof juction box complete all as specified and directed.
Incoming : (a) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual drawout type) of capacity 800 Amps -01 (Incoming )
Outgoing : (a) MCCB, 4 pole 200Amps,36KA,Thermal magnetic- 1 Nos
b) MCCB, 4 pole 160 Amps,36KA,Thermal magnetic- 4 Nos (03 for load and 01 spare)
c) MCCB FP 125 A, 36 KA Thermal magnetic-06 Nos (04 for load and 02 spare)
d) MCCB 4 Pole 100 A, 25 KA Thermal magnetic-03 Nos (2 for lad and 01 spare)
d) Digital type Volt meter , digital type ,0 - 800V - 1 Nos, Make : L&T/Scinder
e) Digital type Ammeter, digital type with CT's - 1 No Make : L&T/Scinder
f) Indication lamps (R,Y,B) LED type - 1 set
Note: (a) Make of MCCB : Siemens/Legrand Dismantling of old panel/cable cost are demmed to be included
All as per item No. 19 above but for aluminium conductor cable size 70 sqmm 3.5 core
All as per item No. 19 above but for cable size 95 sqmm 3.5 core
All as per item No. 19 above but for cable size 120 sqmm 3.5 core
All as per item No. 19 above but for cable size 185 sqmm 3.5 core
Excavation in trenches n exc1.5m wide and n exc in depth for laying of cables and getting out in loose/soft soil complete all as directed.
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point complete all as directed.
M&L for un-reinforced,precast concret cable cover of size 250x150x40mm class LV type-I for cable protection all as specified and directed
S&F in replacement of unserviceable MCCBs of following capacities :-
(a) MCCB 63 Amps, 25 KA capacity 4 Pole. Make C& S/ Legrand/GE
(b) MCCB 100 Amps 25 KA capacity 4 Pole. Make C& S/ Legrand/GE
(c) MCCB 125 Amps 25 KA capacity 4 Pole. Make C& S/ Legrand/GE
M & L Submain wiring with 2x 4 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one PVC insulated & unsheathed multistranded copper conductor 4.0 Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly. Make Of Wire : Polycab/Plaza/Havells/Gloster
S&F for Rigid non-metallic PVC conduit 20mm dia with complete of all tees,bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs all as specified and as directed
S&F for Rigid non-metallic PVC conduit 40 mm dia with complete of all tees,bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs all as specified and as directed
S & F and clamping jointing copper tubing for suction line and for liquid discharge incl duly insulated with suitable insulation material including making hole in wall for passing through amd making to the disturb surface complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
8255TENDERDOCUMENTS.pdf
Tender Documents • 1.37 MB
BOQ_832428.xls
BOQ • 1.30 MB
Download all tender documents and submit your bid